Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.1 LAccepted-AOC NO 15 NEW STREET EACHANGADU KIRUMAMPAKKAM PUDUCHERRY 607 402 | CUDDALORE | TAMIL NADU | 607402 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹17.1 L+₹1,360 (0.08%)Rejected-Finance NO 58 SOUTH STREET BAHOUR PUDUCHERRY 607 402 | PONDICHERRY | PUDUCHERRY | 607402 | L2 | Rejected-Finance L2 |
Tender Value
Refer Docs
EMD Value
₹32,519
Closing Date
29 Feb 2024, 10:30 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
The Commissioner, BCP
Bahour Commune Panchayat, Bahour
Providing BT road facilities and construction of Cremation shed in Pannithittu Village of Embalam Constituency.
2024_DLA_15462_1
70/BCP/e_Tender/2023-24
Open Tender
Civil Works
Works
90 days
Pannithittu
Please refer Tender documents.
3 documents required · 3 mandatory
₹525
₹32,519
23 Mar 2024
23 Feb 2024
29 Feb 2024
23 Feb 2024
29 Feb 2024
23 Feb 2024
Amount
Code No:2.3.1A Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth upto 300mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000m including removal and disposal of top organic soil not exceeding 150mm in thickness - by manual means in area of light jungle.
Code No: 4.91B Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth three wheeled steel roller 8-10 tonnes in stages to proper grade and camber, applying and brooming requisite Crushable type such as moorum / gravel for screening and gravel for binding to fill up the interstices of coarse aggregate, watering and compacting to the required density - by manual means - Water bound macadam Gr-I with Gravel screening. (As per MoRTH specification, 4th Revision)
Code No:4.92C Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including eading in uniform thickness, hand packing, rolling with mooth 3 wheeld steel roller 8-10 tonnes in stages to proper grade and camber, applying and brooming requisite Crushable type such as moorum or gravel for screening and gravel for binding to fill up the interstices of coarse gregate, watering and compacting to the required density - by manual means - Water bound macadam Gr-II with moorum or gravel screening. (As per MoRTH specification, 4th Revision)
Code No: 6.1.MO Cleaning the existing W.B.M. road surface including removing of binding material and other foreign matter with wire brushes and small picks, sweeping with brooms or soft brushes and finally dusting with old gunny bags and/or compressed air to receive bituminous treatment. As per clause no 502.4.2 and 503.3.1 of MOST specification.
Code No:6.5F.1.MO Providing and applying tack coat on the prepared surface, heating bitumen in boiler and spraying the bitumen with sprayset fitted on bitumen boiler - on granular base such as WBM and WMM surfaces not bitumen primed. Rate of application 10kg/10sqm
Code No: 6.11B.MO Providing and laying open graded premix carpet 20mm thick on prepared surface in a single course as wearing course composed of specified size of stone aggregates premix with a bituminous binder in mini hot mix plant 6 to 10 tonne laying manually and rolling with power roller 8 to 10 tonne but excluding cost of primer/tack coat. As per clause no 509 of MOST specification.
Code No:6.17.MO Providing and applying premixed seal coat type `B' comprising of thin application of fine aggregate premix with bitumen binder in mini hot mix plant, carriage manually of mixed material and laying and rolling with power roller 8 to 10 tonne. As per clause no 513 of MOST specification.
Code No:2.27C.1 Supplying and filling with gravel (excluding rock) in layers not exceeding 20cm in depth , breaking clods , watering , rolling each layer with 1/2 tonne roller , or wooden or steel rammers and rolling every 3rd and top-most layer with power roller of minimum 8 tonnes capacity including all leads and lift (Payment will be made based on level measurement)
Code No:2.10.1.1 Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m - all kinds of soil - pipes, cables etc , not exceeding 80mm dia
Code No:31.161.1D Providing, laying and jointing UPVC pipes(Finolex / jain / Supreme / Truebore /Nandi) (0.6 pa) conforming to IS specification 4985 and ISI marked including transportation to the site ,lowering to the trenches, laying to proper grade and alignment, testing of joints with required testing equipment, uding cost of solvent cement, UPVC specials such as bends, tees, threaded pieces, couplers, reducer, endcaps etc., complete all as per IS and CPWD specification. - 75mm dia.
Code No:31.173.1B Providing and fixing in position UPVC moulded saddle set (Finolex / jain)(0.6 Mpa) conforming to IS 7834 part II and ISI marked, including labour charges for jointing, jointing materials etc,complete 75 x 20mm dia
Code No:31.160.1B Providing, laying and jointing UPVC pipes (Finolex / jain / Supreme / Truebore /Nandi (1Mpa) conforming to IS specification 4985 and ISI markedincluding transportation to the site , lowering to the trenches, laying to proper grade and alignment, testing of joints with required testing equipment, including cost of solvent cement,UPVC specials such as bends,tees, threaded pieces, couplers,reducer,endcaps etc.,complete all as per IS and CPWD specification. - 25mm dia.
CodeNo:18.15.2 Providing and fixing brass bib cock of approved quality - 20 mm nominal bore
CodeNo:18.17.1 Providing and fixing gun metal gate valve with C.I.wheel of approved quality (Screwed end) - 25mm nominal bore
Code No: 2.8.1 Earthwork in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5m, including getting out the excavated soil and disposal of surplus excavated soil as directed , within a lead of 50m - all kinds of soil
Code No: 2.25 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50m and lift upto 1.5m
Code No: 30.7 Supply of Quarry rubbish including stacking to department gauge for premeasurement and ng required thickness
Code No: 2.27A .1 Supplying and filling with gravel (excluding rock) in trenches , plinth, sides of foundations etc . In layers not exceeding 20 cm in depth consolidating each deposited layers by ramming and watering etc .complete including all lead and lift
Code No: 4.1.10 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work upto plith level - 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40mm nominal size)
Code No: 5.1.2 Providing and laying in position specified grade of reinforced cement concrete ,excluding the cost of centering , shuttering , finsishing and reinforcement - All work upto plinth level 1:1.5:3 (1cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
Code No:5.2.2 Reinforced cement concrete work in walls (any thickness) , including attached pilasters, buttresses , plinth and sting courses , fillets , columns , pillars , piers , abutments , posts and struts etc. upto floor five level excluding cost of centering , shuttering , finishing and reinforcement - 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size)
Code No: 5.3 Reinforced cement concrete work in beams, suspended floors , roofs having slope up to 15degree landings , balconies , shelves , chajjas , lintels , bands , plain window sills , staircases and spiral stair cases upto floor five level excluing the cost of centering ,shuttering, finishing and reinforcement , with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size)
Code No:5.9.1 Centering and shuttering including strutting , propping etc and removal of form for - foundations, footings, bases of columns etc for mass concrete
Code No: 5.9.3 Centering and shuttering including strutting , propping etc and removal of form for - Suspended floors , roofs, landings , balconies and access platform
Code No: 5.9.5 Centering and shuttering including strutting , propping etc and removal of form for - Lintels , beams , plinth beams , girders , bressumers and catilevers
Code No:5.9.6 Centering and shuttering including strutting , propping etc and removal of form for - Columns , Pillars , Piers , Abutments , Posts and Struts
Code No:5.11.1 Extra for additional height in centering , shuttering where ever required width adequate bracing , propping etc. including cost of de - shuttering and decentering at all levels , over a height of 3.5m, for every additional height of 1metre or part thereof (plan area to be measured) - Suspended floors, roofs, landing , beams and balconies (Plan area to be measured)
Code No:5.22.6 Steel reinforcement for R.C.C.work including straightening , cutting , bending , placing in position and binding all complete upto plinth level - Thermo -Mechanically treated bars (TISCON / VIZAG / IISCO / SAIL / JSW) Fe - 415 or more
Code No:5.22A.6 Steel reinforcement for R.C.C.work including straightening , cutting , bending , placing in position and binding all complete above plinth level - Thermo - Mechanically Treated bars (TISCON / VIZAG / IISCO / SAIL / JSW) Fe - 415 or more
CodeNo:6.1.2 Brick work with common burnt clay F.P.S. (non modular ) bricks of class designation 7.5 in foundation and plinth in - cement mortar 1:6 (1 cement : 6 coarse sand)
Code No:6.8 Brick work 7 cm thick common burnt clay F.P.S. (non modular) brick of class designation 7.5 in cement mortar 1:3 (1cement : 3 coarse sand ) in superstructure above plinth level and upto floor five level
Code No:6.35.1 Brick work with modular calcium silicate bricks machine moulded conforming to IS -4139 , class designation 10 average compressive strength in super structure above plinth level upto floor V level in -cement moratr 1:4 ( 1 cement : 4 coarse sand)
Code No:13.1.1 12mm cement plaster of mix -1:4 ( 1 cement : 4 fine sand)
Code No:13.2.1 15mm cement plaster on the rough side of single or half brick wall of mix - 1:4 (1cement : 4 fine sand)
Code No:13.7.1 12mm cement plaster finished with a floating coat of neat cement of mix - 1:3 (1 cement :3 fine sand)
Code No:13.16.1 6mm cement plaster of mix 1:3 (1 cement : 3 fine sand)
Code No:13.46.1 Finishing walls with acrylic smooth exterior paint of required shade - New work (two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg / 10 sqm
Code No: 0322 (Addendum) Hire charge for back Hoe loader(JCB)
V Ramadoss
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_15797.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .