Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹71.7 LAccepted-AOC 245A 7A 1 JAYANTIPUR GOKUL AVAS YOJANA SULEM SARAI ALLAHABAD PRAYAGRAJ | PRAYAGRAJ | PRAYAGRAJ | UTTAR PRADESH | 211011 | L1 | Accepted-AOC being a lowest bidder | |
| 2 | L2₹74.5 L+₹2.8 L (3.84%)Rejected-Finance 00 JAI BHAWANI COMPLEX MAIN ROAD SADAR WARD JAGDALPUR BASTAR CHHATTISGARH 494001 | BASTAR | CHHATTISGARH | 494001 | L2 | Rejected-Finance other than lowest bidder | |
| 3 | L3₹76.6 L+₹4.9 L (6.80%)Rejected-Finance 10 SHANTI VIHAR RUDRAPUR UDHAM SINGH NAGAR UTTARAKHAND 263153 | UDAM SINGH NAGAR | UTTARAKHAND | 263153 | L3 | Rejected-Finance other than lowest bidder | |
| 4 | L4₹76.7 L+₹5.0 L (6.93%)Rejected-Finance 83 5M 1 SHIV GANGA PURAM YADAVPUR ROAD UMARPUR NEEWAN PRAYAGRAJ 211011 | PRAYAGRAJ | UTTAR PRADESH | 211011 | L4 | Rejected-Finance other than lowest bidder | |
| 5 | L5₹76.9 L+₹5.1 L (7.16%)Rejected-Finance | L5 | Rejected-Finance other than lowest bidder |
Tender Value
₹71.9 L
EMD Value
₹1.3 L
Closing Date
3 Jun 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE (AF) BAMRAULI
HQ CWE (AF) BAMRAULI Allahabad 211012
PROVN OF STORAGE ACCN FOR MAFI-I LEVEL SPARES AND TEST EQUIPMENT AT BAMRAULI
2019_MES_300604_2
87018/C/E8
Open Tender
Civil Works
Lump-sum
270 days
Bamrauli Allahabad
Please refer Tender documents.
9 documents required · 9 mandatory
₹1,000
GE (AF) Bamrauli
₹1.3 L
Yes
15 Jul 2020
9 May 2020
6 Jun 2020
9 May 2020
3 Jun 2020
26 May 2020
60 days
Amount
Lump Sum price worked out by the contractor for 'Building work' as inserted by the MES in Schedule ‘A’ Part I.
Lump Sum price worked out by the contractor for 'internal water Supply' as inserted by the MES in Schedule ‘A’ Part II.
Lump Sum price worked out by the contractor for 'Internal Electric Supply' as inserted by the MES in Schedule ‘A’ Part III.
Lump Sum price worked out by the contractor for 'External Water Supply' as inserted by the MES in Schedule ‘A’ Part IV.
Lump Sum price worked out by the contractor for 'External Electric Supply' as inserted by the MES in Schedule ‘A’ Part V.
Lump sum price worked out by the Contractor for “Road / Path / Culvert” as inserted by the MES in Schedule ‘A’ Part VI
Lump sum price worked out by the Contractor for “Sewage Disposal” as inserted by the MES in Schedule ‘A’ Part VII
Lump sum price worked out by the Contractor for “Area Drainage” as inserted by the MES in Schedule ‘A’ Part VIII
Lump sum price worked out by the Contractor for "Lightening Protection" as inserted by the MES in Schedule ‘A’ Part IX
Lump sum price worked out by the Contractor for "Earth Work" as inserted by the MES in Schedule ‘A’ Part X
Lump sum price worked out by the Contractor for Schedule `A' Part-XI (rate against Srl No. 11.01 to 11.20 shall be quoted by the Contractor)
Supply and fix bib tap with wall flange, fancy type, chromium plated, brass, screwd for 15mm bore iron pipe with capstain head complete . Note :- Bib tap cat part No F200003FT of Hindware, cat part No T3506A1 of Parryware or equivalent model of make as specified in Appendix 'B' to Particular specifications.
Supply and fix angular stopcock with wall flange, fancy type, chromium plated, brass, screwd for 15mm bore iron pipe with capstain head complete . Note :- Angular valve of cat part No F200005 of Hindware, cat part No T3507A1 of Parryware or equivalent model of make as specified in Appendix 'B' to Particular specifications.
Construction of soak well of size 1.8 metre (d) dia and 3.00 metre (effective depth) deep including excavation, foundation concrete, brick masnary, RCC slab in M-25 etc complete all as specified in particular specificatons and as shown on CELZ drawings No TD/576 sheet No 1/2 and 2/2.
Construction of septic tank for 25 users including excavation, foundation concrete, brick masnary, RCC slab in M-25 etc complete all as specified in particular specificaton and as shown on drawing No TD/217 Sheet No 1/2 & 2/2.
Supply, install, fixing and commissioning split type air conditioner of capacity 2.00 TR, five star rated with cordless remote control unit and in built air ioniser, plasma filter for better indoor air quality, star rated suitable for wall mounted, single phase, 230/250 volt AC including breaking necessary hole in wall for fixing indoor and outdoor unit and making good to disturbed surfaces with cement mortar to match with existing finishes after commissioning, making necessary connections unplasticised PVC pipes medium duty 25 mm dia for draining out condensed water all as required including necessary connection complete all as specified and directed. Note :- (i) Quoted rates deem to be included cost of drain pipe, copper tubing and 4 sqmm multi standard copper cable ( 3 mtr length each) , backet, hole in brick wall etc. (ii) Air conditioner shall be of make Carrier Model No 24K DURAFRESH NEO-X / Daikin Model No : Indoor unit - JTKJ60TV16U, Outdoor unit - RKJ60TV16U / Blue star Model No : DATU / LG Model No : KS-Q24ENXA, or equivalent model of make specified in Appendix 'B' to particular specifications. (iii) Installation and commissioning to be done through OEM / its authorised service centre / agency.
Supply only Automatic copper wound voltage stabilizer for low and high voltage correction equipped with electronic transistorised relay, time relay for two minute suitable for correction on single phase 50 cycles, AC supply volt meter indicator and input voltage 140 V to 280 V and stabilized voltage between 220 ±5% of capacity 5 KVA. Note : This item shall be fixed with AC catered in respective item of this schedule.
M&L for cutting/boring the existing GI pipe line upto 100mm dia and taking the connection by inserting tees of suitable size/ threading and make all leak proof connection complete all as specified and directed.
Construction of brick masonry pit chamber of internal size 900mm x 900mm x 1200mm with mild steel angle iron frame, plate cover, painted with two coats of anticrossive bitumen paint over a coat of red oxide primer after preparation of surface including locking arrangment and necessary excavation and earth work, PCC in foundation, brick work and cement plaster in internal surface of walls and outside upto 150mm deep below ground level etc complete all as specified and shown on drawing No. CEAF/TD/EM/01 Sheet No. 1/1
Supply, installing, testing and commissioning, factory made and tested (CPRI type test certified). LT feeder piller box , outdoor type , platform mounted, suitable for 415 volts, 3 phase, 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated aluminium bus bars 4 numbers 400 Amps capacity installed on porcelain insulators. The panel shall be dust and vermin proof, IP 54 class protection and made of 3.15 mm CRCA MS sheet and frame work, front and back opening type with aprons for cable entry, with double door shutter and locking arrangement ( including provn of 65mm Godrej (Freedom) lock with 2 key), including internal wiring with suitabe size PVC insulated multistranded copper conductor FRLS cable, (not less than 2.5 Sqmm) 1100 volts grade. All steel metal work including frame shall be with anticrossive coating with seven tank process and finally epoxy polyster powder coating of flint grey shade the scope of work comprising the following :- (a) Incoming :- (i) MCCB 200 Amps, 4 pole, 415 volts, 36 KA, with adjustable thermal setting - 01 Number. (iii) Phase indicating lamps neon type RYB ( Red, Yellow and Blue colours) - 01 set. (b) Outgoing :- (i) MCCB, 160 Amps, 4 pole, 415 volts, 25 KA with adjustable thermal setting -01 Number. (ii) MCCB 100 Amp, 4 pole, 415 volts, 25 KA with adjustable thermal setting -01 Number. (iii) Amp meter (0-200Amps) (iv) Volt meter (0-500volt).
Supply and fixing type 1+2 AC surge protection device three phase and neutral of capacity high discharge current maximum 50KA (L-N), 70KA (N-E) and voltage protection of 1.5KV including all fixing arrangement to wall / pannel with minimum 2.5 sqmm copper conductor cable all as specified and directed by Engr-in-Charge.
Material and Labour for making 'Tercel' High conductive, Non corrosive, Maintenance free and repairble Çhemrod'Electro-Chemical-Gel earth pit using earth enhcancing compound ISOGEL of 30 Kg kit, CPRI tested ISOROD of 3 inch dia, 8 ft long and 0.12 inch thick made of K type electrolytic copper with top removal gell filling cap, seepage holes, stainless steel fasteners, HDP Lockable earth pit cover cum inspection chamber and all required accessories inlcuding design modicications to achieve the required earth termination rod resistance value below 2 ohms or as per the OEM / Internation standrad recommendation.
Supply, fixing in replacement and connecting wall mounted LED light fitting 1 x 20 Watt LED (6000K/6500K) (1200/1144mm) extruded aluminium heat sink provided for efficeint heat dissipation intergrated electronic driver including necessary electric connection complete all as specified and directed.. Note :- Fitting shall be of Make Philips cat part No BN021C LED20S PSU CW GR S2, Havells cat part No LUMILINEBS20WLED840SPCWH or equivalent model of make specified in Appendix 'B' to particular specifications.
Supply,fixing and connecting wall mounted LED light fitting 2 x 20 Watt LED (6000K/6500K) (1200/1144mm) extruded aluminium heat sink provided for efficeint heat dissipation intergrated electronic driver including necessary electric connection complete all as specified and directed. Note :- Fitting shall be of Havells cat part No ENDURALINEARNEOBS20WLED840SPCWH or equivalent model of make specified in Appendix 'B' to particular specifications.
Supply only ceiling fans 1200 mm sweep white in colour of Aluminium blades(three numbers) and body,double ball bearing, down rod, .fan motor, pair of canopy, shackle, assembly kit etc suitable for SP 230 to 250 volts, 50 Hz, AC supply complete. Make :- Havells CAT No ES-50 5 star (energy saving fan) or equivalent model of make specified in appendix 'B' to particular specifications.
Supply only ceiling fans 1400 mm sweep white in colour of Aluminium blades(three numbers) and body,double ball bearing, down rod, .fan motor, pair of canopy, shackle, assembly kit etc suitable for SP 230 to 250 volts, 50 Hz, AC supply complete. Make :- Havells CAT No ES-50 5 star (energy saving fan) or equivalent model of make specified in appendix 'B' to particular specifications.
Supply only exhaust fans of 300/308 mm sweep, heavy duty, four blade, double ball bearing ,1400 RPM, minimum suitable for SP, 230 / 250V, 50 Hz, AC supply with louver shutters complete. Make Havells Model No : TURBOFORCE or equivalent model of make mentioned in Appendix 'B' to particular specifications.
MCB, single pole and neutral, 415 volts, 40 Amps rating, 10KA, "C" series fixed in DBs (DBs catered separately in schedule 'A' Part III). Note : Make of the MCB should be the same as that of DB, catared under schedule 'A' Part III
MCB, tripple pole and neutral, 415 volts, 63 Amps rating, 10KA, "C" series fixed in DBs (DBs catered separately in schedule 'A' Part III). Note : Make of the MCB should be the same as that of DB, catared under schedule 'A' Part III
MCBs, 'C' series, SP, 6 Amps to 32 Amps, 230/240 Volts, 10 KA breaking capacity,IS-8828 marked and rating and fixing in DBs (DBs catered separately in schedule 'A' Part III).- Note: Make of the MCB should be the same as that of DB, catared under schedule 'A' Part III
sanjay enterprises
M/S Amar Enterprises
chauhan construction
M/s NSA Engineering Corporation
Ambrish Builders
Agrawal Enterprises
DEORA ELECTRIC WORKS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .