Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹9.2 LAccepted-AOC | 1 | Accepted-AOC due to L1 and credit | |
| 2 | 2₹10.6 L+₹82,025 (8.39%)Rejected-Finance M 78 GARU HARKISHAN NAGAR PASCHIM VIHAR NEW DELHI 110087 | NEW DELHI | WEST DELHI | DELHI | 110087 | 2 | Rejected-Finance Being other than L-1 | |
| 3 | 3₹10.6 L+₹85,550 (8.75%)Rejected-Finance MOH HATHITHAN NIGOHI ROAD SHAHJANPUR UP 242001 | SHAHJAHANPUR | UTTAR PRADESH | 242001 | 3 | Rejected-Finance Being other than L-1 | |
| 4 | 4₹11.0 L+₹1.2 L (12.0%)Rejected-Finance | 4 | Rejected-Finance Being other than L-1 | |
| 5 | 5₹11.4 L+₹1.6 L (16.1%)Rejected-Finance 43 VIMAL ENCLAVE CHAMRAULI MODE SHAMSHABAD ROAD AGRA UP 282001 | AGRA | AGRA | UTTAR PRADESH | 282001 | 5 | Rejected-Finance Being other than L-1 |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
15 Jan 2025, 6:00 pmClosed
GE (AF) ADM AREA AGRA
GE (AF) Adm Area Agra UP 282008
REPAIR MAINT OF CEILING FANS IN CAMP AREA UNDER GE(AF) ADM AREA AT AF STN AGRA.
2024_MES_689632_1
8000-2204/E8
Open Tender
Entertainment/Musical Instruments
Item Rate
180 days
GE (AF) ADM AREA AGRA
Please refer Tender documents.
4 documents required · 4 mandatory
₹500
GE (AF) ADM AREA AGRA
₹30,000
Yes
3 Apr 2025
20 Dec 2024
17 Jan 2025
20 Dec 2024
15 Jan 2025
3 Jan 2025
Amount
Taking down/collect the unserviceable/burnt ceiling fan/exhaust fan/pedestal fan/wall mounted fan/cabin fan any sweep from any height of building/site for repair/rewinding/overhauling and re-fixing the same after repair/overhauling and testing fans complete at same place or where directed complete all as specified. NOTE :- (i) Fixing of repaired fan in any location of camp area shall be contractors responsibility at his own arrangement of transport and T& P. (ii) Old burnt wire will be contractors property and necessary credit shall be recovered as per sch of credit attached) Note – Repair/rewinding/overhauling shall be measured & paid separately under respective items of Sch.
M&L for strip opening of ceiling fan 1200/1400 mm sweep for overhauling including cleaning, greasing, oiling and minor repair work, including checking nuts and bolts, clamps etc complete and reassembling the same after testing on full load with blade complete all as specified and directed. (Note: Capacitor, Bearings, Regulators, Rubber reel and other connected items shall be measured and paid separately under respective items as supply and fixing).
Description all as per Item No 2 here-in-before but for exhaust fan size 300 to 450 mm sweep complete all as specified and directed.
Description all as per Item No 2 here-in-before but for wall mounted fan/cabin fan of size up to 450 mm sweep complete all as specified and directed.
M&L for rewinding of ceiling fan motor 1200/1400 mm sweep any make with super enameled copper winding wire ISI marked of gauge as per existing including cutting and getting out old US winding, sleeve work, varnishing , threading incl. making connections with three core copper flexible wire of suitable size and reassembling the same and two coats of synthetic enamel paints with spray painting and writing MES number ind. cleaning the fan with cleaning materials or thimmbles after testing at full load with blades to the entire satisfaction of Engineer incharge complete all as specified and directed. Note: Rewinding work of ceiling fan/ exhaust fan/ cabin/wall mounted fan shall be carried out inside the camp area at the location provided by department.
Description all as per Item No 5 here-in-before but exhaust fan of size 300 mm sweep, 230 V, AC complete all as specified and directed.
Description all as per Item No 5 here-in-before but exhaust fan of size up to 450 mm sweep, 230 V, AC complete all as specified and directed.
Description all as per Item No 5 here-in-before but for wall mounted/cabin fan of size up to 450 mm sweep complete all as specified and directed..
M&L for machining the shaft of ceiling fan to suit the gun metal bushes off sizes complete all as directed.
S&F in repair Ball bearing of ceiling fan of size 6201/6202 complete all as specified and directed.
S&F in repair Ball bearing of exhaust fans of size 6203/6204 complete all as specified and directed.
S&F in repair Gun metal bushes for exhaust fans of suitable sizes complete all as specified and directed.
S&F in repair capacitor 2.5 MFD, 230V, AC complete all as specified and directed.
S&F in repair capacitor 3.15 MFD, 230V, AC complete all as specified and directed.
S&F in repair capacitor 4 MFD, 230V, AC complete all as specified and directed.
S&F in repair shackle rubber bush/rubber reel of suitable sizes for ceiling fan 1200 / 1400 mm sweep complete all as specified and directed.
S&F in repair flexible wire 23/0.0076 size three core, 1100 V, twisted, PVC insulated, copper conductor multistrand for connection complete all as specified and directed.
S&F in repair MS nut & bolt with cut washers 8 mm dia and safety pin of suitable length for hanging of the ceiling fans complete all as specified and directed.
S&F in repair MS clamp including rubber washer, nut, bolt, washer and safety pin for hanging the ceiling fans of suitable size complete all as specified and directed.
S&F in repair Down rod MS 15mm dia, heavy duty of size 300 mm long including making hole for hanging ceiling fan complete all as specified and directed.
S&F in repair Down rod MS 15mm dia, heavy duty of size 450 mm long including making hole for hanging ceiling fan complete all as specified and directed.
S&F in repair ceiling fan regulator electronic switch type 5 stage speed variation ISI marked complete all as specified and directed.
S&F in repair ceiling fan regulator electronic socket type 5 stage speed variation ISI marked complete all as specified and directed.
M&L for preparing the surface of ceiling fan, exhaust fan, pedestal fan including cleaning, removing grease, carbon dust and painting with one coat of synthetic enamel paint of approved colour with brush painting and writing MES number complete all as specified and directed.
S&F in replacement PVC clamp for capacitor for fans of suitable sizes complete all as spd and directed.
S&F in replacement PCB suitable for existing BLDC ceiling fan 1200mm for existing make , 230V, AC, 26/28 watts complete all as spd and directed. Make- Halonix/ Bajaj/ Crompton
S&F in replacement motor suitable for 250mm PVC exhaust fan for existing make & model , 230V, AC complete all as spd and directed. Make- Havells/ Bajaj/ Crompton
Dismantling of existing meter panel board removing existing energy meter keeping safe custody and Design, Supply, installation, testing and commissioning of indoor type wall mounting size min (1280X 775X245), Polycarbonate CPRI approved OEM made Meter Panel. The panel shall be made of modular POLYCARBONATE THERMOPLASTIC ENCLOSURES which should be UV resistance in accordance with IEC 61439-1, clause 10.2.4: The panel type wall mounted on mounting structure RAL 7016. The meter panel should be anti-acid & anti corrosive & fully transparent Door for meter vision. Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262. The manufacturer of panel shall submit a copy of CPRI test report in polycarbonate only degree of ingress protection IP65 in accordance with IEC 60529. The gasket should be internally embedded made of polyurethane and enclosure make. The manufacturer of board/panel shall submit a copy of type test report of a board made out of Polycarbonate thermoplastic panel in accordance with IEC 60439-1. The CPRI test report shall have mention of following tests performed and passed out satisfactorily: Temperature Rise, Dielectric Properties, Short circuit withstand current – Rated peak & short time withstand current and Rated Conditional Short Circuit Current, Effectiveness of Protective Circuits. The board manufacturer must submit the copy of type test reports for Polycarbonate Thermoplastic Board only. Test Reports submitted of other material of construction like MS, SS will not be applicable.. The panel should passed glow wire test 960oC in accordance with 60695-2-11 flame retardant and self-extinguishing complete all as directed with and incl the following (a) Provision for existing electric energy meter - 04 nos in separate chamber with locking arrangement. (a) Four pole MCCB 63 Amps with breaking capacity 16 KA having fixed thermal and fixed magnetic release and spreader link at both incoming and incoming side - 01 No. (b) MCB DP 32 Amp 10 KA , C Curve - 4 Nos (To be connected with 4 Nos Meters) (c) MCB DP 06 Amp 10 KA, C Curve - 1 No (For common lighting + Bldg Security Lights) (d) Ten Nos terminal blocks provided for output supply. (e) MCCB/MCB Nos Operated by flip Cover (f) LED Indicating lamp - 03 Nos. (g) Internal wiring with 1100Volt grade 6.0 Sqmm FRLS PVC insulated multi flexible copper wire of sizes duly crimped with copper lugs of suitable size & type . Note : Re-fixed the energy meter in this new meter cabinet including all necessary electrical connection.
M & L for point wiring for light/fan controlled by one switch with 1.5 sqmm single core 1100V grade FRLSH PVC insulated unsheathed multistranded copper conductor with and including PVC concealed conduit of medium grade with all fittings including MS pressed steel shet (1.6mm thick) sunk box with 3mm thick ISI marked laminated bakellite sheet fixed with cromium / nicckel plated screws and washers for switches and sockets, including 1.5 sqmm single core 1100v grade FRLSH PVC insulated unsheathed multistranded copper conductor as earth continuity conductor connected to common earth dolly and including cutting chases in walls / floors for concealed conduiting and making good disturbed surface area and white wash/colour wash to matching with the existing colour and including taking down old unserviceable copper/aluminium point wiring (light, fan, socket , power socket and bulk head fittings) on surface wiring on wooden batten/casings & caping complete, including fixture and fittings such as switches, ceiling roses,pendents holder, regulators, sockets and defective main switch/DB/MCB/Metal plug etc. by unscrewing carefully from boards etc and making good disturbed surfaces of walls complete all as specfied and directed.
S&F switch piano flush type one way 5 amps SP 240 volts complete all as specified and directed.
S&F ceiling rose 65 x 50mm three terminals complete all as specified and directed.
Supply and fixing exhaust fan 300 mm sweep steel body, AC, Single phase, 230 volts complete with louvers shutters and including PVC insulated three core 1.5 sqmm copper cable from ceiling rose to exhaust fan complete all as specified and directed.
Supply and fixing exhaust fan 250 mm sweep PVC body, AC, Single phase, 230 volts complete with louvers shutters and including PVC insulated three core 1.5 sqmm copper cable from ceiling rose to exhaust fan complete all as specified and directed.
S&F in replacement mild steel louvers/shutters suitable for 300 mm sweep exhaust fan including fixing arrangement complete all as spd and directed.
S&F in replacement mild steel louvers/shutters suitable for 450 mm sweep exhaust fan including fixing arrangement with nuts, bolts and pvc sheet for suitable size of hole complete all as spd and directed.
SALUJA CONSTRUCTION CO (BID ID -3209237)
avon electric engineering woks (BID ID -3209192)
DHARMA ENGINEERS AND CONTRACTOR (BID ID -3206516)
S S TRADERS (BID ID -3208728)
MUKTA AND COMPANY (BID ID -3208879)
TRIVENI ASSOCIATES (BID ID -3214889)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .