SE ETC-I Kanpur
SE ETC-I Kanpur
FOR OVERHAULING SERVICING AND REWINDING OF TRANSFORMER COOLING FANS AT 220KV SUB STATION BITHOOR 132 KV DADANAGAR 132 KV BILHAUR AND 123 KV RASOOLABAD UNDER ETD I KANPUR
2026_UPTCL_1139908_1
ET-02/ETC-I(K)/2026-27
Open Tender
Electrical Works
Fixed-rate
90 days
SE ETC-I Kanpur
Please refer Tender documents.
3 documents required · 3 mandatory
₹590
PNB A/C-0727002100004177
₹3,800
21 Apr 2026
21 Apr 2026
22 May 2026
21 Apr 2026
21 May 2026
21 Apr 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| - | Servicing of different make T/F cooling fans (size 18"/ 24") . The job includes dismantling of fans, cleaning of blades, replacement of both side bush & bearing and their oiling/greasing work along with refixing of fans on their origional place radiator after complete servicing & checking for smooth operation of cooling fans with all the cable connection work complete in all respect. (All consumable material will be arranged by contractor at his own cost) The details of the numbers of T/F cooling fans along with the name of the sub-stations, are given below- | - | - | - | - |
| 1.1 | At 220 KV Sub-Station Bithoor, Kanpur. 160MVA (Ist & IInd) | 10 | Nos. | - | - |
| 1.2 | At 220 KV Sub-Station Bithoor, Kanpur. 40MVA (Ist & IInd) | 8 | Nos. | - | - |
| 1.3 | At 132KV Sub-Station Dadanagar, Kanpur. 40MVA & 63 MVA (Ist & IInd) | 10 | Nos. | - | - |
| 1.4 | At 132KV Sub-Station Rasoolabad, Kanpur Dehat. 40MVA (Ist & IInd) | 10 | Nos. | - | - |
| 1.5 | At 132KV Sub-Station Bilhaur, Kanpur Nagar. 63MVA & 40 MVA (Ist & IInd) | 12 | Nos. | - | - |
| - | Rewinding of burnt/damaged T/F cooling fans (size 18"/24") 3 Phase, 415Volts fan motor with replacement of both side bush/bearing and their oiling & greasing work .The job includes dismantling of fans from the transformer radiator frame and rewinding with the help of super enameled copper wire "B" class insulation & varnish on the winding along with repair of broken or damaged body of motor body and refixing the same on the frame of transformer radiator including checking/termination of circuit of fan for smooth operation. (If any defect occurs in the Rewinding cooling fans within 06 months, the firm will be obligated to repair it within 15 days of being informed, without any additional cost) . The details of the numbers of T/F cooling fans along with the name of the sub-stations, are given below- | - | - | - | - |
| 2.1 | At 220 KV Sub-Station Bithoor, Kanpur. 160MVA (Ist & IInd) | 12 | Nos. | - | - |
| 2.2 | At 220 KV Sub-Station Bithoor, Kanpur. 40MVA (Ist & IInd) | 9 | Nos. | - | - |
| 2.3 | At 132KV Sub-Station Dadanagar, Kanpur. 40MVA & 63 MVA (Ist & IInd) | 11 | Nos. | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.28 MB
Tendernotice_2.pdf
PDF • 1.14 MB
BOQ_2128465.xls
BOQ • 0.24 MB
Corg02.pdf
PDF • 0.21 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .