Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.8 LAccepted-AOC 3RD FLOOR BHAKTAMAR RESIDENCY SOMNATHNAGAR ROAD PUNE 411014 | PUNE | PUNE | MAHARASHTRA | 411014 | L1 | Accepted-AOC ACCEPTED BEING LOWEST BIDDER | |
| 2 | L2₹10.6 L+₹99,581.38 (10.4%)Rejected-Finance SHOP NO 259 LOHOGAON ROAD KALWAD KHANDVE NAGAR PUNE 411032 | PUNE | MAHARASHTRA | 411032 | L2 | Rejected-Finance REJECTED BEING NOT LOWEST BIDDER | |
| 3 | L3₹11.2 L+₹1.6 L (16.2%)Rejected-Finance | L3 | Rejected-Finance REJECTED BEING NOT LOWEST BIDDER | |
| 4 | L4₹14.1 L+₹4.5 L (47.0%)Rejected-Finance | L4 | Rejected-Finance REJECTED BEING NOT LOWEST BIDDER |
Tender Value
₹15.0 L
EMD Value
₹29,980
Closing Date
21 Dec 2023, 6:00 pmClosed
CWE KHADKI
Headquarters CWE Khadki, Military Engineer Services, Range Hills Road, Khadki, Pune-411003
REPAIRS TO HT DISTRIBUTION LINES, CHEMICAL EARTHINGS AND MAINTENANCE OF E/M INSTALLATIONNS INCLUDING REWINDING OF TRANSFORMERS, SERVICING OF HT BREAKER/ GOD AT INSP ORG UNDER GE (MH AND RH) KHADKI
2023_MES_629408_1
CWE/KKE/TOKEN-51 OF 2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
KHADKI
AS PER TENDER
6 documents required · 6 mandatory
₹500
Yes
GE MH AND RH KHADKI
₹29,980
Yes
22 Jan 2024
23 Nov 2023
25 Dec 2023
23 Nov 2023
21 Dec 2023
8 Dec 2023
24 Nov 2023 - 30 Nov 2023
Amount
S&F in replacement Switch Air break Gang operated HT 22 KV Volt grade out door type, triple pole of capacity 200 amps rating mounted on Polymer based 9 insulator and fitted on steel frame horizontally mechanically operated mechanism from ground level consisting of operating rod of 25 mm bore Heavy grade GI pipe of suitable length worked from ground level and with locking arrangements incl pad locks with key flat iron clamp 50 mm x 6 mm including taking down old unseviceable one complete. ( Make: Atlas /Jaipuria Brothers / MEC Trivandrum)
Supplying, installing, fixing, connecting and testing of polymer based Drop-out fuse set (set of 3 nos), mounted on insulators with steel frame 200 Amps capacity, siutable for 22 KV, HT system, out door type, including Expulsion fuse carriers and fuse element Upto 25 Amp, including taking down old unserviceable one complete. ( Make: Atlas /Jaipuria Brothers / MEC Trivandrum)
M&L for Lightning arrester high tension expulsion type complete in repair with all fittings transmission class, discharge capacity 30 Kilo amps suitable for 22000 Volts supply including taking down old lightning arresters complete ( Make: Elpro/ Jayshree / Mysore/Areva)
M&L for errecting in repair steel tubular swaged poles in true vertical position ( or to be fixed in an inclined positon as strut pole) steel tublar swaged poles complete with MS base plate of 6 mm thick of size 450x450 mm finial taper plug , pole cap,bolts ,nuts and washer and screwd pole made out of ERW MS tubing confirming to IS -2713 (part-II) 1980 type 410 SP-55 (11 meters long) pole including drilling of holes of required size any Nos for fixing of cross arms, painting with one coat of red oxide primer and two coats of aluminium paint for exposed surfaces and two coats of black bituminous paint for portion embeded in concrete , etc complete.(For 2 pole Structure) all as specified and directed
M&L in repair for cross arms, bracing, supports, clamps and back plates fabricated from structural steel section including nuts, bolts, washer, welding,bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat and one finishing coat of paint all as specified and directed by Engr in charge
M&L for anticlimbing device in repair, spike type fabricated out of MS bars( Round, Square And flat) including nuts bolts washers and welding in to halves made to shape to suite the cross section of the pole all as specified and directed.
M&L cement concrete 1 : 4 :8 type D2 , using 40 mm graded stone aggregate for PCC pole/struts, stay assembly, foundation filling and mass concrete all as directed by EIC.
M&L cement concrete 1 : 3 : 6 type C1, using 20 mm graded stone aggregate as in coping of pole etc all as pecified and directed .
M & L for detect HT 11 KV/22 KV cable fault for various size of cable with technician around the clock at CQA (FEE), CQE(EE), CQE(tech area) CQA (ME) , HT sub stations at all Insp Org area and other locations under GE (MH & RH) khadki detect the cable fault and necessary excavation of soil and refilling the soil, joint the faulty cable with new straight through joint kit, after jointing, testing, and charging of HT cable all as specified and directed by Engr-in-Charge. (Note: (i) Cable joint required size measured and paid separately (ii) Each job considered cable fault locator use in one day)
Taking down unserviceable damaged HT 22 KV,95 sqmm and 120 sqmm cable from the trench /pole/wall complete all as directed and specified. Note:- Earth work shall be measured and paid seprately under relevent item of schedule.
S&L of HT underground cable XLPE insulated, PVC bedded round wire armoured electric power cable heavy duty with stranded aluminium conductor 22000 volts grade and cross section area 95 sqmm 3 core confirming to IS 7098/(part-II) 1985 laid in trenches/passing through pipes or fixed on poles/wall/floor etc as specified
S&L of HT underground cable XLPE insulated, PVC bedded galvanised steel strip or wire armoured electric power cable heavy duty with stranded aluminium conductor 22000 volts grade and cross section area 120 sqmm 3 core laid in trenches/passing through pipes or fied on poles/wall/floor etc as specified
M& L for trimming of tree branches with in 2.0 mtr on either side of the electric line/ poles with suitable T & P and depositing the waste as directed .
M&L for cable route indicator made out of Cast iron of dia 100 mm embrosed with HT cable with 25mm x 5 mm GI flat of length 1 mtr including painting with two coats of synthetic enamel red colour paint over a coat of primer to exposed surfaces complete all as specified and directed by the Engineer-in-charge.
M&L for cleaning of MES electric supply installations/campus by surface dressing or trimming of natural ground to remove small unequalities (including removing vegetation/ shrubs/brush wood/under growth) and carrying away the rubbish to a distance of not exc 50 mtr away complete for the various sub stations. incl spray of herbsite
Supply, installation and commissioning of advance maintenance free system based earthing comprising of following accessories (a) Set of 04 Nos 3000 mm long, 17.0 mm dia earth electrode made of 99.99% copper circular rods with connect copper strip and electrode with the help of copper brazzing of incoming copper strips of size 25 x 3 mm of length as per site requirement upto Bus bar as decided by Engr - in-Charge and distance between each copper earth electrode is minimum 3 Meter . (b) Copper bus bar of size (300 x 25 x 6)mm act as test point connect with copper nuts and bolts with post insulator.(Nuts/bolts as required is included in the cost). (c) Poly propylene earth pit cover of size 300 x 300 mm (with safe working load 2000 Kg) - 04 Nos (d) Copper bus bar of size (250 x 50 x 6)mm exothermically welded with main earth electrode (e) Each pit filled with earth enhancement compound /chemical (Magnesium sulphate) only (min 75 Kgs/pit) all as specified.
(f) Required result of earthing less than 01 Ohm . If desired Ohmic value is not achieved then additional set of 1 No of 3000 mm long, 17.0 mm dia earth electrode made out of 99.9% copper rod with allied items, 01 x Pit cover, 01 x Sub bar as (d) above 75 Kg of chemical shall be provided by contractor without any extra cost to Govt. No price adjustment shall be made, if additional set is not required complete all as directed of Engr- in-charge (g) Necessary excavation work in any type of soil/strata, returning filling and removal of soil is included in the aquoted rates. (h) Site inspection for complete Earthing work is mandotry for the Contractor befour quoting the tender. No explanation/doubts will be entertained later. (j) Any damage done to govt property during the execution of work will be make good by the contractor at his own cost.
M&L for transformer Painting with two coat of synthetic enamel paint heat proof of same colour including preparation of old surfaces complete includuing writing the MES no in bold letter complete all as specified and directed by Engr in charge .
M&L for Painting on two pole structure with two coat of aluminum paint over red oxide paint after preparation of old surfaces , complete as existing complete all as specified and directed by Engr in charge .
M&L for Painting on four pole structure with two coat of aluminum paint over red oxide paint after preparation of old surfaces , complete as existing complete all as specified and directed by Engr in charge .
M&L for spray painting to exposed surface of steel tubular pole HT pole 11 Mtr long with two coats of synthetic enamel aluminium paint(as per existing color) over a coat of red oxide primer including preparation of old painted surface by scrapping or complete removal of old paint, filling cavities with filler complete all as directed
M&L for hardcore of gauge n.exc 63 mm ,deposited, spread, and levelled in layers n.exc 15 cm thickness (below or above ground level) ,water and rammed to a true shape with broken stone or boulders existing available on site and making good all as specified and directed by Engr-in-Charge.
M& L of Synthetic insulating mat confirming to IS 15652:2006 of size 2mx1m ,3 mm thick for voltage up to 22/33kv all as specified and directed by Engr in charge.
M & L for construction of brick masonary platform of size 2.0 m x 2.0 m x 1 m including necessary excavation and earth work in soft/loose soil , brick work,plastering, white wash, PCC work complete all as specified and as directed by Engineer-in-Charge. NOTE:- BELOW GROUND LEVEL:- (i) Sub base for brick wall shall be 10cm thick and 80cm width with concrete (1:4:8) type D-2 using 40mm graded stone aggregate. (ii) Brick wall all around shall be 0.69 cm thick built in cement mortar (1:4) for first 30cm height from PCC. (iii) Brick wall all around shall be 0.575 cm thick built in cement mortar (1:4) for next 30cm height from PCC.
ABOVE GROUND LEVEL:- (i) Brick wall all around shall be 46 cm thick built in cement mortar (1:4) for a height of 50 cm. (ii) 100mm thick PCC with concrete (1:4:8) type D-2 using 40mm graded stone aggregate. (iii) 150mm thick RCC slab on top with concrete (1:2:4) type B-1 using 20mm graded stone aggregate,12 mm MS bar C/C 100mm. (iv) Plastering 15mm thick with cement mortar 1:4 with fair finishing without using extra cement. (v) PCC (1:3:6) type C-2 as in plinth protector in width 75cm all around. (vi) The hollow portion will be filled with 40/63mm crushed stone. (vii) Two coats of white wash and preparation of newly plastered surface. Note :- The cost is inclusive of T&P charges required for dismantling the Transformer from the old platform and mounting it back to the new PCC platform.
Excavation in trenches n.exc 1.50 m wide and not exc 1.5 m depth and getting out in soft / loose soil complete all as specified and directed by engineer-in-Charge.
Excavation in trenches n.exc 1.50 m wide and not exc 1.5 m depth and getting out in hard / dense soil complete all as specified and directed by engineer-in-Charge.
Excavation in trenches n.exc 1.50 m wide and exc 1.5 m depth and getting out in soft disintegrated soil complete all as specified and directed by engineer-in-Charge.
Returing, filling in including spreading leveling, watering and well ramming in layers not exc 25 cm in soil all as specified and directed.
Removing excavated materials not exc 50m and depositing where directed at a level not exceeding 1.5m above the starting point.
M& L for crushed sand earth for cushioning to under groud cable in trenches including spreading, levelling hand punning and consolidate complete all as specified. Note : Punned down sand only shall be measured and paid.
S & L reinforced precast concrete cable cover, class EHV, type-1, peak of size 450mmx230mmx50mm laid in trench as protection to cable all as specified and directed.
M & L for road cutting for laying GI pipe for protection of cable upto depth 90 cm incl including making good the disturbed road and redressing the disturb surfaces of road with filling concrete type D-2 PCC in 1:4:8 (40 mm graded aggregate) complete all as specified and directed .(For HT/LT cable)
S & F GI pipe Light grade (ISI marked) in repair laid in trenches/ path /road crossings/ fixed to poles/ceiling/ along walls/ path /drain/floors with and including all necessary clamps, nuts, bolts, washers etc and all fittings as required, complete all as specified and as directed by the Engineer-in-Charge of following sizes :-
(a)100 mm bore
(b) 80 mm bore
Disconnecting the HV22 KV & LV (0.415KV ) side electrical connections including neutral earth strip of existing step down transformer, drain out the complete oil of transformer and store carefully in clean container. Cleaning of all HV/LV windings terminals, cleaning of conservator tank, cooling fins/tubes, tank, etc. Thuroughly inspecting of core and winding complete, reinsert the core coil assembly into the transformer tank, replacing 5/3 mm thick rubberised corksheet gasket of top cover complete and refilled with filtered transformer oil upto the desired level marked in conservator tank and record the insulation resistance of the winding both HV/LV side between earth and HV/LV winding, reconnecting the HV/LV side electric cables complete of following capacity of stepdown transformer. Note - Transformer oil filtration and top up shall be measured and paid seperately under the relevant item of schedule
Transformer capacity 100KVA to 250 KVA
Transformer capacity 300KVA to 500 KVA
M&L for dehydration of transformer oil with mobile stream line transformer oil filteration plant at site with all accessories connected to transformer and carrying out filterartion of oil to desired dielectric strenght to achieve electric strength of 60 KV for 1 minute at 2.5 mm gap as per relevant IS for transformer installed at various locations out door/in door type, all as directed by the Engineer in Charge Note : Test certificate shall be submitted for before and after filteration for dielectric strenght on the proper format. (ii) Transformer oil used for top up will be measured and paid seprately under relevant item.
Supply and topping up new transformer oil confirming to IS-335 of 1993 into the conservator tank/body tank of the transformer at various location complete all as directed by the Engineer-in-charge. (Make : Power Oil or its equivalent) Note : The transformer oil for topping up shall be with di-electric strength of 60KV
Disconnecting all in coming and outdoor cables removing the transformer from the platform/two pole structure and floor and loading it in th e vechicle carefully using the crane and transporting it to the workshop for repairs and transformer transport back to site , reinstall it, reconnecting all incoming and outgoing cable by properly crimping using lugs of suitable size taping the bushes/busbar, using insulation tape and testing of capacity 200 KVA to 500 KVA all as directed . Note :LT/HT side ceramic busing, brass spindle for HT/LT side , Rewinding , Dehydration of oil shall be measured and paid seprately in respective Items
M & L for rewinding of HT /LT windings of transformer , winding the defective coils with approved quality copper wire as per IS of same gauge and existing size together with new insulation materials, bracings the terminals before placing into the tranformer and assembling the HT / LT coil with new insulation between core and LT coil all as required and fitting the coils in the chamber, testing and commisioning the transformer after providing necessary connections complete all as directed by Engr in charge.
M & L for arrest the leakage of transformer oil From the LT/HT side bushings by replacing oil seals , Gaskets of , top cover , conservator tank and other parts of transformer after drain out the transformer oil at required level , tigtning the transformer nut bolts, replacing the gasket nuts , bolts , washer and refilling the strored Transformer oil after completion of oil arrest all as specifeid and directed By Engr in charge. Note : (i) Spare required such as nut ,bolts,washer,Gasket etc required to oil arrest shall be deemed in quoted rate. (ii) Topping up of extra transforemer oil required to achieve desired level will be measured and paid seprately. (iii) HT/LT side complete bushing assemble with brass stud & oil seal shall be measured & paid under relevent item of schedule.
Supply only HT side bushing 22KV complete with oil seal for 100 to 250 KVA
Supply only HT side bushing 22KV complete with oil seal for 300 to 500 KVA
Supply only LT side bushing 415V complete with oil seal for 100 to 250 KVA
Supply only LT side bushing 415V complete with oil seal for 300 to 500 KVA
Replacement of breather assembly complete with silica jel in transparent container with metallic top and bottom cup with pipe entry of 15/20 mm dia, including oil bath tub :-
Replacement of existing unserviceable silica gel with new crystal clear silica jel for breather of transformer all as directed.
Supply only brass spindle on LT side as per existing size, shape and specification for capacity range 200 KVA to 500 KVA , complete all as directed by the Engineer-in-charge.
Supply only brass spindle on HT side 22 KV as per existing size, shape and specification for capacity range 200 KVA to 500 KVA , complete all as directed by the Engineer-in-charge.
M & L for overhauling servicing of Tap changer and replacement of unserviceable parts as ordered with new and assembling with old serviceable parts for smooth functioning and operation complete as all specified and directed.
M & L for Servicing HT 22 KV HT RMU (Ring Main Unit), type - RM6, of capacity 630A/800A,22KV, 3 ph,50 Hz Panel, comprising the following works. Make-C&S (a) check the auxilliry switch,shunt trip assembly, closing/Trip solenoid,limit swtch and complete control wiring
Over hauling and testing of secondary injection of over current and earth fault relay of HT RMU 22 KV panel on each multiple setting , readjustment and calibration the same complete, checking of control wiring including testing on completion all as specified .
Supply only of the following material for VCBs/RMU Complete all as specified and as directed.
Charging motor, single phase working on 240 volts Ac
Closing/tripping coil operated on 110 /30 volt system
Tripping coil operated on 110 /30 volt system
loading Spring
latch switch assly
Space heater
Thermostat for Space heater
Refilling onsite SF6 Gas, required for 22 KV VCBs/RMUs
M & L for cable jointing kit for 22 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of following size and voltage grade including taking down old cable joint kit all as specified and directed by Engr-in-charge.
All as per item No 51 but of Size 95 sqmm x 3 core
All as per item No 51 but of Size 120 sqmm x 3 core to 185 Sqmm x 3 Core
All as per item No 51 but of Size 240 Sqmm 3 Core to 300 sqmm x 3 core
M & L for cable jointing kit for 22 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of following size including taking down old cable joint kit all as specified and directed by Engr-in-charge.
All as per item No 52 but of Size 95 sqmm x 3 core
All as per item No 52 but of Size 120 sqmm x 3 core to 185 Sqmm x 3 Core
All as per item No 52 but of Size 240 Sqmm 3 Core to 300 sqmm x 3 core
M & L for heat shrinkable HT 22 KV (earthed) straight through joint cable kit suitable for aluminium conductor cable of following size all as specified and Directed
All as per item No 53 but of size Size 95 sqmm x 3 core
All as per item No 53 but of Size 120 sqmm x 3 core to 185 Sqmm x 3 Core
M & L for cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm including taking down old cable joint kit all as specified and directed by Engr-in-charge.
M & L for heat shrinkable HT 11 KV (earthed) straight through joint 50 Sqmm to 95 Sqmm cable kit suitable for aluminium conductor cable of size upto 95 sqmm 3 core all as specified and Directed
M & L for cable jointing kit for 11 KV of Size upto 3 core 95 sqmm (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 Sqmm to 95 Sqmm including taking down old cable joint kit all as specified and directed by Engr-in-charge.
Rama Electricals
K K ENGINEERING SERVICES
SHREE VAIBHAV ELECTRICALS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .