Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.8 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹35.8 L+₹1.1 L (3.06%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹39.8 L+₹5.0 L (14.4%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | Rejected-Technical | - | Rejected-Technical Because major contracts are in slow progress or stopped by contractor and recommendation fwd for not capable of handling more load in QE JUN 2022 WLR REPORT |
Tender Value
Refer Docs
EMD Value
₹96,000
Closing Date
1 Aug 2022, 6:00 pmClosed
GE BHOPAL
GE BHOPAL BAIRAGARH BHOPAL
REPAIR REPLACEMENT OF LT CABLE AND MAINT OF EXT LT ELECTRIC SUPPLY AND STREET LIGHTS SECURITY LIGHTS SOLAR LIGHTS AND REPAIR REPLACEMENT OF SEWAGE LINE CLEANING OF SEWAGE LINE SEPTIC TANK MANHOLES AT ADMINISTRATIVE AREA CPE ITARSI UNDER GE BHOPAL
2022_MES_534910_1
8900/E8
Open Tender
Electrical and Maintenance Works
Item Rate
274 days
ITARSI
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE BHOPAL
₹96,000
Yes
14 Sept 2022
30 Jun 2022
3 Aug 2022
30 Jun 2022
1 Aug 2022
19 Jul 2022
Amount
Note :(i) Please refer Sch A/ BOQ Notes before quoting the tender for all phases/ items mentioned below. (ii) Amount of Schedule of credit shall be deducted offline
This work comprises of (i) REPAIR/ REPLACEMENT OF LT CABLE AND MAINT OF EXT LT ELECTRIC SUPPLY AND STREET LIGHTS, SECURITY LIGHTS, SOLAR LIGHTS AT ADMINISTRATIVE AREA, CPE ITARSI (ii) REPAIR/ REPLACEMENT OF SEWAGE LINE, CLEANING OF SEWAGE LINE, SEPTIC TANK, MANHOLES AT ADMINISTRATIVE AREA, CPE ITARSI UNDER GE BHOPAL The qty of individual part shall not vary beyond deviation limit specified in tender. Note :(i) Please refer Sch A/ BOQ Notes before quoting the tender for all phases/ items mentioned below. (ii) Amount of Schedule of credit shall be deducted offline
REPAIR/ REPLACEMENT OF LT CABLE AND MAINT OF EXT LT ELECTRIC SUPPLY AND STREET LIGHTS, SECURITY LIGHTS, SOLAR LIGHTS AT ADMINISTRATIVE AREA, CPE ITARSI
Restringing of HT/LT over head line conductor comprising of any size ACSR conductor / GI wire on existing pole after opening from insulator by taking out of binding wire and refixing the same with suitable size of binding wire upto permissible sag after restringing including cutting of tree branches and trimming of smaller branches of any size up to 2 metre each side of OH line which touch/ falling on the OH line without damaging of 4 wire (3 phase and neutral) span exc 25.00m but n. exc 35.00m, complete all as specified and directed.
All as per Sl. item No. 1.30 here in above but 6 wire (3 phase, neutral and street light) span exc 25.00m but n. exc 35.00m, complete all as specified and directed.
M&L shackle type porcelain vitreous white or brown insulator (For LT) working pressure 1100 volts including galvnised mild steel straps of size 31X 3 mm and 12 mm dia insulator bolts, washers and nuts etc including dismantling unserviceable insulator of any size complete all as specified and directed.
M&L pin type insulator of size 100 mm height, 65 mm dia porcelain vitreous white or brown/green insulator (For LT) for working pressure 1100 volts with one galvanised spindle and two galvanised iron washers and nut including dismantling unserviceable insulator of any size complete all as specified and directed.
S&F in replacement stay assembly comprising of galvanised iron stay bow of size 40 cm X14 cm, 20 mm dia & 1800 mm long GI stay rod including excavation, PCC, GI nuts MS stay plate 300 mm X 300 mm X 6 mm, 2 No thimble, 50X6 mm flat iron stay clamp, Steel stay wire 16 mm dia bolts , nuts and washers etc including taking down unserviceable stay assembly of any size complete all as shown in electrical plate No 1 of MES SSR 1991 Part 1, complete all as specified and directed.
Material and labour for GI tubing light grade, 50mm dia with all necessary fittings, laid in trenches, under floor/road crossing, fixed on poles for cable protection fixed with the clamps made out of FI 25 x 3mm duly painted with two coats of aluminium paint over a coat of approved primer etc. including taking down old unserviceable any size and capacity of GI pipe complete all as specified and directed.
Material and labour for GI tubing light grade, 80mm dia with all necessary fittings, laid in trenches, under floor/road crossing, fixed on poles for cable protection fixed with the clamps made out of FI 25 x 3mm duly painted with two coats of aluminium paint over a coat of approved primer etc. including taking down old unserviceable any size and capacity of GI pipe complete all as specified and directed.
Material and labour for cross arms, bracings, supports, clamps and back plates fabricated from structural steel section including nuts, bolts, washers etc, welding, bending cold or hot, drilling holes for bolts, in any shape or size as directed and inclusive of applying one priming coat and two coats of synthetic enamel paint/aluminium paint including taking down corroded items of any type and size complete all as specified and directed.
Material and labour replacement of GI cradle guard hexagonal / rectangular with galvanised steel wire of 3.15mm to 4 mm dia including taking down unserviceable GI craddle of any size and type complete all as specified and directed.
Supply and fix galvanised steel continuous earth wire of size 4.00 mm including taking down unserviceable GI earth wire of any size and type complete all as specified and directed.
Supply and fix and stringing of OH electric ACSR conductor of any size fixing to insulator with necessary binding wire of suitable size including taking down unserviceable ACSR conductor of any type and size complete all as specified and directed. Note:- (i) 3% extra will be added to the weight for sagging. (ii) Binding and jointing will not be considered for measurement and all the jumper shall be fixed with minimum 6 pg clamps and the quoted rate shall deemed to be include in the unit rate quoted.
Material and labour for errection in position including steel tubular swaged poles type 410 SP-31 (09.00 metres long) complete with cast iron base plate, finial taper plug, bolts, nuts, screws and top cover all as specified and including the following:- (a) Excavation in trenches not exceeding 1.5 mtr wide and 2 mtr deep for pole foundation and getting out in soft/ loose soil, returning filling in the excavation of soil after fixing the pole in foundation ramming earth around in layer not exc 25cm thick and disposal of surplus soil to a distance not exc 50 mtrs. (b) Material and labour for providing PCC 1:4:8 type D-2, using 40mm graded stone aggregate as in foundation, 600 X 600 mm cross section planting depth 1.8 mtr for concrete casing the pole upto GL complete all as directed. (c) Material and labour for providing PCC 1:3:6 type C-2, using 40mm graded stone aggregate for plinth block/collar above GL 300 mm high and 450mm dia all as directed. (d) Material and labour for painting of pole externally with one coat of black bituminous paint (upto planting depth) and above plinth block/concrete collar with two coat of aluminium paint over a coat of red oxide steel primer including preparation of surface including painting of 30cm wide blue bands 3 Nos. with synthetic enamel paint in alternate layer upto the height of 1.5m above plinth block. (e) Material and labour for writing letter or figures (Block, Roman, italic as Indian) with thick synthetic enamel paint of approved shade not exc height in numbering of pole all as directed.
Supply, installation, testing and commissioning in replacement of automatic power factor correction (APFC) pannel for 3 phase 415V &50 Hz system of capasity 100 KVAR, factory made, out door type both side opening, (frount and rear side) weather and vermin proof panel having degree of protection IP-43 & made out of CRCA fabricated out of sheet of 3.15 mm outer structure and 1.6mm for internal structure with duly powder coated,CPRI approved , factory made fabricated and CPRI approved, 415 volts, with locking arrangement, powder coated MS angle iron base frame with legs of size 40 X 40 X 60mm and 60cm long grounted with PCC 1:3:6 type C-1 for foundation filling with platform 100 X 75 X 15 cm above ground level floor incuding Cable connection with appropriate MCCB & MCB, complete all as specified and directed.
Supply and install in Replacement of capacitor, metalized poly propylene heavy duty (MPP-H) three phase, 415 volts and 50 Hz system for permissible non-linear load 15 % of 10 KVAR capacity to maintain power factor complete all as specified and directed.
Supply and install in replacement of capacitor, metalized poly propylene heavy duty (MPP-H) three phase, 415 volts and 50 Hz system for permissible non-linear load 15 % of 15 KVAR capacity to maintain power factor complete all as specified and directed.
Supply and install capacitor, metalized poly propylene heavy duty (MPP-H) three phase, 415 volts and 50 Hz system for permissible non-linear load 15 % of 25 KVAR capacity to maintain power factor complete all as specified and directed.
Material & labour for earthing galvanized steel earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr depth below normal ground level) with top edge of earth not less than 1.5 mtr below normal ground level connected to and including galvanized steel strip 32 mm x 6 mm as earth lead upto equipment by means of steel bolts, nuts, check nuts and washers, test point made of GI strip 40x8mm, 10cm long PCC 1:2:4, type B-1 in pit with precast RCC 1:2:4 type B-1 in cover reinforced with XPM not less than 4 Kg per Sqm with 40mm bore GI light grade protection pipe, 20mm bore GI medium grade watering pipe with funnel including charcoal, dust, salt, all as shown in electric plate No 3 of SSR Part-I (2009) Specifications, complete with necessary earth work in any type of soil, removal to a distance not exceeding 50 mtr including testing on completion & dismantling of existing earthing, complete all as specified and directed.
Material and labour for painting to steel tubular pole with aluminium enamel paint of 9.00 Mtr including cross arms, clamps any size and nuts, bolts etc with one coat of aluminium synthetic enamel paint including preparing the surfaces free from finish particalsand making the smooth surface and numbering on pole with black ground such as pole number and source of supply, painting with radium paint around the pole at width of 10cm, similar three rounds from 1.5 m GL top on circumferance of pole complete all as specified and directed.
All as per item No 18.00 above but steel tubular pole of 11 Mtr long, complete all as specified and directed.
Material and labour PVC line spacer for LT over head line complete all as specified and directed. (Note- Required T&P will be arranged by contractor no extra cost shall be paid)
Cutting and trimming of trees and branches to clear the over head line in the arc of HT/LT over head line feeders and removal of the trimmed branches of trees complete all as specified and directed. Notes : 1. Any ACSR conductor damaged during the cuttings of trees / branches shall be repaired and jointed / fixed by the contractor, to the entire satisfaction of Engr-in-Charge, without any extra cost and nothing extra shall be admissible from the department on this account what-so-ever. 2. The cutting / trimming of tree branches shall be done to atleast 2.00 metre radius of OH line. 3. The unit of measurement is 'SPAN' i.e. distance covered between two poles.
S&F in repair on load change over switch 125 Amps 4 pole 415 volts 50 Hz . With S S Enclosure including taking down unserviceable one complete all as specified and directed.
S&F off load changeover switch in sheet metal enclosure, heavy duty, 200 Amps, four pole, 415 Volts AC, 50 Hz with side handle including connectins complete all as specified and directed.
S&F off load changeover switch in sheet metal enclosure, heavy duty, 320 Amps, four pole, 415 Volts AC, 50 Hz with side handle including connectins complete all as specified and directed.
S&F Switch Fuse Unit in sheet metal enclosure, heavy duty, 63 Amps, four pole, 415 Volts AC, 50 Hz with side handle including connections complete and removing existing unserviable switch fuse unit complete all as specified and directed.
M&L for replacement of Switch fuse unit heavy duty, including Sheet metal enclosure with TPN of capacity 125 Amps complete all as specified and directed.
M&L for replacement of Switch fuse unit heavy duty, including Sheet metal enclosure with TPN of capacity 200 Amps complete all as specified and directed.
Supply and fix in replacement of single phase multi function electric energy LCD sub meter 5-30Amp, 2 wire, 240V 50HZ complete all as specified and directed.
M&L in replacement of MCCB of follwoing sizes fixed with thermal & magnetic setting with extended terminals,replacemenr to LT panel/ Feeder piller box including connecting lugs with busbar and including mounting arrengments e.i. screws,bolt, nut, washers incl taking out old unsv complete all as specified and directed.
400 Amp, 4 pole, 415 volts, adjustable type with breaking capacity 36 KA
350 Amp, 4 pole, 415 volts, adjustable type with breaking capacity 36 KA
200 Amp, 4 pole, 415 volts, adjustable type with breaking capacity 36 KA
160 Amp, 4 pole, 415 volts, adjustable type with breaking capacity 36 KA
100 Amp, 4 pole, 415 volts, adjustable type with breaking capacity 16 KA
63 Amp, 4 pole, 415 volts, adjustable type with breaking capacity 16 KA
Supply, laying, jointing with suitable thimble and cable gland, testing and commissioning or fixing in wall or passing through pipe, 1100 volts grade heavy duty with XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor including making input and output connections with using suitable size of thimbles, lugs, and glands complete of following cross sectional area as under including taking down Old UNSV cable, complete all as specified and directed. :-
120 Sqmm 3.5 Core
95 Sqmm 3.5 Core
70 Sqmm 3.5 Core
50 Sqmm 3.5 Core
35 Sqmm 3.5 Core
25 Sqmm 3.5 Core
16 Sqmm 4 Core
16 Sqmm 2 Core
Supplying and fixing in replacement of 1100 volts grade heavy duty cable of size 10 Sqmm PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspen ded by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular complete all as specified and directed.
M&L in replacment of 1100 Volts grade, heavy duty cable, PVC insulated copper cable, served with inner sheathing of PVC tape and overall PVC sheathed for hight mast light connection cicrular of size 4 Sqmm three core cable round type stranded conductor complete all as directed incl taking down old unsv complete all as specified and directed.
M&L in replacment of 1100 Volts grade, heavy duty cable, PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed for street light connections cable flat or cicrular of size 6 Sqmm twin core cable stranded conductor complete all as directed incl taking down old unsv complete all as specified and directed.
Supply, jointing, testing straight through jointing kit cold shrinkable out door type, suitable for LT 1100 Volts grade cable of size 95 Sqmm to 120 Sqmm 3.5 core complete all as specified and directed.
Supply, jointing, testing straight through jointing kit cold shrinkable out door type, suitable for LT 1100 Volts grade cable of size 50 Sqmm to 70 Sqmm 3.5 core complete all as specified and directed.
Supply, jointing, testing straight through jointing kit cold shrinkable out door type, suitable for LT 1100 Volts grade cable of size 25 Sqmm to 35 Sqmm 3.5 core complete all as specified and directed.
Supply, jointing, testing end termination jointing kit cold shrinkable out door type, suitable for LT 1100 Volts grade cable of size 70 Sqmm to120 Sqmm 3.5 core complete all as specified and directed.
Supply, jointing, testing end termination jointing kit cold shrinkable out door type, suitable for LT 1100 Volts grade cable of size 25 Sqmm to 50 Sqmm 3.5 core complete all as specified and directed.
Excavation in trenches in any type of soil n. exc 1.5 m wide and n. exc 1.5 m in depth and getting out for foundation of pole, laying under ground cables etc and getting out complete all as specified and as directed. (E/M + B/R)
Material and labour for river washed and screened dry sand for filling in trenches below and around the cable for cushioning including punning down as specified in relevant clause of SSR Part I, complete all as specified and directed. Note: Punned thickness shall only be measured and paid.
Material and labour for well burnt brick sub class 'B' old size bricks laying in trenches perpendicular to axis of the cable complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers n. exc 25 cm in soil complete all as specified and directed. (E/M + B/R)
Removing excavated soil to a distance n. exc 50m and deposited at a level n.exc 1.5m above the starting point complete all as specified and directed. (E/M + B/R)
Supply and fixing LED street light fitting of following watts/sizes 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
35 Watt LED light
60 Watt LED light
70 Watt LED light
90 Watt LED light
Supply and fixing LED flood light following watts/sizes 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed.
120 Watt LED Flood Light
170 Watt LED Flood Light
Supply and fix in replacement of Solar street light LED type fittings (With inbuilt CCU) 1x20 Watt made out of pressure dia cast aluminium, with IP-66 protection including all control driver and LED lamps suitable for Solar street pole including 9.00 mtr Steel Pole suitable for light fitting complete including taking down the existing unserviceable solar light fittings of any capacity and removing from the site complete all as specified and directed. (NOTE- Earth work shall be deemed to included in quoted rate)
Supply and fixing post top lantern LED type 20 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed.
Supply and fix in GI pipe 50mm dia, medium grade for mounting bracket bent to shape 1.75 meter length and fixing arrangement with two Nos of MS clamps set, nut, bolts, washers, and applying two coats of aluminium paints over one coat of Zinc oxide primer complete all as directed incl taking down old unsv complete all as specified and directed.
Supply and fix in GI pipe 40mm dia, medium grade for mounting bracket bent to shape 1.75 meter length and fixing arrangement with two Nos of MS clamps set, nut, bolts, washers, and applying two coats of aluminium paints over one coat of Zinc oxide primer complete all as directed incl taking down old unsv complete all as specified and directed.
Supply and fix in replacment of pole mounted junction box (sintex box) size 340 X 160 X 90 mm with porcelain connector 2 Nos, colour coaded aluminium bus bar of rating 63 amps mounted on non cracking epoxy insulators, MCB SP 10Amps, 250 volts, 'C' curve - 02 Nos. Mounted in including provisioning of mounting arrangements with clamps, nut, bolts, and washer etc for fixing to pole, drilling with proper hole for incoming and outgoing cables of suitable size , conecting existing cables with bus bar complete all as directed incl taking down old unsv complete all as specified and directed.
Taking down unserviceable Street/Security light fitting of any type from the pole and fixing after completion of repairs complete all as specified and directed. (Note: Repair/replacement of spares shall be measured seperately)
Supply and fixing in replacement of electronic driver of cap 35/45 watt of existing make for LED street light fitting complete all as specified and directed.
Supply and fixing in replacement of electronic driver of cap 60 watt of existing make for LED street light fitting complete all as specified and directed.
Supply and fixing in replacement of electronic driver of cap 70 watt of existing make for LED street light fitting complete all as specified and directed.
Supply and fixing in replacement of electronic driver of cap 90 watt of existing make for LED street light fitting complete all as specified and directed.
S&F aluminum lugs suitable for aluminum cable of size 16 Sqmm, complete all as specified and directed.
S&F aluminum lugs suitable for aluminum cable of size 35 Sqmm, complete all as specified and directed.
S&F aluminum lugs suitable for aluminum cable of size 50 Sqmm, complete all as specified and directed.
S&F aluminum lugs suitable for aluminum cable of size 70 Sqmm, complete all as specified and directed.
S&F aluminum lugs suitable for aluminum cable of size 95 Sqmm, complete all as specified and directed.
S&F aluminum lugs suitable for aluminum cable of size 120 Sqmm, complete all as specified and directed.
S&F Timer Switch (light sensor type nature switches), three phase plastic body degree of protection conforms to IP64, operating illumination level for switching ON should be less than 60 lux for 30 seconds and for switching off must be greater than 10 lux for 30 seconds, multiple option switch for automatic and manual operations, capable to handle lightning load up to 8 KW, including MCB capacity 63 Amp conforms to IEC-60898 and IS-8828, Power contactor capacity 40 Amp conforms to IEC 60947-4-1, IS 13947-4-1 completely enclosed with plastic body panel conforms to IP 54 degree of protection, after taking down the burned control gears and cleaning the existing MS panel board, duly painted with two coats of epoxy coloured spray paint including taking down the existing unserviceable timer switch of any capacity and removing the site complete all as directed and as specified.. (Make : Kakatiya Energy systems Pvt Ltd, Model No SWADEEP- 02EC8kW1P or equivalent make in Havells/ Legrand / ABB / Schneider
Replacement with old Synthetic insulation mat with new synthetic insulation mat for insulation for LT panels, Transformer or DG Set of size 2mtr x1mtr x 12mm thick all as specified and directed.
REPAIR/ REPLACEMENT OF SEWAGE LINE, CLEANING OF SEWAGE LINE, SEPTIC TANK, MANHOLES AT ADMINISTRATIVE AREA, CPE ITARSI UNDER GE BHOPAL
M&L for attending /cleaning daily complaints of blockage of floor traps, WCs (Indian/European) WHB traps, kitchen traps, urinal traps etc at ground floor or above ground floors with and including necessary T&P as required for this purpose :- Note : (a) Complaint slip shall collected by the contractor/supervisor from MES complaint cell and submit the same duly signed by the occupant at 1630hrs in the complaint cell. It will be responsibility of contractor to ensure their attendance & completion of complaints. (b) If any complaint not resolved within 24 hrs the recovery @ Rs 500 per complaint per day will be charged from RAR or Final Bill. (c) During cleaning of blockage remove grating will be refixed in existing position with white/grey cement afterclearing of blockage from trapes. (d) The contractor will ensure the cleaning /cleaning of all the complaints (Irrespective of Nos) within 24 hrs by deploying additional sewer man /safaiwala if needed. Nothing extra charge will be paid on this account (e) Contractor shall be solely responsible for supplying all the safety measures required by the sewer man/safaiwala during working hours. (f) All the waste material/sludge shall be disposed of out of MoD land.
Taking out RCC cover slab of septic tank of 100 users capacity carefully, taking out the sludge including foul water, collect the sludge in closed container and burried the same in earth pit below 30 cm of the gound level with in the defence land where directed by the Engineer-in-charge to a distance exc 250 m and n.exc 500 m, returning, filling in the earth in excavated pit after complete removal of sludge from the container, inlet and outlet pipe, M.S ring and septic tank complete cleaning with fresh water as directed and placing the RCC cover slab in position and set in CM 1:6 complete all as specified and directed
Taking out RCC cover slab of septic tank of 50 users capacity carefully, taking out the sludge including foul water, collect the sludge in closed container and burried the same in earth pit below 30 cm of the gound level with in the defence land where directed by the Engineer-in-charge to a distance exc 250 m and n.exc 500 m, returning, filling in the earth in excavated pit after complete removal of sludge from the container, inlet and outlet pipe, M.S ring and septic tank complete cleaning with fresh water as directed and placing the RCC cover slab in position and set in CM 1:6 complete all as specified and directed
Taking out RCC cover slab of septic tank of 25 users capacity carefully, taking out the sludge including foul water, collect the sludge in closed container and burried the same in earth pit below 30 cm of the gound level with in the defence land where directed by the Engineer-in-charge to a distance exc 250 m and n.exc 500 m, returning, filling in the earth in excavated pit after complete removal of sludge from the container, inlet and outlet pipe, M.S ring and septic tank complete cleaning with fresh water as directed and placing the RCC cover slab in position and set in CM 1:6 complete all as specified and directed
Cleaning of man holes of any size depth n.exc 60 cm to cleaned all as per item 68.00 here in before complete all as specified and as directed.
Cleaning of man holes of any size depth exc 60 cm and n.exc 1.20 mtr cleaned all as per item 68.00 here in before complete all as specified and as directed.
Cleaning man holes of any size depth exc 1.20 sqm cleaned all as specified all as per item No 68.00 here in before all as specified and directed
M&L for dewatering/ Desludging of existing main sewage receiving tank of size 6m dia and 5 m deep (inner tank and outer tank) by sewage sunction machine truck mounted equipped with sewage storage tank and dispose off foul material/sludge out side the defence land on the location enmarked by civil authorities complete all as specified and directed.
Dewatering/Desludging from existing soakage well of size 2.4 M dia X 3.0M deep by sewage suction machine truck mounting equipped with sewage storage tank and removing/dispose off foul material/sludge out side the defence land on the location enmarked by civil authorities complete all as specified and directed.
Dewatering/Desludging from existing soakage well of size 1.8 M dia X 3.0M deep by sewage suction machine truck mounting equipped with sewage storage tank and removing/dispose off foul material/sludge out side the defence land on the location enmarked by civil authorities complete all as specified and directed.
Dewatering/Desludging from existing soakage well of size 1.2 M dia X 3.0M deep by sewage suction machine truck mounting equipped with sewage storage tank and removing/dispose off foul material/sludge out side the defence land on the location enmarked by civil authorities complete all as specified and directed.
Material and labour loose filling with aggregate of guage 80 mm to 150 mm as in soak well /sokage pits /filter beds with broken bricks incl removed old brick beds complete all as specified and as directed.
M&L for Cleaning of chocked sewage line of any description and any dia from man hole to man hole with sewage cleaning rod washing down with fresh water and disposed off the sludge all as specified and directed . The complaint where cleaning is not possible by rodding and is to be cleared by braking existing line the item will be paid separetely in item herein after, complete all as specified and as directed.
M&L for cleaning of underground sewage lines of 150mm bore by excavation and breaking (Minimum two length) and removing the blockage, laying new pipes, re-joining with old pipes including haunching the new pipes with PCC (1:3:6) type C-2 (Using 40mm graded stone aggregate) in all situations where cleaning is not possible otherwise including returning, filling and disposal of surplus soil outside MoD land etc. Complete all as specified and directed.
Demolition of PCC in ground floors and paving not exc 15cm thickness (below or above ground level) complete all as specified and as directed.
Material and labour for 75mm thick PCC 1:3:6 type C-1 (using 20mm graded aggregate) as in pavement/plinth protection,plinth protection shall be laid in alternate bays and joints shall be filled with bitumastic gola with 80/25 bitumen (1 part bitumen mixed with 3 part of sand) surface finished fair and even complete all as specified and as directed.
Demolition of reinforced cement concrete of any description as in man hole / septic tank cover slabs in any position complete all as specified and as directed.
M&L for precast reinforced cement concrete type B1, (1:2:4) with using (20 mm graded stone aggregate) as in man hole / soak well cover slab set in CM 1:4 all as specified and as directed
M&L for RCC type B-1 (1:2:4) using 20 mm grades aggregate as in slabs as in septic tank cover slab set in CM 1:4 complete all as specified and as directed.
M&L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200mm thick (Horizontal or sloping) complete all as specified and as directed.
M&L for Cement plaster 10 mm thick in cement mortar 1:4 on concrete surface such as soffits of RCC chajja, roof projection columns and beams etc finished even and smooth without using extra cement complete all as specified and directed.
M&L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wires (annealed) not less than 0.9 mm dia or secured with clips complete all as specified and as directed.
Material & labour for deformed TMT bars 5 mm dia and over upto and including 10mm dia in stirrups, spacers and binders etc cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wires (annealed) not less than 0.9 mm dia or secured with clips complete all as specified and as directed.
Demolition of brickwork built in cement mortar including all quoins, arches, pillars etc. complete all as specified and as directed.
M&L for brick work with sub class 'B' bricks built in CM (1:6) straight or curved on plan exc 6m mean radius as in manholes etc. complete all as specified and directed.
Material and labour for Brickwork with sub- class ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified and directed.
Material and labour for Brickwork with sub class ‘B’ bricks in one brick thick honey comb walling, built in CM 1:4 as in soak well complete all as specified and directed.
Taking down cement plaster of any description on brick walls including raking out joints, hacking for key, scrubbing down with water complete all as specified and as directed.
M&L for rendering 15 mm thick on fair faces of brick wall mixed with water proofing compound as per manufacturer instruction (Water proofing compound paid for seperately) in CM 1:4 finished even and smooth without using extra cement as in man hole/ septic tank etc
Supply only intregal water proofing compound
M&L for rendering 15 mm thick on fair faces of concrete/brick wall surface in cement mortar 1:4 and finishing the surface even and smooth without using extra cement complete all as specified and as directed.
Dismantling of SGSW drain pipes/NP-2 pipe of any bore jointed in cement mortar of any size and description including concrete bed and packing/ haunching of any type, complete all as specified and directed.
M&L for sail-glazed stoneware drain pipes of Internal diameter of pipe in 150mm laid in trenches and jointed complete all as specified and directed.
M&L for cement concrete (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation etc, complete all as specified and directed.
M&L for 200mm dia RCC pipes class NP-2 laid in trenches and jointed with cement mortar and tested complete all as specified and directed.
M&L for Concrete bed to drain pipe including packing under hanching against the side of pipes, 150mm, in cement concrete (1:4:8) type D-2 (using 40mm graded stone aggregate) after laying and testing of pipe complete all as specified and directed.
M&L for Concrete bed to drain pipe including packing under hanching against the side of pipes, 200 mm bore, in cement concrete (1:4:8) type D-2 (using 40mm graded stone aggregate) after laying and testing of pipe complete all as specified and directed.
M&L for cement conctete type B-1, 1:2:4 (using 20 mm graded stone aggregate) as in benching and coping complete all as specified and as directed.
S&F 100mm dia. Cast iron soil waste and vent pipes (Sand cast pipe), in any length with or without ears, with cement joints, fixed to wall/floor etc incl taking down of existing pipe complete all as specified and directed.
S&F 75mm dia. Cast iron soil waste and vent pipes (Sand cast pipe), in any length with or without ears, with cement joints, fixed to wall/floor etc complete all as specified and directed.
S&F in repair vitreous china squtting pan "ORISSA PATTERN" size 580x440mm white with integral foot rest and flush pipe complete including provision of concrete bedding 1:2:4 type BO, complete all as specified and directed.
Supply and fixing in repair Vitreous china EWC 'P' or 'S' Trap , white including Plastic water closet seat cover, white closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device suitable for EWC, making good to floor fixing bolt complete all as specified and directed.
M&L for non skid coloured ceramic edge cut tiles 7-8mm thick (square/ rectangular) area of each tile exceeding 0.06sqm but n.exceeding 0.11sqm as in floors set & jointed in neat cement slurry & pointed in white or coloured cement to match the tiles over and including screed bed 15mm thick in cement mortar (1:4) for laying floor finished complete all as specified and directed.
S&F 100mm dia cast iron bend, complete all as specified and directed.
S&F cast iron branch pieces (equal or unequal) or double parallel branches (100mm dia.) complete all as specified and directed.
S&F cast iron socket 100mm dia. (double coller) complete all as specified and directed.
S&F PVC (SWR) pipes 110 mm dia. single socketed, in any length with rubber ring joints, fixed to wall complete all as specified and as directed.
S&F PVC (SWR) bend 110 mm dia with access door complete all as specified and as directed.
S&F PVC (SWR) bend 110 mm dia without access door complete all as specified and as directed.
S&F PVC (SWR) junction single 110 mm bore, (single T) equal or unequal with access door complete all as specified and as directed.
S&F PVC (SWR) 110mm bore vent cowl complete all as specified and as directed.
S&F PVC (SWR) pipes 75 mm dia. single socketed, in any length with rubber ring joints, fixed to wall incl demolation of existing pipe complete all as specified and as directed.
S&F PVC (SWR) bend 75 mm dia with access door complete all as specified and as directed.
S&F PVC (SWR) bend 75 mm dia without access door complete all as specified and as directed.
S&F PVC (SWR) 75 mm bore vent cowl complete all as specified and as directed.
S&F cast iron floor trap 100 mm dia with gratings includings jointing to waste pipe fixed in cement concrete type B-1 1:2:4 complete all as specified and as directed.
S&F cast iron floor trap 75mm dia with gratings includings jointing to waste pipe fixed in cement concrete type B-1 1:2:4 complete all as specified and as directed.
S&F PVC (SWR) gully trap 125/110mm, setting and jointing with solvent cement concrete type B-1 1:2:4 complete all as specified and as directed.
S&F CI vent pipe 100mm dia with or without ears with cement joints laid in wall, complete all as specified and directed.
S&F CI cowls 100mm dia, complete all as specified and directed.
S&F CI Branch pipes100 dia (equal or unequal) with parellel branches, complete all as specified and directed.
Schedule of credit (calculation will be done off line) Rs. 96,795.00
M/s SHIVRATAN CONSTRUCTION
TANUJ CONST. CO.
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .