Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹18.9 CrAdmitted-Finance | +9.73% | ₹18.9 Cr | L1 | Admitted-Finance |
Tender Value
₹17 Cr
EMD Value
₹34 L
Closing Date
24 Jan 2023, 6:00 pmClosed
MD, RPIDC Ltd. Jaipur
MD, RPIDC Ltd., 756, Police Head Quarter, Lal kothi, Jaipur (Raj)
Construction of Regional Forensic Science Laboratory building at Bharatpur
2023_RPHCC_313236_2
NIT No 21 of 2022-23MD, RPIDCL, Jaipur
Open Tender
Civil Works
545 days
Bharatpur
Please refer Tender documents.
5 documents required · 5 mandatory
₹11,800
Yes
MD. RPIDC Ltd. THROUGH NEFT/RTGS/IMPS
₹34 L
15 Feb 2023
16 Jan 2023
25 Jan 2023
16 Jan 2023
24 Jan 2023
16 Jan 2023
Amount
Providing Hoisting and Fixing at floor five level Pre cast RCC Chattri In 1:2:4 (1 Cement:2 Coarse Sand:4 Coarse graded stone aggrgate) reinforced with Mild Steel) of Rajasthani Traditional Architecture style (Jaipur Practice) having precast base of size not more than 900mmX900mm having decorative kangura design all around, over this Octogonal pre cast arches each on all four sides supported on precast pillers at all corners, a pre-cast Chajja and dome above this structure with dia not more than 900mm and over the top of this complete assembley a decorative kalasha, the overall height of this precast chattri shall be not more than 3 meter(From bottom of the base to top of the dome excluding the height of decorative Kalasha). The chattri shall have patterns all around in the shapes of kangooras, leveas, grooves etc as per jaipur practice complete as per approved design and complete as per direction of engineer in charge including fixing of joints and rendering with cement mortar 1:3 (1Cement :3 Coarse Sand.) all complete etc.
Providing Hoisting and Fixing at floor four level Pre cast RCC Mandap Chattri In 1:2:4 (1 Cement:2 Coarse Sand:4 Coarse graded stone aggrgate) reinforced with Mild Steel) of Rajasthani Traditional Architecture style (Jaipur Practice) having precast base of size not more than 6000mmX1000mm having decorative kangura design all around, over this four pre cast arches each on all four sides supported on precast Twelve pillers at all corners, a pre-cast Chajja and dome above this structure with dia not more than 1200mm and Mandap Chhatri at middle of size not more than 3200mmX1200mm over the top of this complete assembley five decorative kalasha, the overall height of this precast chattri shall be not more than 4200 mm (From bottom of the base to top of the dome excluding the height of decorative Kalasha). The chattri shall have patterns all around in the shapes of kangooras, leveas, grooves etc as per jaipur practice complete as per approved design , 3D view and complete as per direction of engineer in charge including fixing of joints and rendering with cement mortar 1:3 (1Cement :3 Coarse Sand.) all compete etc.
Providing Hoisting and Fixing at all floor level below chajja Pre cast RCC Cornice In 1:2:4 (1 Cement:2 Coarse Sand:4 Coarse graded stone aggrgate) reinforced with Mild Steel) of Rajasthani Traditional Architecture style (Jaipur Practice) having size not more than 500mmX500mm and 50mm thick having decorative kangura design all around, The cornice shall have patterns all around in the shapes of kangooras, leveas, grooves etc as per jaipur practice complete as per approved design, 3D view and complete as per direction of engineer in charge including fixing on position and joints and rendering with cement mortar 1:3 (1Cement :3 fine Sand.) all complete etc.
Providing and fixing Automatic door Opening & Closer Senser with all fitting of Dorma make ES200 Easy (Heavy Use ) 4.15 M long comprising of: track profile 4150 mm, Motor with SMPS,Light barrier-1 Pair, Five position program switch, glass clamping rail-2 nos, Floor guide for glass door - 2 nos, Automatic fixed manet- 14 pieces, etc all complete as per specification and direction of Engineer-in-charge.
Providing and fixing 12 mm thick frameless toughened glass for partition of approved brand and manufacture, including providing and fixing it on top & bottom and making necessary holes etc., all complete as per direction of Engineer-incharge (all ss fixing accesories included).
Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-incharge (Door handle, lock and stopper and other required fittings should be of make Hettich or equivalent approved by EIC are inclusive in the cost.)
(d) System controller to control Operation Main Electric pumps, Diesel pump, jockey pump in sequence as per specs. Consisting of relays, timers, sensors, annuciation window for fault indication.
Supply & Fixing of Fire Man's Axe with heavy Insulated rubber tested up to 20 KV and confirming to IS ;926
SITC of Response Indicator for addressable type detectors as required
Supply and installation with bracket / supports water based fire extinguisher ( IS : 15683 ) suitable for A class of fires with easy snap safety seal,state of art presure gauge ,controllable discharge mechanism, EPDM rubber hose pipe as required. Capacity - 9 Ltrs.
SITC of RO water system with Filtration stage = Particilate filter-Membrane life enhancer filter - sediment filter-Pre carbon filter - RO Membrance filter - Post carbon filter, Input power rating - 230 V AC, 50 HZ, Percentage of Rejection TDS - 90% or better having following features (a) Double purification by RO with ESS or latest technology with TDS indicator. (b) Spin welded RO Membrance Housing to prevent tempering. (C) Push fit components for leak proof performance (d) Fully automatic operation with auto start and auto off. (e) SS/ABS construction for corrosion free lifespan. (f) Equally suitable for water from all bore wells, overhead storage tanks, water tankers and even municipal taps. (g) RO Membrane Flushing - Auto Flush @ Every Start, Every Stop and every One Hour of working for one minute. Complete in all respect with following capacity.
Purification capacity - 50 LPH, Duty Cycle 270-500 liters/day
(d) Car : car should be with M S platform withbracings of adquate size and to sustain the impactload cabin plus passengers with safety factor of firefor steel withAnti skid PVC flooring and side panelsshould be of Stainless steel with hair line finish ofsheet of grade 304 duty with S.S. handrails . Carceiling shall be steel finish with aestheticappearances with LED ceiling lights .The size of thecar shall be taken as per available lift well size andrelevant BIS code of lifts . Car panel will also be of SS 304 grade finished with emergency stop device ,alarm,mechanical door safety device,full length infra-red curtain in car door , facility ofauto/attended mode. All car panel buttons and allfloor switches must be with brail language as per liftact. Agency shall also provide & install one No. 2 Mp, lR, lP based ceiling mounted Dome Camerain thecar complete with connecting cables & accessories(To be connected with existing CCW system in theBuilding) .The inspection unit shall be provided atthe top of the car.
(e)tanding Doors : All landing door shall be fullyautomatic centre opening/telescopicmade of hairline finish stainless steel grade 304 with key holesand infrared curtainswith unlocking facility fromoutside.
(f) Emergency light: Appropriate rechargeablebattery operated LED emergency light in the car andalong with alarm switch shall be provided.(C) ARD: Automatic rescue Device (ARD) shall beprovided according to passenger capacity with SMF batteries of approved brands as per BSR.h) Audio-Visual lndication : Audio visual indicationin the lift car , showing over loading such thatdoors kept open till excess load is removed.(i) Scrolling lndicators: Digital scrolling indicatorsystem for up-down arrow with floor positionindicator shall be provided inside the car and at allstops/floors.(j) Buffers: Spring buffers/pU Buffers shall beprovided.(k) Car Fan : ENERGY EFFICIENT Car fanlblower withautomatic sleep timer shall be provided.(l) Voice Annunciator: Voice annunciator withsuitable music shall be provided in lift car.
(m) Self diagnostics system for operational andsafety parameters shall be provided in control panel(n) Mechanical/Electronic over speed governor,door key holes in the floor doors, fireman switchshall be provided .(o) Lift machine hoisting arrangement in the liftmachine room , counter balance to promotesmooth and economic operation complete withsteel guide rails for the car & counter weight ,Trap , Lifting hooks as required and monkeyladders for lift pit should be provided by the agencyalong with all other steel structure works,foundations for the machine etc as required
(p) Permanent wiring in lift machine room and inlift well with providing and fixing of electricaldistiribution board complete with Sp & Tp MCB,s,proper numbers of light points, with LED fixtures ,exhaust fan , 2 nos copper plate /chemical earthingwith 8 SWG copper earth wire and plug points shallbe provided by the agency . ( power supply of 3phase 440 V shall be made available by departmentin lift machine room .)
(qlAll civil work related to installation of lift likefinishing, cleaning and levelling of lift pit , whitewash of lift well and in machine room shall be doneby the lift erecting agency without any extra cost.
(r) Granite or marble cladding around all landingdoor openings shall be in the scope of liftinstallation agency and additional payment shall bemade according to the actual measurement /schedule by the department to the lift agency.s) Agency has to provide all working drawings anddocuments to comply latest BIS specifications andmake proper liasion services for obtaining allnecessary permissions.
13 passengerslSS4 Kg , 3 stops, rated speedadjustable up to 1.0 mtr /sec with 2 year
Supply Installation, testi.n g & Com. missioning of EPABX System consist, No. of Extension, No. of Junction No. of Expandable e ports, Operator console. Current on max. load with ISDN , complete of approved make and labor as required as per , Specifications:
EPABX System consists of 48Nos Extensions. 8nos Junctions, & up to 96Nos Expandable e ports with one Operator Console. 2amp .max. Current.
Supplying & fixing Float cum boost charges for EPABX System of approved make with all necessary material as required as per Specification.10 Amp, 48 V Float cum boost charger.
Supplying fixing of Essential additional Accessories to EPABX System of approved make with all necessary material as required as per Specification.
EPABX E-l Card
R-2 TWT Card
Hot Standby Card
EPSBX- Operator console
EPABX System Digital Phone with 2 line display (32, Characters) with 8 programmable keys.
EPABX System line Card to extend the number of line by 8.
EPABX System junction Card to extend the number of Index by 4.
EPABX System junction Card to extend the number of junction by 8.
EPABX System Digital line Card 8 line.
4 Push Button CLI Phone.
SITC of IP Based 4MP IR Bullet Camera: 1/2.8"ProgressiveCMOS, ICR, 0lux with IR, 1920x1080:25fps(P)/30fps(N),4mm/ 6mm lens (As persite requirement), H.264 / MJPEG, dual-stream, 120dB WDR or better, 3D DNR, BLC, IR: up to 30m, Motion detection, Dynamic analysis, Alarm should be trigger on (Tampering alarm, Network disconnect, IP address conflict, Storage exception), security feature such as (password protection, privacy mask, watermark, IP address filtering, anonymous access), Open Standard to support ONVIF (PROFILE S, PROFILE G), PSIA and CGI Protocol, Metal Housing, Vandal-proof housing IP67, DC 12V & PoE. Complete with junction box for cable management. Make:- Honeywell,Hikvision,CP-Plus,Dahua
Supply Installation Testing and Commissioning of of 32Ch NVR with 08 Sata with 256 Mbps incoming Bandwidth, dual Operating System, ANR technology for storage reliability, ONVIF based third party cameras should be connected, 4K output, Up to H.265 Compression Support, up to 8MP Cameras supported for live view and playback, able to decode 08 cameras @ 1080p, 24 TB Surveillance HDD ( each of 6 TB), 08 Sata slots to support up to 6TB each, two-way audio, dual 10/100/1000mbps RJ45 Network, USB 3.0 port, Alarm In/Out (16/4), Operating Conditions: ‐10 °C – 50 °C or better, dual power supply, 19" rack mounted chassis. The NVR should be of the same make of cameras for the smooth working of the system.Make:- Honeywell,Hikvision,CP-Plus,Dahua
SITC of Managed 24 port Layer-2 POE (370 watt) Intelligent Ethernet Switch providing 24 x 10/100/1000 Fast Ethernet ports and with min 4 SFP Giga Ports (provision for Fiber Giga connectivity) with provision of Switches with related LAN Base Software . ( FOR CCTV) make:-CISCO,JUNIPER,D-LINK,DIGISOL
Supply and fixing of PVC conduit pipe of 25mm dia Standard make with ISI Mark with allrequired fitting and laying accessories . It alsoinclude cutting wall/surface and repair it after fixingthe conduit pipe for concealed wiring work where
Supply, installation and complete indoor wiring of 19inch covered Rack of size 22U The rack shall be complete with all fittings for housing SDH equipments, Primary MUXES, DDF, MDF using crone modules and other equipments like runway ladders etc completely wired and equipped with integrated protection modules for all channels with All Others Req. Accessories. It should be possible to lock all the equipments with only order wire telephone remaining outside the rack. Makes:-Netrack,com-rack,d-link,
supply, installation, testing and commissioning of high resolution large video display unit 102 CM (55") full HD 1920 x 1080, monitor control on screen display, Programmable with remote, S-Video, ideo/Composite video, PC analog input (RGB, D-sub) viewing angle of 170 degree x 170 degree, dynamic contrast ration of 15000:1 for use of 24*7 days with Wall & Table mount make sony/Samsung/Philips/Panasonic/ LG or equivalent
SITC 4 TB HDD (3.5")SURVEILLANCE (SEGATE,WD)
Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected by PVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack & ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Tendernotice_1.pdf
PDF • 0.68 MB
Tendernotice_2.pdf
PDF • 0.12 MB
Tendernotice_3.pdf
PDF • 0.03 MB
Tendernotice_4.pdf
PDF • 0.72 MB
Tendernotice_5.pdf
PDF • 0.38 MB
Tendernotice_6.pdf
PDF • 1.57 MB
Front_Page_.pdf
Additional Documents • 0.23 MB
ListOfApprovedMakes.pdf
Additional Documents • 0.72 MB
Special-Condition-1.pdf
Additional Documents • 0.47 MB
Special-condition-II.pdf
Additional Documents • 0.58 MB
Technical-Evalution-sheet.xls
Tender Documents • 0.03 MB
BOQ_558093.xls
BOQ • 1.10 MB
NIT21withCorriegendum.pdf
Tender Documents • 0.65 MB
Final-SBD-FSL.pdf
Tender Documents • 1.43 MB
Download all tender documents and submit your bid