Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.6 LAccepted-AOC 55 SHALL TOKUNA JANGALNAD PULWAMA PULWAMA JAMMU KASHMIR 192301 | PULWAMA | JAMMU AND KASHMIR | 192301 | L1 | Accepted-AOC Being L1 Bidder | |
| 2 | L2₹11.5 L+₹66,098.93 (6.09%)Rejected-Finance | L2 | Rejected-Finance Rejected being other than L1 bidder | |
| 3 | L3₹11.8 L+₹98,062.90 (9.04%)Rejected-Finance 184 TENGPUNA PULWAMA PULWAMA PULWAMA JAMMU KASHMIR 192301 UDYAM JK 15 0009999 | PULWAMA | JAMMU AND KASHMIR | 192301 | L3 | Rejected-Finance Rejected being other than L1 bidder | |
| 4 | L4₹12.4 L+₹1.6 L (14.6%)Rejected-Finance | L4 | Rejected-Finance Rejected being other than L1 bidder | |
| 5 | L5₹13.0 L+₹2.2 L (19.8%)Rejected-Finance KOIL KOIL PULWAMA PULWAMA JAMMU KASHMIR 192301 | PULWAMA | JAMMU AND KASHMIR | 192301 | L5 | Rejected-Finance Rejected being other than L1 bidder |
| Sl No | Description | Qty | Unit | M/S BASHIR AHMAD AND SONS L3 | M/S ABBAS M. ENTERPRISES L4 | FG CONSTRUCTION L6 | M/S SHABIR AHMAD SHAH AND CO L1 | M/S MIR SAJAD ENTERPRISES L8 | nazir Ahmad Dar and sons L7 | M/s Gh Qadir and Sons L5 | M/S ABDUL RASHID AND CO L2 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply and installing in replacement of LED flood light 100 watt 230 V AC outdoor/indoor type with thermal management in multiple optics and equipped with IP66 protection, efficacy 120 lm/watt, with impact and corrosion resistant complete with driver and lamp including mounting arrangement i.e. GI bracket bend type made up from GI pipe 40mm size, complete all as specified and as directed. | 60 | Each | 5,900 ₹3,54,000 | 7,000 ₹4,20,000 | 2,500 ₹1,50,000 Lowest | 3,000 ₹1,80,000 | 5,600 ₹3,36,000 | 8,500 ₹5,10,000 | 7,000 ₹4,20,000 | 3,000 ₹1,80,000 |
| 2.00 | S&F in replacement of sheet metal steel plug & socket DB SP with metal clad 2 pin & earth plug and socket SPN, 20 Amps, 230 volts AC, surface mounting type complete with one MCB SP, 20 Amps, 10 kA complete all as specified. | 20 | Each | 1,200 ₹24,000 | 1,200 ₹24,000 | 890 ₹17,800 | 1,200 ₹24,000 | 730 ₹14,600 | 1,700 ₹34,000 | 650 ₹13,000 | 500 ₹10,000 Lowest |
| 3.00 | S&F in replacement of sheet metal steel plug & socket DB TPN with metal clad 5 pin & earth plug and socket TPN, 32 Amps, 415 volts AC, surface mounting type complete with one MCB TPN, 32 Amps, 10 kA complete all as specified. | 20 | Each | 1,200 ₹24,000 Lowest | 2,000 ₹40,000 | 2,300 ₹46,000 | 1,300 ₹26,000 | 2,150 ₹43,000 | 3,100 ₹62,000 | 1,200 ₹24,000 Lowest | 1,500 ₹30,000 |
| 4.00 | S&F in replacement of wiring for submain with FRLS PVC insulated unsheathed copper conductor cable, multi stranded, single core, FRLS type, 1100 volts grade 2 x 1.5 sqmm complete drawn in steel conduit fixed on the wall along with 1x 1.2 sqmm PVC insulated unsheathed copper conductor cable, multi stranded for continuous earth wire including making good the disturbed surface complete all as specified. Make:havells/polycab/Finolex | 500 | RM | 90 ₹45,000 | 120 ₹60,000 | 140 ₹70,000 | 110 ₹55,000 | 80 ₹40,000 | 200 ₹1,00,000 | 110 ₹55,000 | 47 ₹23,500 Lowest |
| 5.00 | S&F in replacement of wiring for submain with FRLS PVC insulated unsheathed copper conductor cable, multi stranded, single core, FRLS type, 1100 volts grade 2 x 4 sqmm complete drawn in steel conduit fixed on the wall along with 1x 4.0 sqmm PVC insulated unsheathed copper conductor cable, multi stranded for continuous earth wire including making good the disturbed surface complete all as specified. Make:havells/polycab/Finolex | 200 | RM | 220 ₹44,000 | 150 ₹30,000 | 160 ₹32,000 | 150 ₹30,000 | 190 ₹38,000 | 200 ₹40,000 | 150 ₹30,000 | 90 ₹18,000 Lowest |
| 6.00 | S&F in replacement of flameproof wiring for submain with FRLS PVC insulated unsheathed copper conductor cable, multi stranded, single core, FRLS type, 1100 volts grade complete drawn in steel conduit fixed on the wall along with PVC insulated unsheathed copper conductor cable, multi stranded for continuous earth wire including making good the disturbed surface complete all as specified of following size:-
(a) 4x6.0 RM + 1x6.0 RM | 200 | RM | 350 ₹70,000 | 200 ₹40,000 | 270 ₹54,000 | 300 ₹60,000 | 290 ₹58,000 | 300 ₹60,000 | 220 ₹44,000 | 190 ₹38,000 Lowest |
| 7.00 | S&F in replacement of factory made load line DB's double door verticle type made out of CRCA mild steel sheet with insulating material like polyester epoxy quoted surface mounting 4 way VTPN 415 volts, vertical type, surface mounting with suitable busbar, neutral link & earth link suitable for MCCB TP as incomer & MCB SP/TP as out going complete including MCCB 63-100 A four pole breaking capacity 16 kA for incoming complete all as specified. | 10 | Each | 3,300 ₹33,000 Lowest | 4,000 ₹40,000 | 4,500 ₹45,000 | 4,700 ₹47,000 | 14,500 ₹1,45,000 | 5,000 ₹50,000 | 4,500 ₹45,000 | 6,500 ₹65,000 |
| 8.00 | S&F in replacement of sheet metal enclosure DB SPN 2 way, single door, 230 volts AC, surface mounting complete suitable for MCB DP/SPN & MCB SP complete all as specified. | 10 | Each | 1,200 ₹12,000 | 300 ₹3,000 | 390 ₹3,900 | 300 ₹3,000 | 550 ₹5,500 | 450 ₹4,500 | 390 ₹3,900 | 200 ₹2,000 Lowest |
| 9.00 | S&F in replacement of sheet metal enclosure DB SPN 4 way, double door, 230 volts AC, surface mounting complete with suitable busbar, neutral link & earth link suitable for MCB DP/SPN as incomer & MCB SP as outgoing complete all as specified. | 10 | Each | 1,400 ₹14,000 | 1,000 ₹10,000 | 1,600 ₹16,000 | 700 ₹7,000 | 750 ₹7,500 | 1,300 ₹13,000 | 800 ₹8,000 | 270 ₹2,700 Lowest |
| 10.00 | S&F in replacement of sheet metal enclosure DB SPN 8 way, double door, 230 volts AC, surface mounting complete with suitable busbar, neutral link & earth link suitable for MCB DP/SPN as incomer & MCB SP as outgoing complete all as specified. | 6 | Each | 1,200 ₹7,200 | 1,300 ₹7,800 | 800 ₹4,800 Lowest | 1,000 ₹6,000 | 990 ₹5,940 | 1,700 ₹10,200 | 1,150 ₹6,900 | 1,600 ₹9,600 |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
9 Jul 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) AWANTIPUR
GE (AF) AWANTIPUR, C/O 8 FBSU, AF STN AWANTIPUR
CERTAIN REPAIR TO FITTING/FIXTURES TO HANGER AND BLAST PEN AND CONNECTED ITEMS AT AF STN AWANTIPUR
2025_MES_715234_1
GE (AF) AWA-24/2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (AF) AWANTIPUR
AS PER NIT AND TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
Yes
GE (AF) AWANTIPUR
₹40,000
Yes
4 Sept 2025
18 Jun 2025
11 Jul 2025
18 Jun 2025
9 Jul 2025
2 Jul 2025
Amount
Supply and installing in replacement of LED flood light 100 watt 230 V AC outdoor/indoor type with thermal management in multiple optics and equipped with IP66 protection, efficacy 120 lm/watt, with impact and corrosion resistant complete with driver and lamp including mounting arrangement i.e. GI bracket bend type made up from GI pipe 40mm size, complete all as specified and as directed.
S&F in replacement of sheet metal steel plug & socket DB SP with metal clad 2 pin & earth plug and socket SPN, 20 Amps, 230 volts AC, surface mounting type complete with one MCB SP, 20 Amps, 10 kA complete all as specified.
S&F in replacement of sheet metal steel plug & socket DB TPN with metal clad 5 pin & earth plug and socket TPN, 32 Amps, 415 volts AC, surface mounting type complete with one MCB TPN, 32 Amps, 10 kA complete all as specified.
S&F in replacement of wiring for submain with FRLS PVC insulated unsheathed copper conductor cable, multi stranded, single core, FRLS type, 1100 volts grade 2 x 1.5 sqmm complete drawn in steel conduit fixed on the wall along with 1x 1.2 sqmm PVC insulated unsheathed copper conductor cable, multi stranded for continuous earth wire including making good the disturbed surface complete all as specified. Make:havells/polycab/Finolex
S&F in replacement of wiring for submain with FRLS PVC insulated unsheathed copper conductor cable, multi stranded, single core, FRLS type, 1100 volts grade 2 x 4 sqmm complete drawn in steel conduit fixed on the wall along with 1x 4.0 sqmm PVC insulated unsheathed copper conductor cable, multi stranded for continuous earth wire including making good the disturbed surface complete all as specified. Make:havells/polycab/Finolex
S&F in replacement of flameproof wiring for submain with FRLS PVC insulated unsheathed copper conductor cable, multi stranded, single core, FRLS type, 1100 volts grade complete drawn in steel conduit fixed on the wall along with PVC insulated unsheathed copper conductor cable, multi stranded for continuous earth wire including making good the disturbed surface complete all as specified of following size:- (a) 4x6.0 RM + 1x6.0 RM
S&F in replacement of factory made load line DB's double door verticle type made out of CRCA mild steel sheet with insulating material like polyester epoxy quoted surface mounting 4 way VTPN 415 volts, vertical type, surface mounting with suitable busbar, neutral link & earth link suitable for MCCB TP as incomer & MCB SP/TP as out going complete including MCCB 63-100 A four pole breaking capacity 16 kA for incoming complete all as specified.
S&F in replacement of sheet metal enclosure DB SPN 2 way, single door, 230 volts AC, surface mounting complete suitable for MCB DP/SPN & MCB SP complete all as specified.
S&F in replacement of sheet metal enclosure DB SPN 4 way, double door, 230 volts AC, surface mounting complete with suitable busbar, neutral link & earth link suitable for MCB DP/SPN as incomer & MCB SP as outgoing complete all as specified.
S&F in replacement of sheet metal enclosure DB SPN 8 way, double door, 230 volts AC, surface mounting complete with suitable busbar, neutral link & earth link suitable for MCB DP/SPN as incomer & MCB SP as outgoing complete all as specified.
S&F in replacement of MCBs, SP, 6-32 Amps, 230 volts,10 kA rupturing capacity, B curve type complete all as specified.
S&F in replacement of MCBs, SPN, 32 Amps, 230 volts, 10 kA rupturing capacity, C curve type complete all as specified.
S&F in replacement of MCBs, TPN, 25-63 Amps, 415 volts, 10 kA rupturing capacity, B curve type complete all as specified.
M&L for fixing of air termination, single pointed aluminium rod 12mm dia and 300mm long on PCC block, complete all as specified and as directed. Note- Work include making of PCC block for mounting of Aluminium Spikes
Supplying and laying ,fixed to the wall GI tubing medium grade of size 25 mm bore for installation of the air termination rod on the top of it complete all as specified.
M&L for laying Aluminium strip 25 x 3.15mm with saddles, insulator ceramic for mounting of earthing and fixing screws etc. for roof conductors and down conductors above ground with complete accessories, complete all as specified and as directed.
Supply, laying or passing through pipe, in trench underground cable PVC sheathed, XLPE insulated armoured LT 1100 volts grade with aluminium conductor of size 35 Sqmm, 3.5 core including making electrical connection with thimbles complete all as specified.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for laying of cables or other items and getting out soil in soft/loose soil complete all as specifed.
Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm complete all as specified.
Removing excavated material not exceeding 50 mtr and depositing where directed in a level not exceeding 1.5 mtr above the starting point of any type of soil complete all as specified.
M&L for sand cushioning to under ground cable provided with a layer of sand 8 cm depth before laying of cable and 15 cm depth after laying and stretching the cable all as specified. Note: Punned thickness of sand shall be measured & paid.
M&L for well burnt sub class 'B' bricks of nominal size 230X115X75 mm abutting each other for mechanical protection of cable with width equal to lenght of brick complete all as specified.
Supplying and laying ,fixed to the wall GI tubing light grade of size 50 mm bore for cable protection complete all as specified.
M&L for plate earthing complete with galvanized mild steel plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (in earth pit not less than 2.25 meter deep below ground level) with the top edge of earth plate at a depth not less than 1.5 meter below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and including GI wire 4 mm bolted (with GI nuts, bolts & check nuts) and riveted to earth (Plate) electrode at one end and connected to main switch board /panel/ test point at the other including watering GI pipe (medium grade) 20 mm bore from bottom of earth pit to top of electrode and 20 mm GI pipe light grade for earth strip protection complete with earth pit in PCC 1:2:4 type B0 using 12 mm graded crushed stone aggregate, RCC cover, funnel, wire mesh including necessary excavation and earth work in any type of soil, returning filling in and removal of surplus soil complete all as specified.
M&L for Earthing complete with GI earth plate 600 x 600 x 6 mm thick buried directly in ground (earth pit not less that 2.25mtr deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to 32x6 mm GI strip as earthing lead by means of brazing after tighten by bolts, nuts, check nuts and washers from earth pit to test point with protection GI pipe of size 50mm dia light grade and providing masonry enclosure including watering GI pipe (medium grade) 20 mm bore from bottom of earth pit to top of electrode and 20 mm GI pipe light grade for earth strip protection complete with earth pit in PCC 1:2:4 type B0 using 12 mm graded crushed stone aggregate, RCC cover, funnel, wire mesh including necessary excavation and earth work in any type of soil, returning filling in and removal of surplus soil, complete all as specified and as directed. Note:- GI strip 7.5 mtr included in the quoted rate from earth pit to test point
Note :- An amount of Rs. 19,939.50 on account of credit schedule for Sch 'A' Part-II Shall be deducted from the total amount of BOQ to arrive at the contract sum.
M/S ABDUL RASHID AND CO (BID ID -3352153)
M/S BASHIR AHMAD AND SONS (BID ID -3346560)
M/S ABBAS M. ENTERPRISES (BID ID -3348826)
M/s Gh Qadir and Sons (BID ID -3344964)
FG CONSTRUCTION (BID ID -3349693)
nazir Ahmad Dar and sons (BID ID -3345463)
M/S MIR SAJAD ENTERPRISES (BID ID -3352270)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .