Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.5 CrAccepted-Finance | ₹1.5 Cr | L1 | Accepted-Finance Financial bid evaluated as per tender terms and conditions. The bidder has provided one lakh discount on basic amount |
| 2 | L2₹1.7 Cr+₹17.2 L (11.2%)Accepted-Finance SCO NO 05 VILLAGE MAULI SECTOR 80 MOHALI PUNJAB 140308 | S A S NAGAR | PUNJAB | 140308 | ₹1.7 Cr+₹17.2 L (11.2%) | L2 | Accepted-Finance Financial bid evaluated as per tender terms and conditions |
| 3 | L3₹1.8 Cr+₹24.2 L (15.8%)Accepted-Finance 15 32 NEAR FLYOVER ROAD NO 32 PUNJABI BAGH EAST WEST DELHI DELHI 110026 | DELHI | WEST DELHI | DELHI | 110026 | ₹1.8 Cr+₹24.2 L (15.8%) | L3 | Accepted-Finance Financial bid evaluated as per tender terms and conditions |
| 4 | NA₹0.10Rejected-Finance ASHOK MARG LUCKNOW UTTAR PRDESH 226001 | LUCKNOW | UTTAR PRADESH | 226001 | ₹0.10 | NA | Rejected-Finance Financial bid not submitted as per tender terms and conditions. Therefore the bid submitted is not considered for further evaluation |
| 5 | Rejected-Technical G200 2ND FLOOR SECTOR 63 NOIDA 201307 PH 0120 4316608 9210000201 | - | - | Rejected-Technical Not comply as per tender terms and conditions |
Tender Value
Refer Docs
EMD Value
₹3.3 L
Closing Date
4 Jun 2020, 4:00 pmClosed
MANAGER - ADMIN
KWOWLEDGE CITY SECTOR 81 MOHALI
Annual operation and maintenance contract of Electrical, civil etc.
2020_NABI_559171_1
NABI/7(100)/2017-WORKS
Open Tender
Miscellaneous Works
Item Rate
365 days
NABI CAMPUS
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
Yes
NABI
₹3.3 L
Yes
27 Jul 2020
14 May 2020
5 Jun 2020
14 May 2020
4 Jun 2020
14 May 2020
Annual Operation & Maintenance cost with Manpower deployment at NABI campus for existing Electrical, Civil, Fire fighting, Public Health and allied services as per the scope of work defined in Schedule-A and referring Annexure-3 of Volume-1 of tender document
Annual Operation & Maintenance cost with Manpower deployment at CIAB campus for existing Electrical, Civil, Fire fighting, Public Health and allied services as per the scope of work defined in Schedule-A and referring Annexure-3A of Volume-1 of tender document
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. (Upto 35 sq. mm)
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. (Above 35 sq. mm and upto 95 sq. mm)
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. (Above 95 sq. mm and upto 185 sq. mm)
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. (Above 185 sq. mm and upto 400 sq. mm)
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing masonry open duct as required. (Upto 35 sq. mm)
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing masonry open duct as required. (Above 35 sq. mm and upto 95 sq. mm)
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing masonry open duct as required. (Above 95 sq. mm and upto 185 sq. mm)
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing masonry open duct as required. (Above 185 sq. mm and upto 400 sq. mm)
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on cable tray as required. (Upto 35 sq. mm (clamped with 1mm thick saddle))
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on cable tray as required. (Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp))
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on cable tray as required. (Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp))
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on cable tray as required. (Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp))
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1kV grade as required. (3 X 10 sq. mm (22mm))
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1kV grade as required. (3 X 16 sq. mm (25 mm))
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1kV grade as required. (3 X 25 sq. mm (25 mm))
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1kV grade as required. (3 X 35 sq. mm (28mm))
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1kV grade as required. (4 X 10 sq. mm (25 mm))
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1kV grade as required. (4 X 16 sq. mm (28mm))
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1kV grade as required. (4 X 25 sq. mm (28mm))
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1kV grade as required. (4 X 35 sq. mm (32mm))
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1kV grade as required. (3.5 X 50 sq. mm (35 mm))
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1kV grade as required. (3½ X 70 sq. mm (38mm))
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1kV grade as required. (3½ X 95 sq. mm (45 mm))
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1kV grade as required. (3½ X 120 sq. mm (45 mm))
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1kV grade as required. (3½ X 150 sq. mm (50 mm))
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1kV grade as required. (3½ X 185 sq. mm (57mm))
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1kV grade as required. (3½ X 240 sq. mm (62mm))
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1kV grade as required. (3½ X 300 sq. mm (70 mm))
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1kV grade as required. (3½ X 400 sq. mm (82mm))
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. (3 X 16 sq. mm (25 mm))
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. (3 X 25 sq. mm (25 mm))
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. (3 X 35 sq. mm (28mm))
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. (4 X 16 sq. mm (28mm))
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. (4 X 25 sq. mm (28mm))
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. (4 X 35 sq. mm (32mm))
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. (3.5 X 50 sq. mm (35 mm))
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. (3½ X 70 sq. mm (38mm))
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. (3½ X 95 sq. mm (45 mm))
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. (3½ X 120 sq. mm (45 mm))
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. (3½ X 150 sq. mm (50 mm))
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. (3½ X 185 sq. mm (57mm))
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. (3½ X 240 sq. mm (62mm))
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. (3½ X 300 sq. mm (70 mm))
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. (3½ X 400 sq. mm (82mm))
Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 kV grade as required. (240 sq. mm)
Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 kV grade as required. (300 sq. mm)
Supplying and making straight through cable jointing with heat shrinkable jointing kit complete with all accessories including ferrules suitable for following size of 3 core, XLPE aluminium conductor cable of 11 kV grade as required. (240 sq. mm)
Supplying and making straight through cable jointing with heat shrinkable jointing kit complete with all accessories including ferrules suitable for following size of 3 core, XLPE aluminium conductor cable of 11 kV grade as required. (300 sq. mm)
Dismantling of pole/ street light standard/ strut embedded in cement concrete foundation etc. as required.
Excavation for cable trenches in soft soil, depth upto 1.2 m including dressing of sides lift upto 1.5 m, including getting out the excavated soil, refilling with sand and or good soil after laying of cable/ pipe etc. in layers of 20 cm, ramming, watering and disposal of surplus excavated soil as directed, within a lead of 50 meter.
Excavation of the cable trenches in hard rock not exceeding 1.5 meter in width, and lift upto 1.5 meter, including getting out the excavated soil and disposal of excavated soil as directed within a lead of 50 meter.
Filling available excavated earth (excluding rock) in trenches, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 meter.
Excavation for cable trenches of depth upto 1.2 m in soft soil including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 meter.
Fault finding of LT Cable of 1.1kV Grade, of any size and burried in ground or layed in open cable trenches or inside buildings above false ceilings or in shafts etc. as per the site requirement with fault locator machine to be hired from outside
Fault finding of HT Cable of 11kV Grade, of any size and burried in ground or layed in open cable trenches or inside buildings above false ceilings or in shafts etc. as per the site requirement with fault locator machine to be hired from outside
Painting with aluminium paint of approved brand and manufacture to give an even shade : 2 or more coats
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete
Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade: One or more coats on old work
French spirit polishing : Two or more coats including a coat of wood filler
Finishing walls with textured exterior paint of required shade : Old work (Two or more coats on existing cement paint surface applied @ 3.28 ltr/10 sqm.
Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm
Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineerin-charge .The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once irrespective of duration of scaffolding.
Services for cleaning of underground, overhead tanks in various buildings of campus . The cost includes washing, mechanical de-watering, sludge removal with pumps, high pressure washing, brushing, surface cleaning, vaccum cleaning and disinfection including spraying and UV air germicidal radiator, scaffolding, profit etc all inclusive for one year (4 times in a year i.e., each quarterly).
Services for external glass cleaning of Laboratory Building, Round Entrance reception at all height including cost of spider technique/mobile elevated working platform system with proper safety belts, other precautions, chemical fluid R2/R3 etc, tools, sealing any gaps in glass with structural sealant, scaffolding, if required, profits etc complete in all aspects. (4 times a year i.e., quarterly)
Cleaning of storm, sewer catch basin, pipe lines, manholes manually/mechanically for one year with deployment of workers/suction tanks as per requirement.
Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiberbrush. The material shall meet the requirements as specified in ACI212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage (For vertical surface two coats @ 0.70 kg per sqm)
Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiberbrush. The material shall meet the requirements as specified in ACI212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage (For horizontal surface one coat @1.10 kg per sqm)
Providing and injecting approved grout in proportion recommended by the manufacturer into cracks/honey-comb area of concrete/masonry by suitable gun/pump at required pressure including cutting of nipples after curing etc. complete as per directions of Engineer-Incharge (Epoxy injection grout in concrete/RCC work of approved make)
Filling the gap in between aluminium frame & adjacent RCC/ Brick/Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete :- Average 10 x 5 mm size (Area of lab- utility-1 side 2,3rd floor only)
ECS ENGINEERING CHD PVT LTD
Fair Deal Engineers
Anand And Company
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .