Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance A 99 SECTOR 4 AIROLI NAVI MUMBAI 400708 | NAVI MUMBAI | THANE | MAHARASHTRA | 400708 | Admitted-Finance |
| 3 | Admitted-Finance NO 24 SALARPURIA ARENA ADUGODI HOSUR MAIN ROAD BANGALORE KARNATAKA 560030 | BENGALURU URBAN | KARNATAKA | 560030 | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
Closing Date
20 Sept 2022, 3:00 pmClosed
Sr contracts officer
IOCL MKTHO
Supply , Installation of New VRV ACs with buyback of old VRV system at IOCL, Marketing Head Office, Mumbai
2022_MKTHO_155307_1
HCC/IS-8/PT-75/2022-2023
Open Tender
Miscellaneous Goods
Supply
42 days
Mumbai
As per tender document
7 documents required · 7 mandatory
Exempted
Through videoconferencing
7 Nov 2022
26 Aug 2022
21 Sept 2022
26 Aug 2022
20 Sept 2022
6 Sept 2022
26 Aug 2022 - 1 Sept 2022
1 Sept 2022
Amount
SUPPLY OF VARIABLE REFRIGERANT AIR CONDITIONERS ( Please refer Annexure for technical specification details) Outdoor/Indoor Units
For VRV Outdoor Units (10 HP)
For Hi-wall AC Unit ( 2TR) with wireless Remote controller
For Hi-wall AC Unit (1.5TR) with wireless Remote controller
For Cassette Unit ( 4TR) with wireless Remote controller
For Cassette Unit ( 3TR) with wireless Remote controller
Refnets Joints (insulated with aerotape)
Supply of Refrigerant Control "Y" / "Tee" joints with insulation for piping (Refnets)
Refrigerant Piping
Supply of Copper Refrigerant Suction line with 19 mm or better thick rubber nitrile tubular insulation.
Supply of Copper Refrigerant Liquid line with 19 mm or better thick rubber nitrile tubular insulation.
Control Cabling
Supply of Control Cabling (2 core x 1 Sq. mm copper cable) from Indoor units to Outdoor units with hard PVC Conduit including cable required from outdoor unit to Central Controller.
CONTROLLER : Supply of Central Controller for controlling all the indoor and outdoor units and should be capable of integration with BMS system. All the outdoor/indoor unit parameters shall be integrated through BMS & required hardware/software to be included via Modbus/Bacnet.
Supply of drain pipes with thermal insulation
25mm or better PVC Hard Pipe
32mm or better PVC Hard Pipe
40mm orbetter PVC Hard Pipe
Miscellaneous fittings and accessories
Supply of Suspension Rods with cleat angle to hang the indoor units
Supply of Refrigerant Charging with R-410 GAS ( or better )for commissioning of VRV System
Supply of MS Stands for indoor & outdoor units with rubber pads & the frame should be painted hot dip galvanised for outdoor units MS Framework for Outdoor Unit with epoxy painting (Platform stand)
Supply of Anti corresive coating for outdoor & indoor unit as per OEM approved make.
Supply of hot dip galvanised perforated cable trays with cover (600 x 100)mm
Supply of hot dip galvanised perforated cable trays with cover (150 x 100)mm
Electrical Work
Supply of MCB Isolator enclosure(wheather proof box) - For Outdorr Unit
Supply of MCB & ELCB for outdoor unit as per OEM Standard .
Supply of Power cable from panel to outdoor isolator and unit.(4 Core x 6 Sq mm copper armoured XLPE Cable/ as per OEM Standard)
CONTROLLER : Supply of Central Controller for controlling all the indoor and outdoor units and should be capable of integration with BMS system. All the outdoor/indoor unit parameters shall be integrated through BMS & required hardware/software to be included via Modbus/Bacnet. Standard Installation, Testing & Commissioning Charges for VRV
For VRV Outdoor Units (10 HP)
For Hi-wall AC Unit ( 2TR)
For Hi-wall AC Unit (1.5TR)
For Cassette Unit ( 4TR)
For Cassette Unit ( 3TR)
Refnets Joints (insulated with aerotape)
Installation of Refrigerant Control "Y" / "Tee" joints with insulation for piping (Refnets)
Refrigerant Piping
Installation of Copper Refrigerant Suction line as per OEM Standard with 19 mm or better thick rubber nitrile tubular insulation.
Installation of Copper Refrigerant Liquid line as per OEM Standard with 19 mm or better thick rubber nitrile tubular insulation.
Control Cabling
Installation of Control Cabling (2 core x 1 Sq. mm copper cable) from Indoor units to Outdoor units with hard PVC Conduit including cable required from outdoor unit to Central Controller.
CONTROLLER: Installation for Central Controller for controlling all the indoor and outdoor units and should be capable of integration with BMS system. All the outdoor/indoor unit parameters shall be integrated through BMS & required hardware/software to be included via Modbus/Bacnet.
Installation of drain pipes with thermal insulation
25mm or better PVC Hard Pipe
32mm or better PVC Hard Pipe
40mm or better PVC Hard Pipe
Miscellaneous fittings and accessories
Installation of Suspension Rods with cleat angle to hang the indoor units
Refrigerant Charging with R-410 GAS ( or better ) for commissioning of VRV System
Installation of MS Stands for indoor & outdoor units with rubber pads & the frame should be painted hot dip galvanised for outdoor units MS Framework for Outdoor Unit with epoxy painting (Platform stand)
Lifting, Shifting and location for outdoor unit , indoor unit and other accessories (without considering crane).
Installation of Anti corresive coating for outdoor & indoor unit as per OEM approved make.
Installation of hot dip galvanised perforated cable trays with cover : (600 x 100)mm
Installation of hot dip galvanised perforated cable trays with cover : (150 x 100)mm
Civil Work - Civil works includes wall cut out & Core cutout and finishing with same material to run the refrigerant pipes, power cables & cable trays etc., floor tail alignment, cutting, cleaning etc. and any other civil works requried for commissioning of new VRV System.Vendor Should ensure minimal civil work in the best possible way for completion of job.
Electrical Work
Electrical works for proposed inrow cooling units including works of tapping from existing panels, split panels, breakers, cables, cable trays with support and other accessories to complete the system.
Installation of MCB Isolator enclosure(wheather proof box) - For Outdorr Unit
Installation of MCB & ELCB for outdoor unit as per OEM Standard .
Installation of Power cable from panel to outdoor isolator and unit.(4 Core x 6 Sq mm copper armoured XLPE Cable/ as per OEM Standard)
Other Important Work
Dismentaling of Existing VRV System
Project Management and Governance
Comprehensive VRV for above VRV works
2nd year and 3rd Year Comprehensive AMC after 1 year standard warranty
Buy Back Price
Buyback of Existing VRV System( 6 Outdoor Unit , 17 Indoor Units )
ANSHUTECH AIRCONDITIONING PVT LTD
SNOWMEX REFRIGERATION
AQUA COOL CO PVT LTD
Hewlett Packard Enterprise India Private Limited
ANSHUTECH AIRCONDITIONING PVT LTD
SNOWMEX REFRIGERATION
AQUA COOL CO PVT LTD
Hewlett Packard Enterprise India Private Limited
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .