Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹12.6 L
EMD Value
₹25,000
Closing Date
11 Feb 2026, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE ECMC ETPS
office of SE ECMC ETPS Kasimpur Aligarh UP 202127
Water supply, sanitation and Miscellaneous Civil work at 1x660 MW Harduaganj Thermal Power Station, Kasimpur Aligarh
2026_RVUNL_1109822_1
14/ECMC/CMD-II/ETPS/HTPS/2025
Open Tender
Civil Works
Percentage
90 days
Harduaganj ETPS Kasimpur Aligarh UP
AS PER TENDER DOCUMENTS
3 documents required · 3 mandatory
₹1,416
SAO EPAD HTPS KASIMPUR
₹25,000
4 Feb 2026
28 Jan 2026
13 Feb 2026
28 Jan 2026
11 Feb 2026
28 Jan 2026
28 Jan 2026 - 11 Feb 2026
Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of430x260x350 mm or 340x410x265 mm sizes respectively. (DSR No. 17.23)
Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth. (Granite Stone of approved shade ) (DSR No. 8.10.2)
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approve with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. (DSR No. 17.31)
Providing and fixing soil, waste and vent pipes:17.35.1 100 mm dia 17.35.1.1 Sand cast iron S&S pipe as per IS: 1729 17.35.2 75 mm diameter 17.35.2.1 Sand cast iron S&S pipe as per IS: 1729 (DSR No. 17.35.2.1)
Providing and fixing 100 mm sand cast Iron grating for gully trap. (DSR No. 17.29)
Providing and fixing plain bend of required degree. 17.39.1 100 mm dia 17.39.1.1 Sand cast iron S&S as per IS - 1729 (DSR No. 17.39.1.1)
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :(610x510 mm bowl depth 200 mm ) (DSR No. 17.10.2.1)
Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. 17.69.1 Waste coupling 31 mm dia of 79 mm length and 62 mm breadth weighing not less than 45 gms (DSR No. 17.69.1)
Waste coupling 38 mm dia of 83 mm length and 77 mm breadth, weighing not less than 60 gms (DSR No. 17.69.2)
Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors: 17.60.2 100 mm inlet and 75 mm outlet 17.60.2.2 Sand Cast Iron S&S as per IS- 1729 (DSR No. 17.60.2.2)
Providing and fixing door piece, insertion rubber washer 3 mm thick, bolts & nuts complete: 100 mm 17.55.1.2 Sand cast iron S&S as per IS - 3989 (DSR No. 17.55.1)
Providing and fixing unplasticised PVC connection pipe with brass unions: 18.21.2 45 cm length18.21.2.1 15 mm nominal bore (DSR No. 18.21.2.1)
Providing and laying S&S Centrifugally Cast (Spun) / Ductile Iron Pipes conforming to IS: 8329 :18.72.2 150 mm dia Ductile Iron Class K-7 pipes (DSR No. 18.72.2)
Providing and fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws, including excavation, refilling the earth or cutting of wall and making good the same complete wherever required. 15 mm nominal bore (DSR No. 18.47.1)
Providing and fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws, including excavation, refilling the earth or cutting of wall and making good the same complete wherever required. 20 mm nominal bore (DSR No. 18.47.2)
Providing and fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws, including excavation, refilling the earth or cutting of wall and making good the same complete wherever required. 25 mm nominal bore (DSR No. 18.47.3)
Providing and fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws, including excavation, refilling the earth or cutting of wall and making good the same complete wherever required. 32 mm nominal bore (DSR No. 18.47.4)
Providing and fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws, including excavation, refilling the earth or cutting of wall and making good the same complete wherever required. 40 mm nominal bore (DSR No. 18.47.5)
Providing and fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws, including excavation, refilling the earth or cutting of wall and making good the same complete wherever required. 50 mm nominal bore each 1118.30 (DSR No. 18.47.6)
15 mm nominal bore, 80 mm long, weighing not less than 46 gms (DSR No. 18.57.2)
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. (110 mm diameter) (DSR No. 12.41.2)
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 150 mm nominal inner dia Pipes) (DSR No. 18.9.10)
Cleaning of C.I down pipe from roof to bottom including all labour T&P complete dismantling and refixing complete (NSI)
Searching, sorting out and attending leakage and choking faults in external or internal running water mains, sever lines of different diameters at all elevations from 0 to 18 mm level including all materials as G.I bend , elbow, tee, socket, nipple etc. and supply of all labour, T&P such as thread cutting, dye, bunch voce, hacksaws pipe wrench etc. (NSI)
Rewinding of 5.00 to 7.5 H.P capacity three phase vertical or horizontal motor for pump of tubewell with class B insulated copper wire of I.S.I approved quality including painting varnishing etc. complete as per direction of E/I (NSI)
Attending complaints such as replacement of taps, washers, spindle for pillar cocks etc. by providing plumper at the complaints office including all labour T&P threads, safeda etc. required for proper completion of the work. (NSI)
P/F G.I. Pipes complete with G.I. Fittings & Clamps including cutting & making good the walls etc. (Internal work) 15mm dia Nominal bore.) (DSR No. 18.10.1)
P/F G.I. Pipes complete with G.I. Fittings & Clamps including cutting & making good the walls etc. (Internal work) 20mm dia Nominal bore.) (DSR No. 18.10.2)
Providing and fixing G.I. pipe complete with G.I. fittings including trenching and refilling etc. for external work 15 mm dia nominal bore (DSR No. 18.12.1)
Providing and fixing G.I. pipe complete with G.I. fittings including trenching and refilling etc. for external work 20 mm dia nominal bore (DSR No. 18.12.2)
Providing and fixing G.I. pipe complete with G.I. fittings including trenching and refilling etc. for external work 25 mm dia nominal bore (DSR No. 18.12.3)
Providing and fixing G.I. pipe complete with G.I. fittings including trenching and refilling etc. for external work 32 mm dia nominal bore (DSR No. 18.12.4)
Providing and fixing G.I. pipe complete with G.I. fittings including trenching and refilling etc. for external work 40 mm dia nominal bore (DSR No. 18.12.5)
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work 50 mm dia nominal bore (DSR No. 18.12.6)
Making connection of 25 to 40mm nominal bore G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete.(DSR No. 18.13.1)
P/F gun metal gate valve with C.I. wheel of approved quality (screwed end) 25 mm dia nominal bore (DSR No. 18.17.1)
P/F gun metal gate valve with C.I. wheel of approved quality (screwed end) 32 mm dia nominal bore (DSR No. 18.17.2)
P/F gun metal gate valve with C.I. wheel of approved quality (screwed end) 40 mm dia nominal bore (DSR No. 18.17.3)
Dismantling of 100mm dia old SW Pipe line including braking of joint & bed concrete, stacking of useful material near the site within 50Mtr. lead & disposal of unserviceable material in nearest dumping place. (DSR No. 19.5.1)
P/F white vitreous china flat back wash basin size 630x450 mm including making all connection but excluding cost of fitting. (DSR No. 17.25.2)
P/F 10 liter capacity- white PVC low level flushing cistern with manually controlled device (handle lever) conforming to IS: 7231 with all fittings and fixtures complete. (DSR No. 17.18.1)
P/F 15mm nominal ball valve (brass) of approved quality, high or low pressure, with plastic floats complete (DSR No. 18.18.1)
P/F Orissa pattern W.C. pan of size 580X440mm white vitreous china water closet squatting pan. (DSR No. 17.13.2)
Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : (W.C. pan with ISI marked black solid plastic seat and lid.) (DSR No. 17.3.2)
P/F P.V.C. waste pipe 32mm dia for sink or wash basin including P.V.C. waste fittings complete including west fittings complete. (DSR No. 17.28.1.1)
P/F on wall face unplasticised rigid PVC rain water pipes conforming to IS: 13592 type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion (i) single socketed pipes 110mm diameter (DSR No. 12.41.2)
P/F MS holder bat clamps of appd. Design to CI/SCI/AC rain water pipes embedded in and including cement concrete Blocks 10X10X10mm of 1:2:4 mix (1cement 2 coarse sand and 4 stone ballast) including cost of cutting holes and making good the wall complete. For 110 dia pipes. (DSR No. 17.37.1)
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms each 555.35 (DSR No. 17.73.1)
Providing and fixing toilet paper holder : C.P. brass each 583.75 (DSR No. 17.34.1)
Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. (DSR No. 17.71)
P/F PTMT pillar cock of approved quality & colour.15mm nominal bore, 86 mm long, weighing not less than 88gms. (DSR No. 18.54.1)
P/F PTMT pillar cock of approved quality & colour.15mm nominal bore, 107mm long, weighing not less than 110gms. (DSR No. 18.56.1)
Cleaning of Septic Tank chambers & disposal of malwa outside the boundary wall of colony/ power house. (NSR)
Cleaning of Inspection Chamber & disposal of malwa outside the boundary wall of colony/ power house. (NSR)
P/F 30 cm. length/ 15mm nominal size uplasticised PVC connection pipe with brass unions (DSR No. 18.21.1.1)
Providing and placing on terrace (at all floor levels) capacity polyethylene 500/1000litter water storage tank ISI: 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank (DSR No. 18.48)
P/F PTMT stop cock of approved quality & colour 15mm nominal bore, 86mm long weighing not less than 88gms. (DSR No. 18.55.1)
-do- but CI bib cock. (DSR No. 18.54.1)
P/F brass bib cock 15mm nominal size of approved quality. (DSR No 18.15.1)
-do- but stop cock (DSR No. 18.16.1)
P/F 15mm nominal bore C.P. Brass bib cock of approved quality conforming to IS:8931 (DSR No. 18.49.1)
P/F C.P. brass stop cock ( concealed) of standard design and approved of 15mm nominal bore (DSR No. 18.52.1)
Earth work in excavation over areas exceeding 30 cm. In depth 1.5M in width as well as 10 Sqm On plan) including disposal of excavated earth, lead upto 50M and lift upto 1.5M disposed earth to be leveled and neatly dressed. All kind of soil. (DSR No. 2.6.1)
P/L in position cement concrete 1:4:8 ( 1 cement : 4 coarse sand 8 graded stone aggregate 40mm nominal size) excluding the cost of centering and shuttering- all work up to plinth level. (DSR No. 4.1.8)
R.C.C. work in beams, suspended floors, roofs having bands, plain window sills, staircase and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement with 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) (DSR No. 5.3)
Steel reinforcement for RCC work incl. straightening cutting bending binding placing in position all complete upto plinth level with TMT bars (DSR No. 5.22.6)
12mm thick cement plaster of mix 1:6 (1cement : 6 coarse sand ) (DSR No. 13.4.2)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering-all work up to plinth level 1:2:4 ( 1 cement 2 coarse sand 4 graded stone aggregate 20mm nominal size) (DSR No. 4.1.3)
40mm thick with 20 mm nominal size stone aggregate cement concrete flooring in 1:2:4 (1cement: 2 Coarse Chambal red Sand : 4 graded stone aggregate ) finished with floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. complete.(DSR No. 11.3.1)
Centering and shuttering including strutting, propping etc. and removal of form for foundations, footings, bases of columns etc. for mass concrete. (DSR No. 5.9.1)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) (DSR No. 6.1.2)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) (DSR No. 6.4.2)
Cleaning of old bricks recovered from demolition of old brickwork by removing mortar, lumps and any other loose material from bricks and making good for use in masonry. (NSI)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand) ( Old brick provided by department) (NSR)
Tractor with trolley for transportation of Brick from 1x660 M.W. HTPP Kasimpur and other misc. work in plant (DSR No. 0039)
Demolishing brick work in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 Mtr. Lead (DSR No. 15.7.4)
Dismantling of old plaster skirting racking out joint and cleaning the surface for plaster incl. disposal of rubbish to the dumping ground within 50 mtrs lead. (DSR No. 15.56)
Demolishing RCC work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 mit lead as per direction of engineer-in-charge (DSR No. 15.3)
Carriage of earth and rubbish and concrete waste by mechanical transport including loading, unloading and stacking upto lead 3 km (DSR No. 1.1.2)
P/F 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by E/I, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement:3 coarse sand) and jointing with grey cement slurry @3.3 kg per sqm, incl. pointing in white cement mixed with pigment of matching shade complete. (DSR No 11.36)
P/F ceramic glazed floor tiles of size 300X300 mm (thickness to be specified by manufacturer) of 1st quality conforming to IS: 15622, of approved make in colours such as white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) incl. pointing the joints with white cement and matching pigment etc. complete. (DSR No. 11.37)
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption's less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement and matching pigments etc., complete of size of tile 600X600 mm (DSR No. 11.41.2)
Front end loader 1 cum bucket capacity (incl POL) (DSR No. 0052)
Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. (DSR No. 10.1)
Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. Steel provided by department (NSR)
Providing and laying GP 2 grouting (NSI)
For sealing cracks and faulty construction joints, routed out/making U-shape groove size 25x25mm and then primed the area with integral crystalline slurry @0.05kg/ running metre and while the surface is tacky filled the groove upto surface with crystalline mortar @1.50kg/ running metre. Once crystalline mortar is touch dry then finally applied two coats of integral crystalline slurry @0.05kg/running metre per coa.(22.25.1 )
P/F ISI marked 30 mm thick door shutters conforming to IS: 2202 non-decorative type including ISI marked stainless steel butt hinges with necessary screws, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands (DSR No. 9.21.2)
Renewing glass panes, with putty and nails, wherever necessary incl. racking out old putty. Float glass panes of thickness 4.0 mm (DSR No. 14.5.1)
Re-fixing old glass panes with putty and nails (DSR No 14.10)
Fencing with angle iron/ boiler tube post placed at required distance embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with horizontal lines and two diagonals interwoven with horizontal wires, of barbed wire 9.38 Kg. per 100m (minimum) between the two posts fitted and fixed with G.I. staples, turn buckles etc. complete (cost of posts, struts, earth work and concrete work to be paid for separately) :- payment to be made per meter cost of total length of barbed wire used. With G.I. barbed wire (DSR No. 16.18.1)
Welding by gas or electric plant including transportation of plant at site etc. complete.(DSR No. 10.22)
Fixing of door chaukhat in existing opening including embedding chaukhats in floor or walls or cutting masonry for hold fast in C.C. block with cement concrete In 1:3:6 (1 cement, 3 coarse sand, 6 graded stone Aggregate 20mm nominal size), painting 2 coats of coal tar 2 sides of chaukhat & making good the damages in walls or floor as required complete. (DSR No. 14.2.1)
Same as above but window chaukhat (DSR No.14.2.2)
P/F hard drawn steel wire fabric 75x25mm mesh of weight not 7.75 Kg. per Sqm to window frames etc including 62x19 mm beading of IInd class Teak wood. (DSR No. 9.50)
P/F IS3564 marked aluminum die cast body tubular type universal hydraulic door closer with necessary accessories and screws etc. complete. (DSR No. 9.83)
P/F fly proof galvanized M.S. wire gauge to windows and clerestory windiws using wire gauge with average width of aperture 1.4mm in both direction with wire of dia .63mm all complete. With 12mm M.S.U beading. (DSR No. 9.51.2)
P/F ISI marked oxidized M.S. sliding door bolts with nuts and screws etc. complete : 300x16 mm (DSR No. 9.62.1)
P/F ISI marked oxidized M.S. sliding door bolts with nuts and screws etc. complete : 250x16 mm (DSR No. 9.62.2)
Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. (DSR No. 9.82)
Providing and fixing ISI marked oxidized M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete : 250x10 mm (DSR No. 9.63.1)
Providing and fixing ISI marked oxidized M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete : 200x10 mm (DSR No. 9.63.2)
Providing and fixing ISI marked oxidized M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete : 150x10 mm (DSR No. 9.63.3)
Providing and fixing ISI marked oxidized M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete : 100x10 mm (DSR No. 9.63.4)
P/F ISI marked oxidized M.S. handles conforming to IS:4992 with necessary screws etc. complete : 125 mm (DSR No. 9.66.1)
P/F ISI marked oxidized M.S. handles conforming to IS:4992 with necessary screws etc. complete : 100 mm (DSR No. 9.66.2)
P/F ISI marked oxidized M.S. handles conforming to IS:4992 with necessary screws etc. complete : 75 mm (DSR No. 9.66.3)
Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing and paneling to be paid for separately) : For fixed portion Anodized aluminium (anodized transparent or dyed to required shade according to IS:1868, Minimum anodic coating of grade AC 15) (DSR No. 21.1.1.1)
P/F double action hydraulic floor spring of approved brand and manufacture conforming to IS: 6315 having brand logo embossed on the body/plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors , embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece MS sheet outer box with slide plate etc. complete as per direction of E/I With stainless steel cover plate minimum 1.25 mm thickness (DSR No. 21.4.1)
Filling the gap in between aluminium frame and adjacent RCC/Brick/Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of E/I complete upto 5 mm depth and 5 mm width (DSR No. 21.8.1)
Providing carpenter IInd class. (DSR No. 112)
Attending complaint regarding aluminium work of door/window/partition including all labour, material T&P, Fitter and helper (NSR)
Pumping out water caused by springs, tidal or river seepage, broken water mains or drains and the like.
Providing and applying white cement based putty of 1mm thickness over plastered wall surface to prepare the surface even and smooth complete (DSR No. 13.8)
Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. (DSR No. 13.91)
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :Old work (one or more coats) . (DSR No. 13.90.1)
Finishing walls with water proofing cement paint of required shade : New work (Two or more coats applied @ 3.84 kg/10 sqm) (DSR No. 13.44.1)
Painting on G.S. sheet with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : New work (two or more coats) including a coat of approved steel primer but excluding a coat of mordant solution. (DSR No. 13.53.1)
White washing with lime to give an even shade: New work (three or more coats) (DSR No. 13.37.1)
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : One or more coats on old work. (DSR No. 13.99.1)
Lettering with black Japan or approved paint of approved band and manufacture. (DSR No. 13.71)
1.O peration and maintenance of sewage treatment plant of capacity ( 0.03MLD) 30 M3 per day with proper operation of various equipments like air blower motor,dual media filter pump,sludge feed pump, with motor ,centrifuge with motor,centrifuge panel,Hypochlrite dosing pump with motor,pe dosing pump with motor,vertical submersible pump and motor including transfer of sewage from various location of plant and other misc. works as per guideline of Engineer-in-charge for adequate O&M of sawage treatment plant including mechanical/electrical/instrument maintenance, with cost of labour, material, T&P and tools & tackles etc. as per requirments,Vendor should maintain the operation parameters as per pollution control board like COD, BOD, TSS, Oil & Grease, MLVSS etc.
Routine operating and backwashing /cleaning of ACF, DMF, Tube Settler , FAB Reactor etc periodically.
Maintenance & upkeep and repair if necessary of following mechanical and electrical machine including piping installed with different points of sewage treatment plant including removal and replacement of unserviceable part and providing accessories/spares as an when required oiling and greasing etc. required for proper functional efficiency and performance of sewage treatment plant including all labour, materials and T&P etc. required for proper completion of job Mechanism of chlorination (1 Nos.)
Disposal of moorum/building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of Engineer-in-charge
periodic Cleaning of all tank including disposal of waste out side the plant area as per direction of E/I including cost of all labour T&P etc. required for proper completion of the work.
Pumping out sewage from manholes/ sewer line/ surface drain including cost of all materials. Labour & T&P etc. required for proper completion of work by deploying 5HP diesel pump.
Cleaning of choking of pipes/ sewer pipes of following internal dial byroding from manholes and well flushing after cleaning, including opening and closing of manhole covers and disposal of sludge with 50mtr lead at specified place including cost of all material, labour and T&P etc required for proper completion of work (one no. will be considered for cleaning of particulars dia of pipe lines between two manholes.100mm dia
Periodical oiling/greasing work, filling of gear oil in gear box and attending maintenance work of sewage treatment plant of capacity (0.03MLD) including complete routine break down maintenance of pumps with moter of 60HP 2Nos. 05HP 02 Nos. 02HP 2 No. 1HP installed at STP including alignment of pump with motor its coupling, cost of accessoires/ spares, consumable oil and grease etc. but excluding the cost of shaft bearing, gear, casing, pump coupling, rewinding motors etc. the work includes cleaning and minor maintenance of all valves, NRV etc,. like change of glands, packing, gaskets, bolts & nuts etc. and including cost of all material, labour and T&P etc. required for proper completion of work.
Rewinding of following capacity three phase vertical or horizontal motor for pump etc. with 'B' class insulated copper wire of ISI approved quality including painting, varnishing etc. complete with fiber replacement sleeve for insulation and nuts, bolts, washer etc. all the waste material such as burnt copper wire shall be the property of the contractor.5HP to 2 HP.
Rewinding of following capacity three phase vertical or horizontal motor for pump etc. with 'B' class insulated copper wire of ISI approved quality including painting, varnishing etc. complete with fiber replacement sleeve for insulation and nuts, bolts, washer etc. all the waste material such as burnt copper wire shall be the property of the contractor. 1HP
stage.html
html • 0.02 MB
cancelled_1.pdf
pdf • 1.81 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.04 MB
tenderspecificationET14.pdf
Tender Documents • 0.47 MB
BOQ_2049608.xls
BOQ • 0.41 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .