SE EDC-I BSR
SE EDC-I HYDEL COLONY BULANDSHAHR
Under the Business Plan 2023-24 scheme, capacity enhancement of overloaded transformers, installation of poles in long spans, replacement of dilapidated wires, guarding and other related works.
2023_PVVNL_799444_1
T-07/EDC-I/B/2023-24
Open Tender
Electrical Works
Item Rate
30 days
BULANDSHAHR
PLZ REFER TENDER DOCUMENT
2 documents required · 2 mandatory
₹3,540
SE EDC-I
₹16,000
10 May 2023
29 Apr 2023
4 May 2023
29 Apr 2023
4 May 2023
29 Apr 2023
Amount
fo|qr forj.k [k.M&[kqtkZ] ds fctusl Iyku 2023&24 ¼vfrfjDr½ ;kstuk ds vUrXkZr vfrHkkfjr ifjorZdks dh {kerko`f)] yEcs LiSuks esa iksy yxkuk] ttZj rkj cnyuk] xkfMZx o vU; laca/kh dk;ZA
Carriage of fallowings from ESC. BSR to pit site on kachcha pacaa road including loading and unloading chagres at both ends, rcquricd for proper completion of work, distance about to 40 Kms.
S T Pole 13 Mtr. Long.
S T Pole 11 Mtr. Long.
PCC Pole 8.5 mtr Long.
Cartage of following Transformer from Store centre to JE Store/ Sub Stations including loading and unloading.
ACSR Weasel conductor, ABC conductor GI Wire, Earth Wire. M.S. Chanel, Angle, Stay & Earthig Rods, Barbed Wire. Disc Insulator etc.
10 KVA Transformer.
25 KVA Transformer.
63 KVA Transformer.
100 KVA Transformer.
Carriage/Cartage of following All line Material/TF.From JE store Sub Station To Pit Site.(approximate distance 20 km.) including loading and unloading.
ACSR Weasel conductor, ABC conductor GI Wire, Earth Wire. M.S. Chanel, Angle, Stay & Earthig Rods, Barbed Wire. Disc Insulator etc.
10 KVA Transformer.
25 KVA Transformer.
63 KVA Transformer.
100 KVA Transformer.
Erection of Single pole support including complete 1 IT fittings as per RESPO manual and as per direction of Engineer in charge including the cost of labour, T&P and carrier etc. required for proper completion of work.
Erection of Double pole/Scation Pole support including complete 1 IT fittings as per RESPO manual and as per direction of Engineer in charge including the cost of labour, T&P and carrier etc. required for proper completion of work.
Grouting of Single support shall be grouted with cement, sand and birck ballast/stone ballast in ratio 1:4:8 =30x3030 cms. including the cost of cement, sand, birck ballast/stone ballast, etc. as per actual size requirement, as per RESPO manual and as per direction of Engineer in charge including the cost of labour, T&P and carrier etc. required for proper completion of work.
Grouting of Double pole support shall be grouted with cement, sand and birck ballast/stone ballast in ratio 1:4:8 =30x3030 cms. including the cost of cement, sand, birck ballast/stone ballast, etc. as per actual size requirement, as per RESPO manual and as per direction of Engineer in charge including the cost of labour, T&P and carrier etc. required for proper completion of work.
Cutting /drilling /Welding of MS Angle iron for making guarding angle size 65x65x6/50x50x6 mm including the work of fixing the bracket on PCC/ST pole for construction of the line.
Fixing of 11 Kv Stay rod with Stay wire in proper way with Nozelling
Grouting of 11 Kv Stay rods
Giarding Of 11 KV Line/Spen
Laying, sagging. Stringing and binding and jumpering of 11 Kv XLPE cable 3*70/120/185 Square MM & Outher size newly erected pole as per RESPO manual and as per direction of supervising engineer. It includes the cost of labour, T&P, carrier etc. requried for proper completion of work.
Laying, sagging. Stringing and binding and jumpering of ACSR Weisal , rabbit, dog newly erected pole as per RESPO manual and as per direction of supervising engineer. It includes the cost of labour, T&P, carrier etc. requried for proper completion of work.
ACSR Weasel conductor
ACSR Dog conductor
ABC 3x50 SqMm
ABC 3x95 SqMm
ABC 3x120 SqMm
The folloing material is Fixing/Installations.
Fixing of 11 KV X arm
Fixing of Earthing rod
Fixing of pin insulator
Fixing disc insulator
Fixing of Toff Channel
Fixing of Barbed Wire
Fixing of Cross branching
Fixing of Sub station Set for T/F
Side Bracket
Safe placing of newly Transformer on Single/D/p/Plinth
10 KVA Transformer.
25 KVA Transformer.
63 KVA Transformer.
100 KVA Transformer.
Complete jumpering of 11 KV on double pole
The folloing material is required to be supplied by the contractor.
Holding clamp.
Double Pole clamp
F Clamp
PG Clamp
Side Bracket
LT Clamp
J hook
Earth clamp
Stay clamp
Dead & clamps
Peircing Clamps
Barbed Wire
I bolt for guarding
Jointing Kit.
3Ph Distribution Box.
Stay insulator for 11 Kv
Suspension clamps
LT Insulator
Nut & Bols.
M/S SHRI KRISHNA CONTRACTORAS
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .