Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.4 LAccepted-AOC 01 ENTERPRISES | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹27.0 L+₹4.2 L (18.5%)Rejected-Finance MCB Z 2 13519 ST NO 4 GREEN AVENUE BATHINDA 151001 PB | BATHINDA | BATHINDA | PUNJAB | 151001 | L2 | Rejected-Finance Quoted other than lowest rate | |
| 3 | L3₹27.3 L+₹4.5 L (19.8%)Rejected-Finance | L3 | Rejected-Finance Quoted other than lowest rate | |
| 4 | L4₹28.6 L+₹5.7 L (25.2%)Rejected-Finance H NO 18 SHEET NO 5 A KATIA COLONY NAMDEV MARG BATHINDA 151001 PB | BATHINDA | BATHINDA | PUNJAB | 151001 | L4 | Rejected-Finance Quoted other than lowest rate | |
| 5 | L5₹29.5 L+₹6.7 L (29.2%)Rejected-Finance | L5 | Rejected-Finance Quoted other than lowest rate |
Tender Value
₹32.5 L
EMD Value
₹65,000
Closing Date
22 Jan 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SH ASHOK KUMAR IDSE
GE NORTH BATHINDA MIL STN PIN 151004
SPL REPAIR OF SINGLE OFFRS ACCN BLDG NO. P-52 UNDER AGE BR-III AND AGE E/M OF GE NORTH BATHINDA AT BATHINDA MIL STN
2021_MES_497524_1
8936/NIT-74/21-22
Open Tender
Civil Works
Item Rate
180 days
GE NORTH BATHINDA MIL STN
Class D category a(i)
8 documents required · 8 mandatory
₹500
GE NORTH BATHINDA
₹65,000
Yes
8 Feb 2022
27 Dec 2021
24 Jan 2022
27 Dec 2021
22 Jan 2022
10 Jan 2022
27 Dec 2021 - 3 Jan 2022
60 days
Amount
SCHEDULE 'A' B/R Works
Taking down chowkhats or frames with shutters (without taking off shutters from the frames, wooden/PVC doors/steel ventilator) area not exceeding 1.50 sqm each and removing from site including cutting holes for removal of old rusted hold fast and prepare the surface for new hold fast complete all as specified and as directed by Engineer-in- charge.
Supply and fixing solid PVC door frame of size 50mm x 47mm made out 5mm thick plain clour PVC sheet reinforced with MS square tube including painting of edges to match with sheet, all as specified & shown in relevant drawing of item No. 8095 in MES Schedule SSR-2020 (Part-II), fixed in opening complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing factory made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, with wood free EPS, door to be fixed to frame with 3 Nos extruded brass butt hinges (with S/S hinge pin) B-11 type, bright polished of size 100mm and fixing with 32mm long steel screws drilled suitable to pass through both the walls of the MS tube complete all as specified in SSR (Part-I, specifications) & shown in relevant drawing of item No. 8101 and 8103 in SSR (Part-II, rates) complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing PTMT barrel tower bolt, 150mm long complete all as specified & directed by Engineer-in-charge.
Supply and fixing PTMT butt hinges, 100mm complete all as specified & directed by Engineer-in-charge.
Supply and fixing PTMT Handle, 150mm long complete all as specified & directed by Engineer-in-charge.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) area exceeding 1.50 sqm but not exceeding 4 Sqm each and removing from site including cutting holes for removal of old rusted hold fast and prepare the surface for new hold fast complete all as specified and as directed by Engineer-in- charge.
Supply and fixing factory made 125 x 60mm pressed steel frames, thickness of sheet 1.25mm for doors with one or more rebates including supply and fixing necessary lugs and lock strike plate, etc. , including fixing only butt hinges suitable Nos as directed for each leaf, complete all as specified and as directed by Engineer-in- charge. Note : - (i) Butt hinges shall be measured and paid separately under appropriate item of BOQ as supply only.
Supply and fixing factory made 75 x 60mm pressed steel frames, thickness of sheet 1.25mm for doors with single rebates including supply and fixing necessary lugs and lock strike plate, etc. , including fixing only butt hinges suitable Nos as directed for each leaf, complete all as specified and as directed by Engineer-in- charge. Note : - (i) Butt hinges shall be measured and paid separately under appropriate item of BOQ as supply only.
Material and labour for PCC (1:3:6), type C-1 using 20 mm graded stone aggregate as in coping/packing around chequered tiles/interlocking tiles/PCC jalli/chowkhat & similar work etc complete all as specified and as directed by Engineer-in-charge.
Taking down wooden shutters only of any description area exceeding 1.0 sqm and not exceeding 2.0 sqm each and refixing in same opening after necessary easing, adjustments, minor repairs etc all as specified and as directed by Engineer-in- charge.
Supply & fixing factory made plain framed panelled shutters (two panels as approved), 35mm thick of 2nd class hard wood with lock rail and panel inserts of 12mm veneered particle board with commercial veneering on both faces. The size of rails and styles as per IS-1003 (Part-I), kiln seasoned as per IS-1141 and chemically pressure treated as per IS-401, including 2nd class soft wood kail beading 20mm wide tapering from 10mm to 5mm on one side and also fitted to chowkhat complete all as specified and as directed by Engineer-in- charge. Note : - (i) The sutters shall be brought at site without primer and same shall be applying at site as per direction of Engineer-in-charge. Primer shall be measured paid separately under appropriate item (painting) of BOQ.
Supply & fixing factory made glazed and skeleton shutter, 35mm thick of 2nd class hard wood open rebated (two panels as approved) and prepared to receive glass, gauge etc, without sash bars, edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass, etc. Sizes of members as specified in SSR Part-I, Section 8 and fitted to chowkhats, menbers shall be kiln seasoned as per IS-1141 and chemically pressure treated as per IS-401 complete all as specified and as directed by Engineer-in- charge. Note : - (i) The sutters shall be brought at site without primer and same shall be applying at site as per direction of Engineer-in-charge. Primer shall be measured paid separately under appropriate item of BOQ.
Supply & fixing flush shutter 25mm thick, solid core construction with block board core and plywood face panels, commercial type on both sides as cupboard and kitchen shutter including adhesive for pasting and screws for fixing to timber frame complete all as specified and as directed by Engineer-in- charge.
Supply & fixing galvanized mild steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm fixed with tinned tack or galvanised wire staples complete all as specified & directed by Engineer-in- charge.
Supply and fixing mild steel 300mm long rat tail rod pattern spring including roller and roller plate and fixing to wooden frame with screw complete all as specified and as directed by Engineer-in- charge.
Supply & fixing mild steel barrel tower bolt stove enamelled black with bright bolt 200 mm long, fixed complete all as specified & directed by Engineer-in- charge.
Supply & fixing mild steel sliding door bolts 300mm long, plate type, stove enameled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts washers, four on bolt plate and two on staple plate complete all as specified & directed by Engineer-in- charge.
Supply & fixing mild steel pressed handle of size 150mm, oval type stove enamelled black complete all as specified and as directed by Engineer-in- charge.
Supply and fixing 100mm long Aluminium anodised, hasp & staple, complete all as specified & directed by Engineer-in-charge.
Supply and fixing anodised aluminium handle cast type 150mm long complete all as specified & directed by Engineer-in-charge.
Dismantling boarding, any description, fixed in any position with nails complete all as specified & directed by Engineer-in- charge.
Supply and fixing Particle board, 18/19mm thick, medium density, flat pressed, single layer type or three layer type with BWR type adhesive, fixed with screws to timber frame work complete all as specified & directed by Engineer-in- charge.
Supply and fixing 75mm long, mild steel butt hinges medium weight cold rolled complete all as specified & directed by Engineer-in-charge.
Supply & fixing 140mm long Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, complete all as specified and directed by Engineer-in-Charge.
Supply & fixing anodised aluminium window/ventilator shutter sliding type without sash bars, made out of aluminium section weighing 0.55 Kg/mtr, powder coated (minimum thickness of powder coating not less than 50 micron) including necessary joining cleats, glazing clips, rubber neoprene packing, suitable size of aluminium handles 1 No and provision of interlocking system (size of handle as directed), anodised aluminium snap beading, screws etc including fixing of glass, complete all as specified and directed by Engineer-in-Charge. Note :- Aluminium channel frame/chowkhat frame shall be measured and paid separately under appropriate item of BOQ as supply and fixing. (ii) Glass and other filling material in panels shall be measured and paid separately under appropriate item of BOQ as supply only.
Supply & fixing aluminium anodised frame for partition, door, windows and ventilators with one or more rebates including jointing cleat for fixing etc. and aluminium anodised skelton windows & ventilator shutter fixed with glass or gauge, side hung type without sash bars using standard aluminium section including necessary aluminium grill, jointing cleats, glazing clips, rubber packing anodised aluminium snap beadings screw, anodised aluminium fittings such as handles stainless steel adjustable friction stay hinges etc.complete all as specified including aluminium grills fixed to window frame aluminium anodised wire cloth fixed to aluminium frame all as specified and directed by Engineer-in-Charge. Note :- (i) If aluminium section used other than above mentioned weighing then weight of each section shall be physically ascertained through a board of officers convened by Accepting officer and payment shall be made only after the actual weight at site. (ii) Payment under this item will be make only for the cost of aluminium section, however unit rate quoted shall deemed to include cost of rubber beading, fittings such as handles, SS friction stay hinges and fixing of 5mm thick glass etc. (iii) Supply only 5mm thick sheet glass and aluminium wire cloth be measured and paid separately (iv) Weight of aluminium handle & SS hinges shall not be accounted for payment purpose.
Hacking out old broken glass (any thickness, size, quality or description) from metal frame including punching or drilling out old glazing pins/spring clips, oil putty complete all as specified & directed by Engineer-in- charge.
Supply & fixing and cutting as per size requirement 4mm thick sheet glass ordinary quality in squares/retangular not exceeding 0.5sqm in each pane and fixed in any type of doors / windows / ventilators (openable/fixed type) with fixing material complete all as specified & directed by Engineer-in- charge.
Supply & fixing, 4mm thick frosted eatched (one side) in squares / retangular exceeding 0.5sqm in each pane and fixed with aluminium beads complete all as specified & directed by Engineer-in- charge.
Cutting holes in brick walls built in cement mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required complete all as specified & directed by Engineer-in- charge.
Material and labour for Preparation of new wooden or wood based surfaces of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified & directed by Engineer-in- charge.
Material and labour for preparation of new steel and iron surfaces of any description not otherwise described over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified & directed by Engineer-in- charge.
Material and labour for preparation of kerb stone/concrete surfaces of any description not otherwise described over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of primer complete all as specified & directed by Engineer-in- charge.
Demolition of cement concrete (unreinforced) in ground floor and paving not exceeding 15cm thickness below or above ground level of any description and in any position including removing rubbish material from building and thrown in low lying empty area (as per direcction of AGE/JE) at any distance upto 500 metres from the site complete all as specified and as directed by Engineer-in-Charge
Material and labour for sunken treatment to sunken floor, cleaning the surface by wire brush, rendering to floor and sides with 15mm thick in cement mortar (1:3) including mixing of liquid WPC in mortar @ 200ml per bag of cement of 50kg, finished even and smooth without using extra cement, complete all as specified and as directed by Engineer-in-charge. NOTE:- (i) WPC for mixing in CM shall be measured & paid separately as Supply only.
Supply only integral water proofing compound complete all as specified and as directed by the Engineer-in-Charge. Make : Dr Fixit/Fosroc/BASF/STP
Material and labour for applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2 Kg/Sqm including cleaning surface compound complete all as specified and as directed by the Engineer-in-Charge.
Material & Labour for PCC (1:5:10) type E-2 using 40mm graded stone aggregate as loose filling of sunken floors complete all as specified and as directed by Engineer-in-charge.
Demolition of floor hearth or wall tilling including cement mortar bedding but not backing including removing rubbish material from building and thrown in low lying empty area (as per direcction of AGE/JE) at any distance upto 500 metres from the site complete all as specified and as directed by Engineer-in-Charge
Material and labour for Glazed ceramic coloured tiles of size 350mmx 250mm / 450mmX 350mm// 450mmX 300mm, 7mm to 8mm thick, as in vertical surface set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile including necessary cutting as per site requirement, tiles laid over and including 10 mm thick (Av thickness) bedding layer (rendering) in cement mortar (1:4) complete all as specified and as directed by Engineer-in-Charge.
Material and labour for vitrified ceramic coloured tiles (light shade) 10 mm thick square or rectangular area of each tile not exceeding 0.36 sqm, as in floor, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile including necessary cutting as per site requirement, tiles laid over and including 15 mm thick bedding layer (screed) in cement mortar (1:6) complete all as specified and directed by Engineer-in-Charge.
Material and labour for vitrified ceramic coloured tiles (light shade) 10 mm thick square or rectangular area of each tile not exceeding 0.36 sqm, as in skirting, dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile including necessary cutting as per site requirement, tiles laid over and including 10 mm thick bedding layer (screed) in cement mortar (1:4) complete all as specified and directed by Engineer-in-Charge.
Material and labour for Non Skid ceramic coloured tiles 7 to 8 mm thick square or rectangular area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, as in floor, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile including necessary cutting as per site requirement, tiles laid over and including 15 mm thick bedding layer (screed) in cement mortar (1:6) complete all as specified and directed by Engineer-in-Charge.
Material and labour 18-20mm thick machine cut, granite duly factory grinding and polished (table rubbed and polished) of approved colour for counter sunk wash basin, plateform/cooking plateform or as directed, including screed bed 15mm thick in cement mortar (1:4) (grey cement slurry) including pointing in white cement (1:2) using marble dust with admiture of pigment to match with shade of granite stone slab including cutting as required including cleaning and extra polishing if required complete all as specified and as directed by Engineer-in-Charge.
Material and labour for moulding the edges half round on exposed side (Rounding to edges of stone slabs one edge) of granite/marble as in kitchen shelf, cooking platform, WHB counter shelf, steps, and other similar situations etc complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in repair 450 mm long PVC connection 15mm size with PTMT nuts complete all as specified & directed by Engineer-in-charge.
Supply and fixing in replacement stop valve/angle valve cast copper alloy, fancy type, chromium plated with crutch or butterfly handle, screwed down, screwed both end for iron pipe or for brass ferrule 15mm bore complete all as specified & directed by Engineer-in-charge. Note :- The minimum weight shall be as given in SSR or in relevant IS.
Supply & fixing in replacement cromium plated shower rose 125mm size, with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and as directed by Engineer-in-charge.
Supply and fixing in replacement concealed stop cock cast copper alloy, chromium plated, fancy type, long shank and cup, screwed both ends suitable for 15mm bore iron pipe complete, all as specified & directed by Engineer-in-charge. Note :- The minimum weight of stop valve/stop cock shall be as given in SSR or in relevant IS.
Supply and fixing MS chromium plated, soap tray approximate size 160mmx160mm, including fixing to wall with CP screws and PVC plug complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement bib tap cast copper alloy, chromium plated with crutch or butterfly handle with capstan head, wall flange, screwed down, screwed for iron pipe or for brass ferrule 15mm bore complete all as specified & directed by Engineer-in-charge. Note :- The minimum weight shall be as given in SSR or in relevant IS.
Supply & fixing PTMT grating round 125mm dia with or without waste hole complete all as specified and as directed by Engineer-in-charge. Note :- The minimum weight 50gm
Supply and fixing in repair drapery curtain rod 19/20mm dia, fabricated out of mild steel pipe with PVC coateing (ABS), wall thickness of pipe not less than 20 guage, including fancy type brackets and pair of decorated end knobs (finials), stop roller etc, fixed to wall for doors and windows cuttings as required and fixing at site complete all as specified and as directed by Engineer-in-Charge.
Taking up or down existing galvanised steel water tubing (GI pipe) 15mm bore including fitting/connection from wall/ceiling/floor/concealed etc. complete all as specified and as directed by Engineer-in-charge.
Taking up or down existing galvanised steel water tubing (GI pipe) 20mm bore including fitting/connection from wall/ceiling/floor/concealed etc. complete all as specified and as directed by Engineer-in-charge.
Re-fixing old serviceable 15mm bore galvanised steel water tubing (GI pipe) including all fittings like elbow, tee, union, socket, reducer etc. in new or old portion/position to walls, ceiling and laid in floor/concealed in walls etc and making good disturbed surfaces of walls complete all as specified and as directed by Engineer-in-charge. (Note :- Old serviceable pipe and fittings obtained from taking up or down (here-in-before) item of this BOQ shall be reused after necessary cleaning internally.
Re-fixing old serviceable 20mm bore galvanised steel water tubing (GI pipe) including all fittings like elbow, tee, union, socket, reducer etc. in new or old portion/position to walls, ceiling and laid in floor/concealed in walls etc and making good disturbed surfaces of walls complete all as specified and as directed by Engineer-in-charge. (Note :- Old serviceable pipe and fittings obtained from taking up or down (here-in-before) item of this BOQ shall be reused after necessary cleaning internally.
Supply and fixing galvanized steel tubing (GI pipe) medium grade 15mm bore ISI marked with all new fittings like elbow, tee, union, socket, reducer etc. and fixed complete to walls, ceiling and laid in floor or concealed in walls including cutting chases in wall (as directed ) and making good disturbed surfaces of walls including cutting and threading of pipe complete all as specified and as directed by Engineer-in- charge.
Supply and fixing galvanized steel tubing (GI pipe) medium grade 20mm bore ISI marked with all new fittings like elbow, tee, union, socket, reducer etc. and fixed complete to walls, ceiling and laid in floor or concealed in walls including cutting chases in wall (as directed) and making good disturbed surfaces of walls including cutting and threading of pipe complete all as specified and as directed by Engineer-in- charge.
Supply & fixing in replacement 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints for drain or rain water fixed along walls with stack clamps made out of FI 50x5mm and 16mm dia round iron stay (interval of 1m) including nut bolt and PCC work, including dismantling/taking down old pipe complete all as specified and as directed by Engineer-in- charge.
Supply & fixing PVC (SWR) bends (any radius) suitable for 110mm bore pipe fixed to walls or laid in floor complete all as specified and as directed by Engineer-in- charge.
Supply and fixing in replacement 10 litres capacity PVC valveless syphonic action type low level flushing cistern white with inlet, ball valve, float, handle including brackets and 32mm dia PVC flush pipe complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement vitreous china wash down water closet pan (pedestal pattern, EWC) white clour (excluding flushing cistern and flush pipe) including connection to drain and to flushing pipe anti syphonage etc., including plastic water closet seat with cover (white clour) closed pattern with flat bottom and mild steel chromium plated or aluminised hinging device including stainless steel chromium plated jet spray with 01 mtr long PVC pipe with CP connector and necessary nut bolts and with necessary CP screws and plug for fixing WC complete all as specified and as directed by Engineer-in- charge.
Supply & fixing in replacement vitreous china wash hand basin oval type under counter, white colour, of size 595mm x 420mm x 200mm excluding taps, but including fancy type 32mm waste coupling and waste pipe, fixing/counter sunked in granite slab, complete all as specified and as directed by Engineer-in-Charge. Note :- Granite slab shall be measured and paid separately under appropriate item of BOQ. Make :- Cat Part CNS-WHT-705 of Jaquar or equivalent (Equivalency approved by GE) in make mentioned in Appx A to PSS-II
Supply & fixing in replacement CP wash hand mixture, fancy type with nut, bolt and washers of 15mm bore pipe, complete all as specified and as directed by Engineer-in-Charge. Make :- Cat Part CON-167KNB of Jaquar or equivalent (Equivalency approved by GE) in make mentioned in Appx A to PSS-II
Supply & fixing in replacement CP wall mixture, three in one, fancy type with telephonic shower for 15mm bore pipe, complete all as specified and as directed by Engineer-in-Charge. Make :- Cat Part CON-273KNUPR of Jaquar or equivalent (Equivalency approved by GE) in make mentioned in Appx A to PSS-II
Supply and fixing hand shower (health faucet) ABS body including 1 meter long 8mm dia flexible tube and including wall hook including taking down old any type shower complete all as specified and as directed by Engineer-in-charge. Make :- Cat Part ALD-CHR-593N of Jaquar or equivalent (Equivalency approved by GE) in make mentioned in Appx A to PSS-II
Supply and fixing Toilet Roll Holder with Stainless Steel Flap, fixed on wall with chromium plated brass screws and PVC plug complete, all as specified and as directed by Engineer-in-charge. Make :- Cat Part AKP-35753PS of Jaquar or equivalent (Equivalency approved by GE) in make mentioned in Appx A to PSS-II
Surface dressing not exceeding 15cm deep in soft/ loose soil including cutting of grass, roots, bushes if any and filling of lower portion with soil obtained from cutting and excavation after sepration of grass, roots, bushes etc and dressing and removing from site all grass, roots and extra soil if any complete all as specified and as directed by Engineer-in-Charge.
Excavation in post holes in soft/loose soil n. exc 0.50 cum each, getting out, returning filling in and ramming earth or broken rubble mixed with earth around, in layers n. exc 25 cm including removing of surplus spoil to a distance n exc 50 mtr and making good the disturbed surfaces all as specified and directed by Engineer-in-Charge.
Excavation in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundations, shafts, wells, cess pits, manholes, for taking out old pipe and laying new pipe line, for laying cable etc. not exceeding 10 Sqm on plan and getting out in soft/loose soil including trimming the sides and forming bottom surfaces to required levels complete all as specified and as directed by Engineer-in-charge.
Returning and filling including spreading, leveling watering and well ramming in layers not exceeding 25cm thick in soft/loose soil complete all as specified and as directed by Engineer-in-charge.
Removing excavated material (surplus soil) to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed by Engineer-in-charge.
Material and labour for 150mm bore (internal dia) salt glazed stone ware (SGSW) drain pipe, grade ‘A’, laid on concrete bed to required slope in trenches, jointing with packed spun yarn and in cement and sand mortar (1:1) and tested, including demolition & breaking up drain pipes, SGSW, AC or reinforced concrete pipe upto and including 150mm bore, complete all as specified and directed by Engineer-in-Charge. (Note : Excavation, earrh work and concrete bed shall be measured and paid separately under appropriate item of BOQ.)
Material and labour for cement concrete (1:3:6), type C2 using 40mm graded stone aggregate as in bed of drain pipe of size 150mm bore (internal) including packing under and haunching against the sides of pipes after they are laid and tested complete all as specified and as directed by Engineer-in- charge.
Material and labour cutting into existing manholes/septic tank for connecting new drain upto 150mm internal dia, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round to 3/4 section) in cement concrete (1:2:4) type B-1 smooth finished, and reforming benching as required complete all as specified & directed by Engineer-in-charge.
Dismantling and disconnecting of existing CI soil vent pipe 100mm bore fixed to wall or laid in floor including all fittings complete all as specified and as directed by Engineer-in- charge.
Dismantling and disconnecting of existing CI soil vent pipe 75mm bore fixed to wall or laid in floor including all fittings complete all as specified and as directed by Engineer-in- charge.
Material & Labour for 75mm bore cast iron soil waste and vent pipe (sand cast pipe ) in any length with or without ears, fixed vertical, fixed in wall with clamps, complete all as specified and as directed by Engineer-in- charge.
Material & Labour for 100 mm bore cast iron soil waste and vent pipe (sand cast pipe ) in any length with or without ears, fixed vertical, fixed in wall with clamps, complete all as specified and as directed by Engineer-in- charge.
Supply & fixing 75mm bore cast iron bends (any radius)/elbo, diminishing pieces or tapers (larger bore measured) with oval access door fixed with cement joints complete all as specified and as directed by Engineer-in- charge.
Supply & fixing 100mm bore cast iron bends (any radius)/elbo, diminishing pieces or tapers (larger bore measured) with oval access door fixed with cement joints complete all as specified and as directed by Engineer-in- charge.
Supply and fixing Cast iron floor trap 75mm bore, with CP grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) using 20mm graded stone aggregate complete all as specified and as directed by Engineer-in- charge.
Supply and fixing for extra joints over cast iron pipe of 100/75mm bore pipes, bend joints etc. provided epoxy joints in lieu of cement joints complete all as specified and as directed by Engineer-in- charge.
Dismantling brick/PCC terracing tiles single layer in roof laid and pointed in cement mortar and removing/disposal off from the site complete all as specified and as directed by Engineer-in-charge.
Demolition of mud in roofs, any thickness, including plastering and leaping (whether full thickness removed or only a part there of) including removing/cutting uprooting grass, vegetations and roots of small plants etc on roof floor and surrounding/parapit wall etc, including removing rubbish material from building and thrown in low lying empty area (as per direcction of AGE/JE) at any distance upto 500 metres from the site complete all as specified and as directed by Engineer-in-Charge
Material and labour for rendering 15mm thick cement mortar 1:4 mixing with WPC @ 3% by weight of cement on fair faces of concrete surfaces on roof slab after wire brushing and cleaning top surfaces of cement concrete all as specified and wire brushing and cleaning top surfaces of tile, lime terracing or cement concrete, including flashings and junction of parapets etc. and surface painting, with a layer of blown bitumen of any penetration applied hot @ 1.70 Kg/Sqm and priming surface and applying APP based polymeric membrane minimum weighing 3 Kg/Sqm and minimum thick 3mm reinforced with polyster non wove fabric (Weight not less than 150 gm/Sqm ) land on primed surface by forced application as treatment (for moderate conditions) complete all as specified and as directed by Engineer-in-charge.
Material and labour for lime concrete terracing using brick aggregate and surkhi as specified in clause 11.11 and laying as specified in clause 11.27 of MES Sch Part-I (2009) minimum thickness at edge 40mm and increasing uniformly towards ridges to obtain a chain slope 1:40, the top shall be trowelled with the addition of jaggery solution and finished smooth complete all as specified and as directed by Engineer-in-charge.
Material and labour for PCC tiles (type A1) of size 25cm x 25cm x 22mm thick with grey cement and no pigment, factory casted (made by using PVC/Rubber moulds on Vibrating Table Machine or machine pressed, top surface even and smooth); laid/bedded on screed bed 15mm thick in cement mortar (1:6), on existing lime concrete surfaces of roof, joints grouted flush in cement mortar (1:3) mixed with liquid WPC @ 200ml per bag of cement of 50kg, complete all as specified and as directed by Engineer-in-Charge.
Material and labour for MAKING benching with PCC (1:2:4) Type B0 using 12.5mm graded stone aggregate as in roof kerb (golla) or mud stops, concave shape, side of roof sheet & similar work etc rounded or chamfered on edges including necessary form work etc complete all as specified and directed by Engineer-in-Charge.
Taking down cement or cement lime plaster from brick wall etc including racking out joints, hacking for key & scrubbing down with water etc complete all as specified and directed by Engineer-in-Charge.
Material and labour for plastering 15mm thick in cement mortar (1:6) on any face of Brick walls or concrete surfaces, finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for rendering/plastering 15mm thick in cement mortar (1:4) on any face of Brick walls or concrete surfaces including mixing of liquid WPC in mortar @ 200ml per bag of cement of 50kg, finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge. (Note :- Water proofing compound shall be measured & paid separately as Supply only)
Material and labour for rendering/plastering 5mm thick in cement mortar (1:3) on any face of ceiling, finished fair and even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
Demolition of brick work or stone / boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, in any description including cleaning and stacking serviceable brick for re use and balance removing rubbish from the site complete all as specified and as directed by Engineer-in-charge.
Material and labour for brick work with sub class ‘B’ old size burnt clay bricks, straight or curved on plan exc. 6 metre mean radius built in cement mortar (1:6) complete all as specified and as directed by Engineer-in-charge.
Material and labour for brick work in half brick thick wall using burnt clay bricks (sub class 'B' old size burnt clay bricks) straight or curved on plan to any radius built in cement mortar (1:4) complete all as specified and as directed by Engineer-in- charge.
Material and labour for 75 mm thick PCC (1:3:6) type C-2 using 40mm graded stone aggregate as in flooring, hard standing, plinth protection/path etc. finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for 75 mm thick PCC (1:3:6) type C-2 using 40mm graded stone aggregate as in flooring, hard standing, plinth protection/path etc. finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
Demolition of cement concrete reinforced of any discription and in any position, like roofs, floors (other than ground floors), beams, staircases, landing, chajjas, fins, facia and similar suspended works, including reinforcement cut as required to facilitate demolition and prepare the surface to casting chajja, slabs, fins, facia etc and including removing rubbish material from site and thrown in low lying empty area (as per direcction of AGE/JE) at any distance upto 500 metres from the site complete all as specified and as directed by Engineer-in-charge.
Material and labour for reinforced cement concrete (1:2:4) (nominal mix) type B-1 using 20mm graded stone aggregate as in chajjas, beams, staircases, landing, fins, facia and similar suspended works complete all as specified and as directed by Engineer-in-Charge. (NOTE : Reinforcement and form work shall be measured and paid for separately under appropriate item of this schedule.
Material and labour for mild steel TMT bars 10mm dia and over cut to length bent to shape, required including cranking, bending spirally for hoping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and as directed by the Engineer-in-Charge. (NOTE : Weight of binding wire shall not be considered for measurement and payment purpose.)
Material and labour for mild steel TMT bars 6 mm to 8mm dia cut to length bent to shape, required including cranking, bending spirally for hoping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and as directed by the Engineer-in-Charge. (NOTE : Weight of binding wire shall not be considered for measurement and payment purpose.)
Material and labour for mild steel TMT bars 5mm dia and over upto and including 10mm dia as in stirrups, spacers and binders cut to length, bent to shape required including bending, cranking etc and binding with and including MS wire (annealed) not less than 0.9mm dia, complete all as specified & directed by Engineer-in- charge. (NOTE : Weight of binding wire shall not be considered for measurement and payment purpose)
Form work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits of foundation and plinth beams and similar work vertical or to better rough finished flat complete all as specified & directed by Engineer-in- charge.
Form work to sides of pillars , posts, struts piers, columns and stanchions and similar works rough finished complete all as specified & directed by Engineer-in- charge.
Form work to chullah hoods, chajjas, trough and similar items including edges rough finished flat surfaces complete all as specified & directed by Engineer-in- charge.
Supply & fixing rotational moulded polyethylene water storage tank white colour of capacity 500 litres (cylindrical vertical, triple layered with closed top), hoisted and fixed in position including making inlet and out let connection and fixing ball valve and gate valve including dismantling/taking down of existing unserviceable PVC water storage tanks of any description complete all as specified and as directed by Engineer-in-charge. (Note :- Float valve and gate valve shall be measured & paid separately as Supply only under appropriate item of BOQ.)
Supply and fixed in repair ball valves, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball (polythene float) complete, screwed suitable for 25mm bore iron pipe complete all specified and as directed by Engineer-in-charge. Note :- The minimum weight of ball valve shall be as given in SSR or in relevant IS.
Supply and fixed in repair gun metal, globe or gate valve (ISI marked), brass cast copper alloy, with iron wheel head, screwed both ends suitable for 20mm bore iron pipes complete all as specified and as directed by Engineer-in-charge. Note :- The minimum weight of gate valve shall be as given in SSR or in relevant IS.
Material and labour for preparation of new plastered surfaces of walls/pillars /cornices by brooming down with using broom/sand papering or by any other means, and preparing the surfaces smooth by applying 3mm thick wall putty upto entire satisfaction of Engineer-in-charge, and after preparing the surfaces applying two coats of oil emulsion distemper (washable), as approved tint/colour by using paint roller brush complete all as specified and as directed by Engineer-in-Charge.
Material and labour for preparing newly plastered or concrete surface of ceiling by sand papering or by any other mean and after preparing the surfaces applying three coats of white wash complete all as specified & directed by Engineer-in- charge
Material and labour for preparation of new plastered surfaces of walls/pillars /cornices by brooming down with using broom/sand papering or by any other mean, washing down with water and applying two coats of cement base paint as per approved tint/colour by using paint brush complete all as specified and as directed by Engineer-in-Charge.
Material and labour for complete removal of existing treatment (any layers of existing treatment ) from walls / pillars / cornices by scraping down with using steel patti wire/ brush / sand papering or by any other mean, remove / scraping down all loose particle, smoke soot, moulds, moss & efflorescent salts, oil & greasy spots etc brooming all dust and washing down with water including applying white cement based putty where required for filling to depressions/nail holes/light cracks etc and to make surface even and smooth and also using sander machine (with provision of dust sucking) on uneven surface to make the surface even and smooth (before and after applying putty as per site situation) upto entire satisfaction of Engineer-in-charge, and after preparing the surface smooth applying two coats of cement base paint as per approved tint/colour with using paint brush/roller brush, complete all as specified and as directed by Engineer-in-Charge. NOTE : - Complete removal /scraping to old existing treatment as directed by Engineer-in-charge, each stage i.e after complete removal and before applying CBP as specified above, the surface shall be passed in writing by the Enigineer-in-charge in site order book.
Material and labour for complete removal of existing treatment (any layers of existing treatment ) from walls/pillars/cornices by scraping down with using mechanical sander machine (including provision of dust sucking) upto entire satisfaction of Engineer-in-charge, brooming and washing down and preparing the surfaces smooth and after that applying average 3mm thick layer (1.5mm thick each in two layer application) of white cement based putty (wall care putty, make Birla JK or equvilent as approved by Engineer-in-charge), after applying putty first and second coat sanding the surface as per requirement by using mechanical sander machine to make the surface even and smooth upto entire satisfaction of Engineer-in-charge and after prepare the surface smooth applying two coats of oil bound distemper (washable) as per approved tint/colour by using paint brush or roller brush complete all as specified and as directed by Engineer-in-Charge. NOTE : - Each stage i.e after complete removal and before applying OBD as specified above, the surface shall be passed in writing by the Enigineer-in-charge.
Material and labour for preparing old plastered or concrete surface of ceiling by sand papering or by any other mean and after preparing the surfaces applying two coats of white wash complete all as specified & directed by Engineer-in- charge.
Supply & fixing in replacement 100 mm cast iron sanitary connection socket to fit out let of WC complete all as specified and directed by Engineer-in-Charge.
Supply & fixing 75mm bore cast iron cowl complete all as specified and as directed by Engineer-in- charge.
Material and labour for hard core of broken bricks of gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface complete all as specified & directed by Engineer-in- charge.
Material and labour for 75mm thick cement concrete ( 1:4:8), type D-2 using 40 mm graded stone aggregate as in sub base complete all as specified and as directed by Engineer-in-charge.
Material and labour for 100mm thick cement concrete ( 1:4:8), type D-2 using 40 mm graded stone aggregate as in sub base complete all as specified and as directed by Engineer-in-charge.
Supply & fixing 3mm thick, 22mm wide glass dividing strips inserted in position to the required design/ pattern all as specified & directed by Engineer-in- charge
Supply only fine sand without silt (Fazilka/Zera or any other approved sources) for filling under interlocking tiles/in trenches for cable protection, interstices etc complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing 60 mm thick (M35 grade) precast interlocking tile/paving block factory casted (made by using PVC paver mould / Rubber paver moulds on Vibrating Table Machine) using grey cement and no pigment, shape haxagon / trigular / zigzag / I-shaped etc, as directed, prepolished & preglazed, specification as per relevant IS, having compressive strength not less than 350 Kg/ Sqcm, laid over sand upto required thick layer and filling the interstices etc complete all as specified and as directed by the Engineer-in-Charge. Note : - (i) Sand for filling shall be measured & paid separately as Supply only but labour for spreding leveling shall be included in the unit rate of this item)
Material and labour for PCC (1:3:6), type C-1 using 20 mm graded stone aggregate as in coping/packing around chequered tiles/interlocking tiles/PCC jalli & similar work etc complete all as specified and as directed by Engineer-in-charge.
Material and labour for PCC (1:3:6), type C-2 using 40 mm graded stone aggregate as in foundation filling and mass concrete, bed block, for embedded fencing posts & similar work etc including form work complete all as specified and as directed by Engineer-in-charge.
Material and labour for PCC (1:4:8), type D-2 using 40 mm graded stone aggregate as in foundation, filling and mass concrete etc. complete all as specified and as directed by Engineer-in-charge.
Material and labour for reinforced cement concrete (1:2:4) (nominal mix) type B-1 using 20mm graded stone aggregate as in foundations including rafts, footings, foundation beams, plinth beams, bases of columns etc. complete all as specified and directed by Engineer-in-Charge. (NOTE : Reinforcement and form work shall be measured and paid for separately under appropriate item of this schedule.
Material and labour for reinforced cement concrete (1:2:4) (nominal mix) type B-1 using 20mm graded stone aggregate as in columns, pillars, piers, posts and struts complete all as specified and directed by Engineer-in-Charge. (NOTE : Reinforcement and form work shall be measured and paid for separately under appropriate item of this schedule.
Material and labour for Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc.. n exc 10 kg each brackets, conforming to Fe.290.Gde-E-165 (Brackets over 10 kg each to be measured under 'Structural Steel'), complete all as specified and directed by Engineer-in-Charge.
Material and labour for dholpur stone 16 to 18mm thick cladding gang saw cut with machine cut edges, uniform colour of each stone size exceeding 0.25 Sqm area and not exceeding 0.5 Sqm fixed with and including one number SS clamps (grade-202) of flat 30mm x 2mm, 150mm long made to shape in each slab, making V groove at top and bottom of stone and drilling hole for hold fastener, polishing, rubbing & including silicon treatment including 10mm thick back coat, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed by Engineer-in-charge.
Supply and fixing Pre- painted galvatume aluminum zinc coating GI based plain steel sheet 0.50mm thick, any colour having tensile strength of 550 Mpa as in ridge (including cutting and bent to shape), roof covering, fixed with self tapping screws complete all as specified and as directed by Engineer-in-charge.
Material and labour for Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated), complete all as specified and directed by Engineer-in-Charge.
Material and labour for rolled mild steel as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc, complete all as specified and directed by Engineer-in-Charge.
Material and labour for precast cement concrete (1:2:4) type B1 using 20mm graded stone aggregate in kerb stone, quoin blocks, copings, kneelers, apex stones, boundary pillars, bed plates, bonders ( for stone walling), etc with plain fair faces, chamfers, weatherings, slightly rounded or chamfered angles and throating etc including form work and laying and setting in cement mortar (1:4) including dismantling of old damaged kerb stone and removing the debris from site all as directed.
SCHEDULE 'A' ELECTRIFICATION WORKS
Taking down carefully/aluminium point wiring (light, fan, socket or power point ) complete including fitting such as hylem sheet switches, ceiling rose, pendent holder sockets, regulator except concealed conduit and sunken boxes etc and making good distrubed surfaces of wall and floors etc to match with the existing all as specified and directed by Engineer-in-charge.
Material and labour for concealed point wiring complete modular type with 1.5 sqmm (nominal cross section area ) FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked ) drawn through and including PVC rigid conduit 20mm dia( heavy duty) with all fittings and all accessories i.e pipe bend pipe hook, elbow, junction box, pressed steel powder coated sunken box of suitable for mounting modular switches and socket, fan regulator, for light/fan point controlled by one switch, top cover fixed with brass screws & cup washers including provn of 1.5 sqmm FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc including cutting chases in wall and making good distrubed surface of wall/ceiling/floors etc by using CM (1:3 ) to matching with existing surface complete all as specified and as directed by Engineer-in-charge. Make of cable and conduit :- Havellls/Dcab/Finolex/Anchor
All as per item No 141 here in before but for socket outlet 5 pin 5 Amp on same board complete all as specified and directed.
All as per item No 141 here in before but for socket outlet 5 pin 5 Amp on independent board but not below the switch board complete all as specified and directed.
All as per item No 141 here in before but for socket outlet 6 pin, 5/15 Amp multi purpose, 2 in 1 on independent board with 2.5 Sqmm cable & including 2.5 sqmm single core multi stranded FRLSH copper earth wire to common earth complete all as specified and directed.
All As per item No 141 in before but for one light point controlled by Two Two way switch all as specified and directed.
Supply and fixing Modular 6 Amps Switch 250 volts AC one way ISI marked. Make:-Anchor/Havells/Legrand/Indoasian.
Supply and fixing Modular 6 Amps Socket 2/3 pin combined 2 module 250 volts AC ISI marked. Make:-Anchor/Havells/Legrand/Indoasian.
Supply and fixing Modular Switch 16 Amps 1 module 250 volts AC ISI marked. Make:-Anchor/Havells/Legrand/Indoasian.
Supply and fixing Modular Socket 6/16 Amps 2 in one 5 pin universal type 250 volts ISI marked. Make:-Anchor/Havells/Legrand/Indoasian.
Supply and fixing Modular 6 Amps, 1 module, Switch 250 volts, two way ISI marked with suitable frame and covers. Make:-Anchor/Havells/Legrand/Indoasian.
Supply and fixing modular bell push 6 Amp complete all as specified and as directed by Engineer-in-charge.
Supply and fixing ceiling rose 3 plate flush type 6 Amp 250V AC topline series with polycarbonate 65 X 50 mm two to three terminal complete all as specified.
Supply and fixing Batten holder 2 Amp 250V AC with skrit ISI marked top line series , polycarbonate cased body of brass with back plate suitable for batten fittings complete including 9w LED bulb all as specified. Make of holder : Anchor/Havells/Legrand/Indoasian/SSK and Make of LED bulb :- Crompton/Philips/Bajaj/Havells
Supply and fixing Modular Fan regulator Electronic step type (1-4), socket type 230- 240 volt complete all as specified. Make:-Anchor/Havells/Legrand/Indoasian.
Supply and fixing Electric / Electronic Bell, ding dong type 230 Volt AC supply complete all as specified. Make : Anchor/SSK /Havells/Legrand.
Supply and fixing wall mounted Retro LED 20 watt, Batten decorative type, appx 4 feet long, pre wired including LED tube light 20W, 6000K with inbuilt driver complete fitting and all other accessories fitting arrangements including electric connection connecting with using flexible copper wire twin core upto ceiling rose/connector including taking down old unserviceable light fittings any type complete all as specified and as directed by Engineer-in-Charge. Make - Cat part No. LT8-20-865-2 of Crompton/Havells/Wipro/Philips
Supply and fixing LED mirror light fiting 9/10 watt, 6000K, lineer & compact with decorative grey end caps, polycarbonate body and ribbrd opal diffuser complete fitting with lamp and all other accessories fitting arrangements including electric connection connecting with using flexible copper wire twin core upto ceiling rose/connector including taking down old unserviceable light fittings any type complete all as specified and as directed by Engineer-in-Charge. Make - Crompton/Havells/Wipro/Philips
Supply and fixing in replacement wall mounted study lamp bi-directional type prewired with lamp holder B22 based suitgable for and including LED lamp 7 watt and making electrical connections including taking down old unserviceable light fittings any type complete all as specified and directed by Engineer-in-Charge.
Supply and fixing wall mounted/surface mounted decorative wall light fixture in cylindrical/Doom profile made up of polycarbonate for and including LED 7 Watt lamp, base B22, complete fitting with LED lamp and all other fixing accessories including electric connection connecting with using flexible copper wire twin core including taking down old unserviceable light fittings any type complete all as specified and as directed by Engineer-in-Charge. Make - Crompton/Havells/Wipro/Philips
Supply and fixing Sleek Pressure die cast aluminium housing/body, heat resistant clear glass, LED lens for wide beam, energy saving, IP65/66 protection, not less than 5700K, better optics for uniform distribution street/Roadway luminaire with high power LED 35 watt complete fitting with driver, LED strip and all other accessories etc, suitable for 40/32mm OD entry for direct mounting on pipe bracket, fixing on poles/along wall with and including brackets made out of GI tubing light grade 40mm dia, 2 metre long bent to shape at 120 degree angle at half metre from bottom (as per sample), fixing with MS clamp (02 Nos) and nut bolts, including before fixing applying two coats of aluminium paint on bracket and clamp over a coat of red oxide primer, including making electric connection with using twin core copper cable of suitable size and including taking down old unserviceable light fitting complete all as specified and as directed by Engineer-in-charge. Make - Cat part No LSTS-35-CDL of Crompton/ BRLEP 35W LED WH of Bajaj / ENDURA PEARL SL35W LED757SASYTOPC of Havells / HLSLD-09-35CWL-R of Halonix
Supply and fixing in replacement (concealed in wall or as directed) factory made DB (made out of CRCA sheet) TPN, 6 Way 433 V (8+12 modules), double door, earth bar, copper bus bar 200 Amp and neutral link, protection class IP-43 suitable for mounting MCCB/Isolator, conforming to IS-8623, BS-5484 dust and vermin proof, including taking down unserviceable old DB any type including MCB etc and including making good disturbed surfaces of walls as necessaty complete all as specified and directed by Engineer-in-charge.
Supply and fixing MCCB of capacity 100 Amp, TPN, 415 volt, short circuit breaking capacity not less than 16KA , thermal magnetic trip, setting 80-100%, Icu-100% Ics confirming to IEC-947, IS-13947, including thimbles, nuts, bolts, washers etc , MCCB fixing in new DB or the existing DB/Panel including making incoming, outgoing connections, incl taking down old unserviceable MCCB complete all as specified and as directed by Engineer-in-charge . Note :- DB shall be measured and paid separately under appropriate item of BOQ.
Supply and fixing in replacement (concealed in wall or as directed) factory made DB (made out of CRCA sheet) SPN, 8 Way 240V, double door, earth bar, copper bus bar 200 Amp and neutral link, protection class IP-43 suitable for mounting MCB/Isolator, conforming to IS-8623, BS-5484 dust and vermin proof, including taking down unserviceable old DB any type including MCB etc and including making good disturbed surfaces of walls as necessaty complete all as specified and directed by Engineer-in-charge.
Supply and fixing MCB SPN 63 Amps, 10 KA 'C' curve 230 V AC, 50 Hz including necessary attachment incl taking down old unserviceable MCB SPN complete all as specified and directed by Engineer-in-Charge.
Supply and fixing MCB SP suitable for 230 volts AC supply 6 to 40 Amps, SP rupturing capacity not less than 10KA, C Curve ISI Marked, 1 Module incl taking down old unserviceable MCB SP complete all as specified directed.
Material and labour for concealed sub main wiring with 6 Sqmm single core (Two run) FRLSH PVC insulated multistrand copper conductor drawn through and including PVC conduit 20mm dia (medium quality ISI marked), on independent circuit from DB and including one run 6 Sqmm FRLSH PVC insulated unsheathed multi strand copper conductor continues as earth wire connected to earth dolly etc. including all fitting arrangement i.e. PVC clamp, rawl plug, screw, terminal/junction box, tee, bend etc. and including cutting of chases in wall, and making good disturbed surfaces of walls as per original complete all as specified and as directed by Engineer-in-charge. Note :-Three run of 6 sqmm copper wire and one run conduit shall be measured as one RM length for payment.
Material and labour for concealed sub main wiring with 4 Sqmm single core (Two run) FRLSH PVC insulated multistrand copper conductor drawn through and including PVC conduit 20mm dia (medium quality ISI marked), on independent circuit from DB and including one run 4 Sqmm FRLSH PVC insulated unsheathed multi strand copper conductor continues as earth wire connected to earth dolly etc. including all fitting arrangement i.e. PVC clamp, rawl plug, screw, terminal/junction box, tee, bend etc. and including cutting of chases in wall, and making good disturbed surfaces of walls as per original complete all as specified and as directed by Engineer-in-charge. Note :-Three run of 4 sqmm copper wire and one run conduit shall be measured as one RM length for payment.
Supply and fixing (concealed in wall or as directed) single pole and neutral sheet metal enclosure (AC Box/Gyeser) with a two pin and earth plug and socket complete with one single pole MCB of capacity 32 Amps, 240 volts, AC supply complete all as specified and directed by Engineer-in-Charge.
Supply and hanging/fixing in replacement ceiling fan 1200 mm sweep in white/off white colour, 50watt, copper winding, 3 Blade, single phase, 230 volts 50 Hz double ball bearing, energy saver/energy-efficient, alongwith hanging rod (length as per site requirement or as directed by Engineer-in-charge), canopy (lower and upper), rubber real, nut bolts, lock pin etc. including making electrical connection with flexible round twin core multi strand copper cable suitable size complete all as specified and as directed by Engineer-in-Charge. Make and cat part :- Entrust 50 of Crompton / Energia of USHA / ES 50 of Havelles / Electra 50 of Bajaj Note :- (i) Srl Number of ceiling fan and 'GE North BTD' shall also be writing on fan with red colour permanent marker, cost for the same shall deemed to be included in the quoted unit rate, nothing shall be paid extra on this account, Srl number will be issued by Engineer-in-Charge. (ii) Ceiling fan installed/hanging at site as directed by Engineer-in-charge (from market to AGE E/M store/AGE E/M store to sites /Location, all conditions will be the responsibility of contractor and nothing extra will be admissible on this account (iii) Old rusted and outdated ceiling fans deposited to MES store.
Supply and fixing in replacement exhaust fan 300 mm sweep (BEE, 5 star rated) with louvres, 230V, single phase AC supply, hanging on wall with 4 Nos steel fastners 10mm dia 100mm long and making good the disturbed surface as per existing surfaces, and connection to fan with suitable flexible twin core round copper wire complete all as specified and directed by Engineer-in-Charge. Make - Usha / Bajaj / Khaitan / Orient / Crompton / Polar Note :- (i) Srl Number of exhaust fan and 'GE North BTD' shall also be writing on fan with red colour permanent marker, cost for the same shall deemed to be included in the quoted unit rate, nothing shall be paid extra on this account, Srl number will be issued by Engineer-in-Charge. (ii) Exhaust fan installed/hanging at site as directed by Engineer-in-charge (from market to AGE E/M store/AGE E/M store to sites /Location, all conditions will be the responsibility of contractor and nothing extra will be admissible on this account. (iii) Old rusted and outdated ceiling fans deposited to MES store.
Taking down existing Gyesers from site before the work of building tiles/plastering and refix the same after completion of tiles/plastering work including painting of gyesers and fixing arrangements and testing of required for proper functionality & including electric/earth connections and carrying out grouting & complete installations with mounting bolts, nuts including testing after installation complete all as specified and directed by Engineer-in-Charge.
Material and labour for Earthing complete with galvanised iron earth plate electrode of size 60cm x 60cm x 6.3mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including earth continuity GI wire 4 mm (upto test point from earth plate i.e. 7.5m min) by means of GI bolts/nuts/washers and including protected by 15mm dia GI light grade protection pipe from earth plate to test point, including making of test point. Earth plate shall be surrounded by packed layer of char coal/coke & salt all around bottom and top with alternative layer. 20mm GI light grade pipe for watering (should be 10cm above GL) and including socket, plug, funnel, wire mesh, RCC cover and (including steel for cover) PCC (1:2:4) type B1 (using 20 mm graded stone aggregate) as in earthing pit including necessary form work, excavation & earth work, all as specified & shown in electrical plate No. 3 of SSR (Part – I) including taking out/dismantling old unserviceable earthing system complete all as directed by Engineer-in-charge. Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner.
Supply and laying XLPE LT Cable of size 50 Sqmm, 4 core, 1100 Volt grade heavy duty with XLPE insulated, stranded aluminium conductor served with an inner sheathening of PVC tape armoured with Galvanized steel strip or wire and over all PVC Sheathed stranded conductor conforming to IS- 7098 (Part-I) with latest amendments laid in trenches/fixed to wall/pole/laid in floor including necessary connections and suitable size of thimbling, including taking down old unserviciable cable, complete all as specified and as directed by Engineer-in-charge. Note :- (i) Excavation, earth work, sand cushioning, brick protection, cutting of road and pipe shall be measured & paid separately under appropriate item of this Schedule.)
Supply and laying Best quality, locally available, sub class ‘B’ bricks (Old Size) for cable protection cover, laid flat and dry in trenches over the cable , perpendicular to the direction of cable complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing/laying GI tubing, light grade, 40 mm bore for protection of cable or earthing lead wire under hardstanding/fixed along poles/wall, laid in in trenches etc complete all as specified and as directed by Engineer-in-Charge.
N.G BUILDERS
R B BUILDERS
V K CONTRACTOR
R K GOYAL & COMPANY
G N CONSTRUCTIONS
M/s MITTAL CONSTRUCTIONS
Easyways Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .