GE RANGIA
GE Rangia C/O 99 APO Rangia
REPAIR, REPLACEMENT AND CLEANING OF SEWAGE LINE, MANHOLE, SEPTIC TANK AND OTHER CONNECTED WORK AT HATTIGOR MILITARY STATION UNDER GE RANGIA
2020_MES_376627_1
8407/E8
Open Tender
Civil Works
Item Rate
180 days
HATTIGOR
AS PER NIT
8 documents required · 8 mandatory
₹500
GE RANGIA
₹16,000
Yes
23 Nov 2020
11 Sept 2020
10 Oct 2020
11 Sept 2020
8 Oct 2020
26 Sept 2020
60 days
Amount
M&L for cleaning of septic tanks of any capacity with removing of sludges etc and carrying it to a distance exc. 100 m but not exc. 250 meters and depositing in ditches including necessary excavation and earth work in soft/loose soil for making ditches and refilling the ditches after the sludge are deposited with spreading and leveling of excavated soils in the ditches over the sludge, removing surplus soils to a distance not exc. 50m and supply and sprinkling bleaching powder over the area of ditches with one meter around complete all as per specified and as directed by Engineer-in-Charge.
All as per serial item No. 1 above but for cleaning of manholes of any size and depth.
M&L for cleaning of cast iron pipe 100mm dia (internal) by rodding carefully from water closet to first manholes/inspection chamber or cleaning eye and removing all blockage in pipe lines and well flushing with water including making good of leakage in joint wherever required in cement mortar (1:2) complete all as specified and directed by Engineer-in-Charge.
M&L for cleaning of salt glazed stone ware (SGSW) sewage pipe line of 150mm dia (internal) by rodding between intermediate/1st manholes to manholes or between manholes to septic tanks or between septic tank to soak pits to remove all blockage and well flushing with water including making good of leakage in joints wherever required in cement mortar (1:2) complete all as specified and directed by Engineer-in-Charge.
All as per serial item No. 4 above but salt glazed stone ware (SGSW) sewage pipe lines of 100mm dia (internal).
M&L for cleaning of blocked WC by using vaccum pump including opening & refixing/CI cover bend and branch pieces & finally clean it with water complete all as specified and directed by Engineer-in-Charge.
Demolition of brick work built in any cement mortar at foul position complete all as specified and directed by Engineer-in-Charge.
Demolition and breaking up including removing from site salt glazed stoneware pipe of 150mm bore (internal) with concrete bedding and haunching complete including necessary earth work as required complete all as specified and directed by Engineer-in-Charge.
Demolition of cement concrete (un-reinforced) as in ground floor and pavings not exc. 15cm thickness (below or above ground level) complete all as specified and directed by Engineer-in-Charge.
Demolition of Reinforced Cement Concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed by Engineer-in-Charge.
Dismantling mild steel work of any description not otherwise provided for complete all as specified and directed by Engineer-in-Charge.
S&F Mild steel work in framed work such as grills, gratings,framed guard bars, ladders etc., with ends of bars shouldered and/ or riveted, or forged into spikes, and similar work confirming to Fe 410 - O or Fe 310 - O complete all as specified and directed by Engineer-in-Charge.
M&L for pre-cast reinforced cement concrete (1:1.5:3) type A-1 with using 20mm graded crushed stone aggregate as in cover slabs of manholes, gully traps, septic tanks etc with plain faces set in cement mortar (1:4) complete all as specified and directed by Engineer-in-Charge.
M&L for brick work with sub class ‘B; bricks (using old size bricks) straight or curved on plan exc 6.00 meter mean radius built in cement mortar (1:6) at foul position complete all as specified and directed by Engineer-in-Charge.
S&F mild steel TMT bars 6mm to 8mm dia of grade 500+D cut to length bent to shape required including cranking, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia in reinforcement complete all as specified and directed by Engineer-in-Charge.
M&L for rendering 15mm thick in cement mortar (1:4) mixed with water proofing compound as per manufacturer's direction on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement at foul position complete all as specified and directed by Engineer-in-Charge. (Note - WPC shall be measured and paid separately).
M&L for cement concrete bed to drain pipe 150mm bore (Internal) in cement concrete (1:3:6) type C-2 with using 40mm graded crushed stone aggregate including packing under and haunching against the sides of pipes after they are laid and tested complete all as specified and as directed by Engineer-in-Charge.
M&L for 150mm dia (internal) salt glazed stone ware drain pipes (Grade A) ISI Marked as in sewage lines laid in trenches and jointed complete all as specified and as directed by Engineer-in-Charge.
M&L for reinforced concrete pipes of dia 300mm class NP2, laid and jointed complete with collars complete all as specified and as directed by Engineer-in-Charge.
M&L for PCC (1:2:4) type B-1 ( using 20 mm grade crushed stone aggregate) as in benching, copping complete all as specified and as directed by Engineer-in-charge.
M&L for PCC (1:4:8) type D2 ( using 40mm graded crushed stone aggregate) as in foundation, filling and mass concrete complete all as per specified and as directed by Engineer-in-charge.
Taking down rainwaters pipes of any size or pattern including all fittings heads, shoes, bends, etc including cleaning or refixing or removal to store ( measured overall as fixed along the centre line over fittings and accessories) complete all as specified and as directed by Engineer-in-Charge.
S&F PVC (SWR) pipes of 110mm bore single socketed, in any length with rubber ring joints, laid in trenches or in floor complete all as specified and as directed by Engineer-in-Charge.
S&F 110 mm PVC (SWR) bends complete all as specified and as directed by Engineer-in-Charge.
Supply only integral water proofing compound ISI marked complete all as specified and as directed by Engineer-in-charge. Note:- The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender, from total amount of Schedule 'A'/BOQ.
RAJKAMAL ENTERPRISE
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .