Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.4 LAccepted-AOC JAISALMER | JAISALMER | RAJASTHAN | 342310 | L1 | Accepted-AOC L1 | |
| 2 | L2₹41.7 L+₹2.8 L (7.07%)Rejected-Finance JAISALMER | JAISALMER | RAJASTHAN | 342310 | L2 | Rejected-Finance Not being lowest | |
| 3 | L3₹44.6 L+₹5.7 L (14.5%)Rejected-Finance | L3 | Rejected-Finance Not being lowest | |
| 4 | L4₹46.3 L+₹7.4 L (19.0%)Rejected-Finance GANDHI CHOWK MANIPURA JAISALMER RAJ 345001 | JAISALMER | JAISALMER | RAJASTHAN | 345001 | L4 | Rejected-Finance Not being lowest | |
| 5 | L5₹46.6 L+₹7.7 L (19.7%)Rejected-Finance | L5 | Rejected-Finance Not being lowest |
Tender Value
₹49.8 L
EMD Value
₹99,600
Closing Date
18 Feb 2023, 6:00 pmClosed
GE Army Jaisalmer
GE Army Jaisalmer - 345001
SPECIAL REPAIRS TO BLDG NO. NO. P-337 AND SEWAGE LINE AND MINOR WORKS IN CERTAIN AREA AT MIL STN JAISALMER
2023_MES_576628_1
8265/22-23/E8
Open Tender
Civil Works
Item Rate
180 days
Jaisalmer
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE Army Jaisalmer
₹99,600
Yes
16 Mar 2023
23 Jan 2023
20 Feb 2023
23 Jan 2023
18 Feb 2023
4 Feb 2023
Amount
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out soft/loose soil complete all as specified & directed by Engineer-in-charge.
Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation etc or for shaft, wells, cesspits, manholes, pier holes etc not exceeding 10 sqm on plan and getting out in any type of soil complete all as specified & directed by Engineer-in-charge.
Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, laying of cable/pipe etc or for shafts, wells, cesspits, manholes, pier holes etc not exceeding 10 Sqm on plan and getting out in soft/ disintegrated rock complete all as specified & directed by Engineer-in-Charge.
Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick in any type of soil all as specified & directed by Engineer-in-Charge.
Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick with soft/ disintegrated rock complete all as specified & directed by Engineer-in-Charge.
Removing excavated soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified & directed by Engineer-in-charge.
Removing excavated soft/ disintegrated rock to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed by the Engineer-in-Charge.
Demolition of stone slab & tiles of any description or thickness in floors, aprons etc laid bedded and pointed in any mortar all as specified & directed by Engineer-in-charge.
M&L Granite (of any type) tile 16 to 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including cutting and polishing laid on complete all as directed by Engr-in-charge.
M&L Granite (of any type) tile 16 to 20mm thick machine cut,in skirting/dado laid over cement screed bed and jointed with cement slurry, and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete all as directed by Engr-in-charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as directed by Engr-in-charge.
M&L for non skid ceramic coloured tiles of size 7 to 8mm thick (square/rectangular) area of each tiles exceeding 0.06 Sqm but not exceeding 0.11 Sqm, as in floors etc set & jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles laid over and including screed bed or bedding layer of mortar 15mm thick for laying floor finishes in CM 1:6 complete all as specified & directed by Engineer-in-charge.
S&F glazed ceramic coloured tiles of size 350 x 250mm x 7mm / 450mmx350mmx7mm thick on vertical surface such as skirting, dados, risers to steps etc set & jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles laid over and including 10mm thick backing coat in CM (1:4) complete all as specified and directed by Engineer-in-charge.
M&L light shade, vitrified tiles, 10mm thick (minimum), (square/ rectangular polished, area of each tiles not exceeding 0.36 sqm (including 600mmx600mm size), in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles laid over and including screed bed or bedding layer of mortar 15mm thick for laying floor finishes in CM (1:6) complete all as specified & directed by Engineer-in-charge.
M&L vitrified tiles of light shade, 10mm thick (minimum) (square/ rectangular) polished area of each tiles equal to or not exceeding 0.36 sqm (including 600mmx600mm size), in skirting/dado etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour tiles laid over and including 10mm thick backing coat in CM (1:4) complete all as specified and directed by Engineer-in-charge.
S&F in repair soap dish stanless steel to walls complete all as specified & directed by Engineer-in-charge.
S&F in repair 100 mm size cast iron floor trap, with CP grating including jointing to waste pipe fixed in cement conrete (1:2:4) type B-1 complete all as specified & directed by Engineer-in-charge.
S & F in repair bib tap 15 mm dia cast copper alongwith crutch or butterfly handle screwed down CP fancy type complete all as specified and directed by Engineer-in-charge.
S&F in repair 15mm dia pillar taps cast copper alloy with capstan head chromium plated screwed down high pressure with or without lettered Hot or Cold with long screwed shanks and fly nuts screwed for iron pipe complete all as specified & directed by Engineer-in-Charge.
S&F in repair tubular towel rail brass chromium plated 20mm dia D type 60cm long complete all as specified & directed by Engineer-in-Charge.
S&F in repairs vitreous china wash hand basin white 550x440mm of size incl cutting for and pinning in ends of brackets or erecting stand incl brackets PVC waste pipe 15mm PVC connection pipe and cuppling of suitable size complete all as specified & directed by Engineer-in-Charge.
S&F steel water tubing 15mm bore dia medium grade galvanised with and including necessary all fittings and fixtures complete fixed to walls, ceilings etc including taking down existing GI pipe of any description complete all as specified & directed by Engineer-in-charge.
S&F steel water tubing 20mm bore dia medium grade galvanised with and including necessary all fittings and fixtures complete fixed to walls, ceilings etc including taking down existing GI pipe of any description complete all as specified & directed by Engineer-in-charge.
S&F steel water tubing 40mm bore dia medium grade galvanised with and including necessary all fittings and fixtures complete fixed to walls, ceilings etc including taking down existing GI pipe of any description complete all as specified & directed by Engineer-in-charge.
S&F in repairs Vitreous china urinals with urinal spreader, Half stall (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60 mm long brass screws, pointing complete all as specified & directed by Engineer-in-Charge.
S & F in repair Vitreous china wash down water closet pan (Pedestal pattern), white (EWC)with necessary P/S Trap and fixed in repairs including jet spray and seat cover complete all as specified & directed by Engineer-in-Charge.
S&F in repair PVC low level white flushing cistern syphonic action type 10 ltrs capacity incl flush pipe 32 mm dia incl PVC connection 450 mm long and complete all as specified & directed by Engineer-in-Charge.
S&F in repair PVC connection 15mm size with PTMT nuts and polythene washers of 450mm length complete all as specified & directed by Engineer-in-Charge.
Taking down shutter of any description exe 1 sqm but N.exe 2 sqm and fixing after necessary welding of hinges to the frame. (Note fiixing/welding of hinges will be measured separately) complete all as specified & directed by Engineer-in-Charge.
Taking down chowkats or frames (without taking off shutters from the frames) area exceeding 1.5 Sqm but not exceeding 4 Sqm each complete all as specified & directed by Engineer-in-charge.
S&F solid PVC door frame of size 50x47 mm made out of 5 mm plain colour PVC sheet reinforced with M.S. Square tube suppling and fixing in opening as per specification and drawing complete all as specified & directed by Engineer-in-charge.
S & F for Plain, framed, panelled shutters 35 mm thick in second class hard wood (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats complete all as specified & directed by Engineer-in-Charge.
S & F figured glass pin head type 3mm thick ordinary quality and glazing with oil putty in square not exceeding 0.5 Sqm in each pane complete all as specified & directed by Engineer-in-Charge.
S & F 150 mm long Aluminium, anodised, barrel tower bolts of extruded section complete all as specified & directed by Engineer-in-Charge.
S & F 150 mm long Aluminium handles, cast type, anodised complete all as specified & directed by Engineer-in-Charge.
S&F medium weight Butt hinges 100 mm including necessary welding if required complete all as specified & directed by Engineer-in-Charge.
S&F 300mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy all as specified & directed by Engineer-in-charge.
S&F 30mm thick Factory made solid panel PVC door shutter (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing complete all as specified & directed by Engineer-in-Charge.
Taking down cement or cement lime plaster, any description on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water etc and removal of rubbish off the premises and leaving the work clear of any plastering complete all as specified & directed by Engineer-in-charge.
M&L for rendering 15 mm thick on stone masonry surfaces in cement mortar (1:4) including water proofing compound and finishing the surface even and smooth without using extra cement complete all as specified & directed by Engineer-in-charge. (Note: Supply only water proofing compound shall be measured and paid seperately).
M&L for rendering 15 mm thick, plaster in cement mortar (1:4) on stone masonry wall surfaces or surfaces other than fair faces of brick work or one side of lathing and finishing the surface even and fair without using extra cement all as specified & directed by Engineer-in-charge.
M&L for rendering 15 mm thick plaster in cement mortar (1:6) on fair faces of brick work or concrete surfaces of walls and finishing the surface even and smooth without using extra cement all as specified and directed by Engineer-in-charge.
M&L for rendering 15mm thick in cement mortar (1:4) in two layer (First coat 10 mm thick and second 5 mm thick) using water proofing compound @ 3% by weight of cement and finishing the surface even and fair without using extra cement all as specified & directed by Engineer-in-charge. (Note :- WPC will be measured and paid separetly).
M&L for rendering 5 mm thick plaster in cement mortar (1:4) on concrete surfaces of ceiling and finishing the surface even and smooth without using extra cement all as specified and directed by Engineer-in-charge.
M&L preparation of new plastered surfaces of any description and applying two coats of oil emulsion distemper over a coat of wall putty on wall and chalk whiting prepara-tory to distempering complete all as specified & directed by Engineer-in-charge.
M & L preparation of new plastered surfaces and applying three coat of white wash on ceiling complete all as specified & directed by Engineer-in-charge.
M&L for preparation of new plastered or unplastered surfaces of walls and apply two coats of cement base paint over a coat of putty for uniform smooth surface complete all as specified & directed by Engineer-in-charge.
M&L for preparing old plastered/ concrete surfaces ceiling by brooming down or steel wire brushing, scrapping down smoke soof, moulds, moss and efflorescent salts and trading oil and greasing spots and applying one coats of white wash all as specified & directed by Engineer-in-charge.
M&L for complete removal of the existing treatment on walls scrapping and washing including making good to the surfaces and applying one coat of alkali resistant primer and treating with two coat of distemper oil emulsion and incl 1mm thick wall care putty complete all as specified & directed by Engineer-in-charge.
M&L for preparation of old decorated plastered surfaces of walls and applying one coat of cement base paint complete all as specified & directed by Engineer-in-charge.
M&L for preparation of old painted steel surfaces of any description not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified & directed by Engineer-in-charge.
M&L for preparation of old painted wooden surfaces of any description not other wise described over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified & directed by Engineer-in-charge.
Hacking out old broken glass (any thickness, size quality or description) from wood /steel frame glazed with oil putty or fixed with beads and S&F plain sheet glass of 3 mm thick ordinary quality and glazing with oil putty and clips in squares not exceeding 0.50 Sqm in each pane complete all as specified & directed by Engineer-in-charge.
Welding in repairs exc 2.5cm but not exceeding 5cm in length (thickness of metal to be welded not exc 6mm ) including cleaning preparing the surface and holding the member in true position complete all as specified & directed by Engineer-in-charge.
Taking down old steel window/ventilators of any description not otherwise specified and in any position complete all as directed by Engr-in-charge.
S&F steel ventilators with top hung shutters fitted with box type hinges including MS peg stays, MS handle and glazing bars dovetailed or welded for receiving glass including painting with one shop coat of zinc chromate primer,and cutting holes in wall for fixing the window lugs in PCC 1:2:4 type B1 using 20mm graded aggregate and making good the disturbed surfaces in CM (1:3) and applying two coats existing wall finishes to match with existing colour complete all as specified and directed by Engineering –in-Charge. Note : The rates quoted are inclusive of making good all the disturbed surfaces to match with the adjoining surfaces and necessary scaffolding etc up to 4th floor.
Supply only integral water proofing compound sealed pack (ISI marked) complete all as specified & directed by Engineer-in-charge.
Demolition of cement concrete (reinforced) of any description and in any position not other wise specifically provided and removal unserviceable materials, debris and rubbish to a distance not exceeding 100m all as specified & directed by Engineer-in-charge.
Demolition of Brickwork or stone/ boulder masonry and built in cement mortar including all quoins arches, pillars etc but excluding ashlar facings, dressed stone work and precast concrete articles complete all as specified & directed by Engineer-in-charge.
M&L for squared rubble walling, Jodhpur type, brought upto courses, well bonded, bedded and solidly hearted, built in cement mortar (1:6) complete all as specified & directed by Engineer-in-charge.
M&L for squared rubble walling, Jodhpur type, brought upto courses, well bonded, bedded and solidly hearted, built in cement mortar (1:6) but except stone complete all as specified & directed by Engineer-in-charge. Note :- Serviceable stone obtained from demolition shall be used.
M&L sand stone slabs 5cm thick in sun-shades, chajjas, shelves, cills, landings, cover stones, templates, etc. n exc. 2m in length, punched dressed on face and along exposed edges, self faced on other side and set and pointed in lime mortar 1:2 or cement mortar 1:4. complete all as specified & directed by Engineer-in-charge.
M&L sand stone slabs 10cm thick in sun-shades, chajjas, shelves, cills, landings, cover stones, templates, etc. n exc. 2m in length, punched dressed on face and along exposed edges, self faced on other side and set and pointed in lime mortar 1:2 or cement mortar 1:4. complete all as specified & directed by Engineer-in-charge.
S&F in repair Single action spring hinge mild steel with steel wire springs stove enamelled black 100mm long including taking down of shutter and refixing in same opening, easing complete all as specified & directed by Engineer-in-charge.
Taking down all loose plaster and concrete if any in RCC columns, Chajjas, beams,slabs or any other type of RCC members,removing all loose ruts/scale from reinforcement etc by using wire brushes ,sand paper or any other chemicals, applying a coat appoxy coating on old reinforcement, tying IRC fabric of size 75x75mm of 3mm dia and binding with mild steel wire annealed with exsting reinforcement and applying cment slurry uniformaly to exposed surfaces and gunniting using CM 1:3 avg thickness of gunniting not less then 30mm and finishing the surfaces with 10mm thick rendering in CM 1:4 finished even and smooth with out using extra cement and removing the debris from the site, complete all as specified & directed by Engineer-in-charge.
S&F providing and fixing additional steel bar in various structural elements like column ,beams and Slab etc. including drilling ,bending and fixing the bars tying with preleft binding wires etc. complete Steel provided on the basis of 1% of volume of concrete. Anchoring reinforcement bar in exisiting RCC member in holes of minimum 10 d depth for 8 to 12 mm dia complete all as specified & directed by Engineer-in-charge.
S&F Flush cutting of RCC chajjas, fins with reinforcement up to 150 mm depth by norms of Rcc mechanical cutting machine complete all as specified & directed by Engineer-in-charge.
Dismantling of Ceiling Board of any description and any thickness including cover Fillets, Cornices, etc all as specified & directed by Engineer-in-charge.
S&F anodised aluminium snap grid frame work 605x605mm for false ceiling and hangers 6mm dia, GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40x3mm size 60mm long and expansion hold fastener 12.5mm dia 40mm long including Gypsum Board 12mm thick in ceiling fixed with screw as per manufacturers instructions complete all as specified and directed by Engineer-in-charge. Note :- (i) Main tee, cross tee shall be 35x25x1.5mm & 25x25x1.5mm respectively. Angle at end all along the walls shall be 40x25x2mm. (ii) Rate quoted by the contractor shall deemed to inclusive of frame work & ceiling board complete.
S&F in repair, 110mm bore PVC (SWR) single socketed in any length with rubber ring joints & fixed to walls complete all as specified and directed by Engineer-in-charge.
S&F in repair 110 mm bore PVC (SWR) bends/shoes any radius complete all as specified and directed by Engineer-in-charge.
S&F in repair 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed by Engineer-in-charge.
S&F in repair 75 mm bore PVC (SWR) bends/shoes any radius complete all as specified and directed by Engineer-in-charge.
S&F in repairs Cast iron nahani trap of 75 mm dia with grating including jointing to waste pipe fixed in cement concrete type B 1 (1:2:4) complete all as specified and directed by Engineer-in-charge.
S&F in repairs 75mm Cast iron soil, waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in floors complete all as specified and directed by Engineer-in-charge.
S&F 1000 litres capacity Three Layers White colour Rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I including taking down old existing PVC tank complete all as specified and directed by Engineer-in-charge.
M&L for 18/19mm thick prelaminated particle board exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work and including dismantling existing boarding of any description complete all as specified & directed by Engineer-in-Charge.
M&L for 2nd class hard wood fillets square, rectangular as in lippings fixed with nails of area exc 3Sqcm but n.exc 6sqcm complete all as specified & directed by Engineer-in-Charge.
S & F 40mm width of flaps (when open) continuous (piano) hinges, mild steel bright finish or electroganised fiwed to wooden or angke iron frame complete all as specified & directed by Engineer-in-Charge.
S&F 40mm dia, cupboard knobs fixed with nut, screw and washer of mild steel, bright finished complete all as specified & directed by Engineer-in-Charge.
S&F in repair 100 mm size hasp and staple, safety type, aluminium anodized with mild steel hinge pin including bolt to hinge plate and fixed with screws /fixedcomplete all as specified & directed by Engineer-in-Charge.
M&L for 35mm thick precast cement concrete louvers and jallies type C-0 (1:3:6) using 12.50mm graded aggregate (measured solid), including all mouldings but excluding frame, set in cement mortar 1:4 including dismantling Trellis work (Jafri) one way, including taking as under of battens in trellis (posts and rails measured separately) complete all as specified and directed by Engineer-in-charge.
M& L Providing type B1 (1:2:4) (20mm graded aggregate) precast ce- ment concrete in win- dow or door cills, lintels, bressumers, steps, quoin blocks (for use with masonry), string courses, copings. kneelers, apex stones, pier caps,columns, posts, boundary pillars, bed plates, pintle blocks, ancho-rage blocks, bonders (for stone wallin). corbels, brackets, etc. (of any section indicated), with plain fair faces, including chamfers, weatherings, throat- ing etc. and setting in mortar complete with joints to match and set in CM 1:4 all as specified & directed by Engineer-in-charge.
S&F solid PVC wall lining consisting of 5mm thick plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specification and drawing including taking down of existing wall panelling and similar work complete all as specified & directed by Engineer-in-charge.
S&F 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing complete all as specified & directed by Engineer-in-charge.
Dismantling wrought iron or mild steel work of any description specifically provided for gates, staircase railings, framed truss etc complete all as specified & directed by Engineer-in-Charge.
S&F Pre painted Galvalume aluminium zinc coating GI based corrugated steel sheet/ semi corrugated 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall fixed with self tapping screws and including dismantling existing roof sheeting complete all as specified & directed by Engineer-in-Charge.
S &F Rolled sections Fe-410- W(Gde- E-250) quality- Bas in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates complete all as specified & directed by Engineer-in-Charge.
Dismantling/Demolition of existing roof terracing of cement/brick concrete(un-reinforced) and existing water proofing treatment of any thickness in any position on top of roof of building, cleaning surface of roof with brush/mechanical brush and with water throughly to romove all dust/dirt and loose particles to expose bare concrete roof slab and romoval of rubbish/demolished material out side MD land complete all as specified & directed by Engineer-in-Charge. Note : Demolition should be done by chiselling.
M&L for PCC (1:2:4) Bo using 12.5 mm graded stone aggregate as in levelling padding course over RCC roof surface including rounded or chamferred on edges etc., with approved water proofing compound all as per manufacturer's instructuions on the roof surface to achieve requisite slope complete all as specified & directed by Engineer-in-Charge. (Note :- Supply only water proofing compound shall be measured & paid separately).
Supply only Liquid water proofing compound complete all as specified & directed by Engineer-in-Charge.
M&L for providing 3 mm thick APP modified memberane over RCC roof with the following specifiations :-
(a) Cleaning existing surface properly. (b) Apply oil bound bitumen primer @ 0.40 lit/Sqm manufactured by the same agency as that of APP with a density of 0.87 -0.89 Kg/Lit at 25 Degree Centigrade on the prepared dry roof surface. (c) Providing and Laying APP modified water proofing membrane reinforced with non wooven polyster matt with physical propertities as under :-(i) Membrane weight >3.6 Kg/Sqm .(ii) Net wooven polyster weight >160 gm/Sqm(iii) Softening point of membrane > 150o C(iv) Joint Tensile strength Longitudiual > 650 Sq Cm at 230o C & Transverse > 450/ Sq cm (v) Tear strength - Longitudual > 300 N & Transverse > 250 N Direction(vi) Elongation > 30 %(vii) Impermeability under water pressure > 3 Kg/Sq cm Note:- APP membrane shall be laid using butane torch by Torch application with minimum 10 cm side overlap and 15 cm end lap. The laying of membrane shall be got done through authorised applicator of manufacturer of membrane.(d) Over the membrance provide a finishing with solar reflective bituminous aluminium paint @ 0.1 Kg/Sqm as prescribed by manufacture of membrane
S&F in repair sinks made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm complete all as specified & directed by Engineer-in-Charge.
S&F in repairs stainless steel plate rack of size 31x30x10 inchs of approved make by Engr-in-charge fixed to wall including all fittings and fixtures complete all as specified & directed by Engineer-in-Charge.
S&F 30mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides covered with decorative face veneer with lipping/frame to match complete all as specified & directed by Engineer-in-charge.
S&F anodised aluminium door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified & directed by Engineer-in-Charge.
M&L double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed complete all as specified & directed by Engineer-in-Charge.
Demolition and breaking up drain pipes (Salt glazed ware, AC or reinforced concrete) of 150mm bore set in cement mortar including demolition of packing under and hauching against sides of pipes complete all as directed by Engineer-in-charge. (Note :- Excavation and earth work shall be measured and paid separately.
Demolition and breaking up drain pipes (Salt glazed ware, AC or reinforced concrete) of 200mm bore set in cement mortar including demolition of packing under and hauching against sides of pipes complete all as directed by Engineer-in-charge. (Note :- Excavation and earth work shall be measured and paid separately.
M&L for PCC (1:3:6) type C-2 (using 40mm graded stone aggregate) for concrete bed to drain pipes including packing under and haunching against the sides of pipe after they are laid and tested complete for 150mm bore pipe all as specified & directed by Engineer-in-charge.
M&L for PCC (1:3:6) type C-2 (using 40mm graded stone aggregate) for concrete bed to drain pipes including packing under and haunching against the sides of pipe after they are laid and tested complete for 200mm bore pipe all as specified & directed by Engineer-in-charge.
M&L for 150mm bore reinforced concrete pipes, class NP-2 (ISI marked) with collars, laid in trenches and jointed complete all as specified & directed by Engineer-in-charge.
M&L for 200mm bore reinforced concrete pipes, class NP-2 (ISI marked) with collars, laid in trenches and jointed complete all as specified & directed by Engineer-in-charge.
M&L for rendering 10 mm thick plaster in cement mortar (1:6) on fair faces of brick work or concrete surfaces of walls and finishing the surface even and smooth without using extra cement all as specified and directed by Engineer-in-charge.
S&F in repair, 125mm/110mm dia PVC (SWR) gully trap, setting & jointing with solvent cement complete all as specified & directed by Engineer-in-charge.
Cleaning of choked sewage line of 100 mm bore of pipe including drains by rodding and well flushing with water, taking out waste materials any quantity and depositing where directed including covering the same with at least 30cm thick layer of soil complete all as specified & directed by Engineer-in-charge.
---- ditto --- all as per item No. 107.00 above but 150mm bore sewage line
---- ditto --- all as per item No. 107.00 above but 200mm bore sewage line
---- ditto --- all as per item No. 107.00 above but 300-600 mm bore sewage line
Cleaning of manholes not exceeding 1.5m deep by means of removing the silt, sludge, etc & bailing out foul water complete manually or mechanically and covering of the same with soil, not less than 30cm thick layer and making good all excavated site as required complete all as specified & directed by Engineer-in-charge.
Cleaning of manholes exceeding 1.5m but not exceeding 3m depth by means of removing the silt, sludge, etc & bailing out water complete manually or mechanically and covering of the same with soil, not less than 30cm thick layer and making good all excavated site as required complete all as specified & directed by Engineer-in-charge.
Cleaning of floor trap, gully trap in any size by means of removing the silt, sludge, etc & bailing out water complete manually or mechanically and removing the same out side MD land complete and making good all as directed by Engineer-in-Charge.
Blockage of WC/EWC in any type floor by means of removing the silt, sludge, etc & bailing out water complete manually or mechanically and removing the same out side MD land complete and making good all as directed by Engineer-in-Charge.
Blockage of urinal in any type floor by means of removing the silt, sludge, etc & bailing out water complete manually or mechanically and removing the same out side MD land complete and making good all as directed by Engineer-in-Charge.
Blockage of WHB in any type floor by means of removing the silt, sludge, etc & bailing out water complete manually or mechanically and removing the same out side MD land complete and making good all as directed by Engineer-in-Charge.
M&L for preparation of new plastered or unplastered surfaces of walls and apply two coats of cement base paint over a coat of primer complete all as specified & directed by Engineer-in-charge.
S&F for insulated fabric cover/ jacket for water tank built for hot and cold weather for 1000 ltrs tank capacity etc complete all as specified and directed by Engineer-in-charge.
S&F for insulated fabric cover/ jacket for water tank built for hot and cold weather for 500 ltrs tank capacity etc complete all as specified and directed by Engineer-in-charge.
Taking down carefully surface aluminium or copper point wiring with PVC casing-caping (light, fan, socket, bell or power) including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc and making good disturbed surfaces complete all as specified & directed by Engineer-in-Charge.
Taking down the existing unserviceable main switch / cut out / DBs of any type / capacity / description as existing at site including MCBs any type and capacity making good the disturbed surfaces to match with the existing finishes complete all as specified & directed by Engineer-in-Charge.
Taking down the existing unservicable sub main wiring of any type / description as existing at site including making good the disturbed surfaces to match with the existing finishes complete all as specified & directed by Engineer-in-Charge.
Taking down old unsv building security light fittings complete all as specified & directed by Engineer-in-Charge.
Taking down old unsv /rusted GI braket suitable for security light fittings complete all as specified & directed by Engineer-in-Charge.
Taking down of old unsv tubelight fitting /surface panel light / flood light of any description light fitting any type any watt complete all as specified & directed by Engineer-in-Charge.
Taking out carefully copper/GI earthing complete including GI pipe with Cu/GI strip and removing materials for taking credit and making good disturbed surface complete all as specified & directed by Engineer-in-Charge.
M&L Point wiring used approved colour coding as per IS (Red, Black and Green) for single phase circuits), with multi-stranded copper conductor 1.5 sqmm nominal cross -sectional area, single core, PVC insulated and unsheated FRLS cable 1100 volts grade, ISI 694 marked with valid CML No. in and including medium grade, PVC concealed conduit MMS, ISI marked of dia not less than 20 mm and conduit accessories conceled in wall/roof/floor etc, ISI marked with valid CML No. (IS-9537 - 1983 for condits and IS : 3419 - 1976 for conduit accessories) with terminated to new pressed flush metal boxes readily available cover with outer plates inner plates et, suitable for mounting modular type switches, socket fan regulator etc PVC insulated multistanded copper conductor 1.5 Sqmm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified & directed by Engineer-in-Charge for the following :- Note : Modular switch and socket shall be measured and paid separately.
a) One light point controlled by one switch
b) One ceiling/exhaust fan point controlled by one switch
(c) One socket outlet 6 amp controlled by one switch on the same board with other switches.
(d) One 2/3 pin socket outlet 5Amps on independent board.
All as per item No 127.00 above but pint wiring with 4.00 sqmm single core multi stranded copper conductor PVC insulated and unsheathed (FRLS) cable 1100 volts grade and 4.00 Sqmm PVC insulated and unsheated (FRLS) cable 1100 volts grade with multi stranded copper conductor as earth wire for 15/16 Amps multi porpose socket combination point on independent board. Note : Modular switch and socket shall be measured and paid separately.
S&F modular switch one way 6A, 1 module complete all as specified & directed by Engineer-in-Charge.
S&F modular socket 6A-2/3 pin combined 2 module complete all as specified & directed by Engineer-in-Charge.
S&F modular switch socket combined 6A/16A , 6 pin, 3 module complete all as specified & directed by Engineer-in-Charge.
S&F step type modular fan regulator 120W -2 module ISI Marked with valid CML No complete all as specified & directed by Engineer-in-Charge.
S&F Ceiling rose, three terminals PVC/polycorbonate, isolated body complete all as specified & directed by Engineer-in-Charge.
S&F vertical DBs TPN 4 way 415 V double door powder coated, CRCA steel sheet constructed as per IS : 8623, degree of protection IP 43 - IK 09 with metal door, recess mounted, having insulated 250 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required,suitable for TP/FP MCCB as incomer with MCCB 160A , and with SP/TP MCCB's as outgoing MCCB FP 160A , 25 KA complete all as specified & directed by Engineer-in-Charge.
S & F for MCB DB SPN 12 way double door IP 43 complete prewired including Bus Bar etc suitable for operation on 240 volt 50 Hz AC supply including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified & directed by Engineer-in-Charge.
Supply and fixing MCB's single pole and neutral 32 Amps, 240 Volts,10 KA rapturing capacity 'C' curve. complete all as specified & directed by Engineer-in-Charge.
Supply and fixing MCB's single pole 10 Amps to 32 Amps, 240 Volts,10 KA rapturing capacity 'C' curve complete all as specified & directed by Engineer-in-Charge.
M & L for submain wiring with approved colour code/as per IS (Red,black & green for single phase)concealed conduit circuit with two single core PVC insulated cable with multistranded copper conductor of nominal cross sectional area of 10.00 Sqmm (FRLS) in conduit including one run of PVC insulated multistranded copper conductor nominal cross sectinal area of 10.00 Sqmm (FRLS) of continous earth wire green in colour complete all as specified & directed by Engineer-in-Charge. (Note :- Two runsof 10.00 Sqmm cable & one run of 10.00 Sqmm cable shall be paid as one unit length)
M & L for submain wiring with approved colour code/as per IS (Red,black & green for single phase)concealed conduit circuit with two single core PVC insulated cable with multistranded copper conductor of nominal cross sectional area of 6.00 Sqmm (FRLS) in conduit including one run of PVC insulated multistranded copper conductor nominal cross sectinal area of 6.00 Sqmm (FRLS) of continous earth wire green in colour complete all as specified & directed by Engineer-in-Charge. (Note :- Two runsof 6.00 Sqmm cable & one run of 6.00 Sqmm cable shall be paid as one unit length)
S&F in repair of Gyser/AC Box having 20 Amp MCB SP as incomer complete all as specified including taking down existing once complete all as specified & directed by Engineer-in-Charge.
Supply and fixing of building security light fitting LED 35 Watt IP 66 IK 07 pressure dia cast aluminium housing with high efficient LED as lihjting souce and PC cover having TOP opening sepreate drive compartment etc and connecting complete all as specified & directed by Engineer-in-Charge.
S&F bracket of GI pipe light grade of 40mm bore dia, 1.2 meter in length, MS clamps made of FI 40 mm x 6mm incl nuts, bolts & washers including two coats of synthetic enamel paint over a coat of zink chrome primer complete all as specified & directed by Engineer-in-charge.
Supply and fixing of LED box type Integrated Batten, 40 watt having Aluminum Extruded housing in white powder coated finish with high translucent PC Cover, Elegant Design, IP 20 Protection. Size of fitting shall 1200 mm x 40 mmx 63 mm luminous output of the fitting shall not less then 4000 lm, CCT 5700 – 6500K, Surge Protector 4 KV, PF>= 0.95 , Separate detachable type Electronic constant current drivers for easy replacement and maintenance, THD < 10%, Necessary mounting arrangements. The Manufacturer of the fixture shall have in house NABL Accredited Lab and must produce certificate of the same along with LM-79 / LM80 / Test Report. Make PHILIPS CAT PART NO. BN100C LED40S-6500 PSU L120 GR S4 or equivalent in Appx 'C' list of makes.
Supply and fixing of recessed/ceiling mounted down lighter with CRCA housing with high bright LED,idealy suited for low ceiling areas Brilliance 36watt LED, size 2ft x 2ft The product features color tuning from 3000 K to 6500 K, necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting with white color flexible pipe complete all as specified & directed by Engineer-in-charge.
S & F in repair of LED tube light fitting 10 watt tube LED Neutral white in colour, 600 mm in length wall mounted LED batten,extruded aluminium heat shink provided for efficient heat dissipation & integrated electronic driver,optic diffused type ENDURA LINER NEO including all electric connection with whilte flexible cord 1.50 Sqmm 3 core as required complete all as specified & directed by Engineer-in-charge.
Taking down ceiling fan/exhaust fan of any sweep, dismanting blade and including preparation, filling cavity applying one coat of synthetic enamel paint by spraying with machine, re-assembling the fan body to fan and re-fixing in its original position or any other position as directed complete all as specified & directed by Engineer-in-charge. Note :- Rate quoted by the contractor shall deemed to inclusive of replacing of quarter pin, nut bolt with check nut, rubber real etc.
M & L bore earthing not less than 250 mm dia 16 feet deep filled with black soil up to 7 feet from bottom complete with galvanized iron pipe 40 mm bore medium grade 3 meter long tapers at bottom & provided 12 mm holes (staggered) at 75 mm centre to centre up to 2.5 meter of length from bottom , burried directly in ground filled with 45 cm alternate layer of chemical magnisium sulphate, charcoal & salt up to ground levl connected to galvanized iron strip 25x3 mm as earthing lead up to 7.5 mtr by means of bolt and nut, check nuts and washer of galvanized iron or steel including brazing work and 40mm dia light grade pipe for earth lead protection and testing complete all as specified & directed by Engineer-in-charge.
NOTE FOR ITEM No. 147.00 [i]. Excavation & earth work in any type of soil including removing of surplus material upto 100M [ii]. PCC (1:3:6) type C1 using 20mm graded stone aggregate in pit & 40mm thick precast RCC (1:2:4) type B1 cover 50x50 cm with 8mm round bar @ 15 cm C/C both ways. [iii]. Main earthing strip from earth electrode to test point upto 7.5 mtr. [iv]. Funnel with watering pipe [GI pipe] 20mm bore [ISI marked] medium grade & copper lugs and charcoal & salt as reqd. [v]. GI protection pipe of size 40 mm bore light grade 7.5m.
S&F steel water tubing 40 mm bore, 'light grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in trench on pole for protection of cable etc and including taking down existing pipe of any description complete all as specified & directed by Engineer-in-charge.
M&L for Earth continuity strip fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to DBs or any other indicated situation for loop earthing with galavanised iron strip of 25X3 mm size complete all as specified & directed by Engineer-in-charge.
Supply, laying and testing LT XLPE insulated, armoured heavy duty, electric cable, with aluminium conductor, 1100 volts grade, cross-sectional area 50 Sqmm 3½ Core and including taking down existing unserviceable cable complete all as specified & directed by Engineer-in-charge.
M&L for sand cushioning to under ground cable using tibba sand and gently punning to cushioning to cable complete all as directed by Engineer-in-Charge. (Note :- Punned thickness of sand cushioning shall only measured for the purpose of payment).
Supply & laying 40 to 50mm thick roughly hammer dressed Jodhpur stone patti cable cover 25cm to 30cm wide and not exc 60cm long each laid dry abutting with each other with maximum gap between adjacent slabs n. exc 10mm complete all as specified & directed by Engineer-in-charge.
S&F steel water tubing 80 mm bore, 'light grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in trench on pole for protection of cable etc complete all as specified & directed by Engineer-in-charge.
M& road cutting in trenches for laying cable protection pipe including making good the surface with top 200mm thick shall filled with PCC (1:2:4) type B-1 (using 20mm graded stone aggregate) complete all as specified & directed by Engineer-in-charge.
S&F gun metel, globe or gate valve with iron wheel head screwed both ends for iron pipe and fixed for the size 20 mm bore with fittings and accessories. ISI marked and as per IS 14846 including taking down existing gate valve of any description complete all as specified & directed by Engineer-in-Charge
S&F gun metel, globe or gate valve with iron wheel head screwed both ends for iron pipe and fixed for the size 40 mm bore with fittings and accessories. ISI marked and as per IS 14846 including taking down existing gate valve of any description complete all as specified & directed by Engineer-in-Charge
Cutting the existing PCC/bituminous road of any description to a size not exc. 0.5m wide x 0.5m deep for crossing of pipe including refilling, ramming and making top 100mm thick surface good with plain cement concrete 1:3:6 type C1 (using 20mm graded stone aggregate) complete all as specified & directed by Engineer-in-charge.
S K TRADER
AMBEY MAA CONSTRUCTION COMPANY
BHAGWATI CONSTRUCTION
Vinay Traders
M/s Shri Inder Construction Company
deepaktraders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .