Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.6 LAccepted-AOC | ₹29.6 L Quoted ₹30.1 L | L1 | Accepted-AOC Being lowest |
| 2 | L2₹32.5 L+₹2.4 L (7.82%)Rejected-Finance 47A C3 OLD DAMU NAGAR PULIAKULAM COIMBATORE 641 045 | COIMBATORE | COIMBATORE | TAMIL NADU | 641045 | ₹32.5 L+₹2.4 L (7.82%) | L2 | Rejected-Finance Not being lowest |
| 3 | L3₹35.9 L+₹5.8 L (19.1%)Rejected-Finance 27 WESTERN STREET ROOM NO 307 KOLKATA 700012 WEST BENGAL | KOLKATA | KOLKATA | WEST BENGAL | 700012 | ₹35.9 L+₹5.8 L (19.1%) | L3 | Rejected-Finance Not being lowest |
| 4 | L4₹35.9 L+₹5.8 L (19.2%)Rejected-Finance | ₹35.9 L+₹5.8 L (19.2%) | L4 | Rejected-Finance Not being lowest |
| 5 | L5₹36.4 L+₹6.3 L (21.0%)Rejected-Finance NEAR CENTRAL SCHOOL BALASORE DIST BALASORE ORISSA 756 001 | BALASORE | BALASORE | ORISSA | 756001 | ₹36.4 L+₹6.3 L (21.0%) | L5 | Rejected-Finance Not being lowest |
Tender Value
₹32 L
EMD Value
₹64,000
Closing Date
1 Aug 2022, 6:00 pmClosed
GE I R and D Chandipur
GE I R and D Chandipur, Post- Chandipur, PIN-756025
REPAIR MAINTENANCE OF LT CABLES NETWORK LT PANELS FEEDER PILLARS AND ALLIED WORKS AT ITR CHANDIPUR
2022_MES_537578_1
8729/CDP
Open Tender
Civil Works
Item Rate
180 days
Chandipur
As per tender documents
8 documents required · 8 mandatory
₹500
GE I R and D Chandipur
₹64,000
Yes
21 Oct 2022
12 Jul 2022
3 Aug 2022
12 Jul 2022
1 Aug 2022
26 Jul 2022
Amount
NOTE (Applicable for all items) :- The bidders/contractors are advised to read tender document & all corrigendum / amendments and General conditions of contracts before entrying/quoting the rates.
Repair to LT ACB of capacity 800/1000 amps by disconnecting from the busbar and replacing all unserviceable parts of finger contact with male female set and wiring with new copper conductor cable of 2.5 sq mm . Replacing the U/S mechanical spring system , fixed and moving contacts, replacement of bearing of spring charge motor and rewinding of control transformer with super enameled copper wire of gauge and replacement of FRCD (free return charge device) all connected work including require at site for proper and smooth functioning of air circuit breaker all as specified and directed.
S & F in repair MCCB, 4 pole, 630 Amps, 415 Volts , 36 KA adjustable thermal and magnetic setting complete all as directed by Engineer-in-Charge including taking down old and unserviceable one.
All as per Sl Item No 2 here-in-before but of rating 400 Amps, 36 KA complete all as directed.
All as per Sl Item No 2 here-in-before but of rating 250 Amps, 36 KA complete all as directed.
S & F in repair MCCB, 4 pole, 200 Amps, 415 Volts , 36 KA adjustable thermal and magnetic setting complete all as directed by Engineer-in-Charge including taking down old and unserviceable one.
All as per Sl Item No 5 here-in-before but of capacity 100 Amps 4 pole, 25 KA.
All as per Sl Item No 5 here-in-before but of capacity 63 Amps 4 pole, 25 KA.
M & L for cleaning of LT panels , and bus bar Chamber and replacement of burnt/damaged busbar of aluminium of existing size including disconnecting and taking down LT cable of any size , Re-fixing of same after carrying out the repair and replacement of cable lugs/thimble and replacement of locking arrangement/sliding bolts, knobs and rubber beading capacity including applying two coat of synthetic enamel paint and writing the location (Incoming/outgoing) using white synthetic enamel paint as direted by Engr-in-charge complete all as specified.
Supply only Digital VAF+PF Meter suitable for 3Ph VAF + PF display, Class 1, 5A.
Supply only Amp meter Digital type 0-500 Amp.
Supply only LED phase indicaton lamp (RYB) complete all as specified and directed.
Supply only Current transformer of Ratio 100/5 to 250/5 Amps
Supply only Current transformer of Ratio 400/5 to 800/5 Amps
Excavation in trenches in soft/loose soil n.exc 1.5m wide and n. exc 1.5m depth for laying of cable, errection of poles, stay and pipe line,and getting out complete all as specified and as directed.
Returning & filling including spreading, leveling watering and well ramming in layers n. exc 25 cm thick in any type of soil complete all as specified.
Removal of excavated soil to a distance n. exc 50 m above the starting point complete all as specified and directed
M&L for laying of bricks locally available sub class 'B' bricks (old size) for cable protection cover laid flat and dry in trenches over the cable prependicular to the direction of cable all as directed.
M&L for local sand coushioning with dry and clean over and under the cable for protection of cable , 80 mm sand laid before laying the cable 150 mm sand after laying the cable and filling the sand in cable duct of inside the sub station building complete all as directed
Taking out old unserviceable LT UG cables of size 10 to 95 Sq mm 3.5/4 Core from trenches, poles/walls/culverts and floor including taking out old unserviceable/serviceable bricks covers /GI pipe of any size from trenches for removing including re-laying cable (after necessary repair/jointing with new cable) the cable all as directed (New bricks/sand use for laying shall be paid separtly as per ground measurement)
All as per Sl Item No 21 here-in-before but of size 120 to 300 Sqmm 3.5 core complete all as specified and directed.
Supply and Laying XLPE LT UG cable PVC insulated , bedded armoured heavy duty electric cable 1100 volts grade with aluminum conductor of size 10 Sqmm 2 Core laid in trenches or fixed on wall/floor/poles complete all as specified and directed.
All as per Sl Item No 23 here-in-before but of size 25 Sqmm 4 core complete all as specified and directed.
All as per Sl Item No 23 here-in-before but of size 35 Sqmm 3.5 core complete all as specified and directed.
All as per Sl Item No 23 here-in-before but of size 50 Sqmm 3.5 core complete all as specified and directed.
All as per Sl Item No 23 here-in-before but of size 95 Sqmm 3.5 core complete all as specified and directed.
All as per Sl Item No 23 here-in-before but of size 185 Sqmm 3.5 core complete all as specified and directed.
All as per Sl Item No 23 here-in-before but of size 300 Sqmm 3.5 core complete all as specified and directed.
M & L Cutting of grass/bushes surounding the area of substation/out door type feeder pillar box /4 pole stracture and remove the deposited materials to a distance not more than 50 mtr sway from the site including cleaning the out side and inside of the sub station building and making the surface gradualy smooth and cleen complete all as specified and directed.
M&L for drilling suitable dia horizontal bore holes for insertion / laying of 50/100 mm bore GI tubing of any description below/under road surface/floors etc with using mechanical or manual devices as required at site including making good disturbed surface to match with the existing streta after laying pipes complete all as specified and directed.
Supply and fixing of GI tubing light grade of 80 mm dia for cable protection on pole/wall/floor/ or in trenches and drain etc complete with necessary clamp, nut, bolts and washers and socket and making good the disturbed surface of wall , floor or roof etc all as specified and directed.
All as per Sl Item No. 32 here-in-before but of dia 50 mm complete all as specified and directed
M&L for jointing kit suitable for LT 1100 Volts cable (earthed) for out door straight through joint , heat shrinkable type complete with jointing material and accessories suitable for 25 to 50 Sqmm 3.5 core XLPE armoured aluminium conductor cable complete all as specified and directed.
All as per Sl Item 34 here-in-before but suitable for size 70 to 150 Sqmm 3.5 core cable complete all as specified and directed
All as per Sl Item 34 here-in-before but suitable for size 185 to 300 Sqmm 3.5 core cable complete all as specified and directed
M&L Bus Bar Panel of capacity 200 Amps copper bus bar 04 Nos with fixed on insulator welded with iron angle of size 50x50x6 mm thick grounting in floor , 0.45 mm depth grounting with PCC 1:3:6 upto ground level all as specified and directed. Make- SHI/SHALABH/Havells
M&L Bus Bar Panel of capacity 100 Amps copper bus bar 04 Nos with fixed on insulator welded with iron angle of size 45x45x5 mm thick grounting in floor , 0.45 mm depth grounting with PCC 1:3:6 upto ground level all as specified and directed.
M&L for prepration of old painted surface of LT panel board /Bus Bar boxes etc and applying one coat of synthetic enamel paint over of one coat of redoxide primer with spray machine at LC-III area complete all as specified and as directed.
supply and replace door of out door LT pannel made out of CRCA Sheet 3.15mm thick bend on side to match the existing door duly powder coated and with new hinges -2 nos to suit any size / shap of pannel including welding/cuttinng etc all as specified and as directed.
S & F in replacement Manual Changeover Switch in sheet steel Enclosure with extended handle of capacity 200 Amps, 4 pole, 415 Volts, 50 HZ including fixing on wall by means of grouting bolts and connecting cable with suitable lugs/thimbles complete all as specified and directed.
S & F in replacement On Load Changeover Switch in open execution extended handle of capacity 200 Amps, 4 pole, 415 Volts, 50 HZ including fixing on wall by means of grouting bolts and connecting cable with suitable lugs/thimbles complete all as specified and directed.
Supply and erecting in replacement of Prestressed concrete pole, 9.0 metres long, 102mm x 172mm at topand 102mm x 279mm at bottom,class 10 including taking down old us pole complete all as specified and directed.
M& L for cement concrete PCC(1:2:4) type B1 using 20mm graded aggregate as in pole coping complete all as specified
M& L for cement concrete PCC(1:3:6) type C2 using 40mm graded aggregate as in foundation of pole complete all as specified
M& L for cement concrete PCC(1:4:8) type D2 using 40mm graded aggregate as in mass filling of pole complete all as specified
S & F in replacement of switch for LT panel type FN 250 A TPN , 4 pole, 415 Volts, 50 HZ including taking down old switch and connecting cable with suitable lugs/thimbles complete all as specified and directed.
S & F in replacement of HRC fuse for LT panel type HN 250 A size 1, SF942330000, 4 pole, 415 Volts, 50 HZ including taking down old fuse and connecting cable with suitable lugs/thimbles complete all as specified and directed.
M& L for Earthing complete with galvanised steel earth plate eletcrode of size 60 cm x 60 cm x 6.0 mm thick electrode as buried directly in ground (earth pit not less than 3 m below normal ground level connected to GI earth strip 32mm x 6mm thick by means of bolts nuts,check nuts and washers at complete etc all as shown in electrical plate No-3 of SSR part-1 connected to earthing test point all as specified or indicated including PCC pit in PCC(1:3:6) type CI cast iron frame 50mm thick pre cast RCC (1:1½ :3) nominal mix cover slab reinforced with 8mm dia mild steel bar including necessary excavation earth work in soft/loose soil and disposal of spoil to a distance n.exc 50mtr and funnel with watering pipe wire mesh GI protection pipe 40mm bore including testing complete including taking out old us earthing material all as specified and directed. Note - Earthing lead and GI protection pipe beyond 7.5 mtr shall be measured and paid deparately.
(vii) CT (400/5A) -03 Nos (C) OUTGOING :- (i) 4 pole MCCB of capacity 100 Amp, breaking capacity 25 KA with thermal magnetic release adjustable type - 02 Nos. (ii) 4 pole MCCB of capacity 63 Amp, breaking capacity 25 KA with thermal magnetic release adjustable type - 07 Nos. (iii) 4 pole MCCB of capacity 32 Amp, breaking capacity 16 KA with thermal magnetic release adjustable type - 02 Nos. (iv) On Load Changeover Switch in open execution extended handle of capacity 250 Amps, 4 pole, 415 Volts, 50 HZ including fixing with LT panel and connecting cable with suitable lugs/thimbles complete all as specified and directed.-01 No
(vii) CT (400/5A) -03 Nos (C) OUTGOING:- (i) 4 pole MCCB of capacity 100 Amp, breaking capacity 25 KA with thermal magnetic release adjustable type - 03 Nos. (ii) 4 pole MCCB of capacity 63 Amp, breaking capacity 25 KA with thermal magnetic release adjustable type - 03 Nos. (iii) 4 pole MCCB of capacity 32 Amp, breaking capacity 16 KA with thermal magnetic release adjustable type - 03 Nos.
KRISHNA ENTERPRISES
ELECTRO COMMERCIAL CO
Rekha Enterprises
M/S T.N.CONSTRUCTION
M/s R.C REFRIGERATION
jlenterprise
DS ENTERPRISES
chauhan syndicate
Bidder Name
DS ENTERPRISES
KRISHNA ENTERPRISES
M/s R.C REFRIGERATION
MS SHIVA DURGA ENTERPRISES
chauhan syndicate
Rekha Enterprises
M/S T.N.CONSTRUCTION
ELECTRO COMMERCIAL CO
jlenterprise
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .