Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.2 LAccepted-AOC NO 235 PSK ILLAM SANKARAN NAGAR CHINNAMMAN KOIL STREET AVADI CHENNAI 600 054 | CHENNAI | THIRUVALLUR | TAMIL NADU | 600054 | L1 | Accepted-AOC Being lowest tenderer | |
| 2 | L2₹8.9 L+₹44,505.40 (5.24%)Rejected-Finance 27 1ST STREET PERIYAR NAGAR 1ST STREET PERIYAR NAGAR ADAMBAKKAM KANCHIPURAM TAMIL NADU 600088 | CHENNAI | TAMIL NADU | 600088 | L2 | Rejected-Finance Being other than lowest tenderer | |
| 3 | L3₹9.5 L+₹1.0 L (12.1%)Rejected-Finance NO 5 3 JJ KHAN ROAD 1ST LANE ROYAPETTAH CHENNAI 600 014 | CHENNAI | TAMIL NADU | 600014 | L3 | Rejected-Finance Being other than lowest tenderer | |
| 4 | Rejected-Technical D NO 32 1 211 2 BOWDARA ROAD VISAKHAPATNAM 530004 | VISAKHAPATANAM | ANDHRA PRADESH | 530004 | - | Rejected-Technical Not meeting eligibility criteria |
Tender Value
₹9.6 L
EMD Value
₹19,300
Closing Date
1 Apr 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Shri. Narinder Singh, IDSE, SE(SAG)
COMMANDER WORKS ENGINEERS CHENNAI PALLAVAN SALAI CHENNAI 600 002
86476E8 SPL RPRS TO EXT ELECTRIC WORKS AT MH AND DEFENCE COLONY AREA UNDER GE STM CHENNAI
2021_MES_428687_1
86476E8
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
STM CHENNAI
AS PER NIT
9 documents required · 9 mandatory
₹500
GE STM CHENNAI
₹19,300
Yes
20 May 2021
6 Mar 2021
3 Apr 2021
6 Mar 2021
1 Apr 2021
20 Mar 2021
6 Mar 2021 - 12 Mar 2021
60 days
Amount
BOQ UPLOADED ON 06 Mar 2021
SCH "A" PART-I (EXTERNAL ELECTRIFICATION)
Excavating in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc not exceeding 10 sqm on plan and not exceeding 1.5m depth and getting out in any type of soil all as specified and as directed.
Excavating in trenches, not exceeding 1.5m wide and exceeding 1.5m but not exceeding 3.0m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc not exceeding 10 sqm on plan and exceeding 1.5m but not exceeding 3.0m in depth and getting out in any type of soil all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in any type of soil complete all as specified and as directed.
Dry river sand laid to required width of trench at bottom and top for cable cushioning all as specified and as directed.
Punned thickness only shall be measured.
Removing excavated surplus soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed.
Plain cement concrete 1:3:6 type C1 using 20mm graded stone aggregate as in coping of poles and similar work complete all as specified and as directed.
Plain cement concrete 1:4:8 type D2 using 40mm graded stone aggregate as in foundation of poles, stay assembly complete all as specified and as directed.
Removing old cable cover in any condition and taken on credit and provision of Un-reinforced pre-cast concrete cable cover, class HV, type-I, flat, size 300mm x 180mm x 40mm for protection of cable in trenches complete all as specified and as directed.
Taking out existing cable any type / cross section 120 sqmm and Supply, laying, connecting and testing HT UG cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with aluminium conductor, 11000 volts grade, (Earthed), 3 core, cross sectional area 120 sqmm in bridges / culvert / trenches / drawn through pipe / fixed on walls / bare in road crossings / paths / drains / ducts / floors / fixed on poles / equipments complete all as specified and as directed.
(a) Lugs and glands shall be used appropriately wherever required while connecting cables to the panel board and the quoted rates are deemed be include for the same.
(b) Earthwork, sand cushioning, protection for cable etc., as required shall be measured and paid separately.
Taking up and down steel tubing and connections and taken on credit and provision of Steel tubing, galvanised, light grade, with all fittings such as bends, elbows, tees etc., and laid in bridges / culvert / trenches / under roads / crossings etc., of bore of pipe 80mm for cable protection complete all as specified and as directed.
Earthwork as required shall be measured and paid separately.
Taking up and down steel tubing and connections and taken on credit and provision of Steel tubing, galvanised, light grade, with all fittings such as bends, elbows, tees etc., and fixed complete to walls / poles etc., of bore of pipe 80mm with necessary climbing arrangement for cable protection complete all as specified and as directed.
Cable jointing kit for 11 kV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm as in repairs complete all as specified and as directed.
Cable jointing kit for 11 kV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm as in repairs complete all as specified and as directed.
Steel tubular swaged poles complete with mild steel base plate, finial taper plug, bolts, nuts and screws as specified, type 410, SP-55 (11.00 metres long) and shall be coated with two coats of black bituminous paint throughout internally, and externally up to the planting depth and the remaining, portion of the exterior shall be painted with one coat of red oxide zinc chrome primer as in repairs complete all as specified and as directed.
Earthwork, PCC foundation, coping etc as required for erection of pole shall be measured and paid separately.
Dismantling cross-arms of mild steel channel or angle sections etc., complete and taken on credit and provision of new Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat of red oxide zinc chrome primer, one under coat and one finishing coat of aluminium paint complete all as specified and as directed.
Disc type insulator, porcelain, vitreous 145mm high and 255mm dia ball and socket type, white, brown or green, "two in series" assembly for tension with cast aluminium, 4 U bolt tension hardware and tension clamps for conductors, working pressure 11000 volts as in repairs complete all as specified and as directed.
Dismantling old unserviceable ACSR conductor as in over head lines from poles and taken on credit and provision of new aluminium conductor steel reinforced (ACSR) conductors of assorted sizes stringed on poles and connecting complete all as specified and as directed.
The weight of ACSR conductor only shall be measured as per preamble given in Sl Page No.384 of SSR Part-II 2010.
Air break, gang operated switch, with current rating 200 Amps, HT, 11000 Volts, triple pole mechanically operated, mounted on insulator and steel frame, with operating mechanism worked from ground level as in repairs complete all as specified and as directed.
Supply, install, testing and commissioning of air break (switch) insulator, single pole for outdoor use for HT 11000 volts, 200 Amps with drop out fuse set, 200 Amps fuse link consisting of channel iron base having 02 Nos 12 kV post type insulators in stack, total 3 stack one for each phase with fuse carrier of SRBP tube with heavily tinned non ferrous metal parts and spring loaded phosphor bronze contact as per IS 9385 as in repairs complete all as specified and as directed.
Removing of old earthing materials and taken on credit and provision of new earthing complete with galvanised iron earth plate electrode 600mm X 600mm X minimum 6mm thick, with and including earthing of 25mm x 4mm GI strip protected by 40mm dia GI pipe light grade upto a length of 7.5m. The plate shall be buried directly in ground vertically to a depth not less than 2.25 metres below ground level with top edge of the earth plate at a depth not less than 1.5 metres below ground level, connected to earth lead as described here-in-before by means of bolts, nuts, washers and checknuts made out of galvanised iron or mild steel, earthing lead protected by as described here-in-before and connected to main switch board or main control board or electric pole all as shown on electrical plate No.3 of MES Sch Part-I including necessary earth work and excavation in any type of soil, plain cement concrete 1:3:6, type C1 chamber, reinforced cement concrete cover slab with locking arrangement and handle of 10mm dia MS round bars 450mm long, 1:2:4 type B1, 50mm thick with 8mm dia TMT bars at 140mm centre to centre both ways, GI pipe of bore 20mm medium grade for watering with funnel, wiremesh, salt, charcoal, lugs including testing complete all as specified and as directed.
EVEREST ENGINEERING WORKS
G.JANAKIRAMAN CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .