Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.9 LAccepted-AOC FLAT NO 06 BLDG NO B 2 PLEASANT PARK WANWADI PUNE 411040 | PUNE | MAHARASHTRA | 411040 | L1 | Accepted-AOC being lowest tenderer | |
| 2 | L2₹48.0 L+₹2.0 L (4.42%)Rejected-Finance | L2 | Rejected-Finance NOT BEING LOWEST | |
| 3 | L3₹48.9 L+₹2.9 L (6.42%)Rejected-Finance | L3 | Rejected-Finance NOT BEING LOWEST | |
| 4 | L4₹51.0 L+₹5.0 L (10.9%)Rejected-Finance | L4 | Rejected-Finance NOT BEING LOWEST |
Tender Value
₹50.0 L
EMD Value
₹99,900
Closing Date
17 Mar 2025, 6:00 pmClosed
Garrison Engineer Airforce Lohegaon
GE Airforce Lohegaon
SPL REPAIRS TO BER COOLING APPLIANCES PROVISION OF ISOLATION TRANSFORMER FOR RT CABIN AND TRANSMITTER WATER SUPPLY PIPE LINES AT VARIOUS LOCATIONS AT AFS PUNE UNDER GE AF LOHEGAON
2025_MES_698290_1
8853
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE Airforce Lohegaon
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE Airforce Lohegaon
₹99,900
Yes
7 Apr 2025
17 Feb 2025
24 Mar 2025
17 Feb 2025
17 Mar 2025
3 Mar 2025
Amount
Supply and installation hi wall splite unit indoor & outdoor single phase unit 220V to 240 V, 50 Hz of capacity compete with cordless remote control unit and with minimum 5 Star rated and EER 3.2 of capacity 1.5 TR having dual rotor inverter compressor , 100% copper IDU & ODU, installation kit with copper supply & return pipe of length upto 3 mtr, connection eclect cord, drain water pipe of length as per site requirement and incl MS stand for outdoor unit fixing and core cutting in stone masonary wall if required for passing of refrigerant piping and cable etc and making good disturbed surface matching to existing complete all as specified and directed Note :- Copper pipe, electric cord, drain water pipe of length beyond - 3 mtr will be measured & paid seperately.
Supply and installation hi wall splite unit indoor & outdoor single phase unit 220V to 240 V, 50 Hz of capacity compete with cordless remote control unit and with minimum 5 Star rated and EER 3.2 of capacity 2 TR having dual rotor inverter compressor , 100% copper IDU & ODU, installation kit with copper supply & return drain water pipe of length upto 3 mtr, connection eclect cord, and incl MS stand for outdoor unit fixing and core cutting in stone masonary wall if required for passing of refrigerant piping and cable etc and making good disturbed surface matching to existing complete all as specified and directed Note :- Copper pipe, electric cord, drain water pipe of length beyond - 3 mtr will be measured & paid seperately.
Supply and installation hi wall splite unit indoor shall be of 02 Nos unit each of cap 1.5 Ton & outdoor single phase unit 220V to 240 V, 50 Hz of capacity compete with cordless remote control unit and with minimum 3 Star rated and EER 3.2 of capacity 3 TR having dual rotor inverter compressor , 100% copper IDU & ODU, installation kit with copper supply & return pipe of length upto 3 mtr, connection eclect cord, drain water pipe of length upto 3 mtr and incl MS stand for outdoor unit fixing and core cutting in stone masonary wall if required for passing of refrigerant piping and cable etc and making good disturbed surface matching to existing complete all as specified and directed Note :- Copper pipe, electric cord, drain water pipe of length beyond - 3 mtr will be measured & paid seperately.
M&L for taking out the existing unsv split/window type AC any capacity & deposit to E/M store yard for further disposal , including making good to the disturbed surface matching to esisting specifications complete all as specified & directed
M&L for fixing copper tubing 5/8" dia including insulation complete all as specified and directed.
M&L for fixing copper tubing 3/8" dia including insulation complete all as specified and directed.
M&L for fixing copper tubing 1/2" dia including insulation complete all as specified and directed.
M&L for fixing copper tubing 1/4" dia including insulation complete all as specified and directed.
M/L for sub main wiring with two runs of single core 4.0 Sq mm FRLSH PVC insulated unsheathed multi stranded copper conductor 1100 V grade with colour code and one run of 4 Sq mm single core FRLSH PVC insulated unsheathed multi stranded copper conductor green colour cable as earth continuity conductor drawn in & including casing & caping complete all as specified and as directed. Add Note:- Two runs of 4 sqmm copper cable and one run of 4 sqmm copper cable including PVC casing & capping shall be measured and paid as one length.
S&F multi stranded copper conductor core flexible copper conductor PVC insulated and sheathed cable, 1100 Volts, 4 sqmm x 4 core & including casing caping complete all as specified and directed.
M&L for fixing drain flexible PVC pipe of size 12/15 mm for split type AC complete all as specified and directed.
M&L for Sheet metel enclosure with single pole and neutral with two pin and earth plug and socket complete with one single pole MCB 20 Amps, 240 volt complete all as specified and as directed.
Supply, installation, commissioning of water cooler, fully stainless steel, electric driven single phase having approx storage capacity of 120 ltrs and normal cooling capacity of 60 ltrs per hours including connection pipe & accessories of length upto 2 mtr complete all as specified and as directed.
Supply, installation, commissioning of water cooler, fully stainless steel, electric driven single phase having approx storage capacity of 80 ltrs and normal cooling capacity of 40 ltrs per hours including connection pipe & accessories of length upto 2 mtr complete all as specified and as directed.
Supply, installation, commissioning of water cooler, fully stainless steel, electric driven single phase having approx storage capacity of 150 ltrs and normal cooling capacity of 150 ltrs per hours including connection pipe & accessories of length upto 2 mtr complete all as specified and as directed.
M&L for point wiring for 3 pin socket outlet, 15 amps, independent, with PVC sheathed multistranded copper conductor cables cables 2.5 sqmm size in PVC casing & caping with accessories PVC box ISI marked etc. complete all as specified and as directed.
Supply and fix switch socket combination outlet 2 in 1, 3 pin, 5 & 15 Amp flush type complete all as specified and as directed.
Supply, lay & jointing tubing heavy grade galavanised iron pipes, ISI marked with all fittings such as bends, tees, elbows, nipples, unions, short pieces, sockets etc fixed to walls ceilings or laid on floors/roof etc all as specified of size 80mm complete all as specified and as directed.
Supply, install, testing and commissioning of Pump set electrically driven horozontal end suction, centrifugal type confirming to IS-12469:1988 with CI casing, bronze impeller and stainless steel shaft mounted on heavy duty bearings suitable for continuous operation with range of operation 0% to 150% of rated capacity motor 440V, 3 Phase, 50 Hz 40 m head and 1100 lpm disharge including starter of suitable type and capacity complete all as specified and as directed. The item includes (i) Suction pipes of dia as specified by manufacturer to a length not more than 9 metres and delivery pipe of dia as specified by manufacturer to a length not more than 6 metres. Note: The item includes the cost of suction and delivery pipe, PCC foundation, cover to protect motor from water/rain labour & transportation cost & nothing shall be paid extra on this account
Supply & Fixing, Gun Metal Single outlet type fire hydrant landing valve type B ISI marked of size 63 mm dia complete with brass spindle cast iron wheel and instantaneous coupling ISI marked confirming to IS 5290 hydrostatic test pressure 23kg/cm2, minimum opearting pressure 7 Kg//cm2 complete all as specified and as directed.
Supply & Fixing Hose Box outdoor type made of 18 gauge MS Sheet 80cm x 60cm x 25cm with double door with 4 mm thick glasses and door frame made of 16 gauge MS sheet painted fire red outside and briliant white inside yard complete all as specified and as directed.
Supply & Fixing hose reel drum 63mm dia 15 metre long hose canvas cofirming to IS 636 complete with male and female coupling confirming to IS 903 complete all as specified and as directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m height in depth for laying of GI tubing and getting out in soft/ loose Soil complete all as specified and as directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m height in depth for laying of GI tubing and getting out Hard/ Dense Soil complete all as specified and as directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m height in depth for laying of GI tubing and getting out Soft disintegrated soil complete all as specified and as directed.
Returning filing in including spreading levelling watering and well ramming in layers n. exc. 25 cm with soil obtained from excavation complete all as specified and as directed.
Removing excavated soil / material n. exceeding 50 mtr and depositing where directed at level n exc 1.5 mtr above the startig point complete all as specified and as directed.
Supply and laying in trench / fixing in wall /poles/ducts LT 1100 Volts XLPE armoured copper cable cable 10 Sqmm 4 core complete all as specified and as directed.
Supply & Fixing non return Butterfly Valve of Size 80 mm flanged end type complete all as specified & directed.
Supply & Fixing foot Valve of size 100mm or suitable for item No 02 Flanged end/ any type complete all as specified & directed
M&L for cutting of existing road not exceeding 1.5 mtr in depth and n exc 1.5 m wide including black top, sub base and WBM, well ramming in layers with watering after laying of RCC / GI pipe under road making good in all respect to match the existing surface by PCC complete all as specified and as directed.
Material only for Brick protection covers laid over cables of sub calss 'B' bricks old size (230x115x75)mm complete all as specified and as directed.
Material only for stone dust sand cushioning to underground cable, provided with a layer 8 cm before and 15cm after laying & stretching jointing and testing the cable complete all as specified and as directed.
Supply, Fixing , Testing and Commissioning of Three phase isolation transformer of capacity 15 KVA with the following specification : Three phase ,50 Hz , indoor , Copper wound , oil cooled , class of insulation A ,metallic body duly powder coated designed for input Voltage range 415+-5% and output voltage range 415+-5% ,Ratio 1:1 , Vector Group :Dyn 11, Delta- star with first filling of transformer oil of requisite dielectric strength up to level , efficiency more than 95 % , separate neutral bushing shall be brought out for earthing. Potential difference between neutral to earth less than one volt with all standard fittings like digital temperature meter , adequate number of cooling radiators , lifting hooks one set , Earthing terminal two nos complete . Testing as per BIS 9815 and 2026 with all standard fitting as per direction of Engineer in charge
Supply, Fixing , Testing and Commissioning of Three phase isolation transformer of capacity 5 KVA with the following specification : Isolation transformer , single phase ,50 Hz , Copper wound , Air cooled , class of insulation A ,metallic body duly powder coated designed for input Voltage range 240+-5% and output voltage range 240+-5% ,Ratio 1:1 , indoor , efficiency more than 95 % , Potential difference between neutral to earth less than one volt with all standard fittings complete all as specified and as directed.
S & F Sub Main Wiring with FRLS PVC Insulated multistranded copper conductor wires of size 2x6.0 sq. mm + 1x6.0 sq. mm earth wire in casing caping complete as directed.
Supply and laying in trenches or fixing to wall/pole/ducts or passing through pipe PVC insulated heavy duty electric cable with Armoured Copper conductor 1100 volts grade cross sectional area 10 Sqmm 4 core. complete all as specified and as directed.
Supply and fix ON LOAD change over switch 415V in sheet metal enclosures 4 pole of capacity 63 Amps complete all as specified and as directed.
Supply & Fix 25 Amp Dual Pole MCB Type Change Over Switch | 2 Pole C Curve MCB complete all as specified and as directed.
S & F sheet metal enclosure DB 2 Way Single Door din rail type complete all as specified and as directed.
M/L for providing earthing complete with Copper earth plate electrode 600 mm x 600 mm x 3.15 mm thick buried directly in ground earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level connected to copper earth strip 20 x 3 mm by means of bolts, nuts, checknuts & washers of copper and connecting to test point , providing charcoal and common salt ,all as shown in electrical plate No. 3 of SSR Part I of 2009 & as specified or indicated and testing on completion including excavation/earth work in any type of strata PCC ( 1:3:6 ) type C1 earthing chamber, pre cast slab 50 mm thick in cement concrete ( 1: 2 : 4 ) type B1 (reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg / Sqm), funnel with wire mesh, watering pipe of 20 mm bore medium grade and lugs, including copper earth strip 20 x 3 mm , 7.5 meter long, etc complete all as specified and directed. Note- (i) Excavated material to be removed from the site and deposit at the distance not exceeding 50m distance and levelled. (ii) Refill the pit with black cotton soil. (M&L for black cotton soil must be included in the quoted rate)
S& F Earth continuity conductor or main earthing lead of Size 20 mm x 3 mm Coper STrip fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required
DARSHAN CONSTRUCTION Co. (BID ID -3259615)
Maruti Abhiyantriki (BID ID -3264898)
somnath engineering corporation (BID ID -3259312)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .