FINDC2526100010-(CONSTRUCTION OF BUILDING FOR BHQ ARIPAL) (Electrical Part)
2026_RDPR_306316_23
e- NIT No. 201/2025-26 Dated 16-03-2026
Open Tender
Electrical Works
Percentage
30 days
Pulwama
Please refer Tender documents.
2 documents required · 2 mandatory
₹200
Executive Engineer REW Pulwama
₹2,758
27 Mar 2026
16 Mar 2026
27 Mar 2026
16 Mar 2026
25 Mar 2026
16 Mar 2026
Wiring for light point/ fan point/exhaust fan point with 1.5.sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in existing surface /recessed medium class PVC conduit ,with modular switch(Anchor roma urban /eq.make), ,suitable modular GI box and earthing the point with 1.5 sq mm FRLS /HFFR PVC insulated copper conductor single core cable etc as required (Havells /Legrand/roma urban/Eq.make as par ISI Standard Note The GI boxes can be of different sizes of Modulues to hold the Modular Boxes and Modular Switches for lights/fans/exhaust fans and are included in the point rate
Supply ,fixing,drawing testing and commissioning of 3x2.5 sqmm FRLS/HFFR PVC insulated copper conductor (Havells/Anchor/Eq.make),single core cable in existing surface /recessed medium class PVC conduit.Note This includes Three wires (Phase,Neutral and Earth) and 1 Ckt meter is equivalent to 3 meters
Supply ,fixing,drawing testing and commissioning of 3x4 sqmm FRLS/HFFR PVC insulated copper conductor (Havells/Anchor/Eq.make),single core cable in existing surface /recessed medium class PVC conduit.Note This includes Three wires (Phase,Neutral and Earth) and 1 Ckt meter is equivalent to 3 meters
Supply drawing ,fixing testing and Commissioning of 3x6 sqmm FRLS PVC insulated copper conductor (Havells/Anchor/Eq.make),single core cable in existing surface /recessed medium class PVC Conduit for ACs .Note This includes Three wires (Phase,Neutral and Earth) and 1 Ckt meter is equivalent to 3 meters
Supply of fixing of 25/32 mm size PVC condute along with accessories(bends,sockets,iron staples/saddles/screws,pvc fastener etc) in surface /recess include in cutting the wall and making good the same by cement sand and paint in case of recessed /Surface condute as required for Walls and Slab
Supply of fixing of Suitable GI Box with Modular Plate and cover in front on surface or in recess including providing and fixing of 6 pin 5/ 6 amp and 15/16 amp /230 V AC modular socket and 15/16 amp modular switch(Anchor Ro urban/SSK NV/Havells /Eq.make)
Supply of fixing of Suitable GI Box with Modular Plate and cover in front on surface or in recess including providing and fixing of 3 pin 5/ 6 amp /230 V AC modular socket and 5/6 amp modular switch(Anchor Ro urban/SSK NV/Havells /Eq.make)
Supply installation testing and commissioning of 1200 mm dia sweep,ceiling fan with BLDC motor,30 cm long down rod ,2 No Canopies,shackle kit,safety rope Cu winding ,steel/al body,pf not less than 0.9 etc Havalles make /Bajaj/Crompton(Flavia)of eq.standard
Supply of fixing of 6 amp /230 V AC fan dimmer step type 2 module with cover plateAnchor Ro urban/SSK NV/Havells /Eq.make.
SITC of 230-250 mm dia Sweep Exhaust Fan with ceiling rose of standard make
S/F testing nd comm..of recessed /surface mounted 12 watt LED down lighters SMD type system Luman efficacy >= 105<120 lm/watt Philips /havalles /bajaj/Crompton make of eq. standards
SITC of 20 watt LED bulk lights of standard make (Complete Job)
Suppling and fixing of 16 way horizontal type single pole and neutral sheet steel,MCB distribution board ,240 V ,On surface /recess,complet with neutral bus bar,earth bar,din bar interconnection ,powder painted including earthing etc .as required .(But with out mcb/ Rccb/Isolator ):-Hager /Legrand /ssk/equt .standard
S/F testing and comm..of MCB of the below mentioned capacities in sub main control legrand C curve series 6-32 Amp SP MCB
S/F testing and comm..of MCB of the below mentioned capacities in sub main control legrand C curve series 40- 63 Amp DP MCB
Supply ,laying partly overhead partly underground ,testing and commissioning of 16sqmm Two Core Al cable of standards make
SITC of 63 amp 4 way Connectror including Providing of 3x10sqmm FRLS cu wire(5 Ckt mtr) from Mains DB to Connector to be installed outside the building
Earthing with GI earth Pipe 2.15 metre long (2 Nos) ,40 mm dia including and providing Masonary Enclosure with Iron cover plate having locking arrangement and watering pipe etc with charcoal/coke/salt as required along with 10 SWG GI Wire /25X3 mm GI Strp upto the nearest point of earth to be supplied/drawn from Main Power distribution Board and connecting the same (Complete Job) as per the directions of engineer incharge
stage.html
html • 0.02 MB
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.44 MB
BOQ_994674.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .