Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 CrAccepted-AOC BALIBAZAR TALAP DOOMDOOMA | TINSUKIA | ASSAM | 786151 | ₹1.2 Cr | L1 | Accepted-AOC Work Order Issued |
| 2 | L2₹1.3 Cr+₹14.8 L (12.6%)Rejected-Finance ASSAM RUPNAGAR GUWAHATI 32 | KAMRUP METRO | ASSAM | 781001 | ₹1.3 Cr+₹14.8 L (12.6%) | L2 | Rejected-Finance Accepted |
Tender Value
₹1.1 Cr
EMD Value
₹2.2 L
Closing Date
2 Feb 2022, 2:00 pmClosed
CE, PWD(Bldg) (Health and Education) Assam, Ghy-3
O/O The CE, PWD (Bldg), Assam, Chandmari, Ghy-3
AMCH/ OGP-1 Installation of Hospital Internal Oxygen Pipeline System with Manifold and Requisite Electrical Works related to Installation of 2 Nos. PSA Oxygen Generation Plants of 1000 LPM Capacity each at Pediatric Department and Old Gynecology De
2022_PWBNH_24137_1
CE/TB-III/83/2021/17 Dtd 27th January 2022
Open Tender
Civil Works - Building
Item Rate
30 days
Dibrugarh
Please refer Tender documents.
6 documents required · 6 mandatory
₹3,240
Assam State Road Board Maintenance (Road) Fund
₹2.2 L
Yes
O/O The CE, PWD (Bldg), Assam, Chandmari, Ghy-3
25 Nov 2022
28 Jan 2022
2 Feb 2022
28 Jan 2022
2 Feb 2022
28 Jan 2022
29 Jan 2022
Amount
Civil Work at Old Gynecology Department Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Supplying and filling in plinth with sand under floors,
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources)
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand)
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level Cement mortar 1:4 (1 cement : 4 coarse sand)
Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Ridges plain (500 - 600mm)
12 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand)
15 mm cement plaster on the rough side of single or half brick wall of mix : 1:4 (1 cement: 4 fine sand)
12 mm cement plaster finished with a floating coat of neat cement of mix : 1:4 (1 cement: 4 fine sand)
Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification. Two or more coats on new work
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : Water thinnable cement prime
Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm
over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work
Applying Priming Coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works
Providing and fixing ISI marked M.S. pressed butt hinges bright finished with necessary screws etc. complete: 100x58x1.90mm
Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete: 300x16mm
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. EXTERNAL WORK 40 mm dia nominal bore
50 mm dia nominal bore
Civil Work at DG Shed and Pad related to DRDO PSA Unit Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources)
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources)
Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more.
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand)
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
12 mm cement plaster finished with a floating coat of neat cement of mix : 1:4 (1 cement: 4 fine sand)
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work
Applying Priming Coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group A
Group B
Group C
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 amp socket outlet
15/16 amp switch
6 pin 15/16 amp socket outlet
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 400 Amp, 50KA, FPMCCB
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) cross arm for 4 wire over head line complete with clamps, bolts, nuts and washer etc including drilling of holes for insulator pins etc (as per drawing) and painting with primer and finished paint as required .
Erection of angle iron/ channel iron cross arm on wood/ RCC/ PCC/ steel tubular/ rail pole etc. as required.
Supplying and erection of 11 KV pin insulator complete with large steel head G.I. pin, nuts, washers etc. as required.
Supplying and erection of three piece nonlinear resistor type lightning arrestor suitable for 3 wire, 11 KV overhead lines with rated voltage 9 KV (rms) with a nominal discharge current rating of 5 KA and complete with galvanised clamping arrangement, G.I. bolts, nuts, washers etc. as required.
Erection of all aluminium conductor of 7/1.96 mm to 7/3.10 mm diameter including binding etc. as required.
Supplying fitting and fixing 12 way plastic modular box including cover plate, screw fastener etc. as required complete
Supplying fitting and fixing 2 way plastic modular box including cover plate, screw fastener etc. as required complete
Supplying fitting and fixing LED tube light of 4 ft long 20W HPL make model Neptune plus directlyon wall or ceiling after removing the existing tubefitting as directed by the deptt.
Supplying including fitting fixing of following A.C. Ceiling fan complete with all accessories like down rod, canopy etc. of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department [Without regulator]. Premium model 1400 mm Sweep. (ORIENT PSPO make) /Premium model 1400 mm Sweep SS-390 Deco. Havells make)
Supplying including installation, commissioning of vermin and dust proof totally enclosed, Phosphatised Powder Painted cubical outdoor type double door, floor mounting compartmentalize panel board of size 0.8M X0.9MX 0.40M made of 16 SWG/1.66 mm thick C.R. sheet and 35mm X 35mm X 5mm size angle having 4 no legs at the bottom and C.R. sheet roofing on the top. The panel board is to be erected in 1 : 3 : 6 PCC foundation including excavation of trench and brick soling etc. complete neatly Wiring done with provision for one no 400 A 4pole MCCB as incomer and out going as specified and directed by the deptt. confirming to IP 65 protection comprising of the following electrical items: 1. 40mm X 5mm (4X2) strip copper Bus-Bar 0.20M length each 2. Pilot lamp (R Y B) - 3 nos. (Incoming & Outgoing Switch Gear of reqd. rating will be measured and paid separately)
Supplying including installation, testing and commissioning of Air/Water Cooled Diesel Generator set coupled to suitable alternator of 220/415 V, AC, 1/3-Phase 0.8 p.f. mounted on a 1) M.S. Fabricated base frame.,2) M.S. fuel tank of required capacity.,3) Residual Silencer.,4) AMF Control Panel.5) Suitable batteries with lead.,5) First fill of lube oil.,6) Acoustic Enclosure complete with all accessories as specified and directed by the department conforming to IS comprising the Technical Specification.. as per manufacturer. (RANGE FROM 5 KVA TO 625 KV . Kirloskar green/bliss, Leyland, Volvo Penta, Perkinson, Mahindra, Greaves, Escort engine and Kirloskar, Stamford, Leroy somer or equivalent alternator. 250 3 49400x1700x2050 4660 Kg W/C
Supplying, installation testing and commissioning of the following rating copper wound indoor / out door type transformer complete including the payment to be made to power supply authority for supervision charge, labour charge, cost of L.T/H.T metering etc. (excluding the cost of load security) and making necessary arrangement for charging approval of the sub-station from the competent authority as directed and specified by the department. Transformer should be as per CEA guidelines as ammended up to date upto 200 KVA star rating up to 5 star, above 200KVA as per CEA guidelines for losses along with LV enclosure. 250 KVA,50Hz.11/0.433 KV. Oil filled transformer with Off Circuit tap change.
Supplying, erection and commissioning of the following specification as per IS:2713 : 410 SP hot dip Galvanized Steel tubular pole manufacturing out from electrically welded in 3 (three section having a base plate including providing all required building materials as directed and specified by the deptt. Pole- 410 SP-60
Supplying and erection PSC pole 9.75 metre long, the pole is to be erection in 1:3:6 plain cement concrete foundation of size 1.50 m x 0.45 m x 0.45m having P.C.C base foundation 15 cm x 60 cm x 60cm including edge brick soiling and plastering above G.L. portion (0.30 metre complete with excavation of earth, handling of Surplus Soil, debris etc. to the proper place and refilling etc. as specified and as directed by the department.
Supplying and fitting fixing of galvanised channel of 100 mm x 50 mm x 65 x 2200 mm long complete with clamps ,blots, nuts etc. as required and as directed by the department.
Supplying and fixing of 11 KV 400 A Gang operated switch with all accessories complete as required and as directed by the department.
Supplying and fixing of 11 KV 150 A D.O. fuse set complete as required and as directed by the department.
Supplying including installation of 4' dia. C.I. earth pipe complete as required and as directed by the department.
Supplying and erection of CTPT and trivector energy meter including connection as required by the deptt.
Supply and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV Grade Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988 armoured U.G. cable U.G. cable laid in ground/partially in air (as required for termination over ground including excavation of cable trench up to depth of 75 of 75cm, refilling, protective brick covering, Sand cushioning etc complete handling of surplus spoil, debris et to proper place as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) . 240.00 Sq. mm.3 & 1/2 Core armoured U.G. cable (as per analysis rate)
120.00 Sq. mm.3 & 1/2 Core armoured U.G. cable (as per analysis rate)
95.00 Sq. mm.3 & 1/2 Core armoured U.G. cable (as per analysis rate)
Supplying & laying of PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size unarmoured cable for transformer connection as required complete. 150 sqmm single core
Supplying & laying of PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size unarmoured cable for transformer connection as required complete. 120 sqmm single core
Supplying & fixing of ACSR Raaccon conductor on overhead line as required and directed by the deptt.
Supplying fitting and fixing chain link fencing 2,5 mtr high and 4x4 mtr size including double lead heavy duty iron gate made from 50x6mm MS flate iron and fencing should be made from 10 SWG GI wire 50x50 mesh fitted to MS angle iron post including making PCC foundation to angle iron post as specified and directed by the deptt.
Providing and fixing of Carbon-di-oxide type fire extingushers consisting of welded M.S. cylindrical body, squeeze lever discharge valve fitted with pressure indicating guase internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to IS:15683 finished externally with re enamelled paint and fixed to wall with brackets complete withinternal discahrge. Capacity 4.5 Kg
Supplying and laying 11 KV AB conductor 3 core 50 sqmm including cable kit etc as required by the deptt.
Supplying and laying 11 KV AB conductor 3 core 70 sqmm including cable kit etc as required by the deptt.
Cost of load security. Meter security etc to be paid to APDCL
MEDICAL OXYGEN (O2) SYSTEM- Supply, Installation, Testing & Commissioning of Oxygen manifold extendable type complete with middle frame with chain for individual cylinder (bulk cylinder D type) along with non-return valves for every cylinder and high pressure annealed copper tail pipes with 1 end having brass adapter and the other end suitable for manifold non return valves and manifold will have 10 brass non return valves for individual oxygen cylinder, middle frame with circumferential M.S. Flat duty powder coated all as specified and as directed. Conforming to 3 digit CE Mark with ISO 9001-2015 certified organization. i)1+1
Supply, Installation, Testing & Commissioning of Fully Automatic Digital Gas Control Panel for O2 Features: i) The control panel cover is made using high quality M.S. Duly powder coated. ii) The supply of Gas does not depend on electricity. iii) Display is provided with built-in led to indicate high, normal and low line pressure. iv) Panel cover is fitted with lock to prevent unauthorized access, and can be swing open for maintenance. v) It includes pressure gauge (63mm) that indicated the gas pressure of each header and pipe line distribution pressure. vi) Capable to supply a distribution flow rate in excess of 2500LPM. vii) Manufactured by CE certified/ IS0 9001-2015Organization. vii) Easy usage and maintenance.
Supply, Installation, Testing & Commissioning of Terminal Units (Oxygen Gas Outlets) with probes/ Adaptors as per CE certified/ ISO certified Organization.
Supply, Installation, Testing & Commissioning of Oxygen Flow meter, made with chrome plated brass body. Graduated flow tube and cover made of polycarbonate unbreakable. Adjustable flow by needle valve knob with micrometrical regulation. Humidifier bottle is made of unbreakable polycarbonate material and is autoclavable.
Copper Pipes Solid drawn seamless, de-oxidized, non arsenical, half-hard, tempered and de-greased copper pipe conforming to latest BS EN 13348 :2001 and manufactured as per BS: 2871, 1971 Part I Table X (or as per EN1057). All copper pipes will be de-greased & delivered capped at both ends The pipes will be accompanied with manufacturers LLOYD test certificate i) 12mm OD x 0.7mm Thick
ii) 15mm OD x 0.9mm Thick
iii) 22mm OD x 0.9mm Thick
iv) 28mm OD x 0.9mm Thick
iv)42mm OD x 1.2mm Thick
Supply, Installation, Testing & Commissioning of Isolation Valves with brass body with nickel plate valves operating handle suitable for 15mm OD copper pipe to 76 mm OD copper pipes with brass adapter as per standard specifications all as specified and as directed for the following Isolation Valves: 15mm OD
Supply, Installation, Testing & Commissioning of Area Line Pressure Alarm with displays for various faults indications and capable of monitoring maximum 5 medical gas service by means of pressure switches etc with audible warning with automatic reedit when the gas service returns to normal as per standard specifications all as specified and as directed for the following Area Line Pressure Alarm:- i) Single Line Gas Alarm
ii) Master Alarm
Supplying, Installation, Testing & Commissioning of Pressure Reducing System with two nos Pressure Regulator
Sri Bhaben Bora
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .