| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.1 LAdmitted-Finance 0 AS ENTERPRISES DAYALACHACK HIRANAGAR KATHUA JAMMU KASHMIR 184144 | KATHUA | JAMMU AND KASHMIR | 184144 | L1 | Admitted-Finance | |
| 2 | L2₹31.7 L+₹2.6 L (8.85%)Admitted-Finance DAIRY FARM JUNCTION VIJAY BAUGH ROAD SRI VIJAYA PURAM 744 103 | SRI VIJAYA PURAM | SOUTH ANDAMAN | ANDAMAN AND NICOBAR ISLANDS | 744103 | L2 | Admitted-Finance | |
| 3 | L3₹34.0 L+₹4.9 L (16.7%)Admitted-Finance NEAR UMMAT PUBLIC SCHOOL AUSTANABAD SRI VIJAYA PURAM 744 103 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L3 | Admitted-Finance | |
| 4 | L4₹34.8 L+₹5.7 L (19.6%)Admitted-Finance 01 AALAM E NOOR UI MASJID OLD PAHAR GAON DOLLYGUNJ POLYTECHNIC ROAD SOUTH ANDAMAN ANDAMAN NICOBAR 744103 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L4 | Admitted-Finance | |
| 5 | L5₹34.9 L+₹5.8 L (19.9%)Admitted-Finance | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Sree Tirumala Enterprises L2 | M/s Ramesh Lal L7 | LOOK UP ENTERPRISES L4 | AS ENTERPRISES L1 | Manas Patra Steel Fabrication L3 | M/s Prem Enterprise L6 | V KARTHICK L5 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed. | 0.5 | Qtl | 700 ₹350 Lowest | 1,100 ₹550 | 700 ₹350 Lowest | 3,500 ₹1,750 | 730 ₹365 | 1,050 ₹525 | 750 ₹375 |
| 2.00 | S&F framed work such as grills, gratings etc with ends of bars shouldered and/or riveted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar works like cooler stand conforming to Fe-290, Gde -E-165 complete all as specified and as directed. | 50 | Kg | 240 ₹12,000 | 320 ₹16,000 | 350 ₹17,500 | 250 ₹12,500 | 235 ₹11,750 | 290 ₹14,500 | 230 ₹11,500 Lowest |
| 3.00 | M&L for applying two coat of synthetic enamel paint over a coat of red oxide primer including preparation of new steel surfaces of any description over 10cm width or girth not otherwise described complete all as specified and as directed. | 40 | Sqm | 165 ₹6,600 | 170 ₹6,800 | 190 ₹7,600 | 150 ₹6,000 Lowest | 165 ₹6,600 | 165 ₹6,600 | 160 ₹6,400 |
| 4.00 | Demolition stone slabs and tiles of any description or thickness in floors, aprons etc laid bedded and pointed in any mortar complete all as specified and directed. | 8 | 10 Sqm | 800 ₹6,400 | 2,100 ₹16,800 | 1,000 ₹8,000 | 500 ₹4,000 Lowest | 700 ₹5,600 | 2,000 ₹16,000 | 580 ₹4,640 |
| 5.00 | Demolition of cement concrete (Un-reinforced) in ground floors and pavings n.exc 15cm thick (above or below GL) complete all as specified and directed | 8 | Cum | 900 ₹7,200 | 850 ₹6,800 | 600 ₹4,800 Lowest | 3,500 ₹28,000 | 950 ₹7,600 | 810 ₹6,480 | 1,100 ₹8,800 |
| 6.00 | M&L for 100mm thick PCC 1:4:8 type D2 (Using 40mm graded stone aggregate) as in path finish the top surfaces even and rough to receive top layer complete all as specified and directed | 80 | Sqm | 950 ₹76,000 | 850 ₹68,000 | 650 ₹52,000 Lowest | 1,000 ₹80,000 | 980 ₹78,400 | 825 ₹66,000 | 900 ₹72,000 |
| 7.00 | M&L for chequered cement concrete tiles of size 30cm X 30cm X 25mm thick with grey cement and pigments set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile as in floor over and including 20mm thick screed bed in CM 1:4 complete all as specified and as directed. | 80 | Sqm | 1,700 ₹1,36,000 Lowest | 1,950 ₹1,56,000 | 1,800 ₹1,44,000 | 2,000 ₹1,60,000 | 1,850 ₹1,48,000 | 1,935 ₹1,54,800 | 1,880 ₹1,50,400 |
| 8.00 | Demolition of precast cement concrete block walling built in CM or cement lime Mortar complete all as specified and as directed. | 0.5 | Cum | 800 ₹400 | 1,280 ₹640 | 500 ₹250 Lowest | 15,000 ₹7,500 | 680 ₹340 | 1,250 ₹625 | 1,000 ₹500 |
| 9.00 | M&L precast cement concrete block masonry exc 10 cm width with solid block PCC 1:3:6 type C1 (using 20 mm graded stone aggregate) and setting in cement mortar 1:4 complete all as specified and as directed. | 0.5 | Cum | 12,500 ₹6,250 | 9,980 ₹4,990 | 11,000 ₹5,500 | 15,000 ₹7,500 | 12,500 ₹6,250 | 9,900 ₹4,950 Lowest | 12,000 ₹6,000 |
| 10.00 | Taking down cement plaster of any description including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed | 30 | Sqm | 80 ₹2,400 Lowest | 130 ₹3,900 | 110 ₹3,300 | 200 ₹6,000 | 88 ₹2,640 | 125 ₹3,750 | 90 ₹2,700 |
Tender Value
₹32 L
EMD Value
₹64,000
Closing Date
19 Nov 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Haddo Sri Vijaya Puram
GARRISON ENGINEER HADDO MILITARY ENGINEER SERVICES HADDO SRI VIJAYA PURAM 744102
CERTAIN E/M REPAIRS INCLUDING CIVIL RELATED WORKS AND MISCELLANEOUS REPAIRS AT E/M INSTALLATION UNDER GE HADDO, SRI VIJAYA PURAM
2025_MES_735958_1
8204/E8
Open Tender
Civil Works
Item Rate
270 days
GE Haddo Sri Vijaya Puram
As per tender document
9 documents required · 9 mandatory
₹500
GE Haddo
₹64,000
Yes
29 Dec 2025
17 Oct 2025
26 Nov 2025
17 Oct 2025
19 Nov 2025
31 Oct 2025
21 Oct 2025 - 25 Oct 2025
Amount
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed.
S&F framed work such as grills, gratings etc with ends of bars shouldered and/or riveted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar works like cooler stand conforming to Fe-290, Gde -E-165 complete all as specified and as directed.
M&L for applying two coat of synthetic enamel paint over a coat of red oxide primer including preparation of new steel surfaces of any description over 10cm width or girth not otherwise described complete all as specified and as directed.
Demolition stone slabs and tiles of any description or thickness in floors, aprons etc laid bedded and pointed in any mortar complete all as specified and directed.
Demolition of cement concrete (Un-reinforced) in ground floors and pavings n.exc 15cm thick (above or below GL) complete all as specified and directed
M&L for 100mm thick PCC 1:4:8 type D2 (Using 40mm graded stone aggregate) as in path finish the top surfaces even and rough to receive top layer complete all as specified and directed
M&L for chequered cement concrete tiles of size 30cm X 30cm X 25mm thick with grey cement and pigments set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile as in floor over and including 20mm thick screed bed in CM 1:4 complete all as specified and as directed.
Demolition of precast cement concrete block walling built in CM or cement lime Mortar complete all as specified and as directed.
M&L precast cement concrete block masonry exc 10 cm width with solid block PCC 1:3:6 type C1 (using 20 mm graded stone aggregate) and setting in cement mortar 1:4 complete all as specified and as directed.
Taking down cement plaster of any description including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed
M&L for 10mm thick plaster in CM 1:6 on fair face of concrete surface or brick walls finished even and smooth without using extra cement complete all as specified and as directed.
M&L for preparation of newly plastered surface of wall and applying two coats of oil bound distemper complete all as specified and directed
M&L for 15mm thick plaster in CM 1:4 on fair face of brick walls or concrete surface including mixing of liquid water proofing compound @ 200ml per 50 Kg cement bag, finished the surface even and smooth without using extra cement complete all as specified. (Note: Water proofing compound shall be measured and paid separately)
M&L for preparing newly plastered wall surface and applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/10 Sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 Sqm complete all as specified and directed
M&L for complete removal of existing treatment on plastered wall surface and applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/10 Sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 Sqm complete all as specified and directed
M&L for applying two coats of oil bound distemper after complete removal of existing treatment complete all as specified and directed
Taking down carefully old unserviceable aluminum/ copper point wiring (light, fan, socket or power) complete, including fittings & fixtures such as switches, ceiling roses, lamp holders, pendants, regulators sockets, light fittings, junction/terminal boxes etc; removing from site and making good disturbed surfaces of walls, floors etc., to match with existing surrounding surfaces complete all as specified and as directed.
Taking down existing unserviceable main switches/ distribution boards/Fuse Units of any description alongwith MCBs/MCCBs and making good disturbed surfaces to match with existing surrounding finishes complete all as specified and as directed.
Taking down carefully old unserviceable light fittings only and removing from site complete all as specified and as directed.
Taking down existing unserviceable sub main wiring of any description and making good disturbed surfaces to match with existing surrounding finishes complete all as specified and as directed.
M&L for Point wiring complete with 1.5 Sqmm (nominal area) single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor (with colour coding of Red/Blue/Yellow for phase and Black for neutral), drawn through and including rigid non metallic PVC casing and capping of suitable size (not less than 25mm) and accessories fixed on walls/ceilings etc., including provision of PVC insulated 1.5 Sqmm FRLS cable with copper conductor green in colour for earth continuity and connected to common earth dolly and sunk in CI boxes/pressed steel terminal boxes 60mm deep made out of 1.6mm thick MS sheet duly painted with two coats of anti-corrosive paint outside and with two coats of aluminium paint inside and laminated sheet cover of 3 mm thick on top for housing the switches, socket outlet etc, all as specified and as directed for the following :-
ONE LIGHT/FAN point controlled by one, one way 5 Amps switch.
ONE 5A SOCKET OUTLET point controlled by one, one way 5 Amps switch on independent board.
ONE 5A SOCKET OUTLET point controlled by one, one way 5 Amps switch on same board.
ONE BELL point controlled by one, one way 5 Amps switch.
All as per item Sl No 21 above, but , point wiring with two single core 4.0 Sqmm size cables and one 4.0 sqmm green colour cable as earth continuity conductor for one 3 pin 15 Amps socket out let on independent board complete all as specified and directed.
S & F Switch piano, flush type, single pole one way 5 amps all as directed. Make: Anchor/Cona/Legrand
S & F Switch piano, flush type, single pole one way 15 amps all as directed. Make: Anchor/Cona/Legrand
S & F socket outlet 2 in 1, 3 pin 5 amp, flush type, universal all as directed. Make: Anchor/Cona/Legrand.
S&F Socket outlet 2 in 1, 3 pin, 5 and 15, flush type, universal all as directed. Make: Anchor/Cona/Legrand.
S & F bell push switch, flush type, single pole, 5 Amps, 240 volts AC all as directed. Make: Anchor/Cona/Legrand.
M&L for ceiling rose, three terminal, 65x20mm size, PVC/ Polycarbonate, insulated body, 5A, 240 volts complete all as specified and as directed.
S&F in repairs switch socket combination box type 2 in 1, 5 pin, 5 Amps, flush type,universal complete all as specified and as directed. Make : Anchor/Cona/Legrand
S&F in repairs switch socket combination box type 2 in 1, 6 pin, 5 Amps & 15 Amps, flush type,universal complete all as specified and as directed. Make: Anchor/Cona/Legrand
S&F electric bell, ding dong type, AC, 230 volts complete all as specified and as directed.
S&F in repairs fan regulator, electronic socket two module step type 120W complete as specified. Make : Anchor/Cona/Legrand
M&L for Point wiring complete with 1.5 Sqmm (nominal area) single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor (with colour coding of Red/Blue/Yellow for phase and Black for neutral), drawn through and including rigid non metallic PVC conduit of suitable size (not less than 25mm dia) and accessories fixed on walls/ceilings etc., including provision of PVC insulated 1.5 Sqmm FRLS cable with copper conductor green in colour for earth continuity and connected to common earth dolly and sunk in modular type pressed steel terminal boxes of suitable modules made out of 1.6mm thick MS sheet duly painted with two coats of anti-corrosive paint all over and modular cover plates with frames on top for suitable modules on top for housing switches, sockets etc., all as specified and as directed for the following:- ONE LIGHT/FAN point controlled by one, one way 6 Amps modular switch.
Two light point controlled by one switch 5 Amps one way complete all as specified and directed.
ONE 6A SOCKET OUTLET point controlled by one, one way 6 Amps modular switch on independent board.
ONE 6A SOCKET OUTLET point controlled by one, one way 6 Amps modular switch on same board with other switches.
ONE 6A SOCKET OUTLET point controlled by one, one way 6 Amps switch on independent but below the switch board of light point with cable of 1.5Sqmm size.
ONE BELL point controlled by one, one way 6 Amps modular switch.
All as per item Srl No.33 above, but , point wiring with 4.0 sqmm PVC FRLS insulated multistranded copper conductor suitable for one 3 pin 15 Amps socket out let and one run of 4.0 sqmm cable for earth in green colour on independent board complete all as specified and directed.
S & F for switch modular type, 6 Amps 1 module, 230 volts AC circuit complete all as specified and directed. Make:-Roma (Anchor) / Havells (Crabtree) / Legrand
S & F for socket outlet modular type 1 way 6 Amps, 3 pin, 230 volts AC circuit complete all as specified and directed. Make-Roma (Anchor) / Havells (Crabtree) / Legrand
S & F for switch modular type, 16 Amps 1 module, 230 volts AC circuit complete all as specified and directed. Make-Roma (Anchor) / Havells (Crabtree) / Legrand
S & F Socket outlet 2 in 1 modular type, 3 pin, 6 and 16, universal complete all as specified and directed. Make-Roma (Anchor) / Havells (Crabtree) / Legrand
S & F modular bell push 5 Amps 1 modular 230v, 50Hz AC complete all as specified and directed. Make-Roma (Anchor) / Havells (Crabtree) / Legrand
S & F stepped type modular fan regulator, 2 modular type complete all as specified and directed. Make-Roma (Anchor) / Havells (Crabtree) / Legrand
S & F in replacement of capacitor 2.5mfd, 230 Volts for ceiling fans including taking out old unserviceable one complete all as specified and as directed. Make:- Capco/ Univarsal/ Tibcon/ Epcos
Taking down carefully ceiling fan of any sweep/ cap/ make from its existing position of any height/ loaction after disconnecting from electricity, dismantling blades, opening up for carrying out servicing/over hauling, examining for damaged worn out parts like shaft, ball bearings etc., and applying grease to bearings, assembling back, preparing painted surfaces by cleaning dust, grease etc., and by filling cavities with filler to receive spray paint using synthetic enamel paint of existing shade, fixing up blades and hanging back in position and providing and connecting up with 1.0 sqmm twin core twisted flexible copper conductor of suitable length from connector of fan to ceiling rose and testing complete all as specified and as directed. NOTE: Spare parts like ball bearings, shafts etc shall be replaced only if found damaged and certified by Engineer-in-charge. If spares are replaced, they shall be measured and paid separately as SUPPLY ONLY.
All as per item Sl No 42 above, but, exhaust fan of any sweep/cap/type complete all as specified and directed.
All as per item Sl No 42 above, but, wall mounted fan of any sweep/cap/type complete all as specified and directed.
Taking down of unsv exhaust fan of cap 450 mm sweep of any make from its existing position and rewinding by super enamelled copper winding wire of suitable gauge and size with Garware insulating paper, insulating varnish and oven drying for requisite insulation values including necessary PVC sleeves lead wires and testing after assembling in position in exhaust fan complete all as specified and as directed.
All as per item No 45 above, but , exhaust fan of any size/make/cap (250 to300 mm sweep) complete all as specified and as directed.
All as per item No 45 above, but , wall mounted fan of any size/make/cap complete all as specified and as directed.
Suplly only ball bearing suitable for ceiling fan with bearing No. 6201/6202 complete all as specified and as directed.
Suplly only shaft suitable for ceiling fan 1200mm/1400mm sweep complete all as specified and as directed.
Suplly only exhaust fan blade set of 250/300/380mm sweep complete all as specified and as directed.
Suplly only wall mounted fan blade set of 300/400mm sweep complete all as specified and as directed.
Taking down carefully ceiling fan of any make, size from its location, handed over to AGE E/M store yard without any damage
S & F Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC).
S & F high speed air ventilating fan 300 mm sweep single ph, 230 volt, steel body with louvers incl all fixing arrangement complete all as specified and directed.
S & F air ventilating fan 200 mm sweep single ph, 230 volt, PVC body with louvers incl all fixing arrangement complete all as specified and directed.
M&L for Sub main wiring complete with four runs (3P+1N) of 10.0 Sqmm single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor (with colour coding of Red/Blue/Yellow for phase and Black for neutral) and one run of 10.0 Sqmm single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor as earth wire green in colour including lugs, drawn through and including 32 mm wide rigid non-metallic PVC casing and capping and its accessories (OR) 25 mm dia PVC conduit and conduit accessories fixed in concealed or on surface of wall/ceiling/roof/ floor complete all as specified and as directed.
All as per item Sl No 56 above, but , sub main wiring with four runs (3P+1N) of 6.0 Sqmm single core duly earthed with one run of single core cable of same size but green in colour as continuous earthing wire complete all as specified and as directed. NOTE for item No 56,57 & 59 : Four runs (3P+1N) of copper conductor, One run of copper conductor as earth wire and one run of PVC casing and capping / PVC conduit shall be measured as one unit length.
All as per item Sl No 56 above, but , sub main wiring with two runs (1P+1N) of 6.0 Sqmm single core duly earthed with one run of single core cable of same size but green in colour as continuous earthing wire complete all as specified and as directed.
All as per item Sl No 56 above, but , sub main wiring with four runs (3P+1N) of 4.0 Sqmm single core duly earthed with one run of single core cable of same size but green in colour as continuous earthing wire complete all as specified and as directed.
All as per item Sl No 56 above, but , sub main wiring with two runs (1P+1N) of 1.5 Sqmm single core duly earthed with one run of single core cable of same size but green in colour as continuous earthing wire complete all as specified and as directed. NOTE for Item No( 58 & 60): Two runs (1P+1N) of copper conductor, One run of copper conductor as earth wire and one run of PVC casing and capping / PVC conduit shall be measured as one unit length.
S & F in replacement of DB VTPN sheet metal enclosure double door IP 43 protection, door earth suitable for incoming upto MCCB 100 Amps/ 200 Amps & outgoing MCB TP / SP. Triple pole and neutral 415 V 4 Way with 200 Amp rated standard bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated complete and making good to the distrubed surface /walls all as specified and directed.
S & F in replacement of Triple pole and neutral sheet steel powder coated Distribution board IP -43 protection with door earthing for MCBs fitted with 200 Amps rated bus bar , Neutral link ,Earth Bar and Din rail suitable for use on 415 V, 50 Hz supply double door TPN DB system 04 ways, and making good to the distrubed surface /walls complete all as specified and directed.
S & F in replacement of MCB DB, SPN, 12-way, double door, 240 Volts with 200 Amps rated bus bar, IP-43 protection, shrouded neutral bus bar, cement spill protector, concealed in wall and making good disturbed surfaces to match with surrounding surface complete all as specified and as directed.
Description same as per item Sl No 63 above, but , 8 way complete all as specified and as directed.
Description same as per item Sl No 63 above, but, 4 way complete all as specified and as directed.
S & F in replacement of MCCB, 4 pole, 125 Amps, 50Hz, 25KA rupturing capacity, 415 Volts adjustable type with thermal and magnetic release complete all as specified and as directed.
S & F in replacement of MCCB, 3 pole, 100 Amps, 50Hz, 25KA rupturing capacity, 415 Volts adjustable type with thermal and magnetic release complete all as specified and as directed.
S & F in replacement of MCB, TPN, "C" series, 415 volts, 63 Amps, 10 KA rupturing capacity complete all as specified and as directed.
S & F in replacement of MCB, TP, "C" series, 230 volts, 40-63 Amps, 10 KA rupturing capacity complete all as specified and as directed.
S & F in replacement of MCB, SPN, "C" series, 230 volts, 32 Amps, 10 KA rupturing capacity complete all as specified and as directed.
S & F in replacement of MCB, SP, "C" series, 240 volts, 6 to 32 Amps, 10 KA rupturing capacity complete all as specified and as directed.
Manufacturing, supplying and fixing at various sub stations for SINGLE LINE DAIGRAM of HT cabl netwoek / water pipe line having fully covered by suitable plain glass as approved by Engr -in-Charge. Letter, Symbols, MES Logo. Borders etc on A-1 size paper all as required colour schemme in all respects as per diretion of Engr-in-Charge.
Manufacturing, Supplying and fitting at various power house / pump house for reflective sign board of size 900mm x 1500mm x 150mm made out of 2mm thick aluminium sheet, face to be fully covered with high intensity acrylic sheet and 2 no's focused LED of 10 Watt each as approved by Engr-in-charge. Letter made out from stainless steel, symbols. MES Logo, Borders etc, required colour scheme on the boards and with high intensity grade A. The aluminium sheet to be riveted to MS Frame of angle iron of size 40 x 40 x 4mm complete in all respects as per direction of Engr-in-charge
Supplying, fixing and testing Tube light fittings aluminium housing, Diffuser slim Integrated design LED 21 watts 4 feet, IP-20 including all accessories and fixing arrangements for fixing the light fitting complete all as specified and directed. Make: Philips Cat Part No : BN021C LED22S or equivalent to CG/ Havells/ Luker
Supplying, fixing and testing Tube light fittings aluminium housing, Diffuser slim Integrated design LED 10 watts 2 feet, IP-20 including all accessories and fixing arrangements for fixing the light fitting complete all as specified and directed. Make: Philips Cat Part No : BN021C LED12S or equivalent to CG/ Havells/ Luker
S & F in replacement of Decorative, wall mounting, light fitting with 9 W LED lamp B22 base complete all as specified and as directed. Make-Havells model No LHFOAJE1TN1I060 or equivalent in Havells/ CG/ Luker
S & F and testing fully diffused recessed mounted 2' x 2' LED luminarie with with high transmitive diffuser for indoor spaces of cap 36 watt ncluding all accessories and fixing arrangements for fixing the light fitting to any heighted indoor palces complete all as specified and directed. Make :- Philips model No-RC360B LED36S or equivalent to Havells/ CG/ Luker
S & F Surface mounted general purpose square shaped luminaire with low height CRCA housing and high transmissivity diffuser of cap 40 watt of size 595 mm x595mm x 65 mm including all accessories and fixing arrangements for fixing the light fitting to any heighted indoor palces complete all as specified and directed. Make :- Luker model No- LKMSRS40 or equivalent to Havells/ CG/ Philips
Taking down old corroded GI bracket of 25 mm dia and supply and fixing new GI brackets of GI pipe light grade of size 25 mm dia including nuts, bolts and washers for building secufity light all as specified and directed
M&L for earthing complete with GI earth plate electrode of size 600mmx600mmx6mm thick buried directly in ground (earth pit not less than 2.25m deep below the normal ground level) with top edge of the earth plate not less than 1.5m below normal ground level connected to 4mm dia GI earth wire as earth lead connected by means of bolts, nuts, washers and check nuts made out of galvanised iron or steel all as shown on electrical plate No. 3 of SSR Part-I connected to common earth dolly including testing on completion complete all as specified and directed. NOTES: 1) The unit rate shall also include for earth work in any type of soil, PCC (1:3:6) type C1 chamber, pre-cast RCC (1:2:4) type B-1 using 20mm graded stone aggregate cover 50mm thick reinforced with TMT bars 8mm dia @ 100mm c/c both ways, funnel with watering pipe 20mm dia medium grade, GI protection pipe light grade 40mm dia and wire mesh complete in addition to item No. 1(a) to (e) of preamble (notes) under sub-heading earthing, specified on Sl. Page Nos. 422 & 423 of SSR Part-II. 2) Earthing lead and GI protection pipe beyond 7.5m will be measured and paid separately.
Repair to LED light /PTLs of any model/make/rating in position including testing of serviceability of connected accessories, and wiring upto respective switch/control unit including and replacing unserviceable items such as drivers , holder and making light functional. Note: (i) All the spares such as drivers, holder, LED tubes etc including replacing will be will measured and paid separately (ii) The representative of the contractor shall report to Engineer-in-charge/JE on daily basis to carry out repairs to light fitting and completion report to be submitted all as specified and as directed
S & F in replacement of PVC insulated copper conductor cable of following sizes, 1100 Volts grade, Heavy Duty, served with inner sheathing (flexible) industrial cable complete all as specified.
4.0 sqmm single core
2.5 sqmm single core
1.5 sqmm single core
Removing and refixing the following during Addn/ Altn/ modification of existing structure:-
Light fixture/ switch socket outlet of any type and any capacity.
Ceiling Fan/ Exhaust Fan of any sweep.
Split Air Conditioner of any capacity.
S & F in replacement of only electronic drivers for 10 to 24 watt LED post top luminaire / LED light fittings operated at input AC voltage 85 to 265 Volts, 50Hz, output DC voltage 42 to 65 Volts, 300MA, P.F > 0.95 incl necessary fixing arrangment as per site requirement complete all as specified and as directed. Make :- Philips/ CG/ Havells/ Bajaj
S & F in replacement of 9 Watts holder type (E22) LED lamp (E22) 230 Volts, 50Hz complete all as specified and as directed. Make :- Philips/ CG/ Havells/ Bajaj
S & F in replacement of 7 Watts retrofit holder type (E27) LED lamp 230 Volts, 50Hz complete all as specified and as directed. Make :- Philips/ CG/ Havells/ Bajaj
S & F in replacement of LED tube of cap 20 watt, 4' long suitable for flame proof light fitting installed at any position incl taking down of fitting and re-fixing of the same after replacing the tube all as specified and directed by Engr In Charge.
M&L for Repair to point wiring for light/fan/socket by cutting, removing and replacing the burnt and unserviceable wire with new FRLS cable and conduits with copper conductor 1.5/2.5 Sqmm size, jointing with same size wires, replacing the saddles, refixing the loose/hanging conduits/casing capping properly all as directed. Note:(i) Rate is inclusive for FRLS cable and other minor items (ii) The representative of the contractor shall report to Engineer-in-charge/JE on daily basis to carry out repairs and completion report to be submitted all as specified and as directed
M&L for taking down of unsv /damaged Casing & caping of size 25mm x12 mm from its existing location and s & f in replacement of the same alongwith connected accssories ,fixing with the wall, roof etc as specified and directed by Engr In Charge.
All as per item No 89 above, but , Conduit 25 mm dia.
S & F in replacement of modular white cover plate with farme suitable for 3 module, refixing with the existing /new switches all as specified and directed by Engr In Charge.
All as per item no 91 above, but , suitable for 4 module.
All as per item no 91 above, but , suitable for 6 module.
All as per item no 91 above, but, suitable for 8 module. Note for item No 91 to 94 :- The new modular switch/sockets required will be measured and paid separately under relevant item.
Sree Tirumala Enterprises (BID ID -3477926)
Manas Patra Steel Fabrication (BID ID -3477855)
LOOK UP ENTERPRISES (BID ID -3478037)
V KARTHICK (BID ID -3478061)
M/s Prem Enterprise (BID ID -3477958)
M/s Ramesh Lal (BID ID -3477981)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.29 MB
8204Tender.pdf
Tender Documents • 0.79 MB
BOQ_824094.xls
BOQ • 0.36 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .