Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹21.3 LAccepted-AOC | 1 | Accepted-AOC L1 | |
| 2 | 2₹23.4 L+₹2.1 L (9.98%)Rejected-Finance | 2 | Rejected-Finance Not lowest | |
| 3 | 3₹23.7 L+₹2.5 L (11.5%)Rejected-Finance | 3 | Rejected-Finance Not Lowest | |
| 4 | 4₹24.0 L+₹2.7 L (12.9%)Rejected-Finance | 4 | Rejected-Finance Not Lowest |
Tender Value
₹24.8 L
EMD Value
₹50,000
Closing Date
19 Jul 2021, 6:00 pmClosed
Garrison Engineer Abohar
Garrison Engineer Abohar Pin-152116
Provision of fencing with gate for transformer yards and other sanctioned works at Mil Stn Abohar
2021_MES_453262_1
GE ABH-33/21-22
Open Tender
Civil Works
Item Rate
150 days
Abohar Mil Stn
MES Registered Contractor enlisted in class E Category a (i) having deposited standing security of Rs 50000 with departments. Contractors not registered in MES should meet the MES enlistment criteria corresponding to appropriate class and category
6 documents required · 6 mandatory
₹500
Garrison Engineer Abohar
₹50,000
Yes
26 Aug 2021
21 Jun 2021
21 Jul 2021
21 Jun 2021
19 Jul 2021
6 Jul 2021
Amount
SCHEDULE 'A' SECTION I (B&R Portion)
Dismantling of floor hearth or wall tiling including cement mortar bedding ( but not backing) and rubbish off the permices.
M&L for joint free Non skid ceramic coloured tile 7 to 8 mm thick (square / rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm , in floors etc.over and including 15mm thick screed and bedding in cement mortar 1:6, set and jointed in neat cement slurry and pointed in white or colour cement to match with the existing surface etc all as specified.
M & L for glazed ceramic coloured tiles 7mm thick 300 x 450mm size in vertical surface set and jointed in neat cement slurry and pointed in white cement paste pigmented to the shade over 10mm thick cement sand screed (1:4) complete all as specified .
Taking down chowkats or frames with shutters (with out taking off shutters from the frame) not exceeding 1.50 Sqm each all as specified .
S&F for Fiber Glass Reinforced plastic (FRP) Door Frames of cross section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminte shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame., complete as specified by the manufacturer and as per directions of Engineer-in-charge.
S&F to existing door frames 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames, complete as specified by the manufacturer and as per directions of Engineer- in-charge
S&F 125mm Aluminium anodised barrel tower bolt of extruded section and fixed.
S&F 150mm extruded aluminium alloy handles, fabricated type anodised.
S&F 100mm butt hinges, medium weight , cold rolled mild steel and fixed.
S & F powder coating anodised aluminium frame with extra powder coating for doors, windows, with one or more rebate including joining cleat for fixing etc complete.
S & F for powder coating Anodised aluminium window and ventilator shutters side hung type without sash, aluminium sections weighing 0.55 kg/ m including necessary joining cleats, glazing clips rubber packing, anodised aluminium snap beading screws Anodised aluminium fitting such as peg stays 150 mm long (1 No ) hinges type B-21 100 mm long (2 no) suitable handle(1 No) complete all as specified.
S & F Stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40mm all as specified .
S & F figured glass 5mm thick pin head type and glazing with oil putty and securing with glazing pins not exceeding 0.50 Sqm in each pan complete all as specified .
S&F aluminium anodised grill diamond shape 100mm x100mm aperture of 6mm dia round bars including necessary joining cleats,clips anodised aluminium snap beading screws complete all as specified as directed by Engr-in-Charge.
Taking down cement plaster/dado on brick wall including racking out joints, hacking for keys scrubbing down with water all as specified .
M&L for rendering 10 mm thick in CM 1:3 on ceiling, finished the surface even and smooth without using extra cement all as specified and directed.
M&L rendering 15mm thick in CM 1:6 on fair face of brick or concrete surface,finished even and smooth without using extra cement complete .
M&L for preparation of newly plastered ceiling surfaces and applying two coat of oil bound distemper over a coat of clearcolle primer complete all as specified & directed by Eng-in- Charge.
M&L for preparation of newly plastered wall surfaces and applying two coat of oil bound distemper over a coat of clearcolle primer including 3mm thick wall care putty complete all as specified & directed by Eng-in- Charge.
S&F in repairVitreous China wash down water closet pan (pedestal pattern), white (excludin fixing bolts, flushing cistern and flush pipe) with PVC sheet cover & 'P' OR 'S' trap.
S&F PVC high or low level cistern of 10 litres capacity including 32mm dia. Flush pipe and internal fittings complete all as specified.
S & F Jet spray assembly with all fittingd in EWC all as directed
S&F Snowbell jaquar sleek health faucet with 1 meter flexible tube and wall hook
S&F in repair vitreous china wash hand basin, white flat back of size 550 x 400 mm including waste coupling, waste pipe and bracket complete all as specified.
S&F brass chromium plated Basin mixer for mixing hot or cold water screwed down for iron pipe with regular spout,popup waste system and 450mm long braided hoses with connection and nuts complete all as specified and directed by Engr-in-charge.
S&F brass chromium plated wall mixer with Provision for overhead shower with 140 mm long bend pipe and flange for mixing hot& cold water screwed down for iron pipe and fixed as directed by Engr-in- charge.Make:- ESS ESS cat part No.- C-216D
S&F PVC bathroom cabinet mirror 450 x 350 mm complete all as specified and directed by Engr-in-charge.Make:-Prayag cat part no551/polytuf/shakti/pearl as approved by GE.
Towel Bracket chromium plated brass 61cm size make -ESSESS Cat Part No.-AC-308.
Toilet paper holder fix with chromium plated brass screw and wooden/ plastic cleats complete. make -ESSESS AC-706.
Acrylic shelf size 46 cmx13 cm make -ESSESS Cat Part No.-AC-307.
S & F 15 mm bore concealed stop cock cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions and fixed but fancy type chromium plated with long shank and cup (Concealled type)
S&F 15mm bore stop valve fancy type chromium plated with long shank and cup cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions all as specified and directed.
S & F in PVC connection 15mm size with PTMT nuts of length 450mm all as specified .
S & F 15 mm bore bib tap fancy type chromium plated with crutch or butterfly handle screwed down ,screwed for iron pipe all as specified.
S & F soap dish fixed as chromium plated.
S & F Chromium plated shower roses with swivel joints any size including fixing to steel pipe or union.
S & F Chromium plated shower arm 15mm size 195mm long with bend 45 degree any size including fixing to steel pipe or union.
Taking down steel tubing 15mm bore and connections complete all as specified.
Fixing only tubes any grade 15mm bore to walls and ceiling or in floors etc including provision of new fittings as required (Serviceable galvanised tubes retrieved from respective items shall be laid under these items) all as specified .
S & F 15mm bore medium grade tube galvanised with all fittings and fixed complete concealed including groove cutting for concealing to walls & ceiling or laid in floor all as specified .
Taking down steel tubing 20mm bore and connections complete all as specified.
Fixing only tubes any grade 20mm bore to walls and ceiling or in floors etc including provision of new fittings as required (Serviceable galvanised tubes retrieved from respective items shall be laid under these items) all as specified .
S & F 20mm bore medium grade tube galvanised with all fittings and fixed complete concealed including groove cutting for concealing to walls & ceiling or laid in floor all as specified .
S & F Grating doom 125 mm dia with waste hole of PTMT ( Min wt 40 gm )
S&F 75mm PVC(SWR) floor trap plain with grating including jointing with solvent cement.
S & F PVC(SWR) 75 mm bore vent cowls complete all as specified and directed by Engr-in-charge.
S & F PVC(SWR) 110 mm bore vent cowls complete all as specified and directed by Engr-in-charge.
S&f PVC(SWR) 75 mm bore junction (singleT) equal or unequal
S&f PVC(SWR) 110 mm bore junction (singleT) equal or unequal
Taking down CI/AC/PVC soil waste and vent pipe any radius including all fittings complete.
S&F PVC ( SWR) pipes bore of 110 mm single socketed in any length with rubber ring joints laid in trenches or in floors all as specified
S&F PVC ( SWR) pipes bore of 75 mm single socketed in any length with rubber ring joints laid in trenches or in floors all as specified
Excavation in trenches in exc 1.5 m wide and not exc 1.5 M depth for foundation and getting out in soft and loose soil all as directed.
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out
M & L for PCC 1:4:8 type D2 using 40 mm graded stone aggregate in foundation filling and mass concrete.
Removing excavated naterial n . Exc 50 m and deposited where derected at a level n. exc 1.5m above the starting point.
Returning, filling in including spreading leveling watering and well ramming in layers not exc 25 cm all completed as specified in soil
M & L for hardcore of gauge of brocken bricks n exc. 63 mm deposited spread and levelled in layers n exc 15 cm thick,watered and rammed to a true surface.
M&L for PCC 1:4:8 Type D-2 100 mm thick as in sub base all as specified.
M & L PCC 1:2:4 type B1(20 mm Graded aggregate ) 40 mm thick as in floor finishing even and smooth without using extra cement.
M&L for Glass dividing strip 3 mm thick 38mm wide all as specified & directed.
S&F Structural steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes grade St-240 complete all as specified and as shown on drawing.
S & F MS Plate 6 mm thick as in gusset plate in Fe 410 incl necessary welding.
M&L for Brick work using fly ash bricks, straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and directed by Engineer-in-Charge.
M & L for rendering 15 mm thick on brick work or concrete surface in CM 1:4 finishing even and smooth without using extra cement, all as specified and directed by Engr- in- charge.
M & L two coats of cement base paint over new plastered surface including preparation of surface complete all as specified .
M&L for Two coat of oil bound distemper on new plastered wall surfaces of walls over wall care putty including necessary preparation of surfaces all as specified
M & L providing two coats of synthetic enamel paint over new surface and a coat of red oxide primer on steel surfaces including preparation of surface of any description exceeding 10 cm width or girth all as specified .
S&F Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
S&F Factory made box type steel window with hung shutter both glazed and gauged ,shutter frame 60x25mm ERW hollow 'P' section with wall thickness not less than 1mm fixed to pressed steel frame 120mmx 70mmx1.6mm thick including fixing glazed portion,iron grills 8mm suare MS bar hunges with steel handle and fitting, lugs etc, including one coat of primer complete all as shown in drg No BTD 889 sheet 1/4 to 4/4 specified and directed.) (Note :- Wire mesh and glass shall be measured and paid separately under relevent items of shch/BoQ)
S & F pressed steel door frames with one or more rebates including necessary fixing lugs hinges lock strike plate etc complete all as specified size of frame 125X60mm all as specified .
M&L Cement concrete 1:3:6 type C-1 for filling of pressed steel fram and hold fast blocks etc all as specified .
S & F Factory made Plain framed, panelled shutter IInd class hardwood rail and style 35 mm thickness (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated
S & F Factory made 35mm thick IInd class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc.; size of members of shutters as specified in SSR Part – I, Section – 8, clause 8.20 (a) ; supplied and fitted to chowkats all as specified .
S & F aluminium tower bolts, stove enamelled black, with bright bolt and fixed, length of bolt 150mm long all as specified .
S & F aluminium bow handle stove enamelled black, 150 mm long all as specified .
S & F mild steel sliding door, bolts, plate type, stove enamelled black with bright bolt not less than 12mm bore, length of bolt 250mm all as specified .
M & L providing two coats of synthetic enamel paint over new wooden surface including preparation of surface with primer all as specified .
Roughening surface of old concrete floor by picking sweeping clean and washing down with water to remove dust etc.
M & L Machine cut kota stone slab flooring 20 - 25 mm thick over cement screed base laid over and including 20mm thick screed bed in cement mortar 1:4 set and jointed with grey cement slurry mixed with pigment to match of the slab including rubbing and polishing complete all as directed.
M & L Machine cut kota stone slab 20 - 25 mm thick in riser of steps,skirting,dado and pillar over cement screed base laid over and including 20mm thick screed bed in cement mortar 1:4 set and jointed with grey cement slurry mixed with pigment to match of the slab including rubbing and polishing complete all as directed.
SCHEDULE 'A' SECTION-II (E&M PORTION)
Excavation in trenches any type of soil , n exc 1.5m wide and n exc 1.5m in depth , for foundation , etc or for shaft, well, cesspits , manholes , pier hole etc n exc 1.5 m in depth and getting out for laying of cable complete all as specificed and directed.
Returning , filling in including, spreading , levelling , watering and well reamming in layers not exc. 25 cm complete all as specificed and directed.
Removing excavated material n exc 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specificed and directed.
M&L for Sand filling under flooors, in trenches or in foundation for cable protection including and consolidation as as specified and directed at site.
M & L brick sub class 'B' locally available best quality laid in trenches above sand consolidted forcable protection complete all as specified and directed.
M&L for cutting up to 30 cm width and depth of the road/hard standing and making good disturbed surfaces by using PCC type C2(1:3:6) by using 40mm graded stone aggregate for the fixing the pipe complete all as directed by the Engr. in Charge.
S&F un-reinforced precast concrete cable cover class HVP type 1 with peak, size 300mmx180mmx40mm laid flat length of cover across the length of cable and old US PCC cover to be disposal off 100 mtr away from the site complete all as specified and directed by Engr-In-Charge.
Laying and commissioning only UG Cable of size 3/3.5 Core of any size and grade/capacity laid in trenches/Road/paths/ on poles through GI protection pipe complete including connection of cable at both ends with suitable size of glands, aluminium lugs complete joining, testing and commissioning including disconnecting and removing existing UG Cable and re use serviceable cable by taking out with safe measures Note:1. UG Cable shall be laid against retrived Serviceable cable under relavent items of the schedule. 2. Earth work for the cable removing, laying measured and paid separately under relevent items of the schedule.
M&L for filling of aggrigate for loose filling of size 40 mm to 80 mm graded brocken stone aggrigate pices complete all as specified and directed by Engineer-in-charge.
M&L for painting of old painted surfaces with synthetic enemel paint to HT steel tubbular pole 11 mtr long including clamps,brackets,chanels,cross arms,bracing support and supporting pipe of cables etc including zebra painting at bottom up to 1.5 mtr above from the PCC couping and writing pole No with white paint complete etc complete all as specified and as directed.
All as per item No 94 herein before but for 4 pole structure including cross arm,bracings etc.
All as per item No 94 herein before but for 2 pole structure including cross arm,bracings etc.
M&L for Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth of not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick and packed layer of charcoal dust and common salt, connected to galvanised iron earht strip 25x4mm thick fixed by means of bolts, nuts and washers of the earth wire galvanised iron or steel and thimbles and other end of the earth wire connected to earthing test point and protected by galvanised iron pipe light grade 40mm dia upto 3m height above ground level and watering pipe 20mm dia GI medium grade including earthwork, PCC chamber in PCC (1:3:6) type C-2 using 40mm stone aggregate, cast iron cover, wire mesh etc all as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009 complete and all as specified and direcrted by Engr-in-charge Notes :- (i) 20 mm dia GI pipe for watering (ii) GI strip connecting upto pump,Gen set,LT panel and DBs earth connection is included in this item. (iii) GI pipe 40 mm dia protection pipe shall be provided upto Ground level.
M&L for Earthing complete with GI earth plate electrode of size 600x600x6 mm thick buried directly in ground with earth pit not less than 2.25 meter deep below ground level with top edge of plate not less than 1.5 meter below normal ground level connected to GI wire 4 mm dia earth lead by means of nuts, bolts, check nuts, washers of galvanised iron as steel, protected by galvanized iron pipe 40mm bore (Medium grade) all as directed including cement concrete (1:3:6) type C-1 earth pit with precast RCC (1:1.5:3) type A-1 cover slab of size 42 x 42 x10cm thick reinforced with 8mm dia TMT bars @ 15 cm c/c both ways with 10mm dia mild steel round bar of 30 cm long, bent to shape as lifting handle, funnel, wire mesh, 20 mm bore galvanized iron pipe (medium grade) for watering, earth testing point, charcoal or coke and salt in alternate layers with necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR Part I including testing on completion all complete as specified and directed after taking down old earthing.( GI wire upto 7.5m including testing consider in this item).
S & F GI tube light grade galvanised of size 100 mm with all fitting and fixed to wall and celling or laid in floors/under road etc complete all as specdied and directed by Engineer-in- Charge.
S & F GI tube light grade galvanised of size 80 mm with all fitting and fixed to wall and celling or laid in floors/under road etc complete all as specdied and directed by Engineer-in- Charge.
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm,
Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165
M&L for providing two coats of synthetic enamel paint over new surface and a coat of red oxide primer on steel surfaces including preparation of surface of any description not exceeding 10 cm width or girth all as specified.
M&L for Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured)
M&L for Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface
M&L for PCC (1:3:6) type C2 (using 40 mm graded stone aggregate ) as om fpimdatopm. Filling and mass concrete complete all as specified.
M&L for Old size bricks in cement mortar Brickwork with fly ash on plan exc 6m mean radius, built in cement mortar (1:6) complete all as specified and directed
M&L 15 mm thick screed bed or bedding layer of cement mortar 1:4 for layiny floor finishes, etc. complete all as specified and directed by Engineer-in-charge.
M&L for for three coats of white wash to the wall surfaces after preparation to the new plastered surfaces
M&L for providing cement concrete type B0, 1:2:4 using 12.5 mm stone aggrigate as in coping, bed blocks platforms etc all as specified, rounded or chamfered on edges complete all as specified.
M&L for disconnecting HT & LT side cables of follwing indoor/outdoor transformer of capacity 50 KVA to 500 KVA and earth strip from body and neutral of transformer mounted on two pole/four pole structure/staging/sub stn and taking down the transformer manually/using mechanical means and lifting loading and transportation to MES store yard/GIVEN site for mounting on PCC floor complete making connection in all respects incoming and outgoing earth strip suly secured with clamps and pipes all as specified and diected
M&L point wiring (CONCEALED) for using 1.5 sqmm nominal cross sectional area copper conductor mutimultistranded ,PVC insulated unsheathed , FRLS cables in and including using PVC conduits not les than 20 mm dia and fittings, including pressed steel terminal switch boxes , 3 mm thick bakelite sheet top cover (ISI Marked) fitted with Chromium plated brass screws & washers and 1.5 sqmm nominal cross sectioanl area multi-multistranded copper conductor , FRLS, green PVC insulated unsheathed earth wire and connecting to earth dolly using color code as per IS and making good all disturbed work to match the existing for One light/fan/bell point controlled by one 5 Amps one way switch and all as specified and brass screws, washers etc. complete all as specified.
All as per Item No. 112 here in before but for One three pins 5 Amps switch socket outlet point on independent board
All as per Item No. 112 here in before but for One three pins 5 Amps switch socket outlet point on same board with other switches
Description all as per item No 112 here in before but for 15 amps socket outlet with 2.5 Sqmm Copper incl 2.5 Sqmm PVC insulated copper conductor cable as earth continuity conductor and connecting to common earth dolly complete all as specified and directed.
Description all as per item No 112 here in before but for 15 amps socket outlet with 4 Sqmm Copper incl 4.0 Sqmm PVC insulated copper conductor cable as earth continuity conductor and connecting to common earth dolly complete all as specified and directed.
S & F switch piano ,flush type single pole, one way 5 amp, all as specifed and directed by Engr-in-charge.
S & F switch piano flush type single pole one way 15/16 Amp complete all as specified and directed by Engr-in-charge
Supply and fix in replacement of socket outlet 2 in 1, 3 pin 5 Amps complete.
Supply and fix in replacement of socket outlet 2 in 1, 3 pin 5 Amps and 15 Amps complete.
M & L for celling rose 3 pin/pvc/ polycarbonate insulated body complete all as specified and as directed.
M&L for submain wiring comprising single core ,2 Runs of 10 sqmm nominal cross sectional area multimultistranded copper conductor cable, PVC insulated unsheathed 1100 Volts grade drawing in and including appropriate dia. PVC conduits and conduit fittings/existing concealed PVC conduit and conduit fittings not less than 25 mm dia complete, including provision of 1x6 sqmm nominal cross sectional area multimultistranded copper conductor cable PVC insulated unsheathed 1100 Volts grade as earth wire and using color code as per IS and specified and making good all disturbed work to match the existing complete incl taking down old UNSV sub main all as specified. ( Note :- Extra length of cables/ wire required for connection to MCBs shall not be measured and the rate quoted by contractor for per unit shall be deemed accordingly)
Description all as per item No 122 here in before but ,2 Runs of 6 sqmm nominal cross section and including provision of 1X4.0 sqmm nominal cross sectional area for earth wire complete all as specified and directed.
Description all as per item No 122 here in before but ,2 Runs of 4 sqmm nominal cross section and including provision of 1X4.0 sqmm nominal cross sectional area for earth wire complete all as specified and directed.
M & L cutting chases, pinning in, making god to facings where reuired and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc ; and cutting chases for concealed water tubing or concealed wiring etc, and making good, cutting not exc 10 cm girth in brick walls complete all as directed by Engr-in-charge .
M&L for LED tube light fitting of LED T5 tube lights (6500K) environomental freiendly energy efficient of 18/20 Watt LED including electric connection with PVC copper flexible twin core cable, 1.0 sqmm from ceiling rose to light fitting complete all as specified and directed by Engr-In-charge. Make:Syska or equvalent of Havells/Crompton Greaves/ Philips/Wipro/Polycab as recommended by Engr-Incharge and approved by GE.
M&L for LED Batten with LED tube light integrated LED channel of capacity 10 Watt white colour complete all as specified and directed by Engr-In-charge. Make: Bajaj BCLSB 10WH or equvalent of Havells/Crompton Greaves/ Philips/Wipro/Syska/Polycab as recommended by Engr-Incharge and approved by GE.
S & F Geyser storage type, electric driven of capacity 25 Ltrs 5 star rating, with 8 bar pressure with standing ,rust proof, rust proof fire retardant cable adj thermostat anti corrosion protective device inner tank mild steel with glass lined coating including PVC connections and grouting of bolts with nut of suitable size including cement work for make good the disturbed surface etc complete all as specified and as directed .Make:: Bajaj cat No Caldia or equavalent in CG, Havells,
Dismantling of existisng unserviceable MCB distribution board and S&F sheet metal enclouser TPN DB (Load Line) having facility to fix MCCB in incomer upto 125Amps and MCBs in outgoing, TPN 8 ways, Double door type complete fitted with bus bars, neutral links, IP-54 protection Isolated Neutral bar,door earthing,cement spill ptorector and blanking plates including making good disturbed surfaces complete all as specified and directed. make- Legrand/L&T Hager/C&S/INDO KOPP/Indo Asian/Standard/Havells
S&F sheet metal enclouser SPN DB having facility to fix MCB in incomer and MCBs in outgoing, SPN 4 ways, Double door type complete fitted with bus bars, neutral links, blanking plates including making good disturbed surfaces complete all as specified and directed. make- Legrand/L&T Hager/C&S/INDO KOPP/Indo Asian/Standard/Havells
S&F MCB SPN 40 Amps, 240 Volts complete all as specified.
S&F MCB SP 6 to 40 Amps, 240 Volts complete all as specified.
Supply and fixing Plug and socket type DB (Functional Unit) 20 Amps capacity with provision of single pole 20 amps MCB, plug top and earth plug, grouted flush to walls complete all as specified. Make-Legrand/L&T Hager/C&S/INDO KOPP/Indo Asian/Standard/Havells Schneider/C&S)
M & L lamp holder, PVC/Polycarbonate type with back plate including with LED lamp of 12 Watt suitable for batten fittings complete, Make- Anchor/SSK/CONA
S&F for PVC flexible pipes 15mm dia (heavy duty) both end socketed 450mm long for hot/cold water.
S&F for copper (CP) hot water pipe 450 mm length (heavy duty) for Geyser, connection with check nut and washer.
Supply and lay GI Pipe medium class including fittings of size 25 mm dia
S & F LED street light luminaitres 20/25 watts with IP66 complete with pressure dia cast aluminium housing with GI pipe bracket made out of 25 mm dia medium grade pipe (60 cm long) bend to shape including fixing arrangement to wall with MS flat 25x3mm-2 Nos by nut, bolts and washers including electric connection with PVC copper flexible twin core cable 1.0 sqmm from ceiling rose to light fitting complete all as specified and directed by Engr-In-charge. Make:Syska max glow series SSK-ST25W-MG or equvalent of Havells/Crompton Greaves/ Philips/Wipro/Polycab as recommended by Engr-Incharge and approved by GE.
Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth of not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick and packed layer of charcoal dust and common salt, connected to galvanised iron earht wire lead of 4 mm dia fixed by means of bolts, nuts and washers of the earth wire galvanised iron or steel and thimbles and other end of the earth wire connected to earthing test point and protected by galvanised iron pipe light grade 40mm dia upto 3m height above ground level and water pipe 20mm dia GI medium grade with socket and plug 30 cm above ground level including earthwork, PCC chamber in PCC (1:3:6) type C-2 using 40mm stone aggregate, cast iron cover, wire meah etc all as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009 complete and all as specified and direcrted by Engr-in-charge Notes :- (i) 20 mm dia GI pipe for watering to be provided with a socket and plug and should be 30 cms above ground level. (ii) GI strip upto DBs earth connection is included in this item. (iii) GI pipe 40 mm dia protection pipe shall be provided upto Ground level.
M & L point wiring (Concealed) with PVC FRLS insulated unsheathed multistranded copper conductor drawn in and incl of size 4.0 Sqmm, 1100V grade in concealed PVC regid conduit, including provn of of 1.2 mm thick pressed steel sunken terminal boxes 60mm deep,suitable lenthand painted with red oxide primer for mounting switches, sockets, fan regulators covered with and including 3mm thick bakelite plastic laminated sheet top cover fixed flush with wall using brass screws & cup washers including 4.0 Sqmm PVC insulated stranded copper conductor as earth continuity wire and connected to common earth dolly with copper lugs inserted in including MS boards complete heavy duty for housing switches, sockets, regulators, bell push etc, complete all as directed for the following.
Supply and fixing Plug and socket type DB (Functional Unit) 20 Amps capacity with provision of single pole 20 amps MCB, plug top and earth plug, grouted flush to walls complete all as specified. Make-Legrand/L&T Hager/C&S/INDO KOPP/Indo Asian/Standard/Havells Schneider/C&S)
M&L for PVC connection cold type & hot type of 15mm bore & 600mm length for connecting main pipe line to the Geyser with PTMT nuts complete all as specified and directed.
S & Laid G I Pipe 15 mm 'Medium Grade with all fittings complete all as specified & directed by Engr-in-charge.
S & Laid G I Pipe 20 mm 'Medium Grade with all fittings complete all as specified & directed by Engr-in-charge.
Supply and fixing Stop valve cast copper alloy fancy type, chromium plated with long shank and cup (Concealed type) with crutch or butterfly handle screwed down high pressure screwed lfor Iron pipe or brass feuurle for 15mm bore pipes complete all as specified .
Supply and fixing Bib tap cast copper alloy with crutch or butterfly handle screwed down high pressure screwed for iron pipe or brass ferrule for 15mm bore pipes complete all as specified.
M&L for submain wiring comprising single core ,2 Runs of 6 sqmm nominal cross sectional area multimultistranded copper conductor cable, PVC insulated unsheathed 1100 Volts grade drawing in and including appropriate dia. PVC conduits and conduit fittings/existing concealed PVC conduit and conduit fittings not less than 25 mm dia complete, including provision of 2x6 sqmm nominal cross sectional area multimultistranded copper conductor cable PVC insulated unsheathed 1100 Volts grade as earth wire and using color code as per IS and specified and making good all disturbed work to match the existing complete incl taking down old UNSV sub main all as specified. ( Note :- Extra length of cables/ wire required for connection to MCBs shall not be measured and the rate quoted by contractor for per unit shall be deemed accordingly)
S&F as in replacement MCB distribution board double Door of sheet metal Single pole and neutral 8 way with 200 amps rated bus bar 240 volts complete.
S & F MCB SPN 63 Amp,240 volts complete all as specified and directed by Engr-in-charge.
S&F sheet metal enclouser TPN DB (Load Line) having facility to fix MCCB incomer upto 125Amps and MCBs in outgoing, TPN 8 ways, Double door type complete fitted with bus bars, neutral links, IP-43 protection Isolated Neutral bar,door earthing,cement spill ptorector and blanking plates including making good disturbed surfaces complete all as specified and directed. make- Legrand/L&T Hager/C&S/INDO KOPP/Indo Asian/Standard/Havells
Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth of not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick and packed layer of charcoal dust and common salt, connected to galvanised iron of 4 sqmm SWG earht wire fixed by means of bolts, nuts and washers of the earth wire galvanised iron or steel and thimbles and other end of the earth wire connected to earthing test point and protected by galvanised iron pipe light grade 40mm dia upto 3m height above ground level and water pipe 20mm dia GI medium grade with socket and plug 30 cm above ground level including earthwork, PCC chamber in PCC (1:3:6) type C-2 using 40mm stone aggregate, cast iron cover, wire meah etc all as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009 complete and all as specified and direcrted by Engr-in-charge Notes :- (i) 20 mm dia GI pipe for watering to be provided with a socket and plug and should be 30 cms above ground level. (ii) GI strip upto DBs earth connection is included in this item. (iii) GI pipe 40 mm dia protection pipe shall be provided upto Ground level.
S & F GI tube light grade galvanised of size 50 mm with all fitting and fixed to wall and celling or laid in floors for cable protection complete all as specdied and directed by Engineer-in- Charge.
M&L for Boring hole across the Road/plinth/hardstanding/path/drain/pavement etc., suitable for inserting HDPE/GI pipe of upto 100mm dia bore pipe for 0.4 mpa working pressure for cable passing without damaging existing Raod/path/hardstanding/floor by trenchless technology or manual using necessary equipment complete all as specified and directed.
Supplying, laying, jointing and testing XLPE PVC insulated heavy duty multi stranded armoured and PVC sheathed LT cable 1100 volts grade with aluminium conductor cross sectional area 35 sqmm 3.5 core conforming to IS- 1554 laid in trenches/ ducts/ along poles/ through pipes including provision of cable gland/aluminium lugscomplete all as specified & directed by Engineer-in- charge. Note: Excavation & earth work shall be measured & paid separately under appropriate item of this Schedule.
S&F Exhaust fans 300 mm sweep (heavy duty) 230/240 volts single phase with self closing louvers GI off mode protection against birds etc and provision of cutting of walls suitabully for fixing exhaust fan and necessary plastering and making good the disturbed surface to match with existing complete all as specified. Make: Havells ventilair DB 300 mm or equvalent of Orient/Usha/
M & L point wiring Concealed with PVC FRLS insulated unsheathed multistranded copper conductor drawn in and incl of size 1.5 Sqmm, 1100V grade in concealed PVC regid conduit, including provn of of 1.2 mm thich pressed steel sunken terminal boxes 60mm deep,suitable lenthand painted with red oxide primer for mounting switches, sockets, fan regulators covered with and including 3mm thick bakelite plastic laminated sheet top cover fixed flush with wall using brass screws & cup washers including 1.5Sqmm PVC insulated stranded copper conductor as earth continuity wire and connected to common earth dolly with copper lugs inserted in including MS boards complete heavy duty for housing switches, sockets, regulators, bell push etc, complete all as directed for the following. One light/Bell/fan point controlled by one way switch 5 Amp. complete all as directed Note: existing disturbed surface area shall be make good by plastering and finishing by putty/white wash as existing is deemed to included into quoted rates.
M&L point wiring for using 1.5 sqmm nominal cross sectional area copper conductor mutimultistranded ,PVC insulated unsheathed , FRLS cables in and including PVC surface conduit and fittings , including pressed steel terminal switch boxes , 3 mm thick bakelite sheet top cover (ISI Marked) fitted with Chromium plated brass screws & washers and 1.5 sqmm nominal cross sectioanl area multi-multistranded copper conductor , FRLS, green PVC insulated unsheathed earth wire and connecting to earth dolly using color code as per IS and making good all disturbed work to match the existing and all as specified and brass screws, washers etc. complete for One light/fan point controlled by one 5 Amps one way switch all as specified.
M&L point wiring for using 1.5 sqmm nominal cross sectional area copper conductor mutimultistranded ,PVC insulated unsheathed , FRLS cables in and including Surface PVC casing and caping and fittings, including pressed steel terminal switch boxes , 3 mm thick bakelite sheet top cover (ISI Marked) fitted with Chromium plated brass screws & washers and 1.5 sqmm nominal cross sectioanl area multi-multistranded copper conductor , FRLS, green PVC insulated unsheathed earth wire and connecting to earth dolly using color code as per IS and making good all disturbed work to match the existing and all as specified and brass screws, washers etc. complete for One light/fan point controlled by one 5 Amps one way switch all as specified.
M/s GURFATEH BUILDERS
Aggarwal brothers and company
SHRI SHYAM CONSTRUCTION CO.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .