| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹86.4 CrAccepted-AOC | ₹86.4 Cr Quoted ₹86.5 Cr | L1 | Accepted-AOC LOWEST BIDDER |
| 2 | L2₹104.7 CrRejected-Finance | ₹104.7 Cr | L2 | Rejected-Finance NOT LOWEST |
| 3 | Rejected-Technical L 87 STREET NO 7C MAHIPALPUR EXTENSION NEW DELHI 110037 | NEW DELHI | NEW DELHI | DELHI | 110037 | - | - | Rejected-Technical not recommended for opening since the firm is not meeting the PQC Criteria in respect of similar work experience of Bldg work with RCC Framed structure |
| 4 | Rejected-Technical K 99 LGF KALKAJI NEW DELHI 110 019 | NEW DELHI | SOUTH EAST DELHI | DELHI | 110019 | - | - | Rejected-Technical NOT RECOMMENDED FOR OPENING SINCE THE FIRM IF NOT MEETING THE PQC CRITERIA IN RESPECT OF SIMILAR WORK EXPERIENCE OFRIGID PAVEMENT WORK AND TURNOVER |
Tender Value
₹85.6 Cr
EMD Value
₹15 L
Closing Date
25 Feb 2022, 6:00 pmClosed
CHIEF ENGINEER
HQ CE(AF) WAC PALAM DELHI CANTT-10
PROVISION OF WORK SERVICES FOR PROJECT GHAGGHAR AT AF STATION NAL
2021_MES_496272_1
CEWAC/NAL/T-17/2021-22
Open Tender
Civil Works
1277 days
GE (AF) NAL
AS PER NIT AND TENDER DOCUMENTS
8 documents required · 8 mandatory
₹3,000
GE (AF) NAL
₹15 L
Yes
HQ CE(AF) WAC PALAM
31 Mar 2022
21 Dec 2021
4 Mar 2022
21 Dec 2021
25 Feb 2022
11 Feb 2022
21 Dec 2021 - 17 Jan 2022
25 Jan 2022
Amount
SCHEDULE `A' PART - I(A) is not prepriced by MES and prepriced rates indicates 0.0 under column 5 signified this fact only.
Design and Construction of Adm Building (D/S) including Porch as specified with permanent specifications as per tender provisions and area as shown in line plan complete.
Design and Construction of Block of office and tool room (S/S) as specified with permanent specifications as per tender provisions and area as shown in line plan complete
Design and Construction of RCC framed structure garages for SAMC -I & SAMC - II (Size 90m x 30m x 8m high) with electromechanical rolling shutters on both side of each and every bay (18 Nos Bays) of each garage including pavement quantity concrete(PQC) flooring complete as specified with permanent specifications as per tender provisions and area as shown in line plancomplete Note: (i)Hardstanding shown on line plan all around building shall be measured and paid separately.(ii) The layout of columns shall be as shown on line plan. The cross section of colums may vary as per approved design but clear spacing between colums and clear height of garages shall be strictly as per line plan.(iii) Contractor has to quote for 01(one garage) and multiply by 2 to arrive at total quoted amount of BOQ item No 1.03
Design and Construction of RCC framed structure garages for SAMC -I & SAMC - II Garages (Size 60m x 30m x 8m high) with electromechanical rolling shutters on both side of each and every bay (12 Nos Bays) of each garage including pavement quantity concrete flooring with permanent specifications complete as area shown in line plan. Note: (i) Hardstanding shown on line plan all around building shall be measured and paid separately.(ii) The layout of columns shall be as shown on line plan. The cross section of colums may vary as per approved design but clear spacing between colums and clear height of garages shall be strictly as per line plan.(iii) Contractor has to quote for 01(one garage) and multiply by 2 to arrive at total quoted amount of BOQ item No 1.04
Design and Construction of RCC framed structure Block of Garages (S/S) (Size 75m x 20m x 8m high) with electromechenical rulling shutters one side, including pavement quantity concrete flooring with permanent specifications complete and area as shown in line plan complete. Note: (i) Hardstanding shown on line plan all around building shall be measured and paid separately.(ii) The layout of columns shall be as shown on line plan. The cross section of colums may vary as per approved design but clear spacing between colums and clear height of garages shall be strictly as per line plan.
Design and Construction of Block of POL Store (S/S) building with permanent specifications as area shown in line plan complete.
Design and Construction of Block of Sub Station (S/S) building with permanent specifications as area shown in line plan complete.
Design and Construction of Guard Rest Room (S/S) building with permanent specifications as area shown in line plan complete.
Design and Construction of Block of Garages (S/S) car and two wheelers complete as area shown in line plan with permanent specifications.
RCC Septic tank conventional type designed to carry sewage and sullage water. excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls , Base Slab , Baffle walls and Roof Slab including beams etc with Vent shaft manhole openings with cover connection etc, complete with effective depth of 1.5 meter and overall depth of 3 meter for 150 users.
RCC septic tank design to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 design mix in walls, base slab, baffer walls and roof slab incl beams etc with vent saft manhole opening with cover, connection ect, complete with effective depth of 1.5 mtr and overall depth of 3 mtr for 25 users.
Soakage wells excavation, in any type of soil, foundation In PCC 1:3:6 walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 1.8 M dia X 3.0 M effective depth complete all as shown on drawings.
Soakage wells excavation, in any type of soil, foundation in PCC 1:3 6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab In M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 3 M dia X 6.0 M effective depth complete all as shown on drawings.
Construction of RCC static water tank as per permanent specification 25000 Gln complete all as specified and shown on drawing.
Design and Construction of PQC rigid pavement Roads and Hardstanding including necessary excavation in any type of soil, considering layers of DLC, GSB, Polythene film, sand layer, including using non circular polyester triangular fiber and joints like dummy, Expansion and Construction joints shall be provided as per MORTH and IRC specifications including removal of surplus soil to outside of MOD land (dumping yard for disposal of surplus soil shall be own arrangement of Contractor and nothing extra shall be paid on the account) complete all as specified and directed. Note: Complete item wise BOQ considering all items along with quantities should be submitted along with technical bids as per tentative schedule made part of tender.
Construction of sentry post as per permanent specifications complete all as shown on drawings.
SCHEDULE `A' PART - I(B) is not prepriced by MES and prepriced rates indicates 0.0 under column 5 signified this fact only.(Contractor should submit the Complete item wise BOQ considering all items along with quantities should be submitted along with technical bids as per tentative schedules made part of tender.
Design, supplying & fixing Lighting Protection of buildings here in before at srl No (1.03, 1.04, 1.06 & 1.07) complete all as specified and directed. Note: Complete item wise BOQ considering all items along with quantities should be submitted along with technical bids.
NOTE: Schedule ‘A’ Part II to XII are Prepriced by MES.
Lump sum price worked out by the Contractor for “EXCAVATION AND EARTH WORKS"” as listed in Schedule ‘A’ Part II
Lump sum price worked out by the Contractor for “INTERNAL ELECRTIFICATIONS” as listed in Schedule ‘A’ Part III
Lump sum price worked out by the Contractor for “INTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Part IV
Lump sum price worked out by the Contractor for "SEWAGE DISPOSAL” as listed in Schedule ‘A’ Part V
Lump sum price worked out by the Contractor for "AREA DRAINAGE ” as listed in Schedule ‘A’ Part VI
Lump sum price worked out by the Contractor for “SUMMER APPLIANCES ” as listed in Schedule ‘A’ Part VII
Lump sum price worked out by the Contractor for “CHAINLINK FENCING AND GATES ” as listed in Schedule ‘A’ Part VIII
Lump sum price worked out by the Contractor for “EXTERNAL WATER SUPPLY ” as listed in Schedule ‘A’ Part IX
Lump sum price worked out by the Contractor for “EXTERNAL ELECTRIC SUPPLY & STREET LIGHTS ” as listed in Schedule ‘A’ Part X
Lump sum price worked out by the Contractor for “FIRE POINTS & PCC FIRE BREAK PLINTH WORKS” as listed in Schedule ‘A’ Part XI
Lump sum price worked out by the Contractor for “DEMOLITION AND DISMANTLING” as listed in Schedule ‘A’ Part XII
SCHEDULE `A' PART - XIV MISC ITEMS is not prepriced by MES and prepriced rates indicates 0.0 under column 5 signified this fact only.
INTERNAL ELECTRIFICATIONS
M&L flame proof, zone I & lI. Gas Group II A/ II B, weather proof point wiring for one light or fan point controlled by one switch using approved colour coding as per IS with zero hologen flame retardent (HFFR) smoke free non toxic non corrosive PVC insulated unsheated flexible copper conductor cable 1.5 Sqmm (nominal area) single core 1100 volts grade in and including (ERW) stove enamelled condiuit heavy duty ISI marked duly welded, flame proof weather proof junction box, tee, bends, inspection bends etc all as required including PVC insulated unsheated flexible copper conductor cable 1.5 Sqmm (nominal area) single core 1100 volts grade as earth continuity conductor complete all as specified and directed.
M&L flame proof, zone I & II, Gas Group II N II B, weather proof point wiring for one socket point controlled by one switch using approved colour coding as per IS with zero hologen flame retardent (HFFR) smoke free non toxic non corrosive PVC insulated unsheated flexible copper conductor cable 4.0 Sqmm (nominal area)single core 1100 volts grade in and including (ERW) stove enamelled condiuit heavy duty ISI marked duly welded, flame proof weather proof junction box, tee, bends, inspection bends etc all as required including PVC insulated unsheated flexible copper conductor cable 4.0 Sqmm (nominal area) single core 1100 volts grade as earth continuity conductor complete all as specified and directed.
M&L for flame proof, zone I & II, Gas Group II N II B, weather proof submain wiring with two runs using approved colour coding as per IS, zero hologen flame retardent (HFFR) smoke free non toxic non corrosive PVC insulated unsheated flexible copper conductor cable 4.0 Sqmm (nominal area) single core 1100 volts and one run earth wire of 4.0 Sqmm in and including ERW stove enamelled black rigid conduit of required size but not less than 25mm dia, flame proof conduit accessories such as tee, bend, elbow, junction box all as specified and directed
Supply and fix flame proof Zone I & II gas group II A /II B weather proof DB TPN 415 volt 4 Way with bus bar in cast aluminium LM -6 enclosure operated externally spring type knob compltete with suitable incoming and out going cable entries with cable glands suitable for hazordous area and confirming to IS -2147/62 neoprene gasket gegree of protection IP 65 suitable for MCCB FP 100 Amps -01 No. MCB SP 40 Amp - 6 Nos , Blanking plates -06 Nos complete all as specified and directed.
Supply and fix flame proof Zone I & II gas group II A /II B weather proof DB SPN 415 volt 8 Way with bus bar in cast aluminium LM -6 enclosure operated externally spring type knob copmlete with suitable incoming and out going cable entries with cable glands suitable for hazordous area and confirming to IS -2147/62 neoprene gasket gegree of protection IP 65 suitable for MCB SPN 32 Amps -01 No, MCB SP 6-20 Amp - 6 Nos complete all as specified and directed.
Supply and fix flame proof Zone I & II gas group II A /II B weather proof asymmetrical beam integral LED light fittings 120 W grey powder coated die cast aluminium lamp housing built in control gear, faceted anodised aluminium reflector heat resistant toughened clear glass cover, necessary clamps, nuts, and bolts complete connecting electrically using flexible flame proof end connectors complete all as specified and directed.
Supply and fix flame proof Zone I & II gas group II A /II B weather proof exhaust fan 450 mm sweep cast iron body, grey finished complete all as specified and directed.
Supply and fixing flame proof, zone l&ll, gas group II A/ll B weather proof switch socket and plug combine in LM6 enclosure 40Amps 4 pole and earth complete with appropriate MCCB of 40Amp reading complete all as specified and directed.
S&F LED bulb 9 Watt, 230 volts retrofit type complete all as specified and directed.
S&F LED light fittings 1 x 40Watt 220 V, AC box type with driver holder connecting up with three core flexible copper conductor cable 0.5 sqmm from ceiling rose complete all as specified and directed by Engr in charge.
S& F Security light fittings LED 15 watt, input 110 to 230V as per IP 65 luminaries comprising of rectangular shape, high pressure die cast aluminium housing, with weather proof gaskets for lamp and driver compartment with Gl Pipe 25mm dia light grade bend to shape including necessary fixing arrangement complete all as specified and directed.
S&F ceilling fan five star 900mm complete with fan regulator 1230Volts (single phase ) and provisioning of flexible copper cord three core PVCC inhsulated & overall sheathed of size 0.50 sqmm of required lenght from ceiling rose or connector to ceiling fan complete all as specifiedd and as directed.
S&F factory made sheet metal enclosures for distribution board double door type made out of M.S sheet, concealed in wall, VTPN with 300 Amps rated bus bar, 04 way 415 volts, with MCCB of 200 Amp MCCB horizontal complete all as specifiedd and as directed.
M&L chemical earthing complete with copper earth plate electrode 600 mm x 600 mm x 5 mm thick buried directly in ground vertically in a pit of depth not less than 3.65 metre below normal ground level with top edge of the earth plate at a depth not less than 2.90 metre below normal ground level, earth plate connected to copper strip 32 x 6 mm as earthing lead by means of running gas welding / brazing for a length of 45cm, copper strip protected by galvanized steel pipe 50 mm bore medium grade upto ground level and there after by 50 mm dia HDPE pipe upto test point (maximum upto 7.5metre from earth plate), earth plate surrounded by charcoal or coke and common salt upto 90 cm in alternate layers of 15cm each, there over a layer of 60cm tibba sand duly compacted, thereafter 30 layer of magnesium sulphate powder (compacted thickness) and finally filing the top of pit upto ground level with tibba sand, to achieve earth resistance value less than 2 Ohm including provision of 20mm bore galvanised steel pipe 20mm bore light grade with funnel & wire mesh for watering, earth pit chamber built in cement concrete 1:3:6 type C-1 using 20mm graded stone aggregate covered with 50mm thick pre-cast cover slab of RCC 1:2:4 type B- 1
S&F pressed steel terminal box of size 100 x 100 x100 mm with 3 mm thick plastic laminated sheet complete all as specifiedd and as directed.
FIRE POINT
Construction of fire symbol Board complete all as specified and directed
Construction of Fire fighting steel board complete all as specified and directed
ROAD/PATH/HARSTANDING/CULVERT
Demolition of Bituminous premix asphaltic dence concrete of any thickness in existing road and removed the demolished material out of MOD land without any extra cost to the department and contractor has in make arragement for disposal of demolished material ourtside of MoD land completed all as specified and directed.
Demolition of Soiling and WBM of any specification and thickness in existing road complete all as directed
Material, labour and applying road marking paint white/yellow (2.0mm thick) centre line, stop line, dashes, arrows, brackets & similar work on road surfaces as per IRC pattern. retro-reflective type specified shade/ colour using hot thermoplastic material by automatic thermoplastic paint applicator machine fitled with profile shoe glass beads dispenser, propane tank heater and profile shoe heater, driven by experienced operator on road surface including cleaning the road surface and remove all dirt, seals, oil, grease and foreign material etc. complete all as per manufacturer’s instructions and as per direction complete all as specified and directed.
Chainlink Fencing
S&F for galvanised, concertina wire 1.00 mtr dia layed in two line over concrete surface between 02 lines of chain link fencing complete all as specified.
M & L for steel gate 7.5m wide and 2.75m high form road level alongwith wicket gate for security fencing including PCC, MS work, earth work. RCC pillars, painting etc complete all as specified and shown on drawing. (Drg No: CEAF/STD-151/2002 Dt 02 Nov 2002)
Summer Appliances
Supply and fix desert cooler electric driven (single phase), having nominal air flow capacity minimum 4000 CUM per hour (or nearest size) (GI sheet body) on equal iron frame structure complete with GI tank capacity 60 ltr approx, including MS angle iron stand made of 50x50x6 mm fixed on wall near window include two coat of synthetic enamel black paint over a coat of red oxide on angle iron frame complete. Note: GI pipe line for water in let connection shall be measured & paid separately under relevant item of schedule.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 260 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA including time delay relay complete all as specified and directed.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 260 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4 KVA including time delay relay complete all as specified and directed.
EOT Crane
Supply Installation in position testing and commissioning of flameproof EOT crane double girder type class - II of 10 Ton capacity with all motion ie, long travel 36.0 mtr approx. cross travel 8.75 mtr approx. and crane should be provided with one no. platform spanwise of width 750 mm with suitable railing and fastoon type down shop lead of flexible copper conductor complete having the following components and specification.(For IGLOOs -3 Nos x 2 = 6) (a) Capacity 10 Ton (b) Design standard as per IS-807, 3177, 800,2148 (c) Class/ Duty - II indoor type, Flame proof gas group zone Ila & llb (d) Item - Double Girder EQT crane (e) Construction box type/ ISMB (f) Hoist speed - 3.0 mtr per min (g) Creep hoist speed - 0.3 mtr per min (h) Cross travel speed - 08 mtr per min U) Long travel speed - 12 mtr per min (k) Operation- pendant control (Flame proof) (I) Span 8.75 mtr (m) Lift - upto 4.5 mtr (n) Long travel length - 36 mtr (o) End clearance - 250 mm (p) Head Room - 1.8 mtr. Note:- (i) General arrangement drawing to be got approved by HQ CEWAC before placing order. (ii) Square bar rail of size 40x40 mm or next higher size as per manufacturer recommendation will be provided by contractor. (iii) I - Section of suitable size alongwith MS base plate with nuts & bolts to be provided with bldg work.
Supply Installation in position , testing and commissioning of flameproof EOT crane double girder type class - II of 10 Ton capacity with all motion ie. long travel 18 mtr approx. cross travel 14.75 mtr approx. and crane should be provided with one no. platform spanwise of width 750 mm with suitable railing and fastoon type down shop lead of flexible copper conductor complete having the following components and specification. (For IGLOOs -3 Nos x 1 = 3)(a) Capacity 10 Ton (b) Design standard as per IS-807, 3177, 800,2148 (c) Class/ Duty - II indoor type, Flame proof gas group zone Ila & lIb (d) Item - Double Girder EOT crane (e) Construction box type/ ISMS (f) Hoist speed - 3.0 mtr per min (g) Creep hoist speed - 0.3 mtr per min (h) Cross travel speed - 08 mtr per min (j) Long travel speed - 12 mtr per min (k) Operation- pendant control (Flame proof) (I) Span 14.75 mtr (m) Lift - upto 4.5 mtr (n) Long travel length - 18 mtr (o) End clearance - 250 mm (p) Head Room - 1.8 mtr Note:- (i) General arrangement drawing to be got approved by HQ CEWAC before placing order (ii) Square bar rail of size 40x40 mm or next higher size as per manufacturer recommendations will be provided by contractor. (iii) I - Section of suitable size alongwith MS base plate with nuts & bolts to be provided with bldg work.
M&L earthing complete with copper earth plate electrode 300 mm x 300 mm x 3 mm thick, burried directly in ground in vertical position, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below ground level. The earth plate to be connected with copper earthing strip of size 25 mmx 3mm thick by means of brazing between copper strip and earth plate min 45 cm in vertical length and copper strip also to be joined by brazing only. The copper earthing strip to be protected by galvanised iron pipe 40 mm bore (medium grade) up to ground level and thereafter with 40mm dia HDPE pipe up to test point. Earthing shall include provision of funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) up to 90 cm all around earth plate further filled with 60 cm thick Tibba sand and 2nd layer with 30 cm of Magnesium sulphate powder (compact thickness), 3rd layer with tibba sand up to ground level. Earthing shall also +B87 include concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C both ways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth
Supply and fixing flame proof, zone 1&11, gas group II A/II B weather proof switch socket and plug combine in LM6 enclosure 40Amps 4 pole and earth complete with appropriate MCCB of 40Amp reading complete all as specified and directed.
External Water supply
Cutting the existing pipe GI of size up to 80 mm dia. In position and providing I insert TEE Attch suitable for 80mm dia GI pipe complete all as specified and directed.
All as per Sri item No 11.01, above but for upto 40mm GI Pipe complete all as specified and directed.
Material and labour for construction of brick masonry valve pit of size 90 cm x 90 cm x 90 cm (internal dimensions), using old size sub class 'B' brick, built in CM 1:6 and 10 mm thick cement plaster 1:4 both internally and externally with 75 mm thick PCC 1:3:6 type C-2 in foundation, PCC 1:2:4 type 8-2 in benching complete with and including 2 mm thick mild steel sheet cover (mounted on angle iron frame of size 50 mm x 50 mm x 6 mm thick, embedded in PCC 1:2:4 type 8-1 coping), fitted with proper locking arrangement, hinges and handle of suitable size and painting with two coats of black bituminous paint over a coat of red oxide zinc chrome primer on all steel surfaces, including necessary earth work ( in soft/loose soil), returning filling and removal of surplus soil to a distance n.exc 50 m complete all as specified and directed
External Electric Supply
Supply, installing, testing and commissioning of Outdoor type step down transformer, 11KV/433 volts AC three phase 50 Hz, 400 KVA capacity, core type, double copper wound, oil immersed, naturally cooled, oil natural- Air natural (ONAN), with external cooling tubes/fins, delta connected on primary side (HV) and star connected on secondary side (LV) in accordance with vector group DYN-11 with neutral brought out on secondary side (LV side) and having tapings at ±2.5 % & ± 5% on HV side to be changed by means of hand operated off load tap changer gear. Losses at 50% load not more than 829 W & at 100% load not more than 2164 W .The maximum temperature rise should not exceed 45 degree celcius in oil and 55 degree celcius in HV/LV winding when measured by resistance method after continuous full load run on an ambient temp of 40 degree celcius. The transformer shall be IS-1180 ,4 star and shall comprise of following (a) Three nos porcelain bushing suitable for 11 KV on HV side, complete with brass/copper rods, nuts and washer and cable box (b) One cable box on LT side (secondary side) consisting of four nos porcelain bushing with copper rods, complete with nuts and washers, with cable glands suitable for reception/taking out out of LT 1100 volts grade XLPE, armoured cables including jointing materials complete. (c) Oil conservator with filter type drain valve and oil level gauge (d) De-hydrating breather with first fill of dehydrating agent (silica gel)
(e) Explosive vent, themometer pocket on tank cover, oil levbel gauge, oil drain filtervalve, lifting lugs/jacks, oil filling hole with cap/plug with connection plate complete, Air release valve plug and four nos plain solid cast steel detachable rollers (f) One no dial type thermometer, vapour pressure type, having range 0-120 degree celcius with metal guard having maximum perimeter temperature reading indicator with re-setting device.
(g) Two earthing terminals on tank cover to facilitate fixing of 32x6 mm galvanised iron earth strip for earthing of body. (h) Rating plate and terminal marking plate (j) Extra bushing for neutral, in the LT cable box for providing independent set of earthing for neutral including all other standard accessories. Note: (i) First filling of new transformer oil conf to IS-335 marked filtered and tested upto 40KV dielectric strength at 2.5 mm air gap between electrodes. (ii) Rate also inclusive for providing tools & plants required for testing and commissioning of transformer by SEI. (iii) Rate is included for necessary foundation as per recommendation of manufacturer
Supply, installaing, testing and commissioning of Outdoor type step down transformer,11KV/433 volts AC three phase 50 Hz, 250 KVA capacity, core type, double copper wound, oil immersed, naturally cooled, oil natural- Air natural (ONAN), with external cooling tubes/fins, delta connected on primary side (HV) and star connected on secondary side (LV) in*accordance with vector group DYN-11 with neutral brought out on secondary side (LV side) and having'tapings at ± 2.5% & ± 5% on*HV side to be changed by means of hand operated off load tap changer gear. Losses at 50% load not more than 811 W & at 100% load not more than 2293 W .The maximum temperature rise should not exceed 45 degree celcius in oil and 55 degree celcius in HV/LV winding when measured by resistance method after continuous full load run on an ambient temp of 40 degree celcius. The transformer shall be IS-1180 ,4 star and shall comprise of following: (a) Three nos porcelain bushing suitable for 11 KV on HV side, complete with brass/copper rods, nuts and washer and cable box (b) One cable box on LT side (secondary side) consisting of four nos porcelain bushing with copper rods, complete with nuts and washers, with cable glands suitable for reception/taking out out of LT 1100 volts grade XLPE, armoured cables including jointing materials complete. (c) Oil conservator with filter type drain valve and oil level gauge (d) De-hydrating breather with first fill of dehydrating agent (silica gel)
(e) Explosive vent, themometer pocket on tank cover, oil levbel gauge, oil drain filter valve, lifting lugs/jacks, oil filling hole with cap/plug with connection plate complete, Air release valve plug and four nos plain solid cast steel detachable rollers (f) One no dial type thermometer, vapour pressure type, having range 0-120 degree celcius with metal guard having maximum perimeter temperature reading indicator with re-setting device.
(g) Two earthing terminals on tank cover to facilitate fixing of 32x6 mm galvanised iron earth strip for earthing of body. (h) Rating plate and terminal marking plate (j) Extra bushing for neutral, in the LT cable box for providing independent set of earthing for neutral including all other standard accessories. Note: (i) First filling of new transformer oil conf to IS-335 marked (Make- Savita/Power link) filtered and tested upto 40KV dielectric strength at 2.5 mm air gap between electrodes. (ii) rate also inclusive for providing tools & plants required for testing and commissioning of transformer by SEI. (iii) Rate is included for necessary foundation as per recommendation of manufacturer.
Supply, installing, testing and commissioning of Indoor type step down transformer, 11KV/433 volts AC three phase 50 Hz, 160 KVA capacity, core type, double copper wound, oiUmmersed, naturally cooled, oil natural- Air natural;(ONAN), with external cooling tubes/fins, delta connected on primary side (HV) and star connected on secondary side (LV) in accordance with vector group DYN-11 with neutral brought out on - secondary side (LV side) and having tapings at ± 2.5% & ± 5% on HV side to be changed by means of hand operated off load tap changer gear. The losses at 50% load not more than 462 W & at 100% load not more than 1408 W . The maximum temperature rise should not exceed 45 degree celcius in oil and 55 degree celcius in HV/LV winding when measured by resistance method after continuous full load run on an ambient temp of 40 degree celcius. The transformer shall be IS-1180 , 4 star and shall comprise of following: (a) Three nos porcelain bushing suitable for 11 KV on HV side, complete with brass/copper rods, nuts and washer and cable box
(b) One cable box on LT side (secondary side) consisting of four nos porcelain bushing with copper rods, complete with nuts and washers, with cable glands suitable for reception/taking out out of LT 1100 volts grade XLPE, armoured cables including jointing materials complete. (c) Oil conservator with filter type drain valve and oil level gauge (d) De-hydrating breather with first fill of dehydrating agent (silica gel) (e) Explosive vent, themometer pocket on tank cover, oil levbel gauge, oil drain filter valve, lifting lugs/jacks, oil filling hole with cap/plug with connection plate complete, Air release valve plug and four nos plain solid cast steel detachable rollers (f) One no dial type thermometer, vapour pressure type, having range 0-120 degree celcius with metal guard having maximum perimeter temperature reading indicator with re-setting device. (g) Two earthing terminals on tank cover to facilitate fixing of 32x6 mm galvanised iron earth strip for earthing of body. (h) Rating plate and terminal marking plate (j) Extra bushing for neutral, in the LT cable box for providing independent set of earthing for neutral including all other standard accessories.
Note: (i) First filling of new transformer oil conf to IS-335 marked filtered and tested upto 40KV dielectric strength at 2.5 mm air gap between electrodes.(ii) rate also inclusive for providing tools & plants required for testing and commissioning of transformer by SEI. (iii) Rate is included for necessary foundation as per recommendation of manufacturer
Taking down carefully existing transformer of capacity 100KVA after disconnecting LT and HT connection and shifting to MES store complete all as specified and directed.
Supply,installation,testing & commissioning of 11 KV Indoor type extensible RMU floor mounted 1 LBS with internal copper bus bars, consisting of 630 Amp fixed manual Load Break Switch . All live parts, bus, bars, LBSs connections of RMU shall be enclosed in one tank to avoid multiple interconnections & sealed for life robotically welded non magnetic and non ferrite grade stainless steel tank Grade 304 of minimum 2.5 mm thick having IP67 degree of protection filled with SF6 gas as insulation with leakage rate less than 0.1% per year tested as per IEC 62271-200. Location: Sub Stn WSA (I) The unit shall have front cable entry for ease of installation and shall have site replaceable bushings for ease of troubleshooting during breakdown. RMU should be complete with all accessories such as Terminal boots, VPIS, cable supports, all front cable terminations, mechanical indications for;.Load break switch ON/OFF,
Manometer as perwith IEC standards 62271-200, 60056, 60129, 60265, 60298, 60420, 60529 and 60694. Altitude of installation up to 1000m as per IEC 60120. Extensible Bushings,if applicable shall be bolted type top ” mounted outside the tank for connection of external bus bar .Also, the outer enclosure shall cover the full length of the switchgear.to ensure IP3X+IP54 protection for cable boxes . (II) The unit shall be internal arc proof 21 kA for 1 sec. for tank+Cable Box ,and tested and totally safe for human beings. (III) Bidder shall provide type test report to prove compliance to the ‘Internal fault IAC-AFLR as per IEC 62271- 200.lnternal arc proof & testing shall be done with enclosure door in open condition, with switching devices in operation mode. The unit shall include the following with all necessary standard fitting required at site. (IV) 630A Load Break Switch module for making of fault current alongwith Earth Switch of full making capacity Short time withstand current - 21 KA/ 3 sec Making Capacity - 52.5kAp Auxiliary contacts -1 NO + 1NC
Power frequency withstand voltage - 38kV Impulse withstand voltage - 95kV Nominal operating gas pressure -1.4 Bar abs. Front cover mechanism - IP2X Cable covers - 3X Snap action mechanism for manual operation Cable box for front termination of the cable suitable upto 3 core 185 Sqmm, 11 KV XLPE cable Right angle non-touch proof Termination boots -1 Set (R,Y,B) (vi) Manual operated 630 A Vacuum circuit breaker having spring stored mechanism. Three position disconnector/earthing switch downstream vacuum circuit-frreaker. Three position single spring mechanism f6r disconnector/earthing switch’ "Live Cable” LED Indicators thru Cap'acitffr Voltage Dividers mounted onthe bushings. ' Short time breaking current - 21 KA/3 sec Making Capacity - 52.5 kAp \ Auxiliary contacts -1 NO + 1NC \
Power frequency withstand voltage -, 38KV Impulse withstand voltage - 98KV Nominal operating gas pressure -1.4 Bar abs. Front cover mechanism - IP2X Cable covers - 3X Green(ON)/Red(OFF) push buttons to operate VCB. 30/C + 1E/F self powered numerical protection relay with Low and High set for Over current and Earth Fault. Resin cast ring core protection CT plate mounted type : 30/1 A, 5P10, 2.5 VA - 3 Nos Mechanical ON/OFF/EARTH/Spring charge Indication of Note: rate including fixing arrangement along with suitable rating copper bus bar suitable for existing Schneider make RMU model No -FBX-RE
Supply, installation, testing & commissioning of 11 KV Indoor type extensible RMU floor mounted 3 LBS with internal copper bus bars, consisting of 630 Amp fixed manual Load Break Switches . All live parts, bus bars, LBSs connections of RMU shall be enclosed in one tank to avoid multiple interconnections & sealed for life robotically welded non magnetic and non ferrite grade stainless steel tank Grade 304 of minimum 2.5 mm thick having IP67 degree of protection filled with SF6 gas as insulation with leakage rate less than 0.1% per year tested as per IEC 62271-200. Location: New Sub Stn at proposed igloo (I) The unit shall have front cable entry for ease of installation and shall have site replaceable bushings for ease of troubleshooting during breakdown.RMU should be complete with all accessories such as Terminal boots, VPIS, cable supports, all front cable terminations, mechanical indications for Load break switch ON/OFF, Manometer as per with IEC standards 62271-200, 60056, 60129, 60265, 60298, 60420, 60529 and 60694. Altitude of installation up to 1000m as per IEC 60120. Extensible Bushings,if applicable shall be bolted
type top mounted outside the tank for connection of external bus bar .Also, the outer enclosure shall cover the full length of the switchgear.to ensure IP3X+IP54 protection for cable boxes . (II) The unit shall be internal arc proof 21 kA for 1 sec. for tank+Cable Box ,and tested and totally safe for human beings. (III) Bidder shall provide type test report to prove compliance to the ‘Internal fault IAC-AFLR as per IEC 62271- 200.lnternal arc proof & testing shall be done with enclosure door in open condition, with switching devices in operation mode. The unit shall include the following with all necessary standard fitting required at site. (IV) 630A Load Break Switch module for making of fault current alongwith Earth Switch of full making capacity Short time withstand current - 21KA/ 3 sec Making Capacity - 52.5kAp ; Auxiliary contacts -1 NO + 1 NO Power frequency withstand voltage - 38kV Impulse withstand voltage - 95kV
Nominal operating gas pressure -1.4 Bar abs. Front cover mechanism - IP2X Cable covers - 3X Snap action mechanism for manual operation Cable box for front termination of the cable suitable upto 3 core 185 Sqmm, 11 KV XLPE cable Right angle non-touch proof Termination boots -1 Set (R,Y,B)
Supply, laying & testing HT cable aluminium conductor, standared compact circular aluminium conductor screened with extruded semi connducting compound, XLPE insulated , insulation screening with extruded semi conducting compound in combination with copper tape, core laid up, innersheath of PVC, galvanised steel flat strip, and overall pvc sheathed cable conforming to IS 7098 (PART-2) 2011 suitable for 11000 Volt (E) grade of cross sectioal area 95 Sqmm x 3 core complete all as specified and directed.
M&L L earthing complete with copper earth plate electrode 600 mm x 600 mm x 3.15 mm thick, burried directly in ground in vertical position, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below ground level. The earth plate to be connetced with copper earthing strip of size 20 mmx 3mm thick by means of brazing between copper strip and earth plate min 45 cm in strip also to be joined by brazing only. The copper earthing strip to be protected by galvanised iron pipe 40 mm bore (medium grade) up to ground level and there after with 40mm dia HDPE pipe up to test point. Earthing ' shall include provision of funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) up to 90 cm all around earth plate further filled with 60 cm thick Tibba sand and 2nd layer with 30 cm of Magnesium sulphate powder (compact thickness), 3rd layer with tibba sand up to ground level.
M & L for earthing complete with Gl earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly in ground vertical position , earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below ground level. The earth plate to be connetced with galvanised iron earthing strip of size 32 mm x 6 mm by means of nuts, bolts, chcek nuts and washers made of galvanised iron or steel earthing strip to be protected by galvanised iron pipe 40 mm bore (medium grade) up to ground level and there after with 40mm dia HDPE pipe up to test point. Earthing shall be include with providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) up to 90 cm all around earth plate further filled with 60 cm thick Tibba sand Earthing shall also be include for providing concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work all as spcified and directed, (for body earthing transformer and LT panels)
S&F LT Panel Outdoor type floor mounted free standing dust and vermin proof panel / DB with IP-42 protection, CPR1 approved, frame fabricated out of 40mm x 40mm x 4mm angle iron, 3.15 mm thick CRCA sheet for entire outer panel with single door and locking arrangements & 1.6 mm for inner compartment with 40mmx4mm flat Iron, including Separate cubicle chamber with cable alley not less-than 300mm width for installation/connecting switchgears with the main bus bar using aluminium bus link or copper conductor flexible wires suitable for switch rating and connecting outgoing terminals of the switchgear with terminal blocks of appropriate current rating using flexible copper wires duly terminated by cable lugs and thimbles, MS surfaces epoxy based powder coated, shade as approved over 2 coats of red oxide primer, surfaces pre-treated in seven tank process for de-greasing, de-rusting & Phosphated, panel having front and rear opening and provision for installation of separate cable alleys, busbar chamber and switchgear compartments, Provision in cable alleys for bottom cable entry for incoming & outgoing cables, affixing MV danger plate at suitable intervals / locations including erection, testing and commissioning complete all as specified and directed including fixtures amd fitments mentioned:-. Location Sub Station Admin Bldg
Outgoing:- Separate cubical chamber with a cable alley not less than 300 mm width for installation/connecting the following switch gear with the main bus bar using copper bus link suitable to the switch rating and connecting outgoing terminals of the switch gear with terminal blocks of appropriate current rating using flexible copper wires duly terminated by cable lugs and thimbles. (i) MCCB 4 pole 415 Volt 400 Amps , 36 kA - 01 (Admin bldg) (ii) MCCB 4 pole 415 Volt 125 Amps, 25 kA - 01 (SAMC-1) (iii) MCCB 4 pole 415 Volt 100 Amps ,25kA - 02.(Existing LT Panel & spare) Note:-Contractor shall submit the GA drawings of LT Panel for approval of GE before placing the order
S&F LT Panel Outdoor type floor mounted free standing dust and vermin proof panel / DB with IP-42 protection, CPRI approved, frame fabricated out of 40mm x 40mm x 4mm angle iron, 3.15 mm thick CRCA sheet for entire outer panel with single door and locking arrangements & 1.6 mm for inner compartment with 40mmx4mm flat Iron, including Separate cubicle chamber with cable alley not less than 300mm width for installation/connecting" switchgears with the main bus bar using aluminium bus link or copper conductor flexible wires suitable for switch rating and connecting outgoing terminals of the switchgear with terminal blocks of appropriate current rating using flexible copper wires duly terminated by cable lugs and thimbles, MS surfaces epoxy based powder coated, shade as approved over 2 coats of red oxide primer, surfaces pre-treated in seven tank process for de¬greasing, de-rusting & Phosphated, panel having front and rear opening and provision for installation of separate cable alleys, busbar chamber and switchgear compartments, Provision in cable alleys for bottom cable entry for incoming & outgoing cables, affixing MV danger plate at suitable intervals / locations including erection, testing and commissioning complete all as specified and directed including fixtures amd fitments mentioned Location SAMC-1
OutGoing: (i) MCB TPN 4 pole 415 Volt 32 Amps , 10kA - 05 Nos (ii) MCB SPN 32 Amps , 10kA - 01 MCB SPN 20 Amps , 10kA - 03 Timer switch complete with contactor, timer etc - 02 Set Note:- Contractor shall submit the GA drawings of LT Panel for approval of GE before placing the order
S&F LT Panel Indoor type floor mounted free standing dust and vermin proof panel / DB with IP-42 protection, CPRI approved, frame fabricated out of 40mm x 40mm x 4mm angle iron, 2.0 mm thick CRCA sheet for entire outer panel with single door and locking arrangements & 1.6 mm for inner compartment with 40mmx4mm flat Iron, including Separate cubicle chamber with cable alley not less than 300mm width for installation/connecting switchgears with the main bus bar using aluminium bus link or copper conductor flexible wires suitable for switch rating and connecting outgoing terminals of the switchgear with terminal blocks of appropriate current rating using flexible copper wires duly terminated by cable lugs and thimbles, MS surfaces epoxy based powder coated, shade as approved over 2 coats of red oxide primer, surfaces pre-treated in seven tank process for de-greasing, de-rusting & Phosphated, panel having front and rear opening and provision for installation of separate cable alleys, busbar chamber and switchgear compartments, Provision in cable alleys for bottom cable entry for incoming & outgoing cables, affixing MV danger plate at suitable intervals / locations including erection, testing and commissioning complete all as specified and directed including fixtures amd fitments mentioned Location Igloo Building
OutGoing: (i) MCCB 4 pole 415 Volt 63 Amps, 10kA - 09 Nos (ii) MCB TPN 4 pole 415 Volt 40 Amps, 10kA -1 Nos (iii) MCB TPN 4 pole 415 Volt 32 Amps , 10kA - 05 (iv) MCB SPN 20 / 32 Amps , 10kA - 02 No (v) Timer switch complete with contactor, timer, MCB etc - 01 Set Note:- Contractor shall submit the GA drawings of LT Panel for approval of GE before placing the order
S&F LT Panel Indoor type floor mounted free standing dust and vermin proof panel / DB with IP-42 protection, CPRI approved, frame fabricated out of 40mm x 40mm x 4mm angle iron, 2.0 mm thick CRCA sheet for entire outer panel with single door and locking arrangements & 1.6 mm for inner compartment with 40mmx4mm flat Iron, including Separate cubicle chamber with cable alley not less than 300mm width for installation/connecting switchgears with the main bus bar using aluminium bus link or copper conductor flexible wires suitable for switch rating and connecting outgoing terminals of the switchgear with terminal blocks of appropriate current rating using flexible copper wires duly terminated by cable lugs and thimbles, MS surfaces epoxy based powder coated, shade as approved over 2 coats of red oxide primer, surfaces pre-treated in seven tank process for de-greasing, de-rusting & Phosphated, panel having front and rear opening and provision for installation of separate cable alleys, busbar chamber and switchgear compartments, Provision in cable alleys for bottom cable entry for incoming & outgoing cables, affixing MV danger plate at suitable intervals / locations including erection, testing and commissioning complete all as specified and directed including fixtures amd fitments mentioned :-. Location MT Sub-station
S&F LT Panel Outdoor type floor mounted free standing dust and vermin proof panel/DB with IP-42 protection,CPRI approved, frame fabricated out of 40mm x 40mm x 4mm angle iron, 3.15 mm thick CRCA sheet for entire outer panel with single door and locking arrangements & 1.6 mm for inner compartment with 40mmx4mm flat Iron, including Separate cubicle chamber with cable alley not less than 300mm width for installation/ connecting switchgears with the main bus bar using aluminium bus link or copper conductor flexible wires suitable for switch rating and connecting outgoing terminals of the switchgear with terminal blocks of appropriate current rating using flexible copper wires duly terminated by cable lugs and thimbles, MS surfaces epoxy based powder coated, shade as approved over 2 coats of red oxide primer, surfaces pre-treated in seven tank process for de¬greasing, de-rusting & Phosphated, panel having front and rear opening and provision for installation of separate cable alleys, busbar chamber and switchgear compartments, Provision in cable alleys for bottom cable entry for incoming & outgoing cables, affixing MV danger plate at suitable intervals / locations including erection, testing and commissioning complete all as specified and directed including fixtures amd fitments mentioned :- Location SAMC-2
Outgoing: (i) MCB TPN 4 pole 415 Volt 40 Amps , 10kA - 01 Nos (spare) (ii) MCB 4 pole 415 Volt 32 Amps , 10kA - 04 Nos (garrages) (iii) Timer switch complete with contactor, timer etc - 01 Set ;; ; (iv) MCB SPN 32 Amps , 10kA - 01 No (v) MCB SPN 20 Amps , 10kA - 02 No Note:- Contractor shall submit the GA drawings of LT Panel for approval of GE before placing order
S&F LT Panel Outdoor type floor mounted free standing dust and vermin proof panel / DB with IP-42 protection, CPRI approved, frame fabricated out of 40mm x 40mm x 4mm angle iron, 3.15 mm thick CRCA sheet for entire outer panel with single door and locking arrangements & 1.6 mm for inner compartment with 40mmx4mm flat Iron, including Separate cubicle chamber with cable alley not less than 300mm width for installation/connecting switchgears with the main bus bar using aluminium bus link or copper conductor flexible wires suitable for switch rating and connecting outgoing terminals of the switchgear with terminal blocks of appropriate current rating using flexible copper wires duly terminated by cable lugs and thimbles, MS surfaces epoxy based powder coated, shade as approved over 2 coats of red oxide primer, surfaces pre-treated in seven tank process for de-greasing, de-rusting & Phosphated, panel having front and rear opening and provision for installation of separate cable alleys, busbar chamber and switchgear compartments, Provision in cable alleys for bottom cable entry for incoming & outgoing cables, affixing MV danger plate at suitable intervals / locations including erection, testing and commissioning complete all as specified and directed including fixtures amd fitments mentioned :-. Location CONTROL ROOM
OutGoing: (i) MCB TPN 32 Amps, 10kA - 02 Nos <ii) MCB TPN 40 Amps, 10kA - 01 Nos (iii) MCB 20 Amps, 10kA -01 Nos (iii) Timer switch complete with contactor, timer, MCB etc - 01 Set Note:- Contractor shall submit the GA drawings of LT Panel for approval of GE before placing the order
S&F LT Panel Outdoor type floor mounted free standing dust and vermin proof panel / DB with IP-42 protection, Each CPRI approved, frame fabricated out of 40mm x 40mm x 4mm angle iron, 3.15 mm thick CRCA sheet for entire outer panel with single door and locking arrangements & 1.6 mm for inner compartment with 40mmx4mm flat Iron, including Separate cubicle chamber with cable alley not less than 300mm width for installation/connecting switchgears with the main bus bar using aluminium bus link or copper conductor flexible wires suitable for switch rating and connecting outgoing terminals of the switchgear with terminal blocks of appropriate current rating using flexible copper wires duly terminated by cable lugs and thimbles, MS surfaces epoxy based powder coated, shade as approved over 2 coats of red oxide primer, surfaces pre-treated in seven tank process for de¬greasing, de-rusting & Phosphated, panel having front and rear opening and provision for installation of' separate cable alleys, busbar chamber and switchgear compartments, Provision in cable alleys for bottom cable entry for incoming & outgoing cables, affixing MV danger plate at suitable intervals I locations including erection, testing and commissioning complete all as specified and directed including fixtures amd fitments mentioned :-. Location MT SECTION
Outgoing :Separate cubical chamber with a cable alley not less than 300 mm width for installation/connecting the following switch gear with the main bus bar using aluminium bus link or copper conductor flexible wires suitable to the switch rating and connectingjDutgoing terminals of the switch gear with terminal blocks of - appropriate current rating using flexible copper wires duly terminated by cable lugs and thimbles. OutGoing: (i) MCB TPN 4 pole 415 Volt 32 Amps, 10kA - 05 (ii) MCB SPN 20 Amps,10kA - 02 No (iii) MCB SPN 32 Amps, 10kA - 01 No (iv) MCB SPN 10 Amps, 10kA - 01 No (v) MCB SPN 40 Amps , 10kA - 01 No (vi) Timer switch complete with contactor, timer, MCB etc - 01 Set Note:- Contractor shall submit the GA drawings of LT Panel for approval of GE before placing the order
Taking out carefully old HT cable of size 95 sq mm x 3 Core, XLPE/PVC sheathed 11000 volts grade armoured with aluminum conductor carefully of any size from trenches, poles, under floor etc for further use/disposal all as specified and directed. Note : Earth work will be measured & paid separately.(ii) Serviceable cable cover to be staged at site properly for re-use.
Shifting the serviceable cable after testing and relaying HT cable 11000 volt grade of size 95 Sqmm 3 core in new location ,in trenches and testing and connecting complete. (Note: Excavation, earth work, Sand and PCC covers will be measured and paid separately under relevant items).
Supply & lay HDPE split pipe of bore 150mm in around existing GI pipe line and LT/HT cable include filling PCC around the pipe for crossing road complete all as specified and directed.
Material and labour for making cross hole suitable for 80/100mm dia bore pipe including passing GI pipe of size 80/100mm dia, below the road with the help of pressure pipe/ boring tools for passing the cable and removing of surplus soil to a distance not exceeding 100 mtr from work site all as directed. Note: GI pipe to be measured and paid separately under relevant items complete all as specified and directed.
Dismantling, takingout existng LT Poles complete with street light carefully for use from its original position and shifting to new location complete all as specified and directed.
M&L for erection only of LT Poles 9 m long complete with streetlight of any type in truly vertical position with and including PCC for foundation and coping complete all as specified and directed.
S&F Automatic power factor correction panel of capacity 100 KVAR in 6 stages with micro processor based by Supply, assembly, erection, testing and commissioning of Indoor type floor mounted free standing, dust and vermin proof panel/DB with IP-42 protection CPRI approved ISO 9001 certified frame fabricated out of 40mm x 40mm x 4mm angle iron, 2.00 mm thick CRCA sheet for entire outer panel with single door and locking arrangements & 1.6 mm for inner compartment with 40mmx4mm flat Iron, MS surfaces epoxy based powder coated, shade as approved over 2 coats of red oxide primer, surfaces pre-treated in seven tank process for de¬greasing, de-rusting & Phosphated, Panel / DB having front and rear opening for installation of separate cable alleys, busbar chamber and switchgear compartments, Provision in cable alleys to be kept for-bottom cable entry for incoming & outgoing cables.
A clear space of 300mm to be kept from floor level for switchgear compartment. Air ventilation breathers to be provided for heat dissipation. Suitable sized knock-out holes for cable glands shall be provided. Each compartment shall be numbered/lettered as per the approved drg. Affixing MV danger plate as suitable intervals/locations, fully internally wired with suitable size of thimbles. Incoming / outgoing internal connection with PVC insulated PVC sheathed multistranded copper wire of suitable size all as directed & comprising the following :- BUS BAR CHAMBER (a) 200 Amp 3 Strips & Neutral Strip 100 Amp, Aluminium conductor, with colour coded heat shrinkable sleave and shall be mounted on non hygroscopic, non combustible, track resistant, high strength DMC material, interconnection of all incomings & outgoings. INSTRUMENT CHAMBER :- (i) Digital Multifunction Meter- 01 Set. (ii) Red,Yellow,Green Phase indicating Lights LED type 220V AC-1 Set. (Set of three). (iii) Protection MCB 6 A SP C Series-1 Set. (Set of three). INCOMING SUPPLY (i) MCCB 160 Amps 25 KA , 4 Pole with Adjustable thermal & magnetic release 415 volts , 50Hz =01 No., (ii) Capacitor Duty Contactor suitable for 1 X 50 + 1 X 20 + 2 X 10 + 2 X 5 KVAR Capacity . (iii) Power Contactor 18 A 3 Pole for 2 , 5 KVAR -’.02 Nos." (iv) Contactor shalJ-be protected with MCB TP 10 .KA
S&F LT Panel Outdoor type floor mounted free standing dust and vermin proof panel / DB with IP-42 protection, CPRI approved, frame fabricated out of 40mm x 40mm x 4mm angle iron, 3.15 mm thick CRCA sheet for entire outer panel with single door and locking arrangements & 1.6 mm for inner compartment with 40mmx4mm flat Iron, including Separate cubicle chamber with cable alley not less than 300mm width for installation/connecting switchgears with the main bus bar using aluminium bus link suitable for switch rating and connecting outgoing terminals of the switchgear with terminal blocks of appropriate current rating using flexible copper wires duly terminated by cable lugs and thimbles, MS surfaces epoxy based powder coated, shade as approved over 2 coats of red oxide primer, surfaces pre-treated in seven tank process for de-greasing, de-rusting & Phosphated, panel having front and rear opening and provision for installation of separate cable alleys, busbar chamber and switchgear compartments, Provision in cable alleys for bottom cable entry for incoming & outgoing cables, affixing MV danger plate at suitable intervals / locations including erection, testing and commissioning complete all as specified and directed including fixtures amd fitments mentioned below:- Location Admin Bldg Qty - 01
(iii) MCB TPN 4 pole 415 Volt 32 Amps ,10kA - 02 (iv) MCB SPN 32 Amps , 10 kA - 01 (v) MCB SPN 20 Amps , 10kA - 02 (iv) Timer switch complete with contactor, timer, MCB etc - 02 Set Note:- Contractor shall submit the GA drawings of LT Panel for approval of GE before placing the order
Street Lights
S&F conventional LED street light 20 watt 230 volts pressure die cast aluminium housing, heat resistant toughened glass with frame, IP protection 66 sealed driver complete all as specified and directed .
S&F conventional LED street light 35 watt 230 volts pressure die cast aluminium housing, 1ieat resistant toughened glass with frame, IP protection 66 batter sealed driver complete all as specified and directed
S&F Sintex box for luminaries, weather proof made out of PVC/HDPE fire retardant, non fusing, shock & rust proof, single piece moulded/SMC housing and SMC cover with hinged door, pole mounting type comprising of aluminium busbar TPN of 32 Amps with base of minimum size 300x200x100 mm, fixed on pole with MS, clamps 30x5 mm with necessary nuts, washer Street light)
S&F PVC flat 3 core core copper cable of size 1.5 Sqmm for connection from junction box to light fitting and as specified and directed. .
Supply & installation of 15 M high mast shaft in two section suitbale for 50 m/sec wind speed along with head frame, luminiaries carriage suitable for 08 luminiaries suitable for 250W LED fitting in symmetrical arrangement and other accesories manufactured in factory with raising lowering system comprising double drum winch, 5mm diameter SS wire rope, trailing cable, connector, integral power tool motor, manual handle, junction box, lightining finial including supply of foundation bolts manufactured from special steel along with nuts, washers, anchor plate and common template and outdoor stand mounted feeder pillar with 32A TPN MCB incomer, single dial time switch, 25A TP contactor for the automatic switching of luminiaries, power tool control with 2 No 9A contactors and raise lower push button, Incoming 35 sq. mm and out going 16 & 2!5.sq. mm terminals. Note : LED fitting shall be measured separately under relevant item of schedule . HIGH MAST SYSTEM Height of mast : 15 Meter No. of Section : Two Material Construction : S355 Grade as per BS-EN 10 025 Base dia and top diameter (A/F) : Top : 150mm : Bottom : 460mm Cross section of Mast : 20 Side polygon Standard for Galvanisation : as per BS EN ISO 1461 Size of Opening and door at base : 1200 x 250mm
Diameter of base plate : 670mm Thickness of base plate : 25mm Lighting protection finial : GI single spike of lenth 1200mm Max. wind speed : 50m/s as per IS 875 (Part III) Number of foundation bolts : 12 Nos PCD of foundation bolts : 590 mm Type / diameter / length of foundation bolts : TS 600/30 mm dia/850 mm long
FOUNDATION DETAILS 1. Excavation dimensions 2800 x 2800 x 1500mm size 2. Lean Concrete 100 mm thick {1: 4: 8) D2 (using 40mm graded Aggregate) 3. Matt bars 12mm dia TMT Bars @ 200C/C both ways in double layers 4. RCC (1:1.5: 3) 2600 X 2600 X300MM as in footing 5. RCC (1 :1.5: 3) 1000 X 1000 X 1400 MM (1100MM below GL and 300 mm above GL) 6. 08 Nos 16mm dia TMT Bars 4 at comers 4 at centres of pedastal col as main bar with 600mm long craking at bottom over matt bars 7. 16 Nos 12mm dia TMT main bars (4 Nos each at 4 side with 600mm long cranking at bottom over matt bars. 8. 10mm dia TMT bars @ 150mm C/C as Stirrups
9. 300mm dia 850mm long foundation bolts 08 Nos inserted in to 16 mm thick anchoring plate 590mm dia at bottom with pointed galvanised nut one each at bottom and top of plate. 10. Foundaiton bolt min clearance 150mm above pedestal col to rest high mast base plate 25mm thick over the bolts. Galvanished nuts 01 number at bottom of base plate 2 Nos at top of base plate. Note : The unit rate is inclusive of necessary formwork, RFR removal of surplus earth, external finishes and other unforeseen items all as directed by Engr - in- Charge
LUMINAIRES CARRIAGE Material of construction : 50NB ERW Class B-M.S Pipe Diameter of carriage ring (mm) : 535 mm (ID) Construction : 06 Arm, Welded, 2 Sections Load carrying capacity : 08 Luminaire TRAILING CABLE Conductor : Copper, 5 core, 2.5 Sqmm Insulation : EPR insulated PCP scheathed No.of circuits per mast : One WINCH / POWDER TOOL Type /SWL of winch : Double drum, SWL 750 Kg - SGDD Method of Operation : Integral Motor Motor Capacity : 1.0 HP (Including suitable starter) No of Speeds : 6 Pole, single speed Torque Limitor : With Mechanical tripping Facility
STAINLESS STEEL WIRE ROPE Grade / construction : AISI 316, 7/19 Construction Number of Ropes : Two Continuous Diameter (mm) : 6 mm Breaking load Capacity : 2350 Kg x 2
Supply, install,testing and commissioning 250 watt LED flood light IP 65 with the help of suitable acessories including electrical wiring of luminaries with all wiring materials all as specified and directed
M&L earthing complete with copper earth plate electrode 600 mm x 600 mm x 3.15 mm thick, burried directly in ground in vertical position, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below ground level. The earth plate to be connetced with copper earthing strip of size 20 mmx 3mm thick by means of brazing between copper strip and earth plate min 45 cm in vertical length and copper strip also to be joined by brazing only. The copper earthing strip to be protected by galvanised iron pipe 40 mm bore (medium grade) up to ground level and there after with 40mm dia HDPE pipe up to test point Earthing shall include provision of funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) up to 90 cm all around earth plate further filled with 60 cm thick Tibba sand and 2nd layer with 30 cm of Magnesium sulphate powder (compact thickness), 3rd layer with tibba sand up to ground level.
STANDBY DG SET
Supply, installation, testing and commissioning of silent Diesel Engine driven generating set with AMF panel 250 KVA with coolent cooled engine of suitable BHP for 200 KW power genaration @ RPM 1500, brushless frame with silencer and canopy for sound less mode (sound level not exceeding level specified by central polution board) and all engine accessories such as self starter, alternator/ dynamo and 200 KW / 250 KVA electric alternator 415 Volts 3 phase, 4 wire, 50 Hz, voltage regulation + 1% , insulation class H coupled to engine with suitable coupling and base frame on foundation as recommended by the manufacturer and consisting of other electrical components, fuel tank of suitable capacity with level indicater installed on suitable stell frame with PCC foundation as per manufacturer instruction , Power command genset controller, Duel spin or fuel filter Dry type air cleaner, shut off coil with safeties for LLOP/ HWT, fuel pipes, bar metre, hour meter, oil temparature guage, ammeter, ignition switch, radiator with cooling system, maintenance free battery, including suitable size of copper cable leads with terminal, all mountings, accessories and necessary foundation and AVM pads complete as per manufaturer recommendations and all as specified and as directed
(A) Prime MoverSuitable for driving 200 KW / 250 KVA alternator water cooled battery start Diesel Engine of adequate capacity confirming of IS -10001/1002 and fuel tank suitable for 12 hrs running capacity mounted on MS frame pedestal support with anti-vibration mounting rated for continous running capable of taking 10 % over load for one hrs in any 12 hour opertaion complete with the following standard accessories:- (a) Fly wheel to match with the flexible coupling (b) Flexible couipling with guard (c) lubricating oil filter, fuel filter paper element type (d) Air cleaner oil bath type / dry type (e) Blower type fan and radiator (f) Governor of class A Governing as per IS 1601 of DS 649/1958 (g) Startor, motor for elctric start complete with dynamo alternator, lead acid batteries heavy duty of capacity 12 V 150 AH or as recommended by the manufacturer and all as specified and directed . (h) Hour meter and RPM indicator (j) Mineral wool aluminium foil insulation of entire length of exhaust pipe with suitable dia.
(k) Instrument panel duly wired comprising the following including protection for low lube oil high temperature (l) Lube oil pressure guage (n) Battery charge indicator meter (m) Starting switch with key (n) Lub oil temparature (o) Water temparature (B) Alternator:- 200 KW / 250 KVA at 0.8 PF Brushless self excited self regulerd 3 phase 50 Hz 415 volt 1500 rpm 4 wire screen protected drip proof free from simulation problem continous rating confirming to BS 2613 complete with automatic voltage regulator O/P voltage regulated between +1% set voltage from no load to full load. (C) Automatic Main Failure Panel AMF Panal for 200 KW / 250 KVA Dg set fabricated out of sheet steel factory made suitable for floor mounting hinged from panel for easy asessebility with suitable rated bus bar internal wiring and with provision for connecting incoming / outgoing lead with the following aceesories.
(p) Indicator lamp for bty, Set for easiliy accessible control fuses, Set for relays to auto start the engine on main failure and low voltage, Emergency trip Note (i) Any fittings/ fixtures which are necessary for proper functioning of the DG set shall also be deemed include in the unit rate quated and shall be provided by the contractor without any extra cost to the Deppt. (ii) Necessary foundation for installation of DG set shall also be provided as per manufacturers recommendations and cost deemed to be inclusive in the rate quated for this item. (iii) All testing equipments are to be arranged by the contractor and testing shall be carried out by the contractor in presence of Engr in Charge and testing result duly signed by the Engr- in- Charge and the contractor shall be kept in record. (iv) Rate quated by the contractor including the.rate of first filling of lubricating oil, coolant from DG set to AMF panel must be outside the canopy. (v) Drawings / cataloge for DG set and AMF panel got approved by the HQWAC before odering to the manufaturer
M&L earthing complete with copper earth plate electrode 600 mm x 600 mm x 3.15 mm thick, burried directly in ground in vertical position, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below ground level. The earth plate to be connetced with copper earthing strip of size 20 mm x 3mm thick by means of brazing between copper strip and earth plate min 45 cm in vertical length and copper strip also to be joined by brazing only. The copper earthing strip to be protect by galvanised iron pipe 40 mm' bore (medium grade) up to ground level and there after with 40mm dia HDPE pipe up to test point. Earthing shall include provision of funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) up to 90 cm all around earth plate further filled with 60 cm thick Tibba sand and 2nd layer with 30 cm of Magnesium sulphate powder (compact thickness), 3rd layer with tibba sand up to ground level.
Som Projects Pvt. Ltd.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid