Loading…
Loading…
Tender Value
₹58.1 L
EMD Value
₹1.2 L
Closing Date
10 Jun 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
S AND T
14 conditions · 2 needing a document upload
For works amounting Rs.50 lakhs and above: The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of 'total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i) Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or (ii) Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or (iii) One similar work costing not less than the amount equal to 60% of advertised value of the tender.
Defination of Similar Work :- Any work of Signal or Telecom involving trenching, laying & testing of Signal or Telecom cables OR Any other miscellaneous outdoor S&T work.
9 conditions · 2 needing a document upload
Demand for the Financial Criteria, Association of Railway Officers, List of Arbitration cases, Court cases and Mandate for NEFT are to be uploaded with a scanned copy duly filled in and signed as per annexure no. IV, V, VI, VII, VIII, IX, XI, VIA, VIB, VI and Annexure-V and Annexure-V(A) of GCC-2022 respectively. These Annexures are available in View Document menu at Home page and is downloadable. The details of the uploaded documents should be produced whenever demanded for verification on written request at any point of time of the tender and contract within 7 days.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Tenderers are requested to go through the following documents which are available in upload/View Documents in Home page of IREPS portal for works tenders before submitting the e-tender. 1. General Instruction for E-Tenders on works contract--Chapter- I 2. Special Condition-General- Chapter-II
Opening of e-tender : 1. The e-tenders will be opened online using the IREPS portal anytime after tender closing time. No representative is required to be present for opening of e-tender and taking notes of rates quoted and ranking as the complete details of rates etc. of all the bidders shall be available to the bidders through the website after the opening of the tender. 2. The earnest money cost is to be paid through online banking facilities through the online portal and by giving the other details online on website www.ireps.gov.in. Note: For more details refer to Cl: 4 & 12 of General Instruction-Chapter-I for Submission of EMD, Cost of Tender Document and opening of e- tender.
Asansol Division: Improvement of Signal visibility and repairing of defective modules of fire alarm system in Asansol Division.
19-SDSTE-ASN-2026-27
19-SDSTE-ASN-2026-27
Open
Works - General
12 Months
Paschim Bardhaman, West Bengal
₹0
₹1.2 L
10 Jun 2026
19 May 2026
27 May 2026
83 items across 2 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | Above/ 3776763.00 Below/P | ||
| — | 30.00 | — | — | ||
| Supply of color light signal post 5.5 mtr. as per RDSO SPEC. NO. IRS:S-6-81 (or latest) and Drg. No. SA-23156 (ADV), Alt-1 or latest. Materials to be procured only from RDSO approved list of firms for manufacture & supply of mechanical signaling items. Inspection: Consignee. | — | — | — | 4,16,370 | |
| — | 30.00 | — | — | ||
| Supply of 140 mm diameter Cast Iron (Grade-20) Signal base as per Drawing No. S- 2011/M and as per Specification No. IRS:S-10/78 & IS:210 or latest. Inspection: Consignee. | — | — | — | 1,89,600 | |
| — | 30.00 | — | — | ||
| Supply of 5.5 meter Ladder for Color Light Signal as per RDSO Drawing No. SA-23156 (Adv.) or latest and Stage with Ladder as per Drawing No. S-2033/M (IRS) or latest & as per Specification No. IRS:S-10/78 & IS:210 or latest. Inspection: Consignee. | — | — | — | 3,64,320 | |
| — | 30.00 | — | — | ||
| Casting, concreting & curing of foundation for Main signal including cost of all materials required for casting and concreting. All materials required for execution will be supplied by the contractor including cement, sand & stone chips, Foundation Bolts, PVC Pipe, shuttering etc. as per Drg. No. S&T/C-42(NKG). | — | — | — | 3,04,980 | |
| — | 5.00 | — | — | ||
| Supply of FRP type color light signal unit 2 aspect complete as per Drg. No. SA- 23003/AIM with latest amendments and as per RDSO Spec. no. RDSO/SPN/194/2006 Rev. 2.0 or latest. Inspection: Consignee | — | — | — | 1,61,870 | |
| — | 10.00 | — | — | ||
| Supply of FRP type color light signal unit 3 aspect complete as per Drg. No. SA- 23002/AIM with Latest amendment and as per RDSO Spec. no. RDSO/SPN/194/2006 Rev. 2.0 or latest. Inspection: Consignee. | — | — | — | 3,48,960 | |
| — | 5.00 | — | — | ||
| Supply of FRP type color light signal unit 4 aspect complete as per Drg. No. SA 23001/NM with Latest amendments and as per RDSO Spec. no. RDSO/SPN/194/2006 Rev.2.0 or latest. Inspection: Consignee. | — | — | — | 1,97,230 | |
| — | 30.00 | — | — | ||
| Erection of surface base, signal post, mounting of Color Light Signal up to 4 aspects complete on signal post, offset bracket, LED fixing, plumbing of the signal through sealing gap between Surface base and signal post, fixing of ladder with platform complete and concreting of ladder shoe, fixing of number plates, marker board, termination tail cables, wiring of signal unit, fixing of EWS locks, and painting of one coat of red oxide and two coats of aluminium/enamel paints , black paint on post, ladder, Platform, ladder shoe as per practice. When the aspect is fixed on an offset bracket using 'U' bolts and nuts, a through bolt shall be provided by drilling a hole in the signal pole to prevent the offset bracket from sliding down. Painting of Signal unit with two coats of white inside and Black outside (Supply of surface base, offset bracket, CLS pole, CLS aspects complete, ladder with shoes and platform, LED aspects, and wire coils will be supplied by Railways). (through bolts and nuts, cement, stone jelly 20/25mm dia. river sand, Signal Color Rings, all fixing bolts and nuts, teak wood, paints PVC/Nylon sleeves and all other miscellaneous materials for the work shall be supplied by the contractor) | — | — | — | 3,99,420 | |
| — | 5.00 | — | — | ||
| Supply of 1 WAY FRP TYPE JUNCTION ROUTE INDICATOR as per RDSO Drg. No. SA- 23401(Adv.)/ (Alt.2). Inspection: Consignee. | — | — | — | 1,67,985 | |
| — | 4.00 | — | — | ||
| Supply of 2 WAY FRP TYPE JUNCTION ROUTE INDICATOR as per RDSO Drg. No. SA- 23402(Adv.)/ (Alt.2). Inspection: Consignee. | — | — | — | 1,69,040 | |
| — | 2.00 | — | — | ||
| Supply of 3 WAY FRP TYPE JUNCTION ROUTE INDICATOR as per RDSO Drg. No. SA- 23403(Adv.)/ (Alt.2). Inspection: Consignee. | — | — | — | 82,594 | |
| — | 20.00 | — | — | ||
| Supply of cast iron offset bracket for Main Signal with U clamps, nuts, washers complete Drg. No. SA-23080/ADV/Alt-1. RDSO Spec. No. IRS-S-10/78. Inspection: Consignee. | — | — | — | 63,360 | |
| — | 4.00 | — | — | ||
| Fixing of junction type route indicator - 1 way - complete / fixing of additional limb to the existing route indicators, termination of tail cables, wiring, fixing of required number of EWS locks, wire mesh and painting. [Fixing bolts and nuts, wire mesh, PVC / Nylon sleeves, paints and all other miscellaneous materials shall be supplied by the contractor]. | — | — | — | 8,544 | |
| — | 3.00 | — | — | ||
| Fixing of junction type route indicator - 2 way - complete / fixing of additional limb to the existing route indicators, termination of tail cables, wiring, fixing of required number of EWS locks, wire mesh and painting. [Fixing bolts and nuts, wire mesh, PVC / Nylon sleeves, paints and all other miscellaneous materials shall be supplied by the contractor]. | — | — | — | 7,590 | |
| — | 2.00 | — | — | ||
| Fixing of junction type route indicator - 3 way - complete / fixing of additional limb to the existing route indicators, termination of tail cables, wiring, fixing of required number of EWS locks, wire mesh and painting. [Fixing bolts and nuts, wire mesh, PVC / Nylon sleeves, paints and all other miscellaneous materials shall be supplied by the contractor]. | — | — | — | 5,846 | |
| — | 5.00 | — | — | ||
| Supply of Calling ON Signal Unit with Brackets & Fixing accessories. Calling ON / Guard Repeater Signal Unit shall conform to RDSO Drg. No. 24351(Adv.) Alt1. suitable for LED Signal Lighting Unit. Inspection: Consignee. | — | — | — | 15,965 | |
| — | 5.00 | — | — | ||
| Fixing of Calling-on Signal unit on signal post including Guard Repeater Signal. The item includes fixing of Co-On signal unit on signal post with bracket, hood etc. Item includes supply of bracket & fixing materials etc. by the contractor. The item also includes termination of cables & wiring inside Co-On signal unit as per standard practice. | — | — | — | 14,715 | |
| — | 5.00 | — | — | ||
| Supply of dependent/position light type Shunt Signal complete as per Drawing No. SA-23840(Adv.) Alt.2 or latest, S-23023 or latest with offset bracket to Drg. No. SA23080 Adv. Alt. 1 or latest to suit 140 mm. dia. post complete as per Specification No. IRS:S-10/78 Rev.8 or latest. Inspection: Consignee. | — | — | — | 34,940 | |
| — | 5.00 | — | — | ||
| Supply of offset bracket for position light shunt signal (90 mm. outside Dia.) post with U clamps, nuts, washers complete as per RDSO Drg. No. SA-23080/ADV/ALT-1 all drawings should be as per latest. Inspection:Consignee. | — | — | — | 12,865 | |
| — | 6.00 | — | — | ||
| Provision of SCREEN on signals when they fall within 2 meters from the live conductor by expanding metal (size 20 mm. x 60 mm. strand 3.25 mm. wide and 1.6 mm. thick) as per the instruction of the site engineer in charge. This includes supply of all materials including connection with earth electrode. Provision of SCREEN on signals when they fall within 2 meters from the live conductor by expanding metal (size 20 mm. x 60 mm. strand 3.25 mm. wide and 1.6 mm. thick) as per the instruction of the site engineer in charge. This includes supply of all materials including connection with earth electrode. Inspection: Consignee. | — | — | — | 24,930 | |
| — | 10.00 | — | — | ||
| Supply of P / C / G marker as per relevant drawing and as per IRSEM and as per standard practice. Inspection: Consignee. | — | — | — | 6,940 | |
| — | 15.00 | — | — | ||
| Supply, Fabrication of Retro reflective Nomenclature Board of size 254 mm. x 358 mm. made of 2 mm. thick aluminium sheet & high intensity prismatic (hip) grade retro reflective sheet (TYPE-IV) including fixing arrangement for fixing them on existing post as per relevant drawing and as per IRSEM and standard practice. Details of station, signal type and number to be obtained before supply. Inspection: Consignee. | — | — | — | 7,050 | |
| — | 100.00 | — | — | ||
| Supply of Light class GI pipes 100 mm. dia. (thickness 3.6 mm.) as per IS 1239 (Part- 1):2004 or Latest with socket & coupling. Inspection: Consignee. | — | — | — | 1,32,600 | |
| — | 0.10 | — | — | ||
| Laying of HDPE/DWC/GI Pipes. | — | — | — | 759 | |
| — | 2.00 | — | — | ||
| Excavation of trench at a of Depth of 1200 mm. and width of 300 mm., including marking of cable alignment, clearing of jungle, roots of trees, bushes, refilling with excavated soil, ramming and consolidation after laying of cables complete to the finished item of work in all type of Soil. NOTE: In case 1.2 m. depth of the trench is not achievable due to site conditions approval of officer in charge is to be obtained and payment shall be made on a prorate basis. | — | — | — | 1,95,644 | |
| — | 4000.00 | — | — | ||
| Laying of S&T Cables of various cores/pairs/quads in trenches/GI pipes/RCC pipes/DWC pipes/Trunking. | — | — | — | 28,000 | |
| — | 100.00 | — | — | ||
| Trenching under Rails for crossing the track (Track Crossing) and refilling of trenches. The track crossing shall be done at right angles. The depth of the cable trench shall be 1.2 meter below the rail flange. The ballast shall be stacked separately while making the trench and the earth soil shall be stacked separately. While re-filling the trench, the earth soil has to be filled first to the ground level and the ballast has to be properly put in the track. This work has to be done under supervision of the supervisor of S&T. | — | — | — | 1,12,800 | |
| — | 20.00 | — | — | ||
| Alteration/modification in the existing location boxes (full size), fixing of equipment's, cable insertion, termination, wiring, testing & commissioning, two coat painting, lettering to suit the circuits as per approved wiring diagrams. This includes filling with sand and plastering the same. | — | — | — | 70,140 | |
| — | 2.00 | — | — | ||
| Supply of PVC insulated multi strand, single core copper conductor of size 16/0.2 mm as per RDSO Spec. No. IRS:S-76/89 (Amdt.-3) or latest. Each coil should be of Minimum 100 meters length. The color of the wire which is required will be specified by the Engineer in charge. Inspection: RDSO. | — | — | — | 21,266 | |
| — | 250.00 | — | — | ||
| Supply of Disconnect Terminal Block, Screw less type, 4-wire front entry (Two in-put & Two out-put) as per RDSO Spec. No. RDSO/SPN/189/2004 With latest amendments. The color will be decided by the Engineer - in - Charge. (Preferably In Blue, Red & Grey Colors in the ratio of 1:2:3) Inspection: RDSO | — | — | — | 17,250 | |
| — | 30.00 | — | — | ||
| Supply of End plate 2.5 mm./0.091 in thick RDSO/SPN/189/2004 With latest amendments. Inspection: RDSO | — | — | — | 390 | |
| — | — | — | RDSO | ||
| — | — | — | Spec. | ||
| — | 30.00 | — | — | ||
| Supply of End Stopper 10 mm./0.0394 in width as per RDSO Spec. No. RDSO/SPN/189/2004 With latest amendments. Inspection: RDSO. | — | — | — | 390 | |
| — | 10.00 | — | — | ||
| Supply of Carrier Rails for placing disconnect type terminal 35 mm. x 7.5 mm., 1 mm./0.039 in thickness un-slotted type as per site requirement. Inspection: Consignee. | — | — | — | 1,280 | |
| — | 30.00 | — | — | ||
| Supply of earth electrode (GI PIPE) as per CSTE/ER's (Drg. No. SI/TYP/0097 dated 25.03.25). Inspection: Consignee. | — | — | — | 56,580 | |
| — | 30.00 | — | — | ||
| — | 30.00 | — | — | ||
| — | 20.00 | — | — | ||
| — | 30.00 | — | — |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Modified_Cable_cut_JPO_NO._94.pdf Annexure I
ATTACHMENT
GCC_April-2022.pdf
ATTACHMENT
TenderDocument_SnT.pdf
ATTACHMENT
GCC Correction Slip1
ATTACHMENT
GCC Correction Slip2
ATTACHMENT
mergedGCCCorrectionslip3456.pdf GCC Correction Slip3456
ATTACHMENT
MergedGCCCorrectionSlip78910.pdf GCC Correction Slip78910
ATTACHMENT
GCCCorrectionslip11.pdf
ATTACHMENT
Modified_Cable_cut_JPO_NO._94.pdf
ATTACHMENT
2022_CE-I_CT_GCC-2022Policy14.07.2022.pdf
ATTACHMENT
ACS-2toGCC-2022_2022-CE-1-CT-GCC-2022-POLICY_13.12.20221.pdf
ATTACHMENT
mergedGCCCorrectionslip3456.pdf
ATTACHMENT
MergedGCCCorrectionSlip78910.pdf
ATTACHMENT
2018-CE-I-CT-9dtd.pdf
ATTACHMENT
Annexure-C.pdf
ATTACHMENT
AllAnnexure.pdf
ATTACHMENT
CheckList.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .