Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.4 LAccepted-AOC KALANAHALLI VILLAGE SHIVAKOTE POST HESARAGHATTA HOBLI BANGALORE NORTH BANGALORE 560089 | BANGALORE | BANGALORE NORTH | KARNATAKA | 560089 | L1 | Accepted-AOC Technically and financially qualified as L1 | |
| 2 | L2₹6.9 L+₹56,006 (8.79%)Rejected-Finance 777 CHANDRA MOULESHWARA TEMPEL STREET BANGLORE URBAN KARNATAKA BANGALORE RURAL KARNATAKA 560088 | BENGALURU URBAN | KARNATAKA | 560088 | L2 | Rejected-Finance L2 | |
| 3 | Rejected-Technical 22 21 KALENAHALLI SHIVAKOTE POST HESARAGHATTA HOBL BANGALORE 560089 | BANGALORE | BENGALURU URBAN | KARNATAKA | 560089 | - | Rejected-Technical Not submitted EMD | |
| 4 | Rejected-Technical 9 BEERASWARA NAGAR RBI LAYOUT MAINROAD JP NAGAR 7TH PHASE BANGALORE 560078 | BENGALURU URBAN | KARNATAKA | 560078 | - | Rejected-Technical Income Tax Retrun and Profit and loss account is not duely certified by Charted Accountant and not meeting similar work |
Tender Value
Refer Docs
EMD Value
₹18,500
Closing Date
13 Sept 2024, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
The Director, ICAR-IIHR
ICAR-IIHR, Hesaraghatta Lake pot bengaluru
Repairs to Basic Science, two span polycarbonate houses (Size 10m X12.50m) at IIHR, Hesaraghatta, Bangalore
2024_DARE_822589_1
18-13/2024-25/BS/IIHR-322195
Open Tender
Civil Works
Works
60 days
ICAR-IIHR, Hesaraghatta Lake pot bengaluru
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹18,500
28 Dec 2024
23 Aug 2024
17 Sept 2024
23 Aug 2024
13 Sept 2024
23 Aug 2024
Net house structure
For roof : Providing and fixing 06 mm thick UV Stabilized multiple wall Poly Carbonate Sheet (GE Lexan / IPCL/ Sunlite / Tufflite / Juli / Oinegar or equivalent ) of approved quality with all necessary overlaps, silicon joint sealants, fixtures, anodized bolts, nuts, washers , edge and side aluminium ‘U’ section beadings , and aluminium profiles as per standard spacings , heavy stainless steel self-threading screws etc complete as per directions.
Providing and fixing in position 40% cutoff HDPE woven retractable shade net with all edge and over laps, stitching with plastic tape to the edges as instructed at site including necessary hooks, ss rings, pulley etc (shade net as per approved sample and colour) etc., complete as per directions. For inside polyhouse
Supplying fixing G.I. wire including tightening as required and as instructed at site 1.25mm dia (18 gauge) G.I. wire (60 cm c/c both ways for top to hold shade net as directed at site)
Supplying and laying fixing PVC pipes (6kg/cm2-ISI- Finolex/Supreme/Kisan/Prince/Canara/Ashirvad) with all required collars, bends, elbows, tees, sockets, bush with pvc solvent etc . including providing PVC clamps at every one meter, complete as required at site 75 mm for rain water harvesting from gutter
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe withclamps at 1.00 m spacing. This includes jointing of pipes & fittingswith one step CPVC solvent cement and testing of joints completeas per direction of Engineer in Charge 20 mm nominal dia Pipes
Supplying and fixing in position 100mm thick cross fluted cellulose pad (CELDEK) cool cecl cooling pad with necessary cover pipes for water circulation & back flow drain, all connection including providing 1,000 lts capacity doubled wall PVC tank of make Sintex / Fusion / Kaveri with which has to placed below ground level for proper circulation of water back from cooling pad to the tank, including providing an 0.50 hp 1phase pump with DOL (L&T) starter ISI make with necessary wiring etc, with foot valve gate vale and necessary electrical connection in parallel with draft fans and misting system necessary G.I. pipe and fitting for water circulation, etc., complete
Providing and fixing PVC roof gutter of approved sample and shape as required at sit to be provided with proper slope and fitted properly to purlins, by angles at intervals including with necessary aluminium flats and self driven screws.
Providing plastering to plinth protection and for walls 12 mm cement plaster of mix 1:6 (1 cement: 6 coarse sand)
Finishing walls with Acrylic Smooth exterior paint of required shade new work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) (Asian Tractor / Jonson Nicholson/Berger)
Painting with synthetic enamel paint of approved brand andmanufacture of required colour to give an even shade Two or more coats on old work (Asian Tractor / Jonson Nicholson / Berger)
Electrical work
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required
Supply and fixing of following switch /socket on the existing modular plate and switch box including connection but excluding modular plate etc. as required
5/6 amp switch
15/16 amp switch
3 pin 5/6 amp socket outlet 6
pin 15/16 amp socket outlet
6 Module (200mmX75mm)
Supplying and fixing of 20W LED tube light fittings as required at site.
Supplying and fixing of 200MMExhaust Fan with Louvers as required at site
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator).
8 way, Double door
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required
10 A Single pole
20 A Single pole
25 A Single pole
Supplying and fixing of 100 Amps open type 4 way copper Bus bar box of size 18” X 18” with cable termination by using copper lugs.
Supplying and fixing of 200 Amps open type 4 way copper Bus bar box of size 24” X 24” with cable termination by using copper lugs.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Supplying and laying of fallowing sizes of PVC insulated Alluminium conductor wired Armored UG cable on surface by using necessary fittings for fixing, (including earthing and end termination) etc. as required at the site.
50 Sq mm x 3.5 core
Supplying and fixing of DWC Pipe double walled corrugated high density poly ethylene pipe having corrugation on the outer wall 50 mm and plain surface inner wall of 55 mm sizes conforming to IS14930, with necessary DWC fitting for protection of 1.1 KV grade UG Cable directly in ground at a depth of 2 feet including excavation and refilling on the Soft Soil.
SITC of direct drive 3phase Draft fans for exhaust of 900mm dia with necessary louvers of approved quality and size as suitable for greenhouse as directed by the engineer at site with all necessary control panel having DOL L&T starter and MCB, SPP enclosed in a suitable box with stainless steel mesh, locking facility with all necessary electrical wiring, switches etc complete including integrating with the existing cooling system.
Sri Manjunatha Swamy Electricals
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .