| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.8 LAccepted-AOC | ₹13.8 L | L1 | Accepted-AOC Being lowest |
| 2 | L2₹14.0 L+₹15,342 (1.11%)Rejected-Finance | ₹14.0 L+₹15,342 (1.11%) | L2 | Rejected-Finance Being not lowest |
| 3 | L3₹14.4 L+₹54,003 (3.91%)Rejected-Finance 30 INDUSTRIAL AREA KOKAR RANCHI 834004 JHARKHAND | RANCHI | JHARKHAND | 834004 | ₹14.4 L+₹54,003 (3.91%) | L3 | Rejected-Finance Being not lowest |
Tender Value
₹14.8 L
EMD Value
₹29,500
Closing Date
11 Jul 2024, 6:00 pmClosed
CWE (AF) BAMRAULI
CWE AF BAMRAULI
REPAIR/MAINT OF VCB , RMU, TRANSFORMER , ISOLATION TRANSFORMER , SERVO VOLTAGE STABILIZER AND CONNECTED WORKS AT AF STATION BIHTA
2024_MES_648134_3
87257/E8
Open Tender
Electrical and Maintenance Works
Item Rate
273 days
BIHTA PATNA BIHAR
Class E Category b ii and other criteria as per NIT and Tender Doc
7 documents required · 7 mandatory
₹500
GE (AF) BIHTA
₹29,500
Yes
5 Sept 2024
19 Jun 2024
15 Jul 2024
19 Jun 2024
11 Jul 2024
27 Jun 2024
19 Jun 2024 - 24 Jun 2024
Amount
M &L for complete servicing of VCB Make : Siemens/Areva/ABB installed at 11 KV Sub Stations (Radar Sub Station, Ops Sub Station No 5 , Tropo Sub Station and MRS ) Airforce station Bihta by using required T & P including taking down old unserviceale spare parts of any nature and replace with new and making functional upto the satisfaction, working with all functions like OC, UV, EF, instant tripping on fault including testing with required instruments as per secondary injection methode complete all as directed by Engr-in-Charge. The servicing covers the following :- (a) Through cleaning of breaker chamber (b) Lubrication of shutter mechanism/moving parts (c) Checking of shutter movement (d) Checking door interlocks with breaker (e) Checking of breaker interlocks with panel door (f) Checking of breaker rack in/out inside the panel. (g) Checking of closing and tripping coil (h) Checking of gear box operation. (j) Checking of Test/service Aux. switch operation (k) Checking of tripping mechanism operation. (l) Spring charging limit switches operation. (m) Checking healthiness of three poles. (n) Checking of damping device and setting. (o) Tightness, checking of power connection. (p) Checking of breaker ON/OFF operation manually and electrically. (q) Checking of closing timings.
(r) Checking of tripping timings. (s) Functional checking of all electrical and mechanical operation of breakers. (t) Co-ordination of relay and their testing with required testing equipment according to source incomer VCB and submit report for record. (g) Checking/replacement of non functional strip heaters inside the VCBs and allied works. Note: 1) The breaker shall be repaired through authorised dealer or representative of Original Equipment manufacturer. 2) The repair works shall be carried out by the contractor team in cunsultation/ instruction with the OEM. 3) Contractor is responsible to keep ready requisite spare parts and attend the breakdowns within 01 hours from recept of complaint fron concern JE/ Engineer in charge. 4) Spare parts required for repair of VCB shall be measured and paid under relevant items herein after ser No 02 to 48.
Spring Drum Cat part No 1VYN300950-20
Spring Cat part No GCE9478006P0102
Roller Chain Cat part No 1VYN400950-088
Curve Washer (RHS) New Cat part No GCE7004135R0101
Curve Washer (LHS) NEW Cat part No GCE7004136R0101
Stop Washer Cat part No GCE7006075P0101
D-Shaft Cat part No 1VYN400950-106
Cam Disc Cat part No GCE7001923P0101
Half Shaft Cat part No 1VYN400950-106
Torsion Spring Cat part No 1VYN400950-006
Torsion Spring Cat part No 1VYN400950-064
Counter Cat part No GCE9577554P0100
Blocking Crank Cat part No GCE7003097P0101
Blocking Crank Cat part No GCE7003097P0102
Locking Roller Cat part No 1VYN400950-164
Sprocket Cat part No 1VYN400950-115
Latch Cat part No 1VYN400950-116
Torsion Spring Cat part No 1VYN400950-002
Charging Lever Cat part No 1VYN400950-114
Roller Bearing Cat part No 1VYN400950-077
Torsion Spring Cat part No 1VYN400950-010
Retaining Washer Cat part No GCE0418316P0100
Lever Assembly Cat part No 1VYN400901-R
Torsion Spring Cat part No 1VYN400950-009
Torsion Spring Cat part No 1VYN400950-004
Shaft Cat part No 1VYN300950-013
Control Washer Cat part No GCE7001917P0101
Compression Spring Cat part No 1VYN400950-001
Stop Cat part No 1VYN400950-136
Motor - 220V DC/AC Cat part No 1VYN300951-002 (GCE0940084P0106)
Motor Cut Off Switch Cat part No HAGT444559P2
Sprocket Wheel Cat part No 1VYN400950-208
Torsion Spring Cat part No 1VYN400950-003
Ratchet Plate Cat part No GCE9478400P0101
Torsion Spring Cat part No 1VYN400950-005
Retaining Circlip Cat part No GCE0418205P0100
On-Off Indicator (Display) Cat part No GCE7001910P0101
Shaft Cat part No 1VYN300950-030
Tripping/Closing Coil-110V DC Cat part No 1N54450007-M
Pin Plug Assembly Cat part No IN26570001-AM
Emergency Trip Assembly Cat part No IVYN400901-AF
Connection Piece Cat part No 1VYN400950-204
Aux. Switch Cat part No 1VYN300950-064
Contact System For VD4-630 A (12 Finger) Cat Part No. GCE8385888R0102
Alu.Contact Arm Assly.For VD4 CB(800A) Cat part No GCE700142R0119
Cu.Contact Arm Assly.VD4 CB Cat part No GCE7001421R0101
Contact System For VD4-1250 A(DIA.34 &24 Finger) VD4 Cat part No GCE8385888R0101
S & F in replacement of unsv/melted sleeved copper bus bar 800Amps for interconnection between siemens -3 Nos breakers + 1 No bus coupler including replacement of suitable size of steel nuts, bolts & washers etc complete all as specified and as directed.
S & F Racking trey stand of suitable size for racking of VD4 breaker In/Out. The size of racking shall be as per manufacturers instruction.
S & F space heater 0.5kw, 230v AC suitable for VCB alongwith suitable size of thermostat for instant tripping.
M & L for complete servicing of RMU Make : ABB installed at various 11 KV Sub Stations at AF Stn Bihta by using required T & P including taking down old unserviceale spare parts of any nature and replace with new and making functional upto the satisfaction, working with all functions like OC, UV, EF, instant tripping on fault including testing with required instruments complete all as directed by Engr-in-Charge. The serviing covers the following :- (a) Through cleaning of breaker chamber (b) Checking of closing and tripping coil (c) Checking of Test/service Aux. switch operation (d) Checking of tripping mechanism operation. (e) Spring charging limit switches operation. (f) Checking healthiness of three poles. (g) Tightness, checking of power connection. (h) Checking of breaker ON/OFF operation manually and electrically. (j) Checking of closing timings. (k) Checking of tripping timings. (l) Functional checking of all electrical and mechanical operation of brekers. (m) Co-ordination of relay and their testing with required testing equipment according to source incomer VCB.
Note: - (a) The breaker shall be repaired through authorised dealer or the representative of OEM manufacturer. Location : Sub Stn No 2, ATC Sub Stn, TC P/H Sub Stn & Sub Stn No 5 (b) The repair works shall be carried out by the contractor team in cunsultation/ instruction with the OEM. (c) Spare parts required for repair of RMU shall be measured and paid under relevant items herein after ser No 53 to 66. (d) After completion of repair work, RMU shall be connected to full load and testing to be carried out infront of AGE E/M/GE (AF) showing all functional/operational system are working satisfactorily.
Bushing 400 Series Bolted Type Cat part No NHP201699R1 Make : ABB
O' Ring 72x6 Bushing 400 series bolted Cat Part No NHP402076P15 Make : ABB
Trip coil safeo force Amplifier Cat No 1VDP000142R1 Make : ABB
VPIS unit, 9-15 kv type, Cat No YN1V400916-587 Make : ABB
Relay Make : Ashida Cat No 4200013670
Digital COS₵ Meter ,Make –Conzerv ,C.l-1.0,Aux.Supply- 80-240V AC/DC.
Digital Ampere Meter Make –Conzerv,C.l- 1.0. Aux.Supply- 80-240V AC/DC.
Digital Volt Meter Make –Conzerv,C.l- 1.0. Aux.Supply- 80-240V AC/DC.
Numerical O/C & E/F Relay , Aux.Supply- 80-240V AC/DC. CT- 5-1A., Cat part No ADR141C.
VAA 33 Aux.3 Element Relay ,Aux.Supply 30V DC,06 ON Contacts,
VAJH13 Master trip relay ,Make- Alstom, Aux.Supply 30V DC.04 ON Contacts & 01NC Contacts
Damaged/unsv CT of Ratio – 60/5+5A,VA-7.5VA,5P10,C.l-1.0 Make- NPP,Power Foil,
Damaged 3 Phase PT of ratio – 11KV/110V ,VA-100,C.l-1.0. suitable for existing model VCB Make- NPP,Power Foil.
Bus bar insulator as per existing size model suitable for HT 11000 volts.
Supply, Laying, Jointing and Testing of HT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 11000 volts Earthed, grade cross sectional area 95 Sqmm 3 core laid in trenches/ducts/along poles/ through pipe under road etc complete and incl taking out old unserviceable HT UG cable with old bricks complete all as specified and directed by Engr-in-Charge. Note :- (i) Excavation, earthwork, cable protection cover, cable joint, sand cushioning shall be measured and paid for separately under respective item of this schedule.
M & L for GOD switch, Material and labour for switch Air break gang operated triple pole mechanically operated vertical type 12 insulators and with galvanized frame, operated from ground level including operating rod, handle locking mechanism, current carrying capacity 200 Amps 11000 Volt with nut bolt and washers etc including taking down of old UNSV GODO complete all as specified and as directed.
Cable jointing kit suitable for 11 KV (Earthed) grade cable outdoor termination, heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 70 to 120 Sq mm complete all as specified and as directed.
Cable jointing kit suitable for 11 KV (Earthed) grade cable indoor termination, heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 70 to 120 Sq mm complete all as specified and as directed.
Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr deep in loose / soft soil and getting out for under ground cable / erection of poles, stays etc complete all as specified and as directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers n.exc 25 cm thick complete all as specified and directed.
Removing of excavated material n, exc 50 mtr away and depositing where directed at a level n, exc 1.5 mtr above the starting point complete all as specified.
Labour for re-laying of bricks subclass ‘B’ old size laid flat perpendicular to the direction of cable for protection of cable complete all as specified. Note : Old Brick taken from respective taking out item old U/s HT UG Cable with bricks
M&L for laying of bricks subclass ‘B’ old size laid flat perpendicular to the direction of cable for protection of cable complete all as specified.
Supply, laying and cushioning of sand for cable protection in trenches 8 cm deep before laying cable and 15 cm deep over the cable including well punning complete all as specified and dierected. Note-Only punned depth 18 cm of sand shall be measured for payment.
M&L for PCC 1:4:8 type D-2 using 40mm graded aggregate, mechanically crushed stone for mass filling in pole pit /foundation /any other means etc compete all as specified and directed.
M&L for PCC 1:3:6 type C-1 using 20mm graded aggregate mechanically crushed stone for mass filling in stay pits and foundation /any other means all as specified.
Supply & fixing GI Tubing 80mm bore light grade, on poles, under floors, road crossing etc all as reqd at site complete and taking out old unsv rusted 80mm bore GI tubing complete all as specified as directed by Engr-in-Charge.
Disconnecting & taking out defective under ground cable from trenches, pole, pipe, floor, wall etc locate the fault, rectify the defect and relaying the XLPE cable under ground PVC insulated and overall sheathed aluminum conductor heavy duty 11000 volts connecting and testing complete all as directed by Engineer-in-Charge Note :-(Excavation,earth work, brick protection sand cushioning and GI pipe etc shall be measured & paid for separately)
M&L for new earthing complete with galvanized steel earth plate 600x600x6 mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanised iron strip 32x6 mm dia as earthing lead by means of bolts, nuts, check-nuts, and washers of galvanised iron or steel besides welding at all joints as shown in drawings and including excavation and earth work, GI pipe light grade 40 mm bore for protection of GI strip from earth electrode to and including the earth test point of galvanised Iron/steel . supplying and laying charcoal stone aggregate) chamber and Cast iron earthing pit cover square shaped (250 X 250) mm of size not less than 7.5Kg weight as pe IS code with wire mesh, 20 mm dia GI pipe medium grade for watering all as shown in drawing complete and including Taking out old unserviceable existing earthing complete all as specified and directed. Note - Cost of GI strip and GI protection pipe up to a distance 7.5 M shall be included in quated rate of above Items.
Supply and filling of insulating/cooling transformer oil EHV type conforming to IS 3359 of 1983 suitable for 11 KV Complete all as directed by Engineer-in-Charge
VISHWAKARMA ELECTRICAL
Raj Construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .