| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | FIRST₹38.6 LAccepted-AOC 26 3 3RD CROSS GANESHA BLOCK SULTANPALYA RT NAGAR POST BANGALORE 560 032 | BANGALORE | BANGALORE | KARNATAKA | 560032 | FIRST | Accepted-AOC BEING LOWEST | |
| 2 | SECOND₹38.7 LRejected-Finance NO 12 5TH B CROSS SHARADAMBA NAGAR M E S ROAD BANGALORE 560013 | BANGALORE | BANGALORE | KARNATAKA | 560013 | SECOND | Rejected-Finance BEING NOT LOWEST | |
| 3 | THIRD₹39.9 LRejected-Finance | THIRD | Rejected-Finance BEING NOT LOWEST | |
| 4 | FOURTH₹40.8 LRejected-Finance | FOURTH | Rejected-Finance BEING NOT LOWEST | |
| 5 | FIFTH₹41.4 LRejected-Finance SITE NO 29 30 1ST CROSS NAGAPPA REDDY LAYOUT KAGGADASAPURA CV RAMAN NAGAR PO BANGALORE 560 093 | BANGALORE | BANGALORE | KARNATAKA | 560093 | FIFTH | Rejected-Finance BEING NOT LOWEST |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
13 Feb 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) MARATHAHALLI
GE AF MARATHAHALLI WIND TUNNEL ROAD, KEMPAPURA, YEMALUR POST, BANGALORE. PIN- 560037
PROVISION OF WORK SERVICES FOR PREVENTION OF WATER LOGGING ALONGWITH WITH ALLIED WORKS AT VV CAMP IAM BANGALORE
2023_MES_574419_1
8601/E8
Open Tender
Civil Works
Item Rate
180 days
GE (AF) MARATHAHALLI
AS PER ENIT
10 documents required · 10 mandatory
₹500
GE (AF) MARATHAHALLI
₹80,000
Yes
11 Apr 2023
11 Jan 2023
19 Feb 2023
11 Jan 2023
13 Feb 2023
31 Jan 2023
Amount
Excavation in trenches not exc 1.5 mtr wide and n.exc. 1.5 mtr in depth for foundation etc. for shafts, wells, manholes etc. n.exc 10 Sqm on plan and n.exc 1.5 mtr in depth and getting out in hard dense soil complete all as specified and as directed.
M&L for PCC (1:4:8) type D2 using 40mm graded crushed stone aggregate as in foundation filling and mass concrete complete all as specified and as directed. .
M&L for PCC solid block masonry in PCC blcoks of 1:3:6 type C1 with 20mm graded crushed stone aggegate exc.10cm in width and setting in mortar 1:6 complete all as specified and as directed.
Supply and filling moorum/red bajri filling in floors or pavings laid in layers n exc 15cm thick each, spread, levelled and rammed including watering complete all as specified and as directed.
M&L for hard core of gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15cm thick each, watered and rammed to a true surface complete all as specified and as directed.
M&L 75 mm thick cement concrete 1:4:8, type D-2 (40mm graded crushed stone aggregate) as in sub base floors complete all as specified and as directed.
M&L 150 mm thick cement concrete 1:2:4,Type B-2 (40mm graded crushed stone aggregate) finished even and smooth without using extra cement all as specified and as directed
M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces finished even and fair without using extra cement in cement mortar 1:4 complete all as specified and as directed..
M&L for PCC 1:2:4 type B1 using 20mm graded crushed stone aggregate as in bed blocks including necessary form work complete all as specified and as directed.
S&F of mild steel bolts purpose made with hexagonal or square head one end and screwed the other or screwed both ends each screwed end fitted with wahsers and one hexagonal or square nut 30cm long with dia of neck 20 to 25mm complete all as specified and as directed.
S&F Steel work in tubular trusses and purlins including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S 1161-1979 grade St-240 complete all as specified and as directed.
S&F mild steel tubular work as in single columns/stanchions complete including MS plates cut or notched (ordinary or counter sunk) forming holes using ERW or induction butt welded tubes conforming to I.S 1161-1979 grade St-240 complete all as specified and as directed.
S&F Pre-laminated galvalume aluminium zinc coating GI based corrugated steel sheet 0.5mm thick of an approved colour having tensile strength of 550 Mpa as in roof covering in any curvature, fixed with self tapping screws as specified.
S&F 0.63 mm thick Plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 as in roof covering in any curvature as specified.
M&L for prepration of preiovisely untreated or new steel surface of any description over 10 cm in width or girth and applying two coats of synthetic enamel paint over and including a coat of primer, complete all as specified & as directed .
M&L for prepararion of new plastered surface of wall and applying two coats of cement base paint over a coat of primer complete all as specified and as directed.
Rough excavation not exceeding 1.5 m deep and getting out in soft/loose soil complete all as specified and as directed.
Excavating over areas n exc 1.5m deep and getting out in hard dense soil complete all as specified and as directed.
Excavating over areas exc 1.5m and n exc 3.0m deep and getting out in hard dense soil complete all as specified and as directed.
Use and waste form work to sides of concrete foundation/footing, plinth beams & similar work vertical or batter fair finished surfaces of concrete complete all as specified and as directed..
Use and waste form work to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pilasters, buttresses, etc, vertical or to batter fair finished surfaces of concrete flat all as specified and as directed.
M&L for RCC M-20 design mix concrete (using 20mm graded crushed stone aggregate) as in foundations, including rafts footings, foundations beams, plinth beam, bases for col etc all as specified and as directed
M&L for RCC M-20 design mix concrete (using 20mm graded crushed stone aggregate) for Walls. Retaining walls, basement walls, ballast walls and like any thickness all as specified and as directed
Returning, filling in, including spreading, leveling, watering & well ramming in layers not exc 25 cm each in hard /dense soil complete all as specified and as directed..
Removing excavated material n. exe.250 m but n exc. 500m & deposited where directed at a level n exc. 1.5m above the starting point complete all as specified and as directed.
S&F of 50mm bore High density polyethylenepipe of pressure rating 6Kgf/Sqcm as in weep holes complete all as specified and as directed.
Demolition of brickwork or stone masonry built in cement mortar complete all as specified and as directed.
Demolition of Cement Concrete (unreinforced) of any description andin any position not otherwise specifically provided for, complete all as specified and directed.
Taking down cement or cement lime plaster on brick, concrete or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed.
M&L for precast cement concrete block masonry with solid blocks exc 10cm in width and setting in CM 1:6 except blocks complete all as specified and as directed.
M&L for plain Cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in surface channels, drains etc. complete all as specified and as directed.
Extra for forming fair finished drain or channel up to 55 cm inner girth in cement concrete, using extra cement incl forms, moulds, mitred/stopped ends etc. complete all as specified and as directed.
M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces finished even and fair without using extra cement in CM 1:4 complete all as specified and as directed.
M&L for precast RCC slabs in cement concrete 1:2:4 type B1 using 20mm aggregate as in cover slabs to drains set in CM 1:6. (Reinforcement measured and paid seperately) including necessary form work complete all as specified and as directed..
S&F for framed work such as grill gratings etc with ends of bars shouldered and /or reveted or forged into spikes, framed guard bars barred iron doors, ladders framed balusters walk ways, rallings, frameowrk of watertanks and similar work confirming to Fe-290 Gde E-165
Removing building materials etc to a distance of 1.00Km complete all as specified and as directed.
M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete as specified.
Description all as per item No37 above 5 but 6 to 8mm dia bars.
Supply and fix Non clogging submerssible pump electric driven 415 V 10 HP single stage maximum flow rate 1200 LPM 25 M head
Supply only Non clogging submerssible pump electric driven 415 V 10 HP single stage maximum flow rate 1200 LPM 25 M head (Stand by )
Boring of holes under road ,pavement hard standing by trenchless technology using ultra sounding,technique including HDPE pipe 150 mm dia
Supply and Fixing Sluice valve both side flanged and ISI marked (IS-780) of sluive valve cast iron body with stainless spindle and fly nuts, class PN-1.6 and cast iron hand wheel and joining with nut, bolt,washers and rubber insertion packing 6 mm thick etc of sizes 100 mm dia
S & F HDPE Pipe 100MM with all fittings and connections, PE-100 for Delivery line
Supply and laying Submerssible cable 6 sqmm flat type 4 core, 1100 V
Supply and fixing nylon rope 16mm dia
Excavation in trenches in Soft / Loose soil not exceeding 1.5 metre wide and not exceeding 1.5 metre deep for laying of cables etc, getting out and forming bottom surface to required gradient Complete all as specified and as directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers not exc 25cm each in hand / dense soil Complete all as specified and as directed.
Removing excavated material to a distance not exc 50m and depositing where directed at a level not exc 1.5m above the starting point in soils Complete all as specified and as directed.
Material and labour for riddled Sand Cushioning to cables a layer of 8 cm thick before laying the cable and second layer of 15 cm thick after laying the cable Complete all as specified and as directed. Note :- Sand shall be measured after punned down.
S & F sub class burnt Bricks for cable protection Complete all as specified and as directed
Material and Labour for G.I. tubing light grade of size 50mm bore for protection of cables to be laid under roads, crossings / culverts Complete all as specified and as directed.
Supply, laying,installing and testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 35 Sqmm 3½ core Complete all as specified and as directed.
Supply, fixing,installing and testing Factory fabricated, out door type cubicle panel board suitable for 3 phase 4 wire 415 V, 50 Hz having modern fabrication process powder coating in approved colour, provided with suitable gasket to make it dust/vermin proof The outer shell shall be made out of 3 mm thick CRCA sheet with front openable, double door system lockable/ open able. The bottom of the outer shell contains a detachable plate having size with glands. The degree of protection of outer shell shall be IP - 54. Inner shell shall be made out of 2.0 mm thick CRCA sheet duly compartmentalized for each control gear, TPN alluminum bus bar of rating not less than the 1.5 times the rated capacity of the incomer MCCB. The TPN bus bar shall be insulated with colour coded heat shrinkable sleave. All control wires shall be with 2.5 sqmm multi strand copper conductor and shall be propely bunched, tied, ferruled for proper identification and crimped with adequate size of lugs fixed on uitable size MS Channel frame all as specified and directed by Engr in charge. INCOMING (a) MCCB 100 A TPN 16ka - 01 No (b) Intelligent AC digital display three phase LCD ammeter 0 to 100 A and voltmeter 0 to 500V with CT (c) Indication lamp RYB/RRR-set of 03 -01 No OUTGOING (a) MCCB 3 pole 40 Amps 10 KA 415 Volt -3 No (b) Star delta starter submersible pump 10 HP including independent sensor system each pump - 2 No
Material and labour for PVC ceiling rose two to three terminals
Removing the incoming and out going cable connection, remove the earth strip from body and neutral point carefully from the existing DG sets 82.5 KVA and 15 KVA, Lifting the DG Set carefully by crane and kept aside for re installation.After PCC foundation reinstalled the both DG Set in PCC foundation care fully and reconnecting testing of DG set as directed at site
Excavation and removing the LT UG cable 120 sqmm 3½core loope in coming and out going of DG set 82.5 KVA, Supply and laying XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 120 Sqmm 3½ core
Excavation and removing the LT UG cable 50 sqmm 3½core loope in coming and out going of DG set 15 KVA , Supply and laying XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 50 Sqmm 3½ core Note : Earth work in excavation for item No 55 and 56 will be measured and paid extra under relevent item.
Material and Labour for Straight through joints (Epoxy) heat shrinkable type for UG cable including jointing kit and all accessories complete for making joints suitable for LT UG Cable of Aluminium conductor of size 50 to 95, Sqmm 3.5 / Complete all as specified and as directed.
Material and Labour for Straight through joints (Epoxy) heat shrinkable type for UG cable including jointing kit and all accessories complete for making joints suitable for LT UG Cable of Aluminium conductor of size 120 to 150 , Sqmm 3.5 Complete all as specified and as directed.
Material and labour for laying of GI strip 32 x 6mm size
Supply and fixing single phase monoblock pumpcapacity 1 HP with DOL starte and sensor controll
Earthing complete with galvanized iron or steel plate electrode 600 mm x 600 mm x 6.0 mm buried directly in ground vertically in pit of depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides with mixture of charcoal and common salt in alternate layers and electrode connected to GI earth earth strip 25 x 3 mm by means of GI bolts, nuts, check nuts and washers, earth wire protected by galvanized steel pipe 15 mm bore (light grade) connected to machinery/ equipment all as shown in Electrical plate No. 3 of SSR-2009 Part I and including necessary excavation and earth work in any type of soil, 20 mm bore light grade GI pipe for watering funnel wire mesh, PCC (1:3:6), type C-1 chamber, RCC (1:2:4), type B-1, reinforced with 6 mm dia MS round bars @ 15 cm c/c both way for cover and MS frame etc., Complete all as specified.
Supply and laying 4 Sqmm, 2 Core LT UG cable grade PVC XLPE insulated, PVC sheathed armoured, heavy duty, in trenches / walls / poles / passing through pipes with multistranded aluminium conductor including lugs / thimbles / ferrules connection, testing and commissioning Complete all as specified and as directed.
Supply and Fixing in repairs LED Tube light fitting 1 x20 W,220V CRCA housing with PC diffuser box type with driver,holder including LED tube light connecting up with 3 core 0.5sqmm copper wire between ceiling rose and fitting terminal all as specified and as directed.
Supply and fixing PVC regid conduit of size 20mm dia for stretching the G cable on Wall/ shelter all as specified and as directed.
Shanthi Construction
J R CONSTRUCTIONS
VSHVAS CIVIL AND ELECTRICAL SERVICES PRIVATE LIMITED
B5BUILDING SOLUTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .