Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.1 LAccepted-AOC PLOT NO 17 GF PRATAP NAGAR NEW DELHI 110064 | WEST | DELHI | 110064 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹28.8 L+₹3.3 L (13.1%)Rejected-Finance G 124 FLAT NO 4 DILSHAD COLONY DELHI 110095 | SHAHDARA | DELHI | 110095 | L2 | Rejected-Finance Being other than lowest | |
| 3 | L3₹29.2 L+₹3.7 L (14.6%)Rejected-Finance N A | NA | NA | 121004 | L3 | Rejected-Finance Being other than lowest | |
| 4 | L4₹31.0 L+₹5.5 L (21.5%)Rejected-Finance C 204 NANGLI EXTN NEW DELHI | WEST | DELHI | 110043 | L4 | Rejected-Finance Being other than lowest | |
| 5 | L5₹31.6 L+₹6.1 L (24.0%)Rejected-Finance | L5 | Rejected-Finance Being other than lowest |
Tender Value
₹49.9 L
EMD Value
₹99,800
Closing Date
10 Nov 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (East) Delhi Cantt-10
GE (East) Delhi Cantt-10
REPAIR TO ROOF TRTMT INCL REPAIR TO OH WATER STGE TANKS AT KABUL LINES, FAFA, OTM ACCN OF CERTAIN UNITS AND REPAIR CUM CLEANING OF SEWAGE LINES AND DRAINS AR KABUL LINES AND OTM ACCN OF CERTAIN UNITS IN AGE BR-II UNDER GE (EAST) DEL CANTT-10
2021_MES_482273_1
GE/DE-61/2021-22
Open Tender
Civil Works
Item Rate
330 days
GE (East) Delhi Cantt-10
Class D Cat a i
8 documents required · 8 mandatory
₹500
GE (East) Delhi Cantt-10
₹99,800
Yes
29 Nov 2021
16 Oct 2021
17 Nov 2021
16 Oct 2021
10 Nov 2021
27 Oct 2021
16 Oct 2021 - 21 Oct 2021
60 days
Amount
Demolition of cement concrete (reinforced) of any description and in any position complete all as specified and as directed.
Demolition of cement concrete (unreinforced) of any description and in any position complete all as specified and as directed.
Demolition of brick work built in cement mortar including all quoins, arches, pillars etc., but excluding ashlar facings, complete all as specified and as directed.
Dismantling floor, hearth or wall ceramic tiling including cement mortar bedding (but not backing) and rubbish off the premises, complete all as specified and as directed.
Dismantling/taking out existing roof treatment with brick tiles/APP membrane of any thickness including taking out of screed bed of any thickness and removing rubbish off the premises, complete all as specified and as directed.
Demolition of mud/cement concrete in roofs including plastering and leeping, including removing slavaged materials off the MOD land to a distance exc 250mtr but not exceeding 500mtr, complete all as specified and as directed.
Dismentling of RCC jalli of any description and in position and unserviceable jalli removed from site and serviceable jalli stacking at site after cleaning/dusting complete all as specified and as directed.
Dismantling wrought iron or mild steel work of any description not other wise provided for, complete all as specified and as directed.
Taking down steel tubing and connections including cleaning for refixing or removal from site for bore of pipe 15mm, complete all as specified and as directed.
Taking down steel tubing and connections including cleaning for refixing or removal from site for bore of pipe 20mm, complete all as specified and as directed.
Taking down steel tubing and connections including cleaning for refixing or removal from site for bore of pipe 25mm, complete all as specified and as directed.
Dismantling existing water tanks of capacity exc 250 & not exceeding 500 ltrs lowering from its position and removal to store, complete all as specified and as directed.
Demolition and breaking up drain pipes (salt-glazed stone ware, AC or reinforced concrete) set in cement mortar 100mm dia, complete all as specified and as directed.
Demolition and breaking up drain pipes (salt-glazed stone ware, AC or reinforced concrete) set in cement mortar 150mm dia, complete all as specified and as directed.
Demolition and breaking up drain pipes (salt-glazed stone ware, AC or reinforced concrete) set in cement mortar 200mm dia, complete all as specified and as directed.
Taking down rain water pipes (any size and pattern) including all fittings, head shoes, bends, swan necks, etc., and removal off the site, complete all as specified and as directed.
Dismantling of cast iron or reinforced concrete drain pipes 75mm to 100mm dia, jointed in cement mortar and taking out of trenches, wall and in shafts or other similar work, complete all as specified and as directed.
Excavation in trenches not exceeding 1.5mtr wide and not exceeding 1.5mtr deep and getting out complete in any type of soil, complete all as specified and as directed.
Excavation in trenches exceeding 1.5mtr but not exceeding 3.0mtr wide and not exceeding 1.5mtr deep and getting out complete in any type of soil, complete all as specified and as directed.
Returning, filling in, including spreading, leveling watering and well raming in layers not exceeding 25cms thick complete all as specified and as directed.
Removal of surplus soil to a distance exceeding 250mtrs but not exceeding 500mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point, complete all as specified and as directed.
Plain cement concrete 1:4:8, Type D-2 using 40mm graded crushed stone aggregate as in foundations, filling and mass concrete, complete all as specified and as directed.
PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregate as in benching, coping, hold fast blocks etc., and similar items including weathering, slightly rounded or chamfered angles and throating on top of chajjas, rails, cills etc., complete all as specified and as directed.
Plain cement concrete 1:2:4 type B-1 using 20mm graded crushed stone aggregate, as in roof kerb/benching, mud stops, OHT palteform and similar items including weathering, slightly rounded or chamfered angles and throating on top of chajjas, rails, cills etc., including necessary form work required if any, complete all as specified and as directed.
PCC 1:2:4 type B-0 using 12.50 mm graded crushed stone aggregate as in PCC padding over roof, complete all as specified and as directed.
Reinforced cement concrete 1:1.5:3 type A-1 using 20mm graded crushed stone aggregate, as in roof/floor slabs supported on walls, beams and shelves etc., complete all as specified and directed.
Providing precast reinforced cement concrete 1:2:4 type B1 using 20mm graded crushed stone aggregate in louvers and jallies, 35 mm thick (measured solid), including all mouldings but excluding frame (precast frame shall be measured separately) set in cement mortar 1:4, complete all as specified and as directed.
Precast cement concrete 1:2:4 type B-1 using 20mm graded crushed stone aggregate, as in drain covers (perforated type) and the like, set in cement mortar 1:4, complete all as specified and as directed.
1:2:4 type B-2 using 40mm graded crushed stone aggregate as in surface channels and drains. complete all as specified and directed.
Extra for forming fair finished drain or channel 30 cm inner grith in cement concrete using extra cement including forms, moulds, mitred/stopped ends etc., complete all as specified and directed.
Brick work with sub class “B” bricks straight or curved on plan exceeding 6mtr mean radius built in cement mortar 1:4 using old size bricks, complete all as specified and as directed.
Brick work with sub class “B” bricks straight or curved on plan exceeding 6mtr mean radius built in cement mortar 1:6 using old size bricks, complete all as specified and as directed.
All as per description of Srl Item No. 32 here-in-before but except bricks, complete all as specified and as directed.
Brick work with sub class “B” bricks straight or curved on plan to any radius built in cement mortar 1:4 using old size bricks, complete all as specified and as directed.
Use and waste of form work to soffits of suspended slabs such as roof slabs, shelves etc., not exceeding 200mm thickness for fair finished concrete surfaces, complete all as specified and as directed.
Mild steel TMT bars upto 10mm dia and over, cut to length, bent to shape required, including cranking, bending, spirally for hopping for columns, hooking ends, and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming to Fe-410-S or Fe-410-0, complete all as specified and as directed.
Mild steel TMT bars upto 6 to 8mm dia, cut to length, bent to shape required, including cranking, bending, spirally for hopping for columns, hooking ends, and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming to Fe-410-S or Fe-410-0, complete all as specified and as directed.
Mild steel framed work as in grills, gratings etc., with ends of bars shouldered and or riveted or forged into spikes, framed guard bars, barred iron doors, ladder, framed balusters, railing, frame work for water tanks and similar work, complete conforming to Fe 290 Gde-E-165 including shop coat of red oxide including preparation of surface before fixing, complete all as specified and as directed.
Cleaning surface of roof with wire brushes thoroughly to remove loose dust/dirt particles to expose clean concrete surface and washing with water, complete all as specified and as directed.
15mm thick screed bed in cement mortar 1:4 on concrete surfaces over top of roof slabs to receive water proofing treatment, finished even and fair, complete all as specified and as directed.
Supply only Liquid integral water proofing admixture, complete all as specified and as directed.
Applying evenly a tack coat of industrial bitumen 85/[email protected]/Sqm over a coat of primer @ 0.5Ltr/Sqm to the cleaned concrete surfaces. Laying APP modified membrane weighing not less than 3.0Kg/Sqm and thickness of membrane not less than 3mm (Reinforced with polyster non woven fabric of weight not less than 150gms/Sqm) having water absorption of not more than 1% of mass within 24Hrs and water tightness/impermeability at 2Kg/Sqm fixed with torch application method, complete all as specified and as directed.
Cement concrete tiles, factory made, Premium quality 200mm x 200mm x 20mm thick, set and jointed in neat cement slurry and pointed flush with cement mortar 1:3 mixed with 5% crude oil by weight of cement laid over 15 mm thick screed bed or bedding layer in cement mortar 1:4, laid over APP treatment, complete all as specified and as directed.
75mm thick PCC 1:4:8 type D-2 using 40mm graded crushed stone aggregate, as in sub base to receive topping layer finished even and rough, complete all as specified and as directed.
Non skid ceramic coloured floor tiles 400mm x 400mm x 7-8mm thick as in floors, set and jointed in neat cement slurry and pointed in white cement with pigments to match over and including the provision of 15 mm thick bedding layer in cement mortar 1:4, complete all as specified and as directed.
Non skid ceramic coloured floor tiles 300mm x 300mm x 7-8mm thick as in floors, set and jointed in neat cement slurry and pointed in white cement with pigments to match over and including the provision of 15 mm thick bedding layer in cement mortar 1:4, complete all as specified and as directed.
Glazed Coloured Ceramic tiles in vertical surface 300mm x 200mm x 7mm thick set and joint in neat cement slury and pointed in white or colour cement to match laid over 10 mm thick screed bed in cement mortar 1:4, complete all as specified and as directed.
Rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 finished even and smooth without using extra cement, complete all as specified and as directed.
Rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 finished even and smooth without using extra cement, complete all as specified and as directed.
Cutting grooves in brick or stone wall 75mm wide and 40mm deep and shaping horizontal face of groove with cement mortar 1:3, complete all as specified and as directed.
15mm bore GI tubing (medium grade) with all fittings and fixed complete to walls and ceiling or laid in floors/roofs, complete all as specified and as directed.
20mm bore GI tubing (medium grade) with all fittings and fixed complete to walls and ceiling or laid in floors/roofs, complete all as specified and as directed.
25mm bore GI tubing (medium grade) with all fittings and fixed complete to walls and ceiling or laid in floors/roofs, complete all as specified and as directed.
100mm bore cast iron soil, waste and vent pipes in any length with or without ears with cement joints fixed to walls, or laid in floors, complete all as specified and as directed.
75mm bore cast iron soil, waste and vent pipes in any length with or without ears with cement joints fixed to walls, or laid in floors, complete all as specified and as directed.
CI bend for 100mm bore any radius, diminishing pieces or tapers (larger bore measured), fixed to walls, complete all as specified and as directed.
CI bend for 75mm bore any radius, diminishing pieces or tapers (larger bore measured), fixed to walls, complete all as specified and as directed.
CI bend for 50mm bore any radius, diminishing pieces or tapers (larger bore measured), fixed to walls, complete all as specified and as directed.
CI Branch pieces with oval access door for 100mm bore pipe fitting, double (equal or unequal, ordinary or inverted) (spigot or socket type) or with parallel branches, complete all as specified and as directed.
CI Branch pieces with oval access door for 75mm bore pipe fitting, double (equal or unequal, ordinary or inverted) (spigot or socket type) or with parallel branches, complete all as specified and as directed.
CI Branch pieces with oval access door for 50mm bore pipe fitting, double (equal or unequal, ordinary or inverted) (spigot or socket type) or with parallel branches, complete all as specified and as directed.
CI floor trap/Nahani trap, with grating including jointing to 75mm bore waste pipe fixed in cement concrete 1:2:4, type B-1, complete all as specified and as directed.
CI 'P' or 'S' trap 100mm bore, complete all as specified and as directed.
CI cowl including jointing to 100mm bore waste pipe fixed in cement joints, complete all as specified and as directed.
CI cowl including jointing to 75mm bore waste pipe fixed in cement joints, complete all as specified and as directed.
CI cowl including jointing to 50mm bore waste pipe fixed in cement joints, complete all as specified and as directed.
CI oval access door covers for 100 bore cast iron pipe fittings, fixed in position, complete all as specified and as directed.
CI oval access door covers for 75 bore cast iron pipe fittings, fixed in position, complete all as specified and as directed.
PVC 110mm bore (SWR) pipes double socketed, in any length with rubber ring joints, flaid in trenches or in floors, complete all as specified and as directed.
PVC 75mm bore (SWR) pipes single socketed, in any length with rubber ring joints, flaid in trenches or in floors, complete all as specified and as directed.
PVC 50mm bore (SWR) pipes single socketed, in any length with rubber ring joints, flaid in trenches or in floors, complete all as specified and as directed.
PVC (SWR) bend of 110mm bore any radius, complete all as specified and as directed.
PVC (SWR) bend of 75mm bore any radius, complete all as specified and as directed.
100mm bore stack clamps out of 50mm by 5mm flat iron and 16mm dia round iron stays, including securing ends of stays to wall or roof, fixed in repairs, complete all as specified and as directed.
75mm bore stack clamps out of 50mm by 5mm flat iron and 16mm dia round iron stays, including securing ends of stays to wall or roof, fixed in repairs, complete all as specified and as directed.
Racking out cement/lead joints of CI pipes 100mm/75mm dia and filling with lead joints/neat cement mortar to stop leakage of joints, complete all as specified and as directed by Engineer-in-Charge.
Rotational moulded polythylene water storage tanks 500 ltr capacity (cylindrical vertical with closed top ) hoisted and fixed in position complete with ball valve of high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball and screwd for iron pipe 20mm bore, complete all as specified and as directed.
15mm bore ball valves high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball, screwed for iron pipe and fixed minimum weight -210gms, fixed in repairs, complete all as specified and as directed.
20mm bore ball valves high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball, screwed for iron pipe and fixed minimum weight -210gms, fixed in repairs, complete all as specified and as directed.
25mm bore ball valves high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball, screwed for iron pipe and fixed minimum weight -210gms, fixed in repairs, complete all as specified and as directed.
15 mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both end for iron pipe, fixed in repairs, complete all as specified and as directed.
20 mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both end for iron pipe, fixed in repairs, complete all as specified and as directed.
25 mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both end for iron pipe, fixed in repairs, complete all as specified and as directed.
SGSW pipe 150 mm dia including jointing with cmenet mortar, complete all as specified and directed.
SGSW pipe 200 mm dia including jointing with cmenet mortar, complete all as specified and directed.
SGSW gully trap of size 150mm x 150mm and jointing with cement mortar and taking out old existing gully trap with old connections and pipe, complete all as specified and directed.
150mm internal dia RCC hume pipe class NP-2, laid in trenches and jointed in cement mortar, complete all as specified and directed.
200mm internal dia RCC hume pipe class NP-2, laid in trenches and jointed in cement mortar, complete all as specified and directed.
Cement concrete type D-2 1:4:8 (using 40 mm graded crushed stone aggregate) in bed to drain pipe 150 mm dia including packing under and haunching against the sides of pipe after they are laid and tested complete all as specified and directed.
Cement concrete type D-2 1:4:8 (using 40 mm graded crushed stone aggregate) in bed to drain pipe 200 mm dia including packing under and haunching against the sides of pipe after they are laid and tested complete all as specified and directed.
Cutting into existing manholes including cuttng out existing benching for connecting new drains and forming branch channel (1/2 or 3/4 section), making good to pipe in cement concrete 1:2:4 type B-1 and finished smooth and reforming benching as required for 200mm dia pipe, complete all as specified and as directed.
PVC 10 Ltrs valve less, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets complete with flush pipe etc. ISI approved, fixed in repairs, complete all as specified and as directed.
Vitreous china squalting pan of Orrisa pattern long pan size 580mm x 440mm white with 'P' or 'S' trap front or back inlet and foot rest any pattern including connection to trap and to flushing pipe etc complete including lime concrete bedding and making good to floor, fixed in repairs, complete all as specified and as directed.
Vitreous china wash down water closet pan pedestal pattern white including connection in drain and in flushing pipe complete including 'P' or 'S' trap, fixed in repairs, complete all as specified and as directed.
Cleaning and removing all scale and dirt, etc, from tanks and from mouth of circulating pipes etc., of capacity not exceeding 500 Ltrs complete including writing date of cleaning with approved quality synthetic enamel paint, complete all as specified and as directed.
Cleaning and removing all scale and dirt, etc, from tanks and from mouth of circulating pipes etc., of capacity exc 500 Ltrs and not exceeding 1000 ltrs complete including writing date of cleaning with approved quality synthetic enamel paint, complete all as specified and as directed.
Disconnecting existing tanks of capacity exceeding 500Ltrs but not exceeding 1000Ltrs any shape, setting aside (or lowering if required) for repairs, cleaning , etc. and hoisting if required reconnecting and re-fixing in position, complete all as specified and as directed.
Precast SFRC square or rectangular manhole covers of size 450mm x 450mm 80mm thick with frame medium duty conforming to IS-12592 including necessary hold fasts and hooks, complete all as specified and as directed.
Precast SFRC square or rectangular manhole covers of size 900mm x 450mm 80mm thick with frame medium duty conforming to IS-12592 including necessary hold fasts and hooks, complete all as specified and as directed.
Cleaning of any sort of blockages in old sewage line of any dia and removing sludge dislodged to a place outside MOD land, complete all as specified and as directed.
Cleaning of Manholes exceeding 1.5mtr deep and not exceeding 3.00mtr deep including bailing out water, from it and removing sludge and blockages from inlet and outlet of sewer lines including taking out the excavated sludge and carting away the same to a distance far away from residential/office area and cover the same with fresh earth and recommissioning the septic tank including and disposing waste materials out side defence land strictly as per Hon'ble Supreme Court directions, complete all as specified and as directed by Engineer-in-Charge.
Dewatering of soak wells, sump wells including bailing out water from it and removing sludge and blockages from inlet and outlet of sewer lines including taking out the excavated sludge and carting away the same to a distance far away from residential/office area and cover the same with fresh earth and recommissioning the same including and disposing waste materials out side defence land strictly as per Hon'ble Supreme Court directions, complete all as specified and as directed.
Cutting shrubs wild gorwth/trees exceeding 30cm girth and removing complete vegetation growth from walls including taking out roots from roof/brick work or concrete surfaces and making good the distrubed surfaces with PCC 1:2:4 type B-0, using 12.5mm graded crushed stone aggregate and disposing the rubbish from the site (MOD land) for a block of eleven multistoried flats, complete all as specified and as directed by the Engineer-in-Charge. ( Note : Rate in this item include cutting tress and shrub in each block any number of time during the currency of contract.)
CI fittings such as Tees, bends, branch pieces, floor traps etc., upto 100mm dia (waste water/rain water/soil waste pipe) where ever required to stop leakage including testing of leakage upto eight storied building, fixed in repairs, complete all as specified and as directed. Note :- The necessary steel scaffolding upto eight storeyed whereever required to complete the job shall be provided by the contractor with all safety equipments and the rate for scaffolding & safty equipments shall be deemed to be included in the quotted rates by the contractor and nothing extra shall be paid on this account.
PVC/UPVC fittings such as Tees, bends, branch pieces, floor traps etc., upto 100mm dia (waste water/rain water/soil waste pipe) where ever required to stop leakage including testing of leakage upto eight storied building, fixed in repairs, complete all as specified and as directed. Note :- The necessary steel scaffolding upto eight storeyed whereever required to complete the job shall be provided by the contractor with all safety equipments and the rate for scaffolding & safty equipments shall be deemed to be included in the quotted rates by the contractor and nothing extra shall be paid on this account.
Cleaning of sewage lines any dia with Mechanically operated 25 tonne truck mounted desludger with 12000Ltr capacity tanker having water fitted high pressure jet machine for cleaning and desludging of sewage line, soak wells, septic tanks etc., shall be used by the contractor as per scheduled programme in writing and completion of each job to the entire satisfaction of Engineer-in-Charge as instructed. ( NOTE : a) In case contractor fails to deploy the machine as per scheduled programme a recovery of Rs 1500/- per day shall be deducted from his payment.)
Breaking up drain pipes (SGSW/AC/RCC) of any size by puncturing, cleaning of blockage by roding and making good of broken/punctured portion of pipes by changing of drain pipes (SGSW/AC/RCC) and sealing the joints with cement mortar 1:3 or PCC 1:2:4 type B-1 for no leakage including necessary earth work, excavation in any type of soil upto any depth, returning filling and removal of surplus soil to a distance not exc 50 mtr from the starting point, complete all as specified and as directed by Engineer-in-Charge.
Removing of rubbish, mud, surbs, vegitation etc from existing drain including removing and replacing of covers, cleaning to make the drain serviceable completely including removing the taking out materials to a distance exc 50mtr or in suitable location complete all as specified and as directed.
Cleaning and maintenance of rain water pipes, open drains, sewage system including WHB bottle traps, Nahani traps, water closet, soil / wastage pipe running on external walls of bldgs, junction holes of any description, sewage line of any sizes including manholes upto the final drop outlet into the septic tank of external sewage system in running / flowing order without blockage of any description in any situations including making Julla arrangement to work in high rise buildings externally upto 8 stories height and clearing of blockages by mechanical means or manually and disposing waste materials out side defence land strictly as per Hon'ble Supreme Court directions, complete all as specified and as directed by the Engineer-in-Charge.
NOTE: a) The above task shall be caried out by deploying 06 safaiwalas on all days including Sundays and Holidays between 0900 Hrs to 1700Hrs, Two numbers for each pocket of (i) Kabul Lines- 02 Nos. (ii) FAFA- 02 Nos. and (iii) OTM ACCNs Area - 02 Nos. b) One mechanical pump diesel/petrol for dewatering sludge water, safety belt, ladder, gloves gasmask, bucket to remove sludge, mechnical device required to reach work at difficult locations shall be made available all time at site to ensure heigene and sanitation during work. c) Daily attendance shall be maintained in the Attendance Register by the JE concerned and a recovery for absent period shall be made @ Rs 500/- per person per day. All relevent record shall be maintained by the contractor and to be submitted before making any payment duly signed by Engineer-in-Charge & JE concerned. d) Work will be carried out in Multistoreyed Building upto 08 storeys and Jula arrangement including all safety measures are to be provided by the contractor under his own arrangement, rate of which are deemed to be included in the rates quoted against above mentioned item.
NOTE:- Irrespective of whatever specified elsewhere in tender documents, all the debris/waste materials produced out of above mentioned work shall be removed out of Cantonement land and disposed off at locations notified by the Delhi Cantonment Board for disposal of waste building materials within NCR area, without any extra cost to Department under own arrangement of contractors. The rates quoted by the contractors against the items catered here-in-above in the BOQ are inclusive of said provision.
sunil traders
MAA SANTOSHI ENTERPRISES
S GOURAV PRAKASH ENTERPRISES
SHRI RAM CONSTRUCTION CO
om shani enterprises
Simran construction Company
LAMBA ENTERPRISES
Vipul Construction
VED PRAKASH ARORA
Baljeet Builders & Interior Decorators
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .