| 1 | L1₹2.2 CrAccepted-AOC COLABA MUMBAI | YAVATMAL | MAHARASHTRA | 445001 | ₹2.2 Cr Quoted ₹2.3 Cr | L1 | Accepted-AOC Being lowest |
| 2 | L2₹2.4 Cr+₹10.0 L (4.39%)Rejected-Finance COLABA MUMBAI | ₹2.4 Cr+₹10.0 L (4.39%) | L2 | Rejected-Finance Other than being lowest |
| 3 | Rejected-Technical 1 128 A SECOND FLOOR MOHAMMADPUR NEAR BHIKAJCAMA PLACE NEW DELHI 110066 | NEW DELHI | NEW DELHI | DELHI | 110066 | - | - | Rejected-Technical Firm did not disclose all running works in hand. Balance work more than five times tendering limit. |
Tender Value
₹2.6 Cr
EMD Value
₹3.4 L
Closing Date
29 Oct 2021, 6:00 pmClosed
CWE (NW) Mumbai
Commander Works Engineer NW Dr Homi Bhabha Road Navy Nagar Colaba Mumbai 05
SPECIAL REPAIR REPLACEMENT OF BER GOODS LIFTS OF GANGOTRI BHAGIRATHI VANDANA AND VISAKHA BUILDINGS AT OUTLAYING AREA INCLUDING (3 YEARS) COMPREHENSIVE MAINTENANCE UNDER GE (NW) NOFRA COLABA MUMBAI ( 3rd Call)
2021_MES_459486_2
8679/CWE(NW)MUMBAI/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE (NW) NOFRA
Class B
8 documents required · 8 mandatory
₹2,000
Yes
GE (NW) NOFRA
₹3.4 L
Yes
1 Dec 2021
9 Sept 2021
1 Nov 2021
9 Sept 2021
29 Oct 2021
14 Oct 2021
9 Sept 2021 - 15 Sept 2021
Amount
Sch 'A' Part - I Dismantling of existing BER Goods lift 2000 Kgs to serve G+ 15 upper floor of any make complete with all accesories such as machine cabin Doors, Guide rails, CWT (counter weight), Car , Rope, Wiring and Control panel etc complete all as specified and as directed by Engineer- in- charge. (Note : Vishakha,Vandana, Gangotri & Bhagirathi bldgs)
Material and Labour for 20 mm thick mirror polished black granite slab, machine cut, mirror polished set on vertical surfaces 300 mm width allround with lift facial elevation including backing in CM (1:3) 15 mm thick and joint filling with white cement with pigment to match with shade of granite for lift archive at all floors complete all as specified and as directed by Engineer- in- charge.
Material and Labour for Earthing complete with galvanized steel earth electrode 600x600x6mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to galvanized earth strip 32 x 6 mm by means of bolts, nuts & washers of galvanized iron or steel up to the test point all as shown in electrical plate No.3 of SSR Part-I connected to lifts including PCC chamber pit, CI cover, GI funnel with wire mesh, GI protection pipe of 50 mm dia for earth lead and 20mm GI pipe for watering , excavation and earth work in any type of soil, filling the pit with charcol and common salt surrounding the earth plate complete including connecting up to machine drive motor and control panel and testing on complete all as specified and as directed by Engineer- in- charge.
Supply and lay aluminium strip of size 32 x 6 mm from test point to lift machine room to be terminated to the control panel, machine and other equipment installed in machine room complete all as specified and as directed by Engineer- in- charge.
Taking down cement plaster, any description on brick or stone or cement concrete walls including raking out joints, hacking for key, scrubbing down with water at height of machine room located at 16th floor of bldg.,complete all as specified and as directed by Engineer- in- charge.
Taking down cement plaster, any description on brick or stone or cement concrete walls including raking out joints, hacking for key, scrubbing down with water at height G + 15) in lift shaft , complete all as specified and as directed by Engineer- in- charge.
Material and labour for rendering 15mm thick cement plaster in cement mortor 1:6 on brick or concrete surfaces, surfaces to be finished even and smooth without using extra cement & height upto 16th floor of bldg.,complete all as specified and as directed by Engineer- in- charge.
Material and labour for PCC (1:2:4) type B1 using 20 mm grade stone aggregate as in cills, other similar bands, holdfasts, bed plates complete all as specified and as directed by Engineer- in- charge.
Material and labour for preparation of old plastered surfaces of wall and applying two coats of white wash complete all as specified and as directed by Engineer-in-Charge
Material and labour for preparation of newly plastered surfaces of wall and applying two coats of oil bound distemper incl primer complete all as specified and as directed by Engineer- in- charge.
Material and labour for preparation of newly plastered surfaces of wall and applying two coats of white wash complete all as specified and as directed by Engineer- in- charge.
Design, supply,install, testing and comissioning of Goods cum Passenger lift having capacity 2000 Kgs or 30 Passenger, Speed 1.0 meter per second, with Gearless Machine, 415 Volts, 3 phase , AC 50 Hz supply, conforming to IS 14665, suitable to serve G+15 upper floors with AC variable voltage and variable frequency drive (VVVF Drive) complete with all standard accessories, simplex automatic and manual dual controlled operation, with/without attendant, center opening doors with door drive (Electric motor drive mechanism), sliding stainless steel doors. automatic rescue device (ARD) system, infra red door sensor in full height of door and built in announcing system without handset (03 Nos one each in car, machine room, and near ground floor landing) complete with the following specification complete all as specified and as directed by Engineer- in- charge. (For Bhagirthi, Gangorti Goods lifts)
(i) Make & Type Traction Gearless with Machine room (ii) Type of lift Goods lift (iii) Load capacity 2000 Kg / 30 Passenger including operator (iv) Speed 1.0 Meter per second (v) Power supply 415 Volts, 3 Phase AC ,50 Hz (vi) Type of drive AC variable voltage & variable frequency (VVVF) (vii) Type of machine Gearless permanent magnet synchronous motor ( including suitable capacity of electrical cabling FRLS with PVC conduits of suitable size and control & MCB). (viii) Car size 2030 mm wide X 2080 mm depth x 2050 mm height (or As per existing size) (ix) Shaft size 2900 mm wide x 2500 mm depth (or As per existing size) ((x) Car and landing doors Telescopic opening , sliding type, stainless steel hair line finish for car and landing at all floor. (xi) Car Enclosures Standard manufacturing with MS Sheet Platform & Stainless steel, hairline finish paneling of 1.5 mm thick, with light fitting LED type of 05 watt -04 Nos, Cabin Fan 300mm sweep with auto start function ( incl wiring with suitable stranded copper conductor cable FRLS), stainless steel false ceiling of 1.2 mm thick, mirror finish, stainless steel hand rail, mirror etc. (xii) Terminal buffers Special spring buffers as per manufacturer's design. (xiii) Door opening 1200 mm wide x 2100 mm height clear opening (xiv) Car & CWT guide Machined Tee for Car 89 x 62 x 16 mm & CWT 70 x 65 x 9 mm or as per existing size at site (or) as per OEM only (xv) Aluminum chequered sheet flooring 5 mm thick (Standard pattern) as per existing cabin size
(xvi) Signal System Combined luminous hall push button with (LCD) TFT hall position indicators with stainless steel hairline face plate at all floors LCD/VFD Car position indicator in car and over load warning in the car. One No. car operating panel with stainless steel hairline with etched borders and luminious button in car. Car direction indicator in car and landing. Battery operated Alarm bell and Emergency light along with inverter of suitable capacity having power back up for a period of minimum 1/2 hour( 30 minutes). Fireman switch at ground floor. All signal fixture and COP will have stainless steel face plate. 3D infra red sensor safety edge of door for entire height. Built in announcing system without hand set. (xvii) Car indicator Shall be proivided with audio announcing system with music. (xvii) Stop and Opening 16 Stops and 16 Openings all on the same side. (xix) Emergency services Automatic Rescue Devices (ARD), to be operating with maintenace free batteries to bring the car to the nearest floor level and auto opening for evacuation of passengers in the event of power failure, b).Overload Relays, Contactor and Fuses, Electrical terminals of high quality, Limit switch with accessories on each floor, Gravity Counter weight as well as over hoisting/ over lowering limit switches for top most position and Phase sequence corrector, C) .Fire emergency operation, d). Emergency operation for power failure, e). Earthquathquake emergency operation.
Design, supply,install, testing and comissioning of Goods cum Passenger lift having capacity 2000 Kgs or 30 Passenger, Speed 1.0 meter per second, with Gearless Machine, 415 Volts, 3 phase , AC 50 Hz supply, conforming to IS 14665, suitable to serve G+15 upper floors with AC variable voltage and variable frequency drive (VVVF Drive) complete with all standard accessories, simplex automatic and manual dual controlled operation, with/without attendant, center opening doors with door drive (Electric motor drive mechanism), sliding stainless steel doors. automatic rescue device (ARD) system, infra red door sensor in full height of door and built in announcing system without handset (03 Nos one each in car, machine room, and near ground floor landing) complete with the following specification and directed by Engineer-in-Charge . (For Vishakha , Vandana Goods lifts)
(i) Make & Type Traction Gearless with Machine room (ii) Type of lift Goods lift (iii) Load capacity 2000 Kg / 30 Passenger including operator (iv) Speed 1.0 Meter per second (v) Power supply 415 Volts, 3 Phase AC ,50 Hz (vi) Type of drive AC variable voltage & variable frequency (VVVF) (vii) Type of machine Gearless permanent magnet synchronous motor ( including suitable capacity of electrical cabling FRLS with PVC conduits of suitable size and control & MCB). (viii) Car size 2000 mm wide X 2140 mm depth x 2280 mm height (or As per existing size) (ix) Shaft size 2860 mm wide x 2550 mm depth (or As per existing size) ((x) Car and landing doors Telescopic opening , sliding type, stainless steel hair line finish for car and landing at all floor. (xi) Car Enclosures Standard manufacturing with MS Sheet Platform & Stainless steel, hairline finish paneling of 1.5 mm thick, with light fitting LED type of 05 watt -04 Nos, Cabin Fan 300mm sweep with auto start function ( incl wiring with suitable stranded copper conductor cable FRLS), stainless steel false ceiling of 1.2 mm thick, mirror finish, stainless steel hand rail, mirror etc. (xii) Terminal buffers Special spring buffers as per manufacturer's design. (xiii) Door opening 1200 mm wide x 2100 mm height clear opening (xiv) Car & CWT guide Machined Tee for Car 89 x 62 x 16 mm & CWT 70 x 65 x 9 mm (xv) Aluminium chequred sheet flooring 5 mm thick (Standard pattern) as per existing cabin size.
(xvi) Signal System Combined luminous hall push button with (LCD) TFT hall position indicators with stainless steel hairline face plate at all floors LCD/VFD Car position indicator in car and over load warning in the car. One No. car operating panel with stainless steel hairline with etched borders and luminious button in car. Car direction indicator in car and landing. Battery operated Alarm bell and Emergency light along with inverter of suitable capacity having power back up for a period of minimum 1/2 hour( 30 minutes). Fireman switch at ground floor. All signal fixture and COP will have stainless steel face plate. 3D infra red sensor safety edge of door for entire height. Built in announcing system without hand set. (xvii) Car indicator Shall be proivided with audio announcing system with music. (xviii) Stop and Opening 16 Stops and 16 Openings all on the same side. (xix) Emergency services Automatic Rescue Devices (ARD), to be operating with maintenace free batteries to bring the car to the nearest floor level and auto opening for evacuation of passengers in the event of power failure, b.Overload Relays, Contactor and Fuses, Electrical terminals of high quality, Limit switch with accessories on each floor, Gravity Counter weight as well as over hoisting/ over lowering limit switches for top most position and Phase sequence corrector, C .Fire emergency operation, d. Emergency operation for power failure, e. Earthquathquake emergency operation. (xx) System backup function Hall call mallfunction recovery system, b. individual signal malfunction recovery system, c. Group management control system, malfunction recovery system, d.individual control malfunction recovery system
Part-II Comprehensive maintenance and repair of fully automatic electrically operated, gearless with machine room, passenger lift with a carrying capacity of 2000 Kgs (Goods Lift) to serve up to G+15 upper floors with speed of 1.0 mtr/Sec with single speed motor and AC single speed motor and AC variable voltage, variable frequency control, automatic levelling device to bring the lift car to exact landing level, simplex automatic operation with or without attendant including telescopic opening stainless steel sliding door and landing door shutters with stainless steel finish and indicators at each floor (04 lift) at out laying area. Note : DLP of 24 month will be start from the date of completion of work (for first & second year) and repair/replacement/ maintenance of spare parts without extra cost by contractor within DLP.
First Year after expiry of defect liability period (i.e for 3rd year)
Second Year after expiry of defect liability period (i.e for 4th year)
Third Year after expiry of defect liability period (i.e for 5th year)
Note 14.00 to 14.03 :- (a)Contractor shall carryout comprehensive maintenance (routine, daily, weekly, monthly, quarterly, half yearly, yearly) as per existing rules a and regulation given by govt and department and maintain all the lifts in seviceable condition 24 Hrs x 365 days without any extra cost during Defect Liability Period of 24 months. (b) After expiry of the defects liabilty period of 24 (months) from the certified date of completion of work , the Government reserves the right to order the contractor to carry out Comprehensive Maintenance services of the lift provided by him in accordance with terms and conditions detailed and specifications enclosed thereoff. In the event of Govt exercising the above right, the terms of comprehensive maintenance service contract shall be for a period of three years. Total period of comprehensive maintenance service contract of the lift shall be for three years from the expiry date of the defects liability period. (c) This contract shall be operative for the period of three years after expiry of defect liability period only for the purpose of Comprehensive Maintenance of the lifts. (d) The Contractor has to carry out the AMC of the Lifts through OEM only (e) The AMC should cover any/all parts of Lifts if its fucntions found defective the same should be repaired or replaced by the OEM as per the timeline covered under norms. (f) Two mechanic shall be available round the clock at lift complaint cell for safe & smooth functioning of the lift. (g) Rewinding of motor if required will be done by the contractor and no extra cost will be given by the department.
(h) The detailed lift mechanics of the firm shall report to the JE Concerned at the Lift complaint cell for receiving the complaints at round the clock daily including sunday and holiday. (j) The detailed lift mechanics shall sign ( Their shift wise) in the attendence register kept with lift cell. (k) Cost of minor spare parts / routine material required for above mentioned maintenance is deemed to be included in the quoted rate except items mentioned here-in-after. No additional cost of spares is admissible for the above maintenance. Decision of the Accepting Officer shall be final & binding regarding minor spares/ routine material (l) Monthly schedule for proper maintenance of lift and necessary documentation including all spare parts required to be replaced during the period shall be as directed by Engineer-in-Charge. (m) All minor spare parts and parts required for repair / replacement for maintenance of lifts to be replaced during AMC at no extra payment. (n) Bidders are to submit license from Govt. of maharashtra for maintenace & erection of lifts issued by chief electrical inspector.
Veer High Tech Solution
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .