Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.0 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹17.4 L+₹1.2 L (7.42%)Rejected-Finance GANDHI CHOWK MANIPURA JAISALMER RAJ 345001 | JAISALMER | JAISALMER | RAJASTHAN | 345001 | L2 | Rejected-Finance Not being lowest | |
| 3 | L3₹17.5 L+₹1.3 L (7.92%)Rejected-Finance JAISALMER | BARMER | RAJASTHAN | 344001 | L3 | Rejected-Finance Not being lowest | |
| 4 | L4₹18.1 L+₹1.9 L (11.5%)Rejected-Finance JAISALMER | JAISALMER | RAJASTHAN | 342310 | L4 | Rejected-Finance Not being lowest | |
| 5 | L5₹23.8 L+₹7.6 L (46.8%)Rejected-Finance | L5 | Rejected-Finance Not being lowest |
Tender Value
Refer Docs
EMD Value
₹56,000
Closing Date
7 Aug 2021, 6:00 pmClosed
GE Army Jaisalmer
GE Army Jaisalmer 345001
Repair and cleaning of sewage line, septic tank and fencing and compound wall in Md Accn at Mil Stn Jaisalmer
2021_MES_458502_1
8121/21-22/E8
Open Tender
Civil Works
Item Rate
270 days
Jaisalmer
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE Army Jaisalmer
₹56,000
Yes
12 Oct 2021
9 Jul 2021
9 Aug 2021
9 Jul 2021
7 Aug 2021
23 Jul 2021
Amount
Cleaning of septic tank, man holes and inspection chamber etc. by means of removing the silt, sludge, excreta etc. or other materials, manually or mechanically and depositing the same, where directed at a distance not exceeding 150m including excavation of pits of required size to accommodate the foul materials taken out from septic tank, manholes, soakage pits and covering of the same with soil, not less than 30cm thick layer and making good all excavated site as required and as directed by Engineer-in-Charge. Note for item No. 1.00 :- (i) Depth of silt, sludge, excreta, etc shall only be measured and paid. (ii) Dewatering/pumping out of foul water shall be measured and paid separately.
Pumping out foul water from soakage wells/septic tank mechanically and removing sludge of capacity 10 users complete all as directed by Engineer-in-charge.
---- ditto --- all as per item No. 2.00 above but 20 users
---- ditto --- all as per item No. 2.00 above but 50 users
---- ditto --- all as per item No. 2.00 above but 100 users
---- ditto --- all as per item No. 2.00 above but 250 users
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in deep for foundation etc or for shaft, wells, cesspits, manholes, pier holes etc not exceeding 10 sqm on plan and getting out in soft/loose soil all as specified & directed by Engineer-in-Charge.
Excavation in trenches not exceeding 1.5m wide and exceeding 1.5m but not exceeding 3.00m depth for foundation etc or for shaft, wells, cesspits, manholes, pier holes etc not exceeding 10 sqm on plan and getting out in soft/loose soil all as specified & directed by Engineer-in-Charge.
Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick in any type of soil all as specified & directed by Engineer-in-Charge.
Removing excavated soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point all as directed.
Supply only integral water proofing compound in sealed pack (ISI marked) complet all as specified & directed by Engineer-in-charge.
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc.complete all as specified and directed
M&L for rendering 15 mm thick on stone masonry surface in cement mortar 1:4 including water proofing compound and finished even & smooth without using extra cement complete all as specified & directed by Engineer-in-charge (Note :-Supply only water proofing compound shall be measured and paid separately).
M&L for rendering 15 mm thick on stone masonry surfaces or surfaces other than fair faces of brick work or on one side of lathing in cement mortar 1:4 & finished the surface even & fair without using extra cement all as specified.
Demolition of cement concrete reinforced of any description and in any position not other wise specifically provided and removal unserviceable materials, debris and rubbish to a distance not exceeding 100m all as specified & directed by Engineer-in-charge.
Demolition and breaking up drain pipes (Salt glazed ware, AC or reinforced concrete) of 150mm bore set in cement mortar including demolition of packing under and hauching against sides of pipes complete all as directed by Engineer-in-charge. (Note :- Excavation and earth work shall be measured and paid separately.
--- ditto --- all as per item No. 16.00 above but of 200mm bore.
M&L for PCC (1:3:6) type C-2 using 40mm graded stone aggregate for concrete bed to drain pipes including packing under and haunching against the sides of pipe after they are laid and tested complete for 150mm bore pipe all as specified & directed by Engineer-in-charge.
--- ditto --- all as per item No. 18.00 above but of 200mm bore.
M&L for 150mm bore salt glazed stoneware drain pipes (ISI marked) laid in trenches and jointed in CM (1:1) and tested complete all as specified & directed by Engineer-in-charge.
--- ditto --- all as per item No. 20.00 above but of 200mm bore.
Dismantling of cast iron or reinforced concrete drain pipes 100 mm dia jointed in cement mortar complete all as specified & directed by Engineer-in-charge.
Dismantling of cast iron or reinforced concrete drain pipes 75 mm dia jointed in cement mortar complete all as specified & directed by Engineer-in-charge.
S&F, 100mm bore (sand cast pipe) soil, waste and vent pipes in any length with or without ears and jointing with cement & fixed to walls complelte all as specified & directed by Engineer-in-charge.
S&F , 75mm bore (sand cast pipe) soil, waste and vent pipes in any length with or without ears and jointing with cement & fixed to walls complelte all as specified & directed by Engineer-in-charge.
S&F in repair 100mm bore cast iron cowl (sand cast) all as specified & directed by Engineer-in-charge.
M&L for rendering 10 mm thick plaster in cement mortar (1:6) on fair faces of brick work or concrete surfaces of walls and finishing the surface even and smooth without using extra cement all as specified and directed by Engineer-in-charge.
S&F in repair, 110mm bore PVC (SWR) single socketed in any length with rubber ring joints & fixed to walls complete all as specified and directed by Engineer-in-charge.
S&F in repair, 75mm bore PVC (SWR) single socketed in any length with rubber ring joints & fixed to walls all as specified and directed by Engineer-in-charge.
S&F in repair, 75mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified & directed by Engineer-in-charge.
S&F in repair, 125mm/110mm dia PVC (SWR) gully trap, setting & jointing with solvent cement complete all as specified & directed by Engineer-in-charge.
S&F 100mm cast iron sanitary connection socket to fit WC outlet complete all as specified & directed by Engineer-in-charge.
Demolition floor hearth or wall tiling including cement mortar bedding and removing unserviceable materials, debris and rubbish to a distance not exceeding 100m complete all as specified & directed by Engineer-in-charge.
S&F glazed ceramic coloured joint free tiles of size 450mmx350mmx7mm/ hick on vertical surface such as skirting, dados, risers to steps etc set & jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles over and including 10mm thick backing coat in CM (1:4) all as specified and directed by Engineer-in-charge.
M&L for cement screed bed or bedding layer of cement mortar 1:4, 15mm thick for laying floor finishes complete all as specified and as directed by the Engineer in Charge.
M&L for non skid ceramic coloured jointless tiles of size 7 to 8mm thick (square/rectangular) area of each tiles exceeding 0.06 Sqm but not exceeding 0.11 Sqm, grade B-II (a) superior quality confirming to IS- 13755 as in floors etc set & jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles over and including screed bed or bedding layer of 15mm thick in CM (1:6) complete all as specified & directed by Engineer-in-charge.
Cleaning of choked sewage line of 100 mm bore of pipe including drains by rodding and well flushing with water, taking out waste materials any quantity and depositing where directed including covering the same with at least 30cm thick layer of soil all as directed by Engineer-in-Charge.
---- ditto --- all as per item No. 37.00 above but 150mm bore sewage line
---- ditto --- all as per item No. 37.00 above but 200mm bore sewage line
---- ditto --- all as per item No. 37.00 above but 250-300 mm bore sewage line
---- ditto --- all as per item No. 37.00 above but 300-600 mm bore sewage line
Cleaning of manholes not exceeding 1.5m deep by means of removing the silt, sludge, etc & bailing out foul water complete manually or mechanically and covering of the same with soil, not less than 30cm thick layer and making good all excavated site as required and as directed by Engineer-in-Charge.
Cleaning of manholes exceeding 1.5m but not exceeding 3m depth by means of removing the silt, sludge, etc & bailing out water complete manually or mechanically and covering of the same with soil, not less than 30cm thick layer and making good all excavated site as required and as directed by Engineer-in-Charge.
Note for item No. 37 to 43.00:- T&P or other machinery required for cleaning or dewatering are deemed to be included in the quoted rate of the respective items as in septic tank, soakage well, manhole, sewage line etc.
Cleaning of floor trap, gully trap in any size by means of removing the silt, sludge, etc & bailing out water complete manually or mechanically and removing the same out side MD land complete and making good all as directed by Engineer-in-Charge.
Blockage of WC/EWC in any type floor by means of removing the silt, sludge, etc & bailing out water complete manually or mechanically and removing the same out side MD land complete and making good all as directed by Engineer-in-Charge.
Blockage of urinal in any type floor by means of removing the silt, sludge, etc & bailing out water complete manually or mechanically and removing the same out side MD land complete and making good all as directed by Engineer-in-Charge.
Blockage of WHB in any type floor by means of removing the silt, sludge, etc & bailing out water complete manually or mechanically and removing the same out side MD land complete and making good all as directed by Engineer-in-Charge.
Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc. loaded bedded and pointed in any mortar complete all as specified & directed by Engineer-in-charge.
M&L sand stone slabs 10cm thick in sun-shades, chajjas, shelves, cills, landings, cover stones, templates, etc. n exc. 2m in length, punched dressed on face and along exposed edges, self faced on other side and set and pointed in lime mortar 1:2 or cement mortar 1:4. complete all as specified & directed by Engineer-in-charge.
Dismantling of posts or struts (wood, steel or RCC ) any section including taking out embeded portion and making good distrubed ground on concrete , brick work, masonry etc and removing of demolished materials out side MD land complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description specifically provided for gates, staircase railings, framed truss etc complete all as specified and directed.
M&L Mild framed works such as angles, tees , channels, etc as in fenching posts large and small gates and grills , gratings and chainlink fenching etc, including hanging gates in pillar with proper pintle hinges, stops, hand made sliding bolts ,etc complete all as specified & directed by Engineer-in-charge.
Dismantling fencing wire mesh, any type complete all as specified & directed by Engineer-in-charge.
Supply Chain link MS galvanisd fencing, any size or type compleate all as specified
Fixing only chain link MS galvanisd fencing, any size or type compleate all as specified
S&F mild steel round Bar 10 mm dia cut to length bent to shape as required, for fixing chain link fencing fixed with nut & bolt as in tie bar complete all as specified & directed by Engineer-in-charge.
S&F Mild steel flat iron for securing of chain link fencing conforming to Fe 290 Gde E-165 in post and strut in fencing including fabrication i.e. cutting tops drilling holes notching for wire welding etc..complete all as specified and directed.
S&F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut exc 15cm but not.exc 22.5 cm long,diameter of neck n exc12 mm complete all as specified and directed.
M&L for Preparation of new steel surfaces of any description over 10cm width or girth and application of two coats of synthetic enamel paint over one coat of red oxide primer etc,complete all as specified and directed.
Demolition of brick work /stone masonry built in cement mortar incl coping of any description all as specified and directed.
M&L squared rubble walling Jodhpur type, brought upto courses, well bonded, bedded and solidly hearted, built in cement mortar 1:6 complete all as specified and directed by Engineer-in-charge.
M&L squared rubble walling Jodhpur type, brought upto courses, well bonded, bedded and solidly hearted, built in cement mortar 1:6 but except stone complete all as specified and directed by Engineer-in-charge.
M & L for two coats of cement base paint over a coat of primer on new surfaces of wall complete all as specified and directed by Engineer-in-charge.
BHAGWATI CONSTRUCTION
M/s Shri Inder Construction Company
M/S MAYA CONSTRUCTION COMPANY
M/s B R Saran Kotda
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .