| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.9 LAccepted-AOC | ₹28.9 L Quoted ₹29.5 L | L1 | Accepted-AOC ACCEPTED |
| 2 | L2₹29.8 L+₹26,100 (0.88%)Rejected-Finance 1001 63 SHALIMAR GARDEN ISMAILGANJ NEAR INDIRA NAGAR SECTOR 08 CROSSING LUCKNOW 226016 | LUCKNOW | UTTAR PRADESH | 226016 | ₹29.8 L+₹26,100 (0.88%) | L2 | Rejected-Finance HIGHER BID VALUE |
| 3 | L3₹35.5 L+₹6.0 L (20.2%)Rejected-Finance | ₹35.5 L+₹6.0 L (20.2%) | L3 | Rejected-Finance HIGHER BID VALUE |
| 4 | L4₹36.0 L+₹6.5 L (21.9%)Rejected-Finance KHABAM CHUMRIETHONG NEAR IGAR SOUTH P O MATRIPUKHRI IMPHAL 795002 | IMPHAL | IMPHAL WEST | MANIPUR | 795002 | ₹36.0 L+₹6.5 L (21.9%) | L4 | Rejected-Finance HIGHER BID VALUE |
| 5 | L5₹37.2 L+₹7.6 L (25.9%)Rejected-Finance | ₹37.2 L+₹7.6 L (25.9%) | L5 | Rejected-Finance HIGHER BID VALUE |
Tender Value
₹30.9 L
EMD Value
₹61,800
Closing Date
23 Jan 2020, 6:00 pmClosed
GE 869 EWS
GE 869 EWS C/o 99 APO Pin-913869
SPECIAL REPAIRS TO LT OVERHEAD LINES UG CABLE AND CONNECTED WORKS, REPLACEMENT OF ELECTRIC WATER HEATER (GEYSER) AGAINST BER, PROVN OF LIGHTENING CONDUCTORS FOR UG STORAGE TANKS OF 06X20KL DHPP(N), 01X20KL 87MT GAS, 01X15KL, 02X20KL SKO AND CERTAIN
2019_MES_293240_1
8251/E8
Open Tender
Civil Works
Item Rate
270 days
LEIMAKHONG
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
GE 869 EWS
₹61,800
Yes
6 Mar 2020
2 Jan 2020
25 Jan 2020
2 Jan 2020
23 Jan 2020
16 Jan 2020
Amount
E/M work
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, poles struts, etc., not exceeding 10 Sqm on plan and laying of cables or pipes, not exceeding 1.5m in depth and getting out in hard/dense soil complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm as in soils complete all as specified and as directed.
Removing excavated materials to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5 mtr above the starting point as in soils complete all as specified and as directed.
Supply and spread sand in trenches as sand cushioning to underground cable for protection with dry fine river sand and provide required cover after punning down complete all as specified and directed. (Note: Thickness of sand cushion after punning down will be measured and paid.)
Supply and laying well burnt sub class ‘B’ bricks (designated 75) locally available best quality, laid dry in trenches for protection of underground cable all as specified and directed.
Dismantling of unserviceable Steel tubular poles/struts, any size including removal from site complete all as directed.
Erecting & fixing only of steel tubular swaged poles, type 410 SP 31 (Overall length 9.00 m) complete with cast iron base plate, finial taper plug, bolts, nuts screws and washers including cleaning, scrapping, preparaing old painted surface & painting two coats of black bituminous paint internally and externally up to planting depth and remaining external portion with two coats of aluminum paints over a coat of red oxide primer incl painting black and white alternate strips of 30cm each from ground level up to 1.5 meter and writing pole Nos with white paint on black back ground complete all as specified and as directed. (NOTE: Steel tubular pole will be issued under Schedule 'B' free for fixing)
M&L for PCC 1:4:8, type D2 using 40mm graded crushed stone aggregate as in foundation of pole, protection of UG cable, concrete base, etc complete all as specified and directed.
M&L for PCC M-10 grade using 20mm graded coarse stone aggregate in coping of pole, concrete base work, protection of cable complete all as specified and directed.
Taking up/down worn out/ damaged / unserviceable XLPE/ PVC insulated underground cable armoured, heavy duty with aluminium conductors of any size, 1100V grade from trench/ duct/ pole/ wall/ pipes/ roof tops etc. complete all as specified and directed.
Supply, laying, jointing and connecting, LT UG cable XLPE insulated , PVC bedded , galvanised steel strip or wire armoured, electric power cable ( heavy duty) 1100 volts grade with stranded aluminium conductor of size 10sqmm 2 core ,laid in trenches / on poles / walls / in ducts / passing through pipes etc including jointing materials such as cable glands, lugs etc complete all as specified and as directed.
All as per serial item No. 12 above but for 16 Sqmm 4 Core.
All as per serial item No. 12 above but for 25 Sqmm 3.5 Core.
All as per serial item No. 12 above but for 70 Sqmm 3.5 Core.
Supply and laying 25mm bore GI tubing light grade as in cable protection pipe including all fittings complete all as specified and directed.
Supply and laying 40mm bore GI tubing light grade as in cable protection pipe including all fittings complete all as specified and directed.
Dismantling of unserviceable worn out / weathered / damaged ACSR conductor, service feeder of any size and type from pole after disconnecting jumpers and insulator bindings complete all as specified and directed.
M&L for ACSR conductor of any size including all binding wires and aluminium jointing, jumpers etc maintaining standard sag on LT lines complete all as specified and directed
Restringing, tightening of existing ACSR conductor of any size and type and GI continuous earth conductors of any size, maintaining standard sag including providing aluminum binding wire on LT over head lines complete all as specified and directed.
Dismantling rusted/damaged cross arm of MS channel or angle section from pole complete all as specified and directed.
M & L for cross arms, bracing, clamps and back plates fabricated from structural steel section including nuts, bolts, washers etc, drilling hole for bolts in any shape or size with welding, bending cold or hot including painting two coats of aluminium paint over a coat of primer complete all as specified and directed. (Confirming to Fe-209, Gde- E.165)
Dismantling damaged insulators of any type and any size complete all as directed.
S&F pin type porcelain insulator of size 100 mm height, 65mm dia, vitreous, white, brown or green including one galvanized mild steel spindle, two galvanized iron washer and one galvanized iron nut for 1100 volts grade complete all as specified as directed.
S&F shackle type insulator, porcelain, vitreous, white, brown or green, 75mm height 90mm dia for working pressure of 1100 volts including galvanized steel straps of section 31x3mm, 12mm dia of bolts, washers and nuts complete all as specified and directed.
Supply and fix loop type insulator, vitreous porcelain, white, brown or green small size, with overall dimensions 65 x90mm, clearance of hole 16mm complete all as directed.
Material and labour for cutting of road/ hard standing n exc 20cm width and n exc 60cm in depth for laying of cable protection pipe including making good the disturbed road/hard standing by providing PCC (1:2:4) type B1 to match with existing surface complete all as specified and directed.
M&L for cleaning, scrapping, preparing old painted steel tubular pole 9m long and applying one coat of aluminium paint to pole and accessories / fittings whatever fixed on pole including marking pole No on each pole with yellow SE paint with 5cm large bold letters on black background of suitable size at a height of 2m above GL and painting 50mm wide coloured alternate strips of yellow and black with 2 coats of synthetic enamel paint upto a height of 1.5m from coping of pole complete all as specified and directed.
Trimming / cutting of the tree branches / bushes which falls within a clear distance of 3 meter from all sides from the HT / LT over head conductor & within line of conductors, and shifting waste to nearby waste depot & cleaning the area complete all as directed. (Note :- Tree branches/Bushes falling on both sides of OH lines per metre run of OH lines shall be measured for the purpose of payment)
Dismantling and disconnecting of old unserviceable Burnt MCCBs of any capacity complete all as directed.
S&F MCCB 4 pole, 415 V, adjustable type 160 Amp with breaking capacity 25KA complete all as specified and directed. (Make: Havells Cat No. IHLANF0160 or equivalent in Legrand/Schneider/ ABB/Seimens)
S&F MCCB 4 pole, 415 V, adjustable type 200 Amp with breaking capacity 25KA complete all as specified and directed. (Make: Havells Cat No. IHLANF0200 or equivalent in Legrand/Schneider/ ABB/Seimens)
S&F MCCB 4 pole, 415 V, adjustable type 250 Amp with breaking capacity 25KA complete all as specified and directed. (Make: Havells Cat No. IHLANF0250 or equivalent in Legrand/Schneider/ ABB/Seimens)
S&F MCCB 4 pole, 415 V, adjustable type 400 Amp with breaking capacity 36KA complete all as specified and directed. (Make: Havells Cat No. IHLLSEBF0400 or equivalent in Legrand/Schneider/ ABB/Seimens)
S&F MCCB 4 pole, 415 V, adjustable type 630 Amp with breaking capacity 36KA complete all as specified and directed. (Make: Havells Cat No. IHLLSEBF0630 or equivalent in Legrand/Schneider/ ABB/Seimens)
Taking down old unserviceable service cable including batten/ suspending wires complete all as specified and directed.
S&F Service wire connection with one twin core 10 sq mm, 2 core, 1100 volts grade heavy duty flat or circular cable, multi stranded aluminium conductor, PVC insulated served with inner sheathing of PVC tape armoured, suspended by insulating hangers not more than one mtr apart incl 4mm dia GI suspension wire complete all as specified and directed.
Dismantling stay assembly complete all as directed
M&L for stay assembly 20 mm dia complete with accessories as shown in electrical plate No. 1 complete all as specified and directed. (Note : Loop type insulator, stay clamps, excavation and concrete shall be measured separately)
M&L for galvanized stay strand of size 7/3.15 mm complete all as specified and directed.
M&L for Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size including taking down old damaged plate complete all as specified and directed
M&L for LT line seperator (4 wire in a single seperator) on over head lines complete all as specified and directed.
M&L for earthing complete with galvanized steel plate electrode 600 X 600 X 6 mm thick buried directely in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 mtr below normal ground level connected to GE earth strip of size 25 x 3mm as earthing lead by means of galvanized steel bolts,nuts check nuts and washers and other end connected with to Transformer, DG sets, Pannel board etc as directed including funnel, 20 mm bore, light grade galvanized iron pipe, wire mesh charcoal of coal dust and common salt in alternative layer all around the earth electrode compacted thickness 15cm with concrete pit in PCC 1:3:6 type C1 50 mm thick pre cast RCC 1:2:4 type B1 with 8mm dia cover slab set in CM (1:4) reinforcement with 8mm dia deformed bars @ 15 cm C/C and suitable handle of 10mm dia MS round bars, including earth work as required complete all as shown in electrical plate No. 5 of MES schedule Part I and testing complete all as specified and as directed. (Note: GI Earthing strip upto 7.5m in lenght is deemed to be included in the unit rate. The Strip required beyond 7.5m shall be measured and paid for separately)
M&L for earthing complete with galvanized steel plate electrode 600 X 600 X 6 mm thick buried directely in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 mtr below normal ground level connected to GE earth strip of size 32 X 6mm as earthing lead by means of galvanized steel bolts,nuts check nuts and washers and other end connected with to Transformer, DG sets, Pannel board etc as directed including funnel, 20 mm bore, light grade galvanized iron pipe, wire mesh charcoal of coal dust and common salt in alternative layer all around the earth electrode compacted thickness 15cm with concrete pit in PCC 1:3:6 type C1 50 mm thick pre cast RCC 1:2:4 type B1 with 8mm dia cover slab set in CM (1:4) reinforcement with 8mm dia deformed bars @ 15 cm C/C and suitable handle of 10mm dia MS round bars, including earth work as required complete all as shown in electrical plate No. 5 of MES schedule Part I and testing complete all as specified and as directed. (Note: GI Earthing strip upto 7.5m in lenght is deemed to be included in the unit rate. The Strip required beyond 7.5m shall be measured and paid for separately)
S&F 32 x 6mm GI strip for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. complete all as specified and directed.
S&F 25 x 3mm aluminium strip in repair for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. complete all as specified and directed.
Supply and laying 50mm bore GI tubing light grade as in cable/earth lead protection pipe including all fittings fixed to wall/ceiling or floors complete all as specified and directed.
S&F Air termination, single pointed aluminium rod 12mm dia and 300mm long complete all as specified and directed.
M&L for Test point terminal block made of gun metal or phosphorus bronze size 75 x 75 x 25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified and directed.
Material and labour for point wiring surface type with two single core 2.5 Sq mm (nominal area) FRLS PVC insulated and unsheathed, multi-stranded, copper conductor cable in and including suitable size PVC casing capping with all fittings and fixing accessories and suitable size PVC box for mounting switches, regulator etc including multi-strand PVC insulated unsheathed stranded copper cable as earth continuity conductor of size 2.5 Sq mm complete all as specified and directed for one 5 pin 15 Amps socket out let :- (Colour code to be followed)
Material and labour for point wiring surface type with two single core 4 Sq mm (nominal area) FRLS PVC insulated and unsheathed, multi-stranded, copper conductor cable in and including suitable size PVC casing capping with all fittings and fixing accessories and suitable size PVC box for mounting switches, regulator etc including multi-strand PVC insulated unsheathed stranded copper cable as earth continuity conductor of size 2.5 Sq mm complete all as specified and directed for one 5 pin 15 Amps socket out let :- (Colour code to be followed)
S&F modular socket multipurpose 3 pin 16 Amps and 3 pin 6 Amps combined 2 module complete all as specified and directed.
S&F modular switch piano, 16 Amps, single pole, one way complete all as specified and directed.
S&F GI tubing 15mm bore, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
S & F 15mm bore bib taps, cast copper alloy, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferule complete all as specified and directed.
Drilling and tapping cast iron water mains (in position) for branch connections of 15mm internal dia complete all as specifed and directed.
S&F 15mm bore stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
S&F storage type electric water heater of 25 Ltrs capacity, 240 Volts, rated input 1.5 KW, PUF insulated fitted with stainless inner container and copper coil of BEE rating 5 star model, fixed to wall with suitable MS tower/anchor bolts, inlet/outlet pipe, grouted to wall. (Make :- Jaquar Elena 25 Ltrs or equivalent in Havells/Bajaj/Crompton/Usha)
S&F storage type electric water heater of 50 Ltrs capacity, 240 Volts, rated input 2 KW, PUF insulated fitted with glass lined inner container and copper coil of BEE rating 5 star model, fixed to wall with suitable MS tower/anchor bolts, inlet/outlet pipe, grouted to wall. (Make :- Usha model 'MISTY 50L' or equivalent in Bajaj/CG/Jaquar/Havells)
S&F modular white cover plate with frame of 4 module complete all as specified and directed..
S&F metal exhaust fan AC single phase 230 volts of size 300mm sweep with louvers complete fixed in opening of wall with suitable MS bolts, grouted to wall and connecting up including provision of cable from connector to fan with flexible cable 24/0.2mm with copper conductor and necessary fitting complete all as specified and directed. (Make: Crompton Model No Drift Air 12' or equivalent in Havells/Bajaj/Usha)
S&F ceiling fan, 1200mm sweep, 3 blade with 5 star rated standard super silent motor including provision of 3 core flxible copper conductor cable of size 23/0.19 from ceiling rose to ceiling complete all as specified and directed. (Make: Crompton Model No Entrust 50 or equivalent in Bajaj/Usha/Havells)
S&F wall mounted fan AC single phase 230 volts of size 400mm sweep with louvers complete fixed to wall and connecting up including provision of cable from connector to fan with flexible cable 24/0.2mm with copper conductor and necessary fitting complete all as specified and directed. (Make: Usha Mist air wall or equivalent in Havells/Bajaj/Crompton)
Supply, install, testing and commissioning of metal top deep freezer of capacity 400 Litres, AC, single phase 240V,complete with all fixing accessories all as specified and directed. (Make: Blue Star Model No CHF 400A or equivalent of Voltas/Samsung/LG)
RK Enterprises
M/S N JADUMANI SINGH
SKYLINE CONSTRUCTION
M/S PRADEEP CONSTRUCTION
N THOIBA SINGH
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .