Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.9 CrAccepted-AOC BHETAPARA CHARIALI ABOVE UCO BANK GUWAHATI 781028 | GUWAHATI | KAMRUP | ASSAM | 781028 | L1 | Accepted-AOC Work Order Issued | |
| 2 | L2₹11.3 Cr+₹37.5 L (3.44%)Rejected-Finance | L2 | Rejected-Finance Accepted | |
| 3 | Rejected-Technical RAJAMAIDAN NEW COLONY CITY TOWN JORHAT P O JORHAT P S JORHAT DISTRIST JORHAT PIN 785001 | JORHAT | ASSAM | 785001 | - | Rejected-Technical Not-Qualified |
| Sl No | Description | Qty | Unit | M/S Mayur Associates L1 | Bikash Enterprises L2 |
|---|---|---|---|---|---|
| 1.00 | Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap, to carry a safe working load not less than specified,excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by percussion drilling using Direct mud circulation (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated earth with all its lifts and leads (length of pile for payment shall be measured up to bottom of pile cap).Note: Truck Mounted rotary/TMR/Tubewell boring machine shall not be used 450 mm dia piles | 5,513 | Metre | 1,693.85 ₹93,38,207.73 Lowest | 2,500 ₹1,37,82,500 |
| 2.00 | Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge. Note: 1. Initial and Routine Load Test shall not be carried out by Note: 2. Testing agency shall submit the design of loading platform for the approval of Engineer-in-charge.Single pile upto 50 tonne Safe capacity
Initial test (Test Load 2.5 times the Safe capacity) | 2 | Per Test | 45,528.78 ₹91,057.55 Lowest | 60,000 ₹1,20,000 |
| 3.00 | Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge. Note: 1. Initial and Routine Load Test shall not be carried out by Note: 2. Testing agency shall submit the design of loading platform for the approval of Engineer-in-charge.Single pile upto 50 tonne Safe capacity
Routine test (Test Load 1.5 times the Safe capacity) | 7 | Per Test | 16,319.41 ₹1,14,235.9 Lowest | 35,000 ₹2,45,000 |
| 4.00 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed.
All kinds of soil | 1,374.76 | Cum | 181.59 ₹2,49,644.73 Lowest | 300 ₹4,12,428 |
| 5.00 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
All kinds of soil. | 118 | Cum | 253.54 ₹29,917.56 Lowest | 290 ₹34,220 |
| 6.00 | Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :
All kinds of soil.
Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia | 200 | Metre | 368.88 ₹73,776.8 | 150 ₹30,000 Lowest |
| 7.00 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | 786 | Cum | 265.16 ₹2,08,417.02 | 260 ₹2,04,360 Lowest |
| 8.00 | Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth,sides of foundation etc. complete. | 1,528 | Cum | 353.55 ₹5,40,222.57 Lowest | 370 ₹5,65,360 |
| 9.00 | Supplying and filling in plinth with Jamuna sand under floors, including watering, ramming, consolidating and dressing complete. | 1,447 | Cum | 1,910.22 ₹27,64,094.37 | 900 ₹13,02,300 Lowest |
| 10.00 | Clearing grass and removal of the rubbish upto a distance of 50 m outside the periphery of the area cleared. | 1,206 | Sqm | 17.68 ₹21,318.99 Lowest | 50 ₹60,300 |
Tender Value
₹11.0 Cr
EMD Value
₹22.1 L
Closing Date
12 May 2022, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CE, PWD (Bldg), Assam, Chandmari, Ghy-3
O/O The CE, PWD (Bldg), Assam, Chandmari, Ghy-3
Construction of Lalit Chandra Rajkhowa Mini Stadium at Jagduar, Teok, Jorhat, Assam under NIDA
2022_PWBNH_25222_16
CS/T/TB-I/17/2022/4 Dated Guwahati 21th April 2022
Open Tender
Civil Works - Building
Item Rate
545 days
Jorhat
Please refer Tender documents.
5 documents required · 5 mandatory
₹20,000
₹22.1 L
Yes
O/O The CE, PWD (Bldg), Assam, Chandmari, Ghy-3
5 Jan 2023
25 Apr 2022
13 May 2022
25 Apr 2022
12 May 2022
3 May 2022
29 Apr 2022
180 days
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap, to carry a safe working load not less than specified,excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by percussion drilling using Direct mud circulation (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated earth with all its lifts and leads (length of pile for payment shall be measured up to bottom of pile cap).Note: Truck Mounted rotary/TMR/Tubewell boring machine shall not be used 450 mm dia piles | 5,513 | Metre | - | - |
| 2 | Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge. Note: 1. Initial and Routine Load Test shall not be carried out by Note: 2. Testing agency shall submit the design of loading platform for the approval of Engineer-in-charge.Single pile upto 50 tonne Safe capacity
Initial test (Test Load 2.5 times the Safe capacity) | 2 | Per Test | - | - |
| 3 | Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge. Note: 1. Initial and Routine Load Test shall not be carried out by Note: 2. Testing agency shall submit the design of loading platform for the approval of Engineer-in-charge.Single pile upto 50 tonne Safe capacity
Routine test (Test Load 1.5 times the Safe capacity) | 7 | Per Test | - | - |
| 4 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed.
All kinds of soil | 1,374.76 | Cum | - | - |
| 5 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
All kinds of soil. | 118 | Cum | - | - |
| 6 | Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :
All kinds of soil.
Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia | 200 | Metre | - | - |
| 7 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | 786 | Cum | - | - |
| 8 | Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth,sides of foundation etc. complete. | 1,528 | Cum | - | - |
| 9 | Supplying and filling in plinth with Jamuna sand under floors, including watering, ramming, consolidating and dressing complete. | 1,447 | Cum | - | - |
| 10 | Clearing grass and removal of the rubbish upto a distance of 50 m outside the periphery of the area cleared. | 1,206 | Sqm | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
BOQ_39039.xls
BOQ Document • 0.51 MB
96927517.pdf
Tender Document • 0.11 MB
SBDTeok.pdf
Tender Document • 1.21 MB
96927521.html
Tender Document • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .