Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.3 LAccepted-AOC | ₹44.3 L Quoted ₹44.9 L | L1 | Accepted-AOC Admitted being L1 |
| 2 | L2₹45.2 LRejected-Finance 702 A1 SHREE PRASAD TAWADEWADI SHREE DATTAGURU PARK KUMBHARWADA URAN DIST RAIGAD MAHARASHTRA 400 702 | URAN | RAIGAD | MAHARASHTRA | 400702 | ₹45.2 L | L2 | Rejected-Finance Not admitted being L2 |
| 3 | L3₹47.6 LRejected-Finance FLAT NO 201 GREEN VALLEY CHS PLOT NO 26 SECTOR 19 NERUL EAST NAVI MUMBAI 400 706 | THANE | MAHARASHTRA | 400706 | ₹47.6 L | L3 | Rejected-Finance Not admitted being L3 |
| Rank | Bidder | Total Amount |
|---|---|---|
| L2 | Sagar Electricals Bid ID 3546021 | ₹45,16,933.74 |
| L3 | M.K Enterprises Bid ID 3548585 | ₹47,57,758.96 |
| L1 | M/s. Prakash Construction Bid ID 3539310 | ₹44,90,234.15 |
| Sl No | Description | Qty | Unit | Sagar Electricals L2 | M.K Enterprises L3 | M/s. Prakash Construction L1 |
|---|---|---|---|---|---|---|
| 1.00Notes : Please refer schedule 'A' notes before quoting the tender. BR WORKS :- | ||||||
| 1.01 | Chipping , removing carefullly concrete work by low impact hammer, breakar without damaging the structure & cleaning and disposal of debries outside the premises etc. complete all as specified and direced. NOTE:- Hard concrete should not be removed by force. | 410 | Sqm | 40 ₹16,400 | 60 ₹24,600 | 77 ₹31,570 |
| 1.02 | Clean existing reinforcement with wire/ rotary wire brush, making the surfaces free from loose material dirt etc. and M&L for applying two coats of alkaline rust converting primer (Make: FEOVERT of Krishna Conchem or Roff rust cleaner of Piddilite or Dr. Fixit Rust removal or ShaliRust of STP Ltd. or equivalent as approved by GE) on the rebars, including cleaning the reinforcement, wirebrushing to remove loose rust spalls, wash the rebars with clean water within 3 min and wipe it dry complete all as specified and direced | 50 | Sqm | 150 ₹7,500 | 170 ₹8,500 | 150 ₹7,500 |
| 1.03 | M&L for applying two coats of Epoxy based Zinc primer in a span of four hours over the treated rebars and allow to dry for six hours. The application shall be by brush complete all as specified and direced. (Make: Corroseal-ZR of Krishna Conchem or Dr. Fixit Epoxy zinc primer or equivalent as approved by GE) | 50 | Sqm | 150 ₹7,500 | 170 ₹8,500 | 240 ₹12,000 |
| 1.04 | Cleaning all loose laitance on the concrete substrate and M&L for applying one coat of epoxy bonding agent on exposed concrete surface to ensure bond between old concrete & new concrete by brush application complete all as specified and direced. (Make: Monobond SBR of Krishna Conchem or Dr. Fixit epoxy bonding agent or Shalicrete URP of STP Ltd or equivalent as approved by GE) | 410 | Sqm | 60 ₹24,600 | 55 ₹22,550 | 155 ₹63,550 |
| 1.05 | M&L for Building up the profile of structural members by using latex additives (MONOBOND) modified air cured mortar system (Polymer modified mortar) (1:5:15 = 1 monobond-5Cement-15 sand) -in damaged areas in 30mm thickness including leveling profliling etc complete all as specified and direced | 320 | Sqm | 240 ₹76,800 | 255 ₹81,600 | 545 ₹1,74,400 |
| 1.06 | M&L for providing and applying jacketing around columns with Micro concrete M40 including all lifts, shuttering, drilling holes and fixing shear anchor as per specification complete all as specified and direced. Note: (i) Reinforcement shall be measured and paid separately. (ii) Quoted rate is deemed to include for the cost of jacketing, formwork and micro concrete. | 8.5 | Cum | 57,000 ₹4,84,500 | 51,909 ₹4,41,226.5 | 49,950 ₹4,24,575 |
| 1.07 | M&L for Drilling and fixing Rohibb Teflon nozzles in RCC members, including drilling holes of 12mm dia, 50 to 100mm deep holes. Works shall be carried out as under complete all as specified and direced:-
(i) Cleaning of holes. Clean the holes by air blower prior to fixing nozzles.
(ii) Fixing of nozzles. Insert 12mm dia. Rohibb Teflon nozzles in cleaned holes. External end of nozzles to be machine to receive outlet of grouting gun.Fix it inside the holes by applying thixotropic epoxy putty to ensure complete sealing. Cure the system for min.12 hrs.
(iii) Cutting of nozzles. Cut the nozzles by chisel after completion of grouting without damaging structural elements.
(iv) In case crack upto 2mm wide, fix the injection nozzels directly over the cracks, at intervals of 6 to 9 inches, using a drilling machine. Fix PVC/MS nozzels in these holes with fast-setting epoxy putty & let it dry for 2 to 3 days. Also, seal the crack between the ports with epoxy putty.
(v) In case where the crack is wider than 2mm upto 4 to 5mm, drill holes at the sides of the crack in a staggered fashion, at intervals of 6 inches and affix them with epoxy putty as mentioned above.
(vi) Also, seal the face of the carck with a liberal application of the epoxy putty. | 150 | Each Job | 60 ₹9,000 | 75 ₹11,250 | 177 ₹26,550 |
| 1.08 | M&L for Injecting of site mixed cement slurry grout, mixed in specified proportion containing cement, sand water with addition of plasticizers (approved make) & migratory corrosion inhibitors, water cement ratio shall be varied between 0.5 to 1.0 for each hole, shrinkage compensating cement slurry mixed to a lump free fresh creamy consistency, Mixing shall be done by mechanical mixer continuously stirring mechanically to keep cement particles in suspension. Injection of approved/specified grout by means of pump at a pressure of 3-5 Kg/cm2 etc complete till the grout mix flows out from the nozzle indicating complete filling of grout in the holes drilled complete all as specified and direced. (Make: Dr. Fixit Epoxy injection or EPCO KP-HP-250 of M/s Krishna Conchem or Shaligrout EI of STP Ltd or equivalent as approved by GE) | 150 | Each | 75 ₹11,250 | 70 ₹10,500 | 135 ₹20,250 |
| 1.09 | M&L for Injecting low viscosity (3-5cps) high molecular weight monomer by pressure and using mechanized injector gun with accessories till nozzles refuses to accept the grout, including mixing of materials: Mixing of material components (part A & B) in the required quantities as per manufacturer's instruction by weight batching. Grouting:Fill the grouting gun with concrete penetrating corrosion inhibitor (Make: EPCO-KP-100/Protectsil CIT or Ferogard 903 or equivalent as approved by GE) Maintain desired pressure in the gun by air compressor; maintain the pressureat exit (2 to 3kg/cm2) by monitoring pressure guage at exit.Grout the material through prefixed nozzles in the structural elements @ 100ml per nozzle. Repeat the process for all the nozzles complete all as specified and direced | 15 | Kg | 240 ₹3,600 | 250 ₹3,750 | 350 ₹5,250 |
Updated dates
Tender Value
₹48.4 L
EMD Value
₹97,000
Closing Date
18 Feb 2026, 6:00 pmClosed
GE NW KARANJA
NAVAL STATION KARANJA, URAN, RAIGAD, MAHARASHTRA
SPECIAL REPAIRS TO BLDG NO P739 VEHICLE GARAGE FOR SPECIALIST VEHICLE BATTERY CHARGING ROOM POL RU STORE TYRE STORE ROOM AT INS TUNIR AT NAVAL STATION KARANJA
2026_MES_748988_1
8253/E8
Open Tender
Civil Works
180 days
GE NW KARANJA
D and above a i
8 documents required · 8 mandatory
₹500
Yes
GE NW KARANJA
₹97,000
Yes
18 Mar 2026
17 Jan 2026
21 Feb 2026
17 Jan 2026
18 Feb 2026
30 Jan 2026
Notes : Please refer schedule 'A' notes before quoting the tender. BR WORKS :-
Chipping , removing carefullly concrete work by low impact hammer, breakar without damaging the structure & cleaning and disposal of debries outside the premises etc. complete all as specified and direced. NOTE:- Hard concrete should not be removed by force.
Clean existing reinforcement with wire/ rotary wire brush, making the surfaces free from loose material dirt etc. and M&L for applying two coats of alkaline rust converting primer (Make: FEOVERT of Krishna Conchem or Roff rust cleaner of Piddilite or Dr. Fixit Rust removal or ShaliRust of STP Ltd. or equivalent as approved by GE) on the rebars, including cleaning the reinforcement, wirebrushing to remove loose rust spalls, wash the rebars with clean water within 3 min and wipe it dry complete all as specified and direced
M&L for applying two coats of Epoxy based Zinc primer in a span of four hours over the treated rebars and allow to dry for six hours. The application shall be by brush complete all as specified and direced. (Make: Corroseal-ZR of Krishna Conchem or Dr. Fixit Epoxy zinc primer or equivalent as approved by GE)
Cleaning all loose laitance on the concrete substrate and M&L for applying one coat of epoxy bonding agent on exposed concrete surface to ensure bond between old concrete & new concrete by brush application complete all as specified and direced. (Make: Monobond SBR of Krishna Conchem or Dr. Fixit epoxy bonding agent or Shalicrete URP of STP Ltd or equivalent as approved by GE)
M&L for Building up the profile of structural members by using latex additives (MONOBOND) modified air cured mortar system (Polymer modified mortar) (1:5:15 = 1 monobond-5Cement-15 sand) -in damaged areas in 30mm thickness including leveling profliling etc complete all as specified and direced
M&L for providing and applying jacketing around columns with Micro concrete M40 including all lifts, shuttering, drilling holes and fixing shear anchor as per specification complete all as specified and direced. Note: (i) Reinforcement shall be measured and paid separately. (ii) Quoted rate is deemed to include for the cost of jacketing, formwork and micro concrete.
M&L for Drilling and fixing Rohibb Teflon nozzles in RCC members, including drilling holes of 12mm dia, 50 to 100mm deep holes. Works shall be carried out as under complete all as specified and direced:- (i) Cleaning of holes. Clean the holes by air blower prior to fixing nozzles. (ii) Fixing of nozzles. Insert 12mm dia. Rohibb Teflon nozzles in cleaned holes. External end of nozzles to be machine to receive outlet of grouting gun.Fix it inside the holes by applying thixotropic epoxy putty to ensure complete sealing. Cure the system for min.12 hrs. (iii) Cutting of nozzles. Cut the nozzles by chisel after completion of grouting without damaging structural elements. (iv) In case crack upto 2mm wide, fix the injection nozzels directly over the cracks, at intervals of 6 to 9 inches, using a drilling machine. Fix PVC/MS nozzels in these holes with fast-setting epoxy putty & let it dry for 2 to 3 days. Also, seal the crack between the ports with epoxy putty. (v) In case where the crack is wider than 2mm upto 4 to 5mm, drill holes at the sides of the crack in a staggered fashion, at intervals of 6 inches and affix them with epoxy putty as mentioned above. (vi) Also, seal the face of the carck with a liberal application of the epoxy putty.
M&L for Injecting of site mixed cement slurry grout, mixed in specified proportion containing cement, sand water with addition of plasticizers (approved make) & migratory corrosion inhibitors, water cement ratio shall be varied between 0.5 to 1.0 for each hole, shrinkage compensating cement slurry mixed to a lump free fresh creamy consistency, Mixing shall be done by mechanical mixer continuously stirring mechanically to keep cement particles in suspension. Injection of approved/specified grout by means of pump at a pressure of 3-5 Kg/cm2 etc complete till the grout mix flows out from the nozzle indicating complete filling of grout in the holes drilled complete all as specified and direced. (Make: Dr. Fixit Epoxy injection or EPCO KP-HP-250 of M/s Krishna Conchem or Shaligrout EI of STP Ltd or equivalent as approved by GE)
M&L for Injecting low viscosity (3-5cps) high molecular weight monomer by pressure and using mechanized injector gun with accessories till nozzles refuses to accept the grout, including mixing of materials: Mixing of material components (part A & B) in the required quantities as per manufacturer's instruction by weight batching. Grouting:Fill the grouting gun with concrete penetrating corrosion inhibitor (Make: EPCO-KP-100/Protectsil CIT or Ferogard 903 or equivalent as approved by GE) Maintain desired pressure in the gun by air compressor; maintain the pressureat exit (2 to 3kg/cm2) by monitoring pressure guage at exit.Grout the material through prefixed nozzles in the structural elements @ 100ml per nozzle. Repeat the process for all the nozzles complete all as specified and direced
M&L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and direced. Note :- Replacement of steel reinforcement shall be done with TMT bars of appropriate size where 30% of cross section is reduced including dismantling of rusted steel.
M&L for TMT bars 5mm dia and over upto and including 10mm dia as additional main steel bar or stirrups of designed diameter in various structural elements like column, beams and foundations including drilling ,bending, welding and fixing the bars with epoxy putty etc. complete all as specified and direced. NOTE: Steel shall be provided on the basis of 1% of volume of concrete. (ii) Replacement of steel reinforcement with TMT bars of appropriate size where 30% of cross section is reduced including dismantling of rusted steel is deemed to be included in quoted rates.
Complete Removal of existing water proofing treatment any description up to concrete surface of roof slab including cleaning, with wire brushing, watering, removal of debris to a distance of 1.5 km or under, complete all as specified and directed. Note :- Unit rate quoted shall also include for removal of PVC water storage tank wherever existing carefully and refixing at the same or other position after completion of roof repair work.
M&L for cleaning the new surfaces concrete with wire brushing and applying Water Proofing Treatment as under complete all as specified and direced:- (i) Apply oil bound bitumen primer conforming to IS-3384:1986 @ 0.40 Litre/Sqm manufactured by the same agency as that of APP with density of 0.87 to 0.89 Kg/Litre at 25 degree Celsius on the pepared dry roof surface. (ii) Laying APP polymer modified membrane 4mm thick using torch-on application with non-wooven ployster mat as reinforcement weighing not less than 4.50 Kg/Sqm mineral finished by thermo fusion process, duly sealed at over laps & joints with end laps of 10cm and side over laps of 7.5cm all as per manufacturer’s instructions. (iii) Over the membrane, provide a finishing with two coats of Solar reflective bituminious aluminium paint @ 0.10 Kg/Sqm as prescribed by manufacturer.
M&L for Brushing neat cement slurry with 3kg/sqm, complete all as specified and direced
M&L for rendering 10mm thick cement plaster in CM (1:3) on roof top surface including WPC by weight of 3% of total cement content finished even and smooth without using extra cement complete all as specified and as directed. Note : WPC shall be measured & paid separately.
Demolition of cement concrete (unreinforced) roof or chajja padding of any description and any position not otherwise specifically provided for complete all as specified and directed.
M&L for PCC (1:2:4) type B-1, using 20 mm graded stone aggregates as in padding to roof to maintain the required slope including WPC by weight of total cement as per manufacturer's specifications as in chajjas, balconies, canopies, desk slabs and in shelves and finished the surface even and smooth without using extra cement, complete all as specified and directed. Note : WPC shall be measured & paid separately.
Supply only water proofing liquid compound complete all as specified and direced.
S&F Aluminium door/window/ventilator/partition, made out of extruded powder coated aluminium sections, with sliding or open-able shutters including frame & necessary jointing cleats, glazing clips, powder coated aluminium snap beading, screws etc, complete and also including powder coated aluminium fittings such as stainless steel hinges, tower bolts, hooks & eyes, peg stays and handles, concealed star lock for aluminium window, Mortice lock vertical type size 100mm 04 lever for door, rubber beading suitable for fixing 4mm / 5mm thick glass in aluminium window / doors including connected items, with and making good to the disturbed portion with its original specifications including taking down existing members/frame any position complete all as specified and directed.
S&F 4 mm thick sheet glass ordinary quality and glazing in square not exc 0.50 sqm each, complete all as specified and direced.
S&F Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples, complete all as specified and direced.
S&F powder coated aluminium grill of design DG 104 pattern made out of 10mm dia rod fixed with and including standard aluminium frame of F section of size 23.40mmx15.30mm & 1.4mm thick all as per manufactures instructions complete all as specified & directed.
Dismantling of steel rolling shutter in any position in exc 10 sqm and nexc 30 Sqm including all fittings complete all as secified and as directed.
S&F rolling shutter with gear operated type with bevel gear box and crank handle, thickness of laths 1.00mm including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete all as secified and as directed.
Demolition of pre-cast concrete block masonary built in cement mortar including all quoins, arches, pillars etc. and pre cast concrete articles complete all as specified and directed.
M&L for pre-cast cement concrete block masonry with solid blocks in 10cm in width in type B1 1:2:4 (20mm graded aggrgate) and setting in mortar (1:6) complete all as specified and as directed
Taking down cement plaster on brick walls or stone walls etc including raking out joint, hacking for key, scrubbing down with water etc including removing debries directed for a distance max upto 500m complete all as specified and direced.
M&L for rendering 15mm thick on fair faces of brick/concrete surfaces in CM (1:4), finished even and smooth without using extra cement (WPC to be measured and paid separately) complete all as specfified and directed.
M&L for rendering 10 mm thick on fair faces of brick work or concrete surfaces of walls in cement mortar 1:6 finished even and smooth (with out using extra cement) complete all as specified and direced.
M&L for rendering 5 mm thick on ceilings in CM 1:3 and finishing the surface even and smooth without using extra cement complete all as specified and direced.
M&L for three coats of white wash on newly plastered surfaces of ceilings including preparation of surface complete all as specified and direced.
Preparation of new or previously untreated plastered surfaces of walls and M&L for applying two coats of acrylic antifungal paint exterior grade paint plain or camouflage pattern over & including one coat of primer complete all as specified and as directed
Preparation of new plastered surfaces on walls of any description not otherwise described over 10cm width or girth and M&L for applying two coats of oil bound distemper over & including a coat of alkali resistant primer, complete all as specified and as directed.
Complete removal of existing treatment on external wall surface by sanding machine or any other mechanical means thereafter washing, rubbing down the surface, in order to remove dust, dirt, loose particles etc. and fill the visible cracks/joints with crack seal caulking compound after cleaning the surface by clean water and M&L for Applying a coat of primer (water based primer) and allow to dry for six hours. Thereafter, M&L for applying two coats of water proofing treatment on wall (WB high build anti carbonation cum water proofing including a coat of exterior grade weather proof acrylic emulsion paint by using Airless Paint Sprayer machine at any height of the building by using scaffolding complete all as specified and direced. (Make: Pidilite, Beregr, Asian Paints and Chemistic or equivalent as approved by GE. The material used for the teratment must have crack binding ability, water proofing properties and flexible (i.e cover hairline cracks upto 2mm effectively) and be elastomeric. Note : The quoted rates is demed to include for External water proofing treatment on wall at any height of the building including acrylic paint applied by mechnaically Airless paint sprayer machine only.
Complete removal of existing treatment from old decorated plastered surfaces of walls & ceilings by Vacuum based sanding machine, removal of nails etc & filling cracks/hole with putty, M&L for applying wall care putty upto 2 mm thick (multipurpose mixer shall be used for uniform and proper mixing of putty) and M&L for applying two coats of oil emulsion distemper white or coloured over & including a coat of approved primer by auto roller complete all as specified & directed.
Demolition of cement concrete (unreinforced) in ground floors and paving not exceeding 15 cm thickness (below or above ground level) complete all as specified and directed.
M&L for plain cement concrete 1:3:6 type C-1 (using 20 mm graded stone aggregate) as in plinth protection, 75 mm thick, finished even and smooth without using extra cement, including making joints 12 mm wide to the full depth of PCC at every 3 metres and at every change of direction and filling the same with & including bitumen and sand 1:3 by weight complete all as specified and directed.
M&L for cement concrete type B-2 1:2:4 using 40 mm graded stone aggregate as in path/floor, finished fair even and smooth without using extra cement, laid in alternate panels of size not exc 4 sqm each complete all as specified and direced.
M&L for 25mm thick Wear proof topping (using approved metallic floor hardener as per manfacutre's instruction) with PCC 1:2:4 type B-0 (using12.5 mm graded stone aggregates) as specified, laid on concrete floors and pavings and path, and finished even and smooth (except metallic hardner) complete all as specified and direced. Note: Metallic hardender & glass strips shall be measured and paid separately.
Supply only 22 mm wide and 3 mm thick glass dividing strips as laid in floor complete all as specified and direced.
Supply only metallic hardner mix with cement cncrete as per manufacture instruction complete all as specified and direced. (Make: DR. FIXIT PIDE PROOF LW, FOSROC or equivalent as approved by GE)
Dismantling of stone slabs & tiles of any description or thickness in floor aprons, cills etc laid bedded & pointed in any mortar complete all as specified and directed.
M&L for Green marble slab18-20 mm thick as in (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platform and like in CM 1:4 including pointing in white cement 1:2 using marble dust with admixture of pigment to match with & including 20 mm thick screed/backing coat in CM 1:3 complete all as specified and as directed.
Dismantling of floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises and removal to a distance not exceeding 100m complete all as specified and direced.
M&L for acid resistant tiles 15 mm thick vitreous ceramic, unglazed, set, jointed and pointed in chemical resistant mortar, resin type, in floors over & incuding 15mm thick screed bed in CM 1:4 complete all as specified and direced
M&L for acid resistant tiles 15 mm thick vitreous ceramic, unglazed, set, jointed and pointed in chemical resistant mortar, resin type, in vertical surfaces / wall over & incuding 15mm thick screed bed in CM 1:3 complete all as specified and direced.
INTERNAL EM WORKS :-
M&L for submain wiring with two core 1100 volts 2.5 sqmm FRLSH size PVC insulated PVC unsheathed stranded copper conductor using color code drawn through on walls with & incuding ERW Steel Stove conduit 19/20 mm dia with accessories like bend, junction box etc and including 2.5 sqmm PVC insulated PVC unsheathed FRLSH copper conductor in cable for continuous earth continuty conductor by using green colour to common earth and connecting to earth point and connecting to earth dolly including taking down existing wiring for upto five light point/fan point/exhasut fan controlled by one16 Amps complete all as specified and direced. Note:- Two run of 2.5 Sqmm, one run of 2.5 Sqmm earth wire and one run of ERW steel conduit shall be measured as one running metre.
M&L for submain wiring with two core 1100 volts 1.5 sqmm FRLSH size PVC insulated PVC unsheathed stranded copper conductor using color code drawn through on walls with & incuding ERW Steel Stove conduit 19/20 mm dia with accessories like bend, junction box etc and including 2.5 sqmm PVC insulated PVC unsheathed FRLSH copper conductor in cable for continuous earth continuty conductor by using green colour to common earth and connecting to earth point and connecting to earth dolly including taking down existing wiring for one light point/fan point/exhasut fan/ 5 amp Iindependent board controlled by one 5 Amps complete all as specified and direced. Note:- Two run of 1.5 Sqmm, one run of 1.5 Sqmm earth wire and one run of ERW steel conduit shall be measured as one running metre.
M&L for submain wiring with two core 1100 volts 4.0 sqmm FRLSH size PVC insulated PVC unsheathed stranded copper conductor using color code drawn through on wall with & incuding ERW Steel Stove conduit 19/20 mm dia with accessories like bend, junction box etc complete all as specified in and including 4.0 sqmm PVC insulated PVC unsheathed FRLSH copper conductor in cable for continuous earth continuty conductor by using green colour to common earth and connecting to earth point and connecting to earth dolly including taking down for one15 AMP controlled controlled by one 15 Amps complete all as specified and direced. Note:- Two run of 4.0 Sqmm, one run of 4.0 Sqmm earth wire and one run of ERW steel conduit shall be measured as one running metre.
M&L for Submain wiring with two core 1100 volts 6.0 sqmm FRLSH size PVC insulated PVC unsheathed stranded copper conductor using color code drawn through ON WALL with & incuding ERW Steel Stove conduit 19/20 mm dia with accessories like bend, junction box etc complete all as specified in and including 6.0 sqmm PVC insulated PVC unsheathed FRLSH copper conductor in cable for continuous earth continuty conductor by using green colour to common earth and connecting to earth point and connecting to earth dolly including taking down for one 25 AMP CONTROLLED controlled by one 25 Amps complete all as specified and direced. Note:- Two run of 6.0 Sqmm, one run of 6.0 Sqmm earth wire and one run of ERW steel conduit shall be measured as one running metre.
M&L for Submain wiring with two core 1100 volts 10.0 sqmm FRLSH size PVC insulated PVC unsheathed stranded copper conductor using color code drawn through ON WALL with & incuding ERW Steel Stove conduit 19/20 mm dia with accessories like bend, junction box etc complete all as specified in and including 10.0 sqmm PVC insulated PVC unsheathed FRLSH copper conductor in cable for continuous earth continuty conductor by using green colour to common earth and connecting to earth point and connecting to earth dolly including taking down for ONE 32 AMP CONTROLLED controlled by one 32 Amps complete all as specified and direced. Note:- Two run of 10. Sqmm, one run of 10.0 Sqmm earth wire and one run of ERW steel conduit shall be measured as one running metre.
S&F LED building security light fitting with suitable size bracket/angle to fit security light of 60w IP 66 protection LED including taking down complete all as specified and direced.
Refixing of security light LED building security light fitting with suitable size bracket/angle to fit security light of any size complete all as specified and direced
S&F switch flame proof rotary type with termination box in LM6, 16 amp single pole 250V complete including taking down complete all as specified and direced
S&F switch socket plug combination in LM6 combination cable termination box LM6 , 16 Amp 250 v, 2p+earth flame proof rotary type with termination box in LM6, 16 amp single pole 250V complete including taking down complete all as specified and direced
S&F switch socket plug combination in LM6 combination cable termination box LM6 , 25 Amp 250 v, 3p+earth flame proof rotary type with termination box in LM6, 16 amp single pole 250V complete including taking down complete all as specified and direced
S&F switch socket plug combination in LM6 combination cable termination box LM6 , 32 Amp 250 v, 3p+earth flame proof rotary type with termination box in LM6, 16 amp single pole 250V complete including taking down complete all as specified and direced
S&F in repair flame proof LED well glass hanging type 100w fitting on light point with suitable hanging arrangements one light control with one MCB SP, looping wire of suitable size complete all as specified and directed.
S&F FLP FLEXIBLE metalic hose conduit 1000 mm long for 19/20 mm dia fixed on directed place complete include taking down complete all as specified and direced
S&F FLP FLEXIBLE metalic FLEXIBLE conduit 20 mm long for 19/20 mm dia fixed on directed place complete include taking down complete all as specified and direced
S&F FLP FLEXIBLE MS steel of thickness 3mm for making frame for mounting switch /socket ets fixed on wall directed place including including taking down complete all as specified and direced
Fixing only and concealing Flame proof switch socket combination single phase or three phase on on the wall complete all as specified and direced. Note : Flame proof switch socket combination single phase or three phase will be reused. Making hole or chasing the wall and make good the disturbed surface will be consided in the quoted rate.
S&F copper strip 32 mm x 6 mm buried in ground/Saddle on wall as per site requirement for earth continuity conductor or fixed to porcelain, insulator fixed to wall as in repairs, complete include taking down all as specified and directed.
M&L for earthing complete with copper earth plate electrode of size 60 cm x 60 cm x 6 mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below the normal ground level connected with copper strip 32 x 6 mm by means of bolts, nuts, check nuts & washers of galvanished iron steel including necessary excavation and earth work in any type of soil, removing surplus soil to a distance not exc 50 m, with and including PCC chamber in PCC (1:2:4), type B1, using (20 mm graded stone aggregate), mild steel angle iron frame made out of MS angle iron of size 40 x 40 x 6 mm thick duly painted with two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer hinged with and including 6mm thick CI cover with handle, watering arrangement with funnel internally secured with wire mesh with 20 mm dia medium grade pipe for watering ,40 mm dia light grade GI pipe for lead protection in & including alternate layers of charcoal dust and common salt complete all as shown in electrical plate No 3 of SSR Part-1 (2009) connected to earthing test point including testing on completion complete all as specified and direced. {Qty- Intenal EM -2, Lightening protection -2}
S&F replacement MCB SP 240 V, 50 Hz, 10 KA conforming to IS 8828 of rating 5 to 32 Amp, 'C' series complete all as specified and direced.
S&F in repairs SPN 32 AMP MCB DP 240 V 10 KA (C-Series) complete all as specified and directed.
S&F in repairs MCCB 4 pole, thermal magnetic release range 100 Amps of breaking capacity 16 kA, 415 Volts, 50 Hz, complete all as specified and direced
S&F ceiling rose, 3 phase/PVC/polycarbonate, isolated body, three terminals complete all as specified and directed.
S&F surface and wall mounted LED batten of 20/22 W with polycarbonate housing & integrated electronic driver having THD<20% including taking down complete all as specified and direced.
S&F double door MCB DB made out of 18SWG CRCA steel sheets, Phosphates powder coated with copper bus bar, Earth stud, Din Rail, Polyamide Terminal Blocks for incoming and outgoing circuits, inbuilt loose wire box, Ground terminal blocks, duly pre-wired with thimble flame retardant copper conductors and poly layer for protection SP 240 volts 100 Amps rated bus bar 12 way double door open able, including taking out old unsv MCB DB any size/type complete all as specified and direced.
S&F three phase, vertical type, flame proof, 4 way, MCB DB ex d II A/IIb EMR class 1 CMRI approved made out of 18SWG CRCA steel sheets, Phosphates powder coated with copper bus bar, Earth stud, Din Rail, Polyamide Terminal Blocks for incoming and outgoing circuits, inbuilt loose wire box, Ground terminal blocks, duly pre-wired with thimble flame retardant copper conductors and poly layer for protection SP 240 volts 200 Amps rated bus bar, 4 way, double door open able, including necessary MCB and sp for connection and taking out old unsv MCB DB any size/type complete all as specified and direced
S&F double door, MCB, VTPN, DB, 4 way made out of 18SWG CRCA steel sheets, Phosphates powder coated with copper bus bar, Earth stud, Din Rail, Polyamide Terminal Blocks for incoming and outgoing circuits, inbuilt loose wire box, Ground terminal blocks, duly pre-wired with thimble flame retardant copper conductors and poly layer for protection SP 240 volts 100 Amps rated bus bar 4 way, including taking out old unsv MCB DB any size/type complete all as specified and direced.
Supplying, jointing, connecting & testing in trenches XLPE/PVC 10 sqmm, 2 core insulated PVC sheathed cable heavy duty 1100 volts grade, aluminum conductor in trenches / ducts including taking out cable cover & cable complete all as specified and direced
S&F switch piano flush button single pole one way, 6 Amp (ISI marked) complete all as specified and direced.
S&F Switch socket combination outlet 15 Amp, 5-in-1, controlled by one switch (ISI marked) complete all as specified and direced.
M&L for Sub main wiring with two runs of single core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor FRLSH cable of 1.5 Sqmm (with colour code), drawn in but including non metallic rigid PVC conduit of 20mm dia/casing capping/ suitable size, ISI marked including one run of PVC insulated unsheathed, multistranded copper conductor FRLSH cable of 1.5 Sqmm (Green colour) as contineous earth conductor cable connected to earth dolly in surfaces/ recess complete including taking down complete all as specified and direced. Note:- Two run of 1.5 Sqmm, one run of 1.5 Sqmm earth wire and one run of PVC conduit shall be measured as one running metre.
M&L for Sub main wiring with two runs of single core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor FRLSH cable of 2.5 Sqmm (with colour code), drawn in but including non metallic rigid PVC conduit of 20mm dia/casing capping/ suitable size, ISI marked including one run of PVC insulated unsheathed, multistranded copper conductor FRLSH cable of 2.5 Sqmm (Green colour) as contineous earth conductor cable connected to earth dolly in surfaces/ recess complete including taking down complete all as specified and direced. Note:- Two run of 2.5 Sqmm, one run of 2.5 Sqmm earth wire and one run of PVC conduit shall be measured as one running metre.
M&L for cutting of wall/ceiling/column for laying submain of any size including making good exixting surfaces complete all as specified and direced.
S&F MS sheet thickness 2 to 3mm for covering db etc including welding, machining, painting, etc work including minor items and taking down complete all as specified and direced.
M&L for submain wiring with 4 runs of single core 10 sqmm PVC insultaed, unsheathed multi stranded copper concuctor cable, 1100 Volts conforming to IS-694 1990 with ISI mark, drawn through and including PVC conduit 25 mm bore/ PVC casing capping 25 mm size including one run of 10 Sqmm PVC insulted multistanded copper conductor cable, 1100 Volts grade conforming to IS -694, 1990 green colour for earth contuinity and connecting up to common earth dolly complete including taking down complete all as specified and direced. Note:- Four run of 10 Sqmm, one run of 10 Sqmm earth wire and one run of PVC conduit shall be measured as one running metre.
LIGHTENING PROTECTION WORKS :-
Taking down old aluminium strip and air termination rod 12mm dia and 300 mm long with all fixing arrengements complete all as specified and direced.
S&F air termination single pointed aluminium rod 12 mm dia and 300mm long with necessary fixing arrangement on aluminuim plate of suitable size on roof, complete all as specified and direced.
S&F test point terminal block made of gun metal or phosphorus bronze size 75 x 75 x 25 mm thick drilled and screwed including 3 Nos 8 mm dia 25 mm long hexagonal head screws fixed to GI / aluminium strip bracket fixed to porcelain insulator in wall complete all as specified and direced.
Refixing of aluminium strip of size 25 x 3.15 mm fixed with suitable saddles & fixing screw etc on roof with rubber & bitumen washer & fixed to insulator on wall for down conductor as fixed in repairs, the rates includes making arrangement for insulators and insulators complete all as specified and directed.
S&F aluminium strip of size 25 x 3.15 mm fixed with suitable saddles & fixing screw etc on roof with rubber & bitumen washer & fixed to insulator on wall for down conductor as fixed in repairs, the rates includes making arrangement for insulators and insulators complete all as specified and directed
S&F aluminium strip of size 32x6mm mm fixed with suitable saddles & fixing screw etc on roof with rubber & bitumen washer & fixed to insulator on wall for down conductor as fixed in repairs, complete all as specified and directed
M&L for PCC (1:2: 4) type BO, using (12.5 mm graded stone aggregate) of blocks size and IE rules including necessary use and waste of form work as in grounting of porcelain insulator, complete all as specified and direced.
M&L for PCC (1:2:4) type B1, using (20 mm graded stone aggretgate) for earth chambers as in repairs, coping for GI pipe post including necessary form work, excavation in soft loose soil, returning in filling and removing surplus soil to a distance n. exc 50 mtr and deposing where directed complete all as specified and direced
S&F 50 mm dia GI pipe medium grade for post not exceeding 3 mtrs in length truly vertical position embbed in PCC including n.exc and earth work as in repairs, complete all as specified and directed. Note : PCC of of pole embeded will be measured and paid separately under relevant items of Sch.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.38 MB
Tenderpages8253.pdf
Tender Documents • 3.24 MB
BOQ_838785.xls
BOQ • 2.54 MB
Download all tender documents and submit your bid