Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.6 LAccepted-AOC 01 PATHWALIYA GONDA GONDA GONDA UTTAR PRADESH 271001 | GONDA | UTTAR PRADESH | 271001 | L1 | Accepted-AOC Lowest amount quoted | |
| 2 | L2₹34.2 L+₹4.6 L (15.6%)Rejected-Finance | L2 | Rejected-Finance Second Lowest amount quoted | |
| 3 | L3₹36.7 L+₹7.2 L (24.2%)Rejected-Finance HO SR NO 73 TAPKIR MALA CHOWK TAPKIR NAGAR KALEWADI PIMPRI PUNE 411017 | PUNE | MAHARASHTRA | 411017 | L3 | Rejected-Finance Third Lowest amount quoted | |
| 4 | L4₹39.3 L+₹9.7 L (32.9%)Rejected-Finance PLOT NO 81 SHANTAJI COLONY JANKI NAGAR JABALPUR MP PIN 482002 | JABALPUR | MADHYA PRADESH | 482002 | L4 | Rejected-Finance Fourth Lowest amount quoted | |
| 5 | L5₹39.7 L+₹10.2 L (34.4%)Rejected-Finance MAIN ROAD RANJHI BAZHAR JABALPUR MP PIN 482005 | JABALPUR | MADHYA PRADESH | 482005 | L5 | Rejected-Finance Highest amount quoted |
Tender Value
₹38 L
EMD Value
₹76,000
Closing Date
5 Sept 2020, 6:00 pmClosed
Shri B M Verma, IDSE, EE(SG)
Garrison Engineer (East), Near COD Estate, Ranjhi, Jabalpur (MP)-482011
As per BOQ
2020_MES_367494_1
8269/E8
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
Garrison Engineer (East) Jabalpur
D a(ii)
8 documents required · 8 mandatory
₹500
Garrison Engineer (East) Jabalpur
₹76,000
Yes
3 Oct 2020
7 Aug 2020
8 Sept 2020
7 Aug 2020
5 Sept 2020
22 Aug 2020
7 Aug 2020 - 21 Aug 2020
Amount
Excavation in trenches, not exc 1.5 mtr wide and not exc 1.5 mtr deep for fundations, manholes, laying GI/CI pipes etc n.exc 10Sqm on plan and getting out in soft/loose soil complete all as specified and directed
Returning, filling in, including spreading, levelling, watering and well ramming in layer not exce 25Cm thick complete all as specified and directed
Removing excavated soil to a distance not exce 50 mtr and deposited where directed at a level not exceeding 1.5 mtr above the starting point all as specified and directed.
Cutting existing the following cast iron pipes in position for insertion of new pipe/tees, branches etc. complete all as specified.
250 mm bore
200 mm bore
150 mm bore
100 mm bore
Taking up the following cast iron water mains (including all fittings) incuding flanged ends rubber joints with spigot and socket ends and lead joint including burning out joints and recovering lead of size :- Note : Excavation/earth work shall be measured and paid separately.
250 mm bore
200 mm bore
150 mm bore
100 mm bore
80 mm bore
S&F the following cast iron pipes with spigot and socket ends centrifugally cast, Class LA, in any length laid in trenches of size complete all as specified and directed. Make : TATA/Keso Ram/Electro Steel
250 mm bore
200 mm bore
150 mm bore
100 mm bore
80 mm bore
M&L for run lead joints for the following size of pipes complete for water mains with spigot & socket pipes and fittings complete all as specified and directed:-
250 mm bore
200 mm bore
150 mm bore
100 mm bore
80 mm bore
S&F the following rubber tyton joint of size:-
250 mm bore
200 mm bore
150 mm bore
100 mm bore
80 mm bore
S&F rubber gasket joint for flanged end pipe & fittings of following size :
250 mm bore
200 mm bore
150 mm bore
100 mm bore
80 mm bore
S&F in repairs machanical Gypsum joint ISI marked for spigot end pipe of following sizes:-
250 mm bore
200 mm bore
150 mm bore
100 mm bore
80 mm bore
S&F 200/250mm bore spigot/flanged/ socketed CI fittings. such as bends (any type radius and angle), tapers, tees, collars & tail piece socket/flanged/spigot etc complete all as specified.
Dismantling/taking out unserviceable sluice valve of size 80mm to 250mm bore dia by opening/cutting rusted nuts, bolts etc all as specified and directed.
S&F the following CI sluice valves both ends flanged and drilled, bonnet wedge stuffing box. Gland trust plate, hand wheel made out of grey CI, complete valve confirming to IS 14846/2000 and its fittings suitable for hydraulic test pressure of 15 Kg/sqcm PN 1.0 ISI marked complete all as specified and directed:- Make : Kirloskar/L&T/Upadhyay
80 mm bore
100 mm bore
S&F the following CI sluice valves both ends flanged and drilled, bonnet wedge stuffing box. Gland trust plate, hand wheel made out of grey CI, complete valve confirming to IS 14846/2000 and its fittings suitable for hydraulic test pressure of 15 Kg/sqcm PN 1.6 ISI marked complete all as specified and directed:- Make : Kirloskar/L&T/Upadhyay
150 mm bore
200 mm bore
250 mm bore
Dismantling/taking out unserviceable air release valve/non return/foot valve/fire hydant valve of any size by opening/cutting rusted nuts, bolts etc all as specified and directed.
Supply and fix CI double end flanged and drilled non return valve of size 200 mm PN-1.6 dia ISI MARKED MAKE : Kirloskar/Upadhyay/L&T
Supply and fix CI double end flanged and drilled non return valve of size 150 mm dia PN-1.6 ISI MARKED MAKE : Kirloskar/Upadhyay/L&T
Supply and fix CI double end flanged and drilled non return valve of size 100 mm dia PN-1.6 ISI MARKED MAKE : Kirloskar/Upadhyay/L&T
Supply and fix CI foot valve, flanged end and drilled of size 150 mm dia ISI MARKED MAKE : Kirloskar/Upadhyay/L&T
Supply and fix CI foot valve, flanged end and drilled of size 100 mm dia ISI MARKED MAKE : Kirloskar/Upadhyay/L&T
Supply and fix cast iron double ball air release valves of size 80mm as per IS 14845, PN rating H-7 ISI marked. MAKE : Kirloskar/Upadhyay/L&T
Cutting of road /hard standing for laying /dismentling of pipe line and making good surfaces matching with the existing surface after laying of pipe line.up to 30 cm
Dismantling of existing valve pit and M&L for construction of masonry valve pit (as per drawing No CEJZ/TD/819/91 dated 16/04/91) with the following specification:- Brick work in CM (1:4) with sub class 'B' bricks, 15mm thick plastering in CM (1:4), PCC (1:4:8) type D-2 in foundation, chamber of internal size 1200 x 1200x1200 mm,150mm thick copping on top in PCC (1:3:6), type C-1, 3mm thick MS sheet for cover, angle iron 40mmx40mmx5mm for frame all around with suitable handle with locking arrangement including two coats of synthetic enamel paint over a coat of red oxide primed on MS work and three coats of white wash and preparation of surfaces complete all as specified and shown on drawing
Dismantling of existing valve pit and M&L for construction of masonry valve pit (as per drawing No CEJZ/TD/819/91 dated 16/04/91) with the following specification:- Brick work in CM (1:4) with sub class 'B' bricks, 15mm thick plastering in CM (1:4), PCC (1:4:8) type D-2 in foundation, chamber of internal size 900 x 900x1200 mm,150mm thick copping on top in PCC (1:3:6), type C-1, 3mm thick MS sheet for cover, angle iron 40mmx40mmx5mm for frame all around with suitable handle with locking arrangement including two coats of synthetic enamel paint over a coat of red oxide primed on MS work and three coats of white wash and preparation of surfaces complete all as specified and shown on drawing
Taking up or down the following old unserviceable GI Tubing and connections including cleaning for refixing:- Note :- Excavation/earthwork shall be measured & paid separately.
15 mm bore
20 mm bore
25 mm bore
40 mm bore
50 mm bore
80 mm bore
100mm bore
Refixing the following old GI Tubing and connections in New or old position (walls, Ceiling, Floors etc) of sizes:-
15 mm bore
20 mm bore
25 mm bore
40 mm bre
Laying only the followiing old serviceable removed GI Tubing from site and connection in New or old position (in trenches) of sizes :-
20 mm bore
25 mm bore
40 mm bore
50 mm bore
S&F the followiing GI tubing medium grade with all fittings and fixed complete laid in trenches of size :-
20 mm bore
25 mm bore
40 mm bore
50 mm bore
80 mm bore
100mm bore
S&F the followiing GI tubing medium grade with all fittings complete to walls and ceilings or laid in floors of size :
15 mm bore
20 mm bore
25 mm bore
40 mm bore
Taking down/removing the following Unserviceable Gate valve/stop valve from water supply lines, closing the opening with plug or preparing for new as required necessary fittings complete all as specified.
20 mm bore
25 mm bore
40 mm bore
50 mm bore
S&F the followiing Gun metal Globe or Gate valve with iron wheel head, screwed both ends for iron pipe and fixed with required necessary GI fittings complete :- Make : Kirloskar/Zolto/L&T/Leader
20 mm bore
25 mm bore
40 mm bore
50 mm bore
Taking down/removing unservieable bib taps 15/20mm bore from pipe line/tanks complete all as specified and directed.
S&F 15mm bore bib tap cast copper alloywith crutch/buterfly handle screwed for iron pipe complete all as specified. Make - Prayag/Marc/Zoloto
S&F 15mm bore bib tap standard of PTMT any colour (minimum wt 15mm - 90gms) screwed for iron pipe complete all as specified. Make - Prayag/Polytuff.
Cutting the following existing galvanised iron pipe in position for insertion of new pipe/tees, branches etc.
15 mm bore
20 mm bore
25 mm bore
40 mm bore
50 mm bore
80 mm bore
100 mm bore
S&F in replacement the following stainless steel spindle suitable for following dia of sluice valve complete with stainless steel nut and threading as per sample & directed by engr-in- charge
250 mm bore sluice valve
200 mm bore sluice valve
150 mm bore sluice valve
100 mm bore sluice valve
80 mm bore sluice valve
S&F in replacement Digital water leval indicator system 150 mm size digit direct display,operated on 230v Ac, suitable for upto 20 metre height over head Reservior/underground sump of any capacity, preadjustable alarm for upper & lower level, temp range -5 to 50 degree, humidity up to 90% RH, reset push switch for silent the alarm including 4 core 1.5 sqmm copper cable. MAKE: SURYA ELECTRONICS & CONTROLS / RECTRONIC DEVICE & CONTROLS
Taking up Submersible Pump assembly including column pipe approx 50 to70 mtrs using chain pulley block manually and carrying out following phase of work all as directed for 17.5HP/15 HP Pump Set .(i) Transportation of submersible pump -motor assembly for necessary repair. (ii) Carrying out overhauling of motor assembly 3phase ,taking out burnt winding wire, with & including PVC insulated water proof copper wire with winding wire of appropriate gauge and turn, providing insulation materials and replacement of bearing and assembling with repaired/serviceable pump and testing complete all as directed by Eng-in Charge. (iii) Carrying out dismantling and overhauling of multi stage pump, incl cleaning and derusting of casing, replacement of worm out spare like bearings, impellar bushing, coupling etc & refixing of existing serviceable components after proper cleaning, machining all as required & assembling testing at workshop complete for 17.5/15 HP submersible pump of any make including carrying out painting by two coats of synthetic enamelled paint over a coat of primer,assembling the pump and motor including testing complete all as specified and directed.
Taking up Submersible Pump assembly including column pipe approx 50 to70 mtrs using chain pulley block manually and carrying out following phase of work all as directed for 12.5/10 HP Pump Set .(i) Transportation of submersible pump -motor assembly for necessary repair. (ii) Carrying out overhauling of motor assembly 3 Phase ,taking out burnt winding wire, with & including PVC insulated water proof copper wire with winding wire of appropriate gauge and turn,providing insulation materials and replacement of bearing and assembling with repaired/serviceable pump and testing complete all as directed by Eng-in Charge. (iii) Carrying out dismantling and overhauling of multi stage pump, incl cleaning and derusting of casing, replacement of worm out spare like bearings, impellar bushing, coupling etc & refixing of existing serviceable components after proper cleaning, machining all as required & assembling testing at workshop complete for 12.5/10 HP submersible pump of any make including carrying out painting by two coats of synthetic enamelled paint over a coat of primer,assembling the pump and motor including testing complete all as specified and directed.
Taking up Submersible Pump assembly including column pipe approx 50 to70 mtrs using chain pulley block manually and carrying out following phase of work all as directed for 7.5/5 HP Pump Set .(i) Transportation of submersible pump -motor assembly for necessary repair. (ii) Carrying out overhauling of motor assembly 3 Phase ,taking out burnt winding wire,with & including pre insulated water proof copper wire with using winding wire of appropriate gauge and turn, providing insulation materials and replacement of bearing and assembling with repaired/serviceable pump and testing complete all as directed by Eng-in Charge. (iii) Carrying out dismantling and overhauling of multi stage pump, incl cleaning and derusting of casing, replacement of worm out spare like bearings, impellar bushing, coupling etc & refixing of existing serviceable components after proper cleaning, machining all as required & assembling testing at workshop complete for 7.5/5 HP submersible pump of any make including carrying out painting by two coats of synthetic enamelled paint over a coat of primer,assembling the pump and motor including testing complete all as specified and directed.
Note for item No 38 to 40 (i) Cost of disconnection of electric connection from LT control panel & starter of submersible pumping set & reconnecting with existing pipe and making electrical connection with panel board & starter shall be included in the quoted rate of these items. (ii) Cost of lowering of submersible pump set of any size after repairs and re-connecting with existing pipe shall be included in the quoted rate of these items. (iii) Cost of spare parts shall be included in the quoted rate of these items. (iv) The contractor shall be repair the submersible pump and motor within 72 hours after receiving the complaint failing which recovery/penalty shall be imposed @ Rs 500.00/day. The same shall be recovered from the RAR/FB.
Disconnecting electrically and disengaging the AC Squirrel cage induction motor 3 phase 415 Vlots, 50 Cycles, and taking out to local workshop induction motor 60/50/40 HP for repair purpose including complete cleaning,varnishing ,insulation and greasing and including shifting back to location as directed, installing, testing and commissioning after repair complete all as specified and directed. Note- Rewinding will be measure & paid seperately under relavant item of sch.
Disconnecting electrically and disengaging the AC Squirrel cage induction motor 3 phase 415 Vlots, 50 Cycles, and taking out to local workshop induction motor 12.5/15/25 HP for repair purpose including complete cleaning,varnishing, reinsulation and greasing and including shifitng back to location as directed, installing, testing and commissioning after repair complete all as specified and directed. Note:- Rewinding will be measure & paid seperately under relavant item of sch.
M&L for Rewinding the motor with super enamelled copper winding wire with appropriate same gauge of exsisting coil with similar class of exsisting insulation as recommended by manufacturer with high quality normex insulating paper applying best quality insulating varnish on stator/rotor windings drying them completely, testing the insulations as directed by engr-in-charge.Make:Atlas/BWC/Swastik/Chetak
Taking down unservicable existing motor starter of any size/capacity
M&L Fully Automatic Star Delta Motor starter 50 HP in sheet-steel enclosure type ML with single phase protection feature (Motor Rating AC-3 Duty, 415V, 50Hz, 3-Ph) and Relay Range 28-42 complete all as specified. (Make : L&T cat no SS 91730 or Equivalent OF SIEMENS/schneider)
M&L Fully Automatic Star Delta Motor starter 35 HP in sheet-steel enclosure type ML with single phase protection feature (Motor Rating AC-3 Duty, 415V, 50Hz, 3-Ph) and Relay Range 22-32 complete all as specified. (Make : L&T cat no SS 91730 or Equivalent OF SIEMENS/schneider)
M&L Fully Automatic Star Delta Motor starter 25 HP in sheet-steel enclosure type MK-1 .feature (Motor Rating AC-3 Duty, 415V, 50Hz, 3-Ph) and Relay Range 13-21 complete all as specified. (Make : L&T cat no SS 91855 or Equivalent OF SIEMENS/schneider)
M&L Fully Automatic Star Delta Motor starter 15 HP in sheet-steel enclosure type MK-1 .feature (Motor Rating AC-3 Duty, 415V, 50Hz, 3-Ph) and Relay Range 11-18 complete all as specified. (Make : L&T cat no SS 96257 or Equivalent OF SIEMENS/schneider)
M&L Fully Automatic Star Delta Motor starter 12.5 HP in sheet-steel enclosure type MK-1 .feature (Motor Rating AC-3 Duty, 415V, 50Hz, 3-Ph) and Relay Range 9-14 complete all as specified. (Make : L&T cat no SS 96257 or Equivalent OF SIEMENS/schneider)
M&L Fully Automatic DOL Motor starter 7.5 HP in sheet-steel enclosure type MK-1 .feature (Motor Rating AC-3 Duty, 415V, 50Hz, 3-Ph) and Relay Range 13-22 complete all as specified. (Make : L&T cat no SS 96228 or Equivalent OF SIEMENS/schneider)
M&L Fully Automatic DOL Motor starter 3 HP in sheet-steel enclosure type MF-1. feature (Motor Rating AC-1 Duty, 230V, 50Hz, 1-Ph) and Relay Range 10.5-17.5 .(Make : L&T cat no cs90319kodo or Equivalent OF SIEMENS/schneider)
Taking down unservicable existing cable from motor/pannel to starter any size/capacity
S & F PVC Insulated unsheathed cable 19/1.54 mm dia single core multistranded bright annealed copper conductor 1100 volts, including taking down conf to IS-694 complete all as specified. Make : Finolex/HPL India/RPG
S & F PVC Insulated unsheathed cable 37/1.56 mm dia single core multistranded bright annealed copper conductor 1100 volts, including taking down conf to IS-694 complete all as specified. Make : Finolex/HPL India/RPG
S & F PVC Insulated unsheathed cable 37/2.04 mm dia single core multistranded bright annealed copper conductor 1100 volts, including taking down conf to IS-694 complete all as specified. Make : Finolex/HPL India/RPG
S&F in repairs MCCB 250 A 35 KA, 4 POLE ,thermal magnetic relese, Ics=100% Icu complete all as specified Make : L&T / Schneider/Legrand
S&F in repairs MCCB 200 A 35 KA,4 POLE ,thermal magnetic relese, Ics=100% Icu complete all as specified Make : L&T / Schneider/Legrand
S&F in repairs MCCB 160 A 35 KA, 4 POLE ,thermal magnetic relese, Ics=100% Icu complete all as specified Make : L&T / Schneider/Legrand
S&F in repairs MCCB 125 A 25 KA,4 POLE ,thermal magnetic relese, Ics=100% Icu complete all as specified Make : L&T / Schneider/Legrand
S&F in repairs MCCB 100 A 25 KA, 4 POLE ,thermal magnetic relese, Ics=100% Icu complete all as specified Make : L&T / Schneider/Legrand
S&F in repairs MCCB 63 A 16 KA,4 POLE ,thermal magnetic relese, Ics=100% Icu complete all as specified Make : L&T / Schneider/Legrand
S&F in repairs MCCB TP 63 Amps , 415Volts, 35KA, 3 POLE Make: L&T / LEGRAND/ ABB
S&F in repairs MCCB TP 100 Amps , 415Volts, 35KA, 3 POLE Make: L&T / LEGRAND/ ABB
S&F in repairs MCCB TP 125 Amps , 415Volts, 35KA, 3 POLE Make: L&T / LEGRAND/ ABB
S&F in repairs MCCB TP 160 Amps , 415Volts, 35KA, 3 POLE Make: L&T / LEGRAND/ ABB
M&L draining water from OH reservoirs not exc. 18 Mtr head/staging, and cleaning internal portion of tank (bottom and walls) by means coir / wire brush etc. and wash the internal portion of tanks by using bleaching powder @ 25 grams per 1000 Ltrs of water after removing sludge and mud etc to a distance not exc 50 mtr including one coat of synthetic enamel paint on all steel surfaces such as ladder, railing, inlet & over flow CI pipes connected sluice valves of the respective OH tanks/ground level reservoir etc writing letters with white paint (date of cleaning and capcity of tank) on black painted surface of tanks all as directed by Engineer-in-Charge.
100000 gallons capcity
50000 gallons capcity
All as per item No 66 above but exceeding 18 Mtr head / staging for the following :
100000 gallons capcity
All as per item No 66 above but semi underground reservoir/sump of 200000 gallons cap each tanks devided in two poriton
All as per item No 66 above but semi underground reservoir/sump of 100000 gallons cap each tanks devided in two poriton
All as per item No 66 abovebut semi underground reservoir/sump of 50000 gallons cap each tanks devided in two poriton
All as per item No 66 abovebut semi underground reservoir/sump of 25000 gallons cap each tanks devided in two poriton
Cutting and threading of existing GI pipe 100 mm dia
Cutting and threading of existing GI pipe 80 mm dia
Cutting and threading of existing GI pipe 50 mm dia
Cutting and threading of existing GI pipe 40 mm dia
S&F in repairs GI long socket suitable for 100 mm dia and 100 mm long
S&F in repairs GI long socket suitable for 80 mm dia and 100 mm long
S&F in repairs GI long socket suitable for 50 mm dia and 100 mm long
S&F in repairs GI long socket suitable for 40 mm dia and 100 mm long
S&F in repairsPVC cable duct B type of size 150 mm x 100 mm, Make : L&T/SALZER
S&F in repairsPVC cable duct B type of size 100 mm x 80 mm, Make : L&T/SALZER
S&F in repairsPVC cable duct COVER for B type of size 150 mm, Make : L&T/SALZER
S&F in repairs PVC cable duct COVER for B type of size 100 mm, Make : L&T/SALZER
Taking down and re-fixing of 50 HP pump and motors to existing line with 100/150 mm CI pipe and build BED/foundation in PCC 1:4:8 to the pump and motors to the site as directed by Engr-in-Charge. Rate of POCC shall be incl in the quoted rate. Earthwork shall be measured and paid separately.
S&F in repairs heating element 2000 watt of any type to fulfill the requirement of geyser of Make Bajaj / Tosiba / Havells all as specified and directed by Engineer –in-Charge
Supply & Fix in replacement leather for packing of foot valve and other pumping equiptment of any size all as per site requirement all as directed by Engr-in-Charge.
Taking down unservicable existing spare coil/cotactor/over load relay/miniprotection relay of any size/capacity
S&F spare coil for power contactor amp of make L&T/schinder/ABB
S & F Thermal over load relay for type ML-1 complete all as specified. Make : L&T/ Siemens/ Havells
S & F Thermal over load relay for type ML-2/3 complete all as specified. Make : L&T/ Siemens/ Havells
S & F Thermal over load relay for type ML-6 complete all as specified. Make : L&T/ Siemens/ Havells
S & F Thermal over load relay for type MK-1 complete all as specified. Make : L&T/ Siemens/ Havells
S&F Power contactor ML-1.5 , 3 pole rating not less than 40 A with 230 coil make : L&T/ SEIMENS/ABB
S&F Power contactor ML-2 , 3 pole rating not less than 40 A with 230 coil make : L&T/ SEIMENS/ABB
S&F Power contactor ML-3 , 3 pole rating not less than 40 A with 230 coil make : L&T/ SEIMENS/ABB
S&F Power contactor ML-4 , 3 pole rating not less than 40 A with 230 coil make : L&T/ SEIMENS/ABB
S&F Power contactor ML-6 , 3 pole rating not less than 40 A with 230 coil make : L&T/ SEIMENS/ABB
S&F MINI PROTECTION RELAY with built in earth fault relay ,MODEL NO-MRP300 ,8 to 22 amp ,230 v coil make : L&T/ SEIMENS/ABB
S&F MINI PROTECTION RELAY with built in earth fault relay ,MODEL NO MRP300, 16 to 44 amp ,230 v coil make : L&T/ SEIMENS/ABB
S&F MINI PROTECTION RELAY with built in earth fault relay, MODEL NO,MRP300 ,32 TO88 amp ,230 v coil make : L&T/ SEIMENS/ABB
Taking down unservicable existing VOLT MTER/ AMMETER/INDICATION LAMP/CTS of any size/capacity
S&F ammeter Class-1,digital pannal mounting type 96mmx96mm L&T cat no WDS301FCA00 or equivalent series of AE/ABB
S&F voltmeter Class-1, digital pannal mounting type 96mmx96mm L&T CAT NO.WDS301FEV00 or equivalent series of AE/ABB
S&F LED MULTIFUCTIONAL METER Class-1, digital pannal mounting type 96mmx96mm L&T CAT NO.WDV303FC000 or equivalent series of AE/ABB
S&F LED TYPE indicator lamp Make : AE/ABB/Schneider
S&F CT 400/5 amps Make : AE/ABB/Schneider
S&F CT 300/5 amps Make : AE/ABB/Schneider
S&F CT 200/5 amps Make : AE/ABB/Schneider
Disconnecting & taking down all connection of LT pannel board/FPB , incomming & outgoing LT cable, including internal wiring & internal connection & addition / alteration /repair to exsisting pannel/FPB by cutting/welding/drilling/granding & replace all internal connection by XLPE insulated single core multistranded alluminium conductor cable of suitable size for outgoing MCCB/MCB/CUTOUT including alluminium lugs & connecting all incomming & outgoing cables with alluminium heavy duty lugs & testing after repair all as specified & directed by engr-in-charge
Material and labour for painting of LT pannel board/ LT feeder piller box, indoor/out door type any size/capacitywith smoke gray colour synthetic enamel paint one coat over the existing paint after cleaning and removing the dust and durt and cleaning with sand paper complete including writting letters 100 mm heigh with white synthetic enamelled paint complete all as specified and as directed by Engg-in-charge
Material and labour for painting of motor and pump with smoke gray colour synthetic enamel paint one coat over the existing paint after cleaning and removing the dust and durt and cleaning with sand paper complete including writting letters 100 mm height with white synthetic enamelled paint complete all as specified and as directed by Engg-in-charge
Material and labour for painting of pipe line with synthetic enamel paint one coat over the existing paint after cleaning and removing the dust and durt and cleaning with sand paper complete including writting letters 100 mm height with white synthetic enamelled paint complete all as specified and as directed by Engg-in-charge
Taking down old glow sign Board & supply & fix sign Board made out of acrylic white sheet 3 mm thick with including writting letters up to 100 mm height with sticker complete all as specified and as directed by Engg-in-charge
Taking down u/s LT U/G cable (including all mounting accessories, bricks and sand etc ) from trenches, wall, floor etc and removing to store for safe custody upto 25 sqmm complete all as specified and directed. Note:- Excavation for taking out cable will not paid for separately, the cable shall be deemed to have taken down from the trenches excaveted for laying of cables.
Taking down u/s U/G cable (including all mounting accessories, bricks & sand etc) from trenches, wall, floor etc and removing to store for safe custody above 35 upto 120 Sqmm complete all as specified and directed. Note:- Excavation for taking out cable shall not be paid separately, the cable shall be deemed to have taken down from the trenches excaveted for laying of cables.
S&F XLPE insulated armoured and PVC sheathed "heavy duty" electric cable with aluminium conductor 1100 volts grade laid in trenches, passing through pipes /ducts including testing complete of following cross sectional area of the following sizes:- Note:- Rate is inclusive of cable gland & cable lugs. The contractor shall be used old cable route indicator retrietive from item No 33 to 35 above. Fixing cost for the same shall be included in the quoted rates of these items. Make : Finolex/RR Kabel/Universal
2 core, 10 sqmm cross sectional area
4 core, 16 sqmm cross sectional area
3-1/2 core, 25 sqmm cross section area
3-1/2 core, 35 sqmm cross section area
3 -1/2 core, 50 sqmm cross sectional area
3 -1/2 core, 70 sqmm cross sectional area
3 -1/2 core, 95 sqmm cross sectional area
3 -1/2 core, 120 sqmm cross sectional area
3 -1/2 core, 150 sqmm cross sectional area
S&F in repairs 40mm bore, GI steel tubing "light grade" for cable protection passing under road /floor or for fixing to poles complete all as specified and as directed Make :- JINDAL/ ZENITH/ TATA/ PRAKASH
S&F in repairs 50mm bore GI steel tubing "light grade" for cable protection passing under road /floor or for fixing to poles complete all as specified and directed Make - JINDAL/ ZENITH/ TATA/ PRAKASH
S&F in repairs 80mm bore GI seel tubing "light grade" for cable protection passing under road /floor or for fixing to poles complete all as specified and directed Make - JINDAL/ ZENITH/ TATA/ PRAKASH
M&L unwashed Sand cushioning to under ground cable provided with a layer of 8 cm deep before laying and 15 cm covering above the top edge of cable after laying complete all as specified. Note : Measurement shall be done after puning down of sand.
M&L Brick covering with width equal to length of bricks as mechanical protection to cable with well burnt sub class `B` old size bricks laid dry and flat complete all as specified and as directed.
Removal of unwanted vegetation/bushes/small plants shrubs around the water supply installations/ inside the valve pit and surface excavation not esceeding 15 cm depth leveling the ground and removing the excavated material to a distance exceeding 50 M.
Supply only ALTOCH - GP (Calcium based granular disinfectant for water treatment, more stable than Chlorine Gas, and stronger than bleachingpowder, and sodium Hypochlorite) packing in 45 kg drum completed all as specified & directed by Engr-in-Charge. Make : Dclibak, Potter & Watt Corporation or E-in-C's approvals.
Schedule of credit amount of Rs. 2,91,220.00 to be deducted during AOC
DIAMOND ELECTRICALS
Goodluck Enterprises
shri krishna traders
ELCON
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .