Commandant ARC and MC
Assam Rifles Construction and Maintenance Company Laitkor Shillong
Repair maint of EandM eqpt AC Geyser Desert Cooler Fan DG Set Transformer Pump Set Panel RO at LOAR New Delhi
2021_ARMHA_624777_1
ENG/III-235/2020-21/40 dt 30 Mar 2021
Open Tender
Civil Works
Works
365 days
LOAR New Delhi
As per Tender Document
2 documents required · 2 mandatory
₹500
Yes
Commandant ARC and MC
Exempted
1 Jun 2021
30 Mar 2021
9 Apr 2021
30 Mar 2021
8 Apr 2021
30 Mar 2021
30 Mar 2021 - 8 Apr 2021
M&L for servicing to air conditioner split/window type of 1.5/2 ton capacity installed by disconnecting power connection and removing front PVC grills , filters cleaning washing with chemical copper condenser coil and cooling coil servicing cleaning fans including minor repair and replacement of grill filters where ever required with re assembling dismantled component to its original position with testing grill temperature to the optimum efficiency of machine to the entire satisfaction of Engr-in-Charge
Dismantling & taking down unserviceable sealed unit compressor from existing 1.5 ton split air conditioners of any make and replace the same by original manufacture / authorized dealer , 1.5 ton capacity sealed unit including necessary brazing and cleaning work and charging of refrigerant gas, including provision of new bushes, grommets, sleeves, washers , mounting rubbers , nuts bolts, terminal covers & clips, complete all as specified and directed with pressure testing complete to the entire satisfaction of Engr-in-charge.
M&L for refrigerant gas charging in split/window type air conditioner of any make/model as per desired pressure with minor repairs to copper tubing across including pressure testing for detection of leakages, vacuumsing etc complete to the entire satisfaction as directed by Engr-In-Charge.
M&L for replacement of capacitor of 3 mfd suitable for 1.5 ton capacity air conditioner including necessary connection with testing complete.
M&L for replacement of single phase out door unit fan motor 230 volt ,AC,50 Hz with copper bush including necessary power connection with testing complete.
Taking out the sample of transformer oil for checking the dielectric strength and acidity test of oil for the presence of moist presence of moisture, impurities etc after the dehydration including de-hydration (Filtration) of transformer oil through mobile filtration plant to be used to respective locations duly connecting inlet/outlet to the machine by switching off HT power supply and taking all safety precautions so as to achieve dielectric strength not less 36 to 40 KV per minute rupturing capacity and switch on supply, charging of transformer all as directed for transformer 200 KVA installed at LOAR Note for item no- 6 :-(a) Testing of transformer oil before & after dehydration shall be carried out as directed. (b) Oil required for topping up after dehydration and filtration shall be made available by contractor measured and paid against Sr. item No.8 (c) The rates are inclusive of transportation of mobile filtration plant from contractors workshop to each transformer and back.
Replacement of silica gel of 200 KVA in all complete
Supply, fill and topping up of transformer oil duly tested for proper de-electric strength up to desired level after heating up oil in each transformer all as directed
Replacement of LT busing complete with gasket set complete all as specified and as directed by the Engineer-In-Charge for 200 KVA transformer.
Replacement of LT busing Gun metal Rod complete with nuts bolts and washer complete all as specified and as directed by the Engineer-In-Charge
M & L maintenance and servicing of 125 KVA DG set (Make-Kirloskar) complete including draining out of diesel, draining out engine oil from the sump, flushing the sump and cleaning, replacement of gaskets, fuel filters, oil filters, air cleaner elements and the worn out parts like fuel flexible pipes, nuts, bolts, fuel line etc . filling the starting batteries with electrolyte, applying petroleum jelly in battery terminals poles, checking of voltage, amps, fuel, coolant and exhaust leakages etc including refilling radiator coolant , tightening all the nuts and bolts to the required torque incl testing in all respect as per directed by Engr-In-Charge.
M & L maintenance and servicing of 62.5 KVA DG set (Make-Kirloskar) complete including draining out of diesel, draining out engine oil from the sump, flushing the sump and cleaning, replacement of gaskets, fuel filters, oil filters, air cleaner elements and the worn out parts like fuel flexible pipes, nuts, bolts, fuel line etc . filling the starting batteries with electrolyte, applying petroleum jelly in battery terminals poles, checking of voltage, amps, fuel, coolant and exhaust leakages etc including refilling radiator coolant , tightening all the nuts and bolts to the required torque incl testing in all respect as per directed by Engr-In-Charge.
Replacement of engine oil, Kirloskar super 15W40 of DG sets where directed and as specified by; the manufacturers.
Supply only acid for Bty specified and directed
Supply only distrilled water for Btr specified and directed
Decoupling pump & motor, opening the body of motor, taking out burnt/defective winding wire carefully without damaging the stator, cleaning the slot, rewinding the stator with super enameled copper winding wire of existing gauge along with insulating material, greasing varnishing the bearing complete all as specified and as directed for 5 HP capacity of motor
Taking out old unserviceable starter of any type and supply and fixing of starter automatic star delta 415 volt 3 phase make Havells /L&T suitable for 5 HP motor pump set in all complete
Replacement of unserviceable fan motor with blade 1/32 Horse Power capacity suitable for water coolers 40/80 Ltr, complete all as specified and directed , Make:- AUE/Crompton
Taking out carefully old unserviceable sealed unit of make Shri Ram/ Kriloskar/Techumesh Model SR-412,4440/2612/CAJ 34 Compressor from water cooler 40/80 Ltr Capacity and replaced with factory reconditioned sealed unit from manufacture / authorized dealer of same model , after replacing the liquid line filter including oil and gas charging and necessary brazing work flushing cooling and condenser coil with CCI-4 solution including testing on pressure complete all as specified and directed
Supply and charging of refrigerant gas including detection of leakage, welding, brazing to stop leakage vacuum test , pressure test , complete all as specified and directed
Replacement of unserviceable overload protector complete all as specified and directed, Make:- Tecumesh/ Renutral/shriram/Indfoss
Replacement of unserviceable starting kit comprising of relay and overload protector for water cooler 40/80 Ltr Cap, Type of Compressor SR-412 including disconnecting of old staring kit , complete all as specified and directed, make:- Shriram /indfoss /Renutral
Replacement of unserviceable existing starting capacitor 40/60 Mfd capacity suitable for water cooler 40/80 Ltr Cap, complete all as specified and directed, Make:- Syscap/ Telsa/ Unistar/ Siemens/ Epcos
M&L for servicing of dessert cooler including replace of natural grass cleaner , water pipe, switches, regular if required, cleaning of water storage tank removing of old water and refilling fresh water and testing in all complete.
Replacement of unserviceable fan motor with blade suitable for dessert cooler complete all as specified and directed , Make:- AUE/ Havells / Crompton or equivalent
Replace of water pump suitable for dessert cooler incl testing in all complete
Disconnecting and taking down the complete ceiling fan with down rod from ceiling hook/Fan box any size /make/sweep at any location for carrying out overhauling such as cleaning ,oiling, lubricating, greasing etc and re fixing the ceiling fan back on the same location & connecting it properly and complete all as specified and directed. Note : Any worn out/ Defective parts required to be replaced will be measured and paid for separately under relevant item.
Replacement of MS clamp (set of two nos) with nut, bolts and washer, rubber reel, safety pin, complete all as specified and directed.
Replacement of (Bearing No - 6201,6202,6203 ) Ball bearing for 1200/1400 mm sweep ceiling fan of any model complete all as specified and directed. Make: NBC/SKF/HRC.
Replacement of existing unserviceable bush with new gun metal bush for any sweep/size/model of ceiling fan complete all as specified and directed
Replacement of capacitor 2.5 Mfd for ceiling fan of any make/model/sweep, complete. Make:- EPCOS/ NICCO/ USHA/ UNISTAR.
Rewinding the ceiling fan motor of 1200 mm sweep, with super enameled copper wire of appropriate gauge inc replacement of insulating materials such as laminated elytroid paper, sleeves, necessary varnishing with golden colour varnishing, greasing/oiling of bush and the bearing, replacement of missing/worn out nut, bolt& washer etc and lesting after reassembling the same complete all as specified and directed.
Rewinding the ceiling fan motor of 1400 mm sweep, with super enameled copper wire of appropriate guage inc replacement of insulating materials such as laminated lethroid paper, sleeves, necessary varnishing with golden colour varnishing , greasing/oiling of bush and the bearing, replacement of missing/worn out nut,bolt &washer etc and lesting after reassembling the same complete all as specified and directed. Make : For item No 7&8, Wire : Devi Dayal / HTP Ltd Bombay / Victor, Varnish : MODI / CHINAR / LOTUS. NOTE : For item No 7&8 : quoted rate of above item is inclusive of disconnection and taking down ceiling fan, rod blade set of three and opening out the ceiling fan for rewinding.
Replacement of PVC canopy of appropriate size suitable, or existing / new down rod complete.
Rewinding the Exhaust fan motor of 300 mm sweep motor by dismantling from frame with super enameled copper wire of appropriate guage inc replacement of insulating materials such as laminated lethroid paper, sleeves, necessary varnishing with golden colour varnishing, greasing/oiling of bush and the bearing, replacement of missing/worn out nut,bolt & washer split pin etc and testing after reassembling the same complete all as specified and directed for the following size. Make : Devi Dayal / HTP Ltd Bombey / Victor. Varnish : MODI / CHINAR / LOTUS.
Taking down the Geyser of capacity 25/35 / 50 Ltr including disconnecting of electric / water supply connections from building for repair / replacement of defective components and overhauling / checking, servicing, des calling of inner tank, geyser element, checking of geyser assembly and setting of thermostat range complete and refixing the same after repair and testing including making electectric and water supply connection complete all as specified and directed. Note:- a) All safety precautions for the safety precautions for persons working during removal/fixing back of the Geyser shall be ensured by the contractor . Rates are inclusive of brazing of inner tank of copper for prevention of leakage and replacement of clamps nut bolts gasket set complete. Replacement of defective components, painting, etc., which shall be measured and paid for separately.
Supply and Fixing Heating element of capacity 1.50 KW (any type), ISI marked, suitable for geyser of capacity 25Ltr complete all as specified and directed.
Supply and Fixing Heating element of capacity 1.50 KW (any type), ISI marked, suitable for geyser of capacity 35 Ltr complete all as specified and directed.
Supply and Fixing of Heating element of capacity 2 kW (cup type / triangular / threaded type), ISI marked, suitable for geyser of capacity 50Ltr complete all as specified and directed.
Replacement of neon Indicator lamp of red and green colour lamps suitable for geyser of capacity 25/35/ 50 Ltr of any type / make complete all as specified and directed
Replacement of Thermostat assembly 16 A,240 AC, ISI marked, suitable for geyser of capacity 25/35/ 50Ltr of any type / make complete all as specified and directed. Make:- Ditz / Universal /TTE/RACOLD
Replacement of PVC Helical (Hot / Cold) water connection pipe of size 450 mm x 15mm dia with two no of brass nut on each side for geyser complete all as specified and directed
Replace of MCCB 200 A, 4 pole, 415 volts (Make- L&T/Havells)
Replace of MCCB 100 A, 4 pole, 415 volts (Make- L&T/Havells)
Replace of on load change over switch 4 pole, 415 votls, 300 A
Repair/maint of RO Plant capacity 1000 ltrs including servicing and repair & maint of membrane, replacement pre and secondary filter , filter media and connecting accessories if required, rewinding of motor if required, Chemicals required for one year for smooth functioning of Plant etc.
RS constructions
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .