Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹6.8 LAccepted-AOC 193 E SHANTI PALLI PUSHPAHAR CO OPERATIVE KOLKATA 700107 | KOLKATA | WEST BENGAL | 700107 | L-1 | Accepted-AOC BEING L1 BID | |
| 2 | L-2₹7.3 L+₹24,689.60 (3.53%)Rejected-Finance 1 9 | PRAYAGRAJ | UTTAR PRADESH | 211001 | L-2 | Rejected-Finance Being L 2 | |
| 3 | L-3₹9.0 L+₹2.0 L (28.5%)Rejected-Finance | L-3 | Rejected-Finance Being L 3 |
Tender Value
₹10 L
EMD Value
₹50,000
Closing Date
29 Jul 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (I) (CGN) KOLKATA
GE (I) (Coast Guard Navy) Military Engineer Services Damodar Complex Naval Transit Accommodation Hastings, Kolkata700 023
REPAIR AND MAINTENANCE TO INTERNAL FITTINGS AND FIXTURES ALONG WITH REPAIR AND SERVICING TO ACS GEYSER AND CONNECTED WORK IN MD AND OTM ACCN AT CGRA MANICKTALA UNDER GE (I) (CGN) KOLKATA
2023_MES_607065_1
NIT No 8701/26/2023-2024/03/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
CGRA MANICKTALA
AS PER TENDER DOCUMENT
8 documents required · 8 mandatory
₹500
GE (I) (CGN) Kolkata
₹50,000
Yes
12 Aug 2023
30 Jun 2023
31 Jul 2023
30 Jun 2023
29 Jul 2023
15 Jul 2023
Amount
Taking down carefully copper/ aluminium point wiring (light, fan, socket or power) complete, (including unscrewing from boards/out-let boxes, fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, brackets, ceiling fittings, bulk head fittings, tube light fittings and regulators, etc.), removing materials off the site of work and making good disturbed surfaces of walls, floors, etc. complete all as specified and as directed.
Material and labour for concealed point wiring including necessary chase cutting of wall for one light/fan/call bell point with 1.5 sqmm PVC insulated (FR-LSH) unsheathed copper cable multistranded conductor 1100 volts grade controlled by one way switch including 1.5 sqmm PVC (FR-LSH) insulated unsheathed copper cable multistrand conductor 1100 volts grade for continuity earth wire connected to common earth dolly drawn through and including PVC conduit and making good the distrubed surfaces as per the existing complete all as specified and as directed. Note: A. Red coloured cable shall be used for live connection, black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board. B. The Rate of point wiring includes the following :- (i) Copper wire (ii) PVC Conduit with accessoreis (iii) Chase cutting and making the good to disturbed surface.
All as per item No 2 above but for one light point controlled by two 2-way switches complete all as specified and directed.
All as per item No 2 above but for one three pin socket outlet on same board all complete all as specified and directed.
All as per item No 2 above but for one three pin socket out let 5 amps on independent board complete all as specified and directed.
Material and labour in repairs for sub-main wiring with PVC insulated & unsheathed two run of 4 Sqmm single core multi stranded copper conductor cable (FRLSH), 1100 Volt grade alongwith one run of 4 Sqmm PVC insulated & unsheathed copper conductor cable (FRLSH), 1100 Volt grade, connected to common earth dolly as earth continuity conductor, drawn through 20 mm conduit with all accessories and PVC rectangular boxes for mounting switch socket and fan regulator etc complete all as specified and as directed. Note :- (i) One run of PVC conduit, two runs of cable (Phase + Neutral) and one run of earth wire shall be measured and paid as one unit. (ii) Quoted rate shall deemed to be incluive of chase cutting, laying of conduit and making good the surface as per existing.
Material and labour in repairs for sub-main wiring with PVC insulated & unsheathed two run of 2.5 Sqmm single core multi stranded copper conductor cable (FRLSH), 1100 Volt grade alongwith one run of 2.5 Sqmm PVC insulated & unsheathed copper conductor cable (FRLSH), 1100 Volt grade, connected to common earth dolly as earth continuity conductor, drawn through suitable size PVC casing-caping with all accessories and PVC rectangular boxes for mounting switch socket and fan regulator etc complete all as specified and as directed. Note :- (i) One run of PVC casing-caping, two runs of cable (Phase + Neutral) and one run of earth wire shall be measured and paid as one unit. (ii) Quoted rate shall deemed to be incluive of chase cutting, laying of conduit and making good the surface as per existing.
Supply and fixed in repairs switch piano flush type single pole one way 5A SP 230 Volts complete all as specified and as directed.
Supply and fixed in repairs switch piano 5A SP 230 Volts 2 way complete all as specified and as directed.
Supply and fixed in repairs ceiling rose PVC surface type 3 terminals complete all as specified and as directed.
Supply and fixed in repairs fan regulator electronic stepped type, 230 volts complete all as specified and as directed.
Supply and fixed in repairs lamp holder PVC/ Polycarbonate type complete all as specified and as directed.
Supply and fixed in repairs call bell, multi music type and connection complete all as specified and as directed.
Supply and fixed in repairs bell push switch piano flush type 5 Amp SP one way complete all as specified and as directed.
Supply and fixed in repairs 6 Amps one way single pole flush type piano switch modular type complete all as specified and as directed.
Supply and fixed in repairs 6 Amps two way single pole flush type piano switch modular type complete all as specified and as directed.
Supply and fixed in repairs bell push for calling bell 5 amps flush modular type complete all as specified and as directed.
Supply and fixed in repairs fan regulator step type electronic flush 2 modular type complete all as specified and as directed.
Supply and fixed in repairs modular metal box 1 way complete all as specified and as directed.
Supply and fixed in repairs modular metal box 2 way complete all as specified and as directed.
Supply and fixed in repairs modular metal box 3 way complete all as specified and as directed.
Supply and fixed in repairs modular metal box 4 way complete all as specified and as directed.
Supply and fixed in repairs modular metal box 6 way complete all as specified and as directed.
Supply and fixed in repairs modular metal box 8 way complete all as specified and as directed.
Supply and fixed in repairs modular white cover plate with frame 1 way complete all as specified and as directed.
Supply and fixed in repairs modular white cover plate with frame 2 way complete all as specified and as directed.
Supply and fixed in repairs modular white cover plate with frame 3 way complete all as specified and as directed.
Supply and fixed in repairs modular white cover plate with frame 4 way complete all as specified and as directed.
Supply and fixed in repairs modular white cover plate with frame 6 way complete all as specified and as directed.
Supply and fixed in repairs modular white cover plate with frame 8 way complete all as specified and as directed.
Supply and fixed in repairs switch socket combination outlet 2 in 1 3/5 pin 5 and 15 Amps flush type complete all as specified and as directed.
Supply and fixed in repairs switch Socket combination outlet 2 in 1 3 pin 5 Amps Flush type complete all as specified and as directed.
Supply and fixed in repairs socket outlet 2 in 1, 2/3 pin, 5 Amps Flush type complete all as specified and as directed.
Supply and fixed in repairs switch socket combination 6/16 Amps 5 in one flush modular type complete all as specified and as directed.
Supply and fixed in repairs socket outlet 3 pin 6 A flush modular type complete all as specified and as directed.
Supply and fixed in repairs power unit 6 module flush type with starter, DP MCB & Plug top with indicator complete all as specified and as directed.
Supply and fixed in repairs LED Bulb type 12 Watt in warm white/ natural white complete all as specified and as directed.
Supply and fixed in repairs LED tube light fittings 20 W made of epoxy powder coated white extruded aluminium channel, operational voltage of 140 volts to 270 volts, frequency of 50 Hz,lumen efficacy of minimum 110 lumens per watt, integral electronic LED driver (SMPS based constant current supply) with output short circuit protection, over voltage protection, surge voltage protection upto 2 KVs, CRI greater than 80%, CW available CCT of 6500K, power factor of minimum 0.95, life span of minimum 50000 working hours complete all as specified and as directed.
Supply and fixed in repairs LED tube light fittings nominal power 10 Watt LED , LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen efficacy of minimum 110 lumens per watt, integrated electronic driver (SMP based constant current supply) with output short circuit protection and surge protection upto 2 KV, protection grade IP 20, CRI greater than 80%, beam angle of 120⁰ clear, THD below or less than 15%, CW available CCT of 6500K, power factor of minimum 0.95, epoxy powder coated white extruded aluminium channel housing, life span of minimum 50000 working hours complete all as specified and as directed.
Supply and fixed in repairs LED recess/surface mounted, glare free uniform illumination with longer life and less maintenance, 15 W with minimum lumen capacity 110 Lum/W complete all as specified and as directed.
Supply and fixed in repairs LED recessed full open 2 ft x 2 ft tile, glare free uniform illumination with longer life and less maintenance, 24 W with minimum lumen capacity 110 Lum/W complete all as specified and as directed.
Supply and fixed in repairs LED street light 35 W made up of pressure die cast housing with IP 66 protection with system efficacy 110 lumen/W complete all as specified and as directed.
Supply and fixed in repairs LED bulkhead light fittings 10 W with system efficacy 110 lumen/W suitable for interior and exterior application all as specified and as directed.
Supply and fixed in repairs wall mounted decorative light with provision of LED lamp including lamp of 9 W warm white all as specified and as directed.
Material and labour for rewinding of ceiling fan of any make/model/sweep including removal of existing burnt winding carefully from slots, cleaning the slots throughly with suitable cleaning agent, applying slot insulation and rewinding with super enamelled copper conductor of same gauge/same number of turns as that of existing and connecting the coil suitable to operate on 230 V, single phase, AC supply, permanent capacitor type, tying the winding and applying air drying the winding throughly and all as specified and directed.
Supply and fixed in repairs ceiling fans, AC, 50 Hz, single phase, 230 V, 1200 mm sweep, minimum air delivery 200 m³ per minute, minimum service value 4 m³ per minute per watt, maximum power input 50 watt complete with three blade, down rod, accessories complete all as specified and as directed. Note : (i) The rate of materials used for scafolding works shall be deemed to be included in the quoted rate, materials also be arranged by the contractor and also shall be taken back safely by the workers employed by the contractor at his own risk. (ii) Unservicable fan deposited to MES store.
Material and labour for rewinding of exhaust fan of 250/300mm including removal of existing burnt winding carefully from slots, cleaning the slots throughly with suitable cleaning agent, applying slot insulation and rewinding with suer enamelled copper conductor of same gauge/same number of turns as that of existing and connecting the coil suitable to operate on 230 V, single phase, AC supply, permanent capacitor type, tying the winding and applying air drying the winding throughly and all as specified and directed.
Taking down ceiling fan of any make/model and sweep for ovehauling /servicing, cleaning and lubricating movable parts with suitable lubricating oil/grease and refixing at site and connection complete from ceiling rose to connector with new flexible cord of suitable size, testing after completion of the work all as specified and as directed. Note : The accessories such as bearing and capacitor will be measured and paid seperately under relevent item.
Supply only capacitor 2.5 mfd suitable for ceiling fan of any make/model and sweep all as specified and as directed .
Supply only Ball bearing No 6201 suitable for ceiling fan of 1200 mm sweep all as specified and as directed .
Supply only Ball bearing No 6202/6203 suitable for ceiling fan of 1200mm sweep all as specified and as directed .
Material and labour for Painting of ceiling fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc. and refixing at site at same/ different location all as specified and as directed .
Taking down exhaust fan of any make/ model and sweep for ovehauling/ servicing, cleaning and lubricating movable parts with suitable lubricating oil/grease and refixing at site at same/different location and connection complete from ceiling rose to connector with new flexible chord of copper of suitable size, testing commissioning after completion of the work. Note : The accessories such as bearing and capacitor will be measured as supply only.
Supply only capacitor 2.5 MFD 230 Volt suitable for exhaust fan of any make/model and sweep all as specified and as directed .
Supply only Ball bearing suitable for exhaust fan of any sweep all as specified and as directed .
Material and labour for painting to exhaust fan complete with one coat of synthetic enamel paint of approved quality and colour by using spray after preparing the surface throughly and refixing at site at same/different location all as specified and as directed .
Supply and fixed in repairs louver for exhaust fan of existing type all as specified and as directed.
Supply and fixed in repairs exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300mm complete all as specified and as directed. Note : (i) The rate of materials used for scafolding works shall be deemed to be included in the quoted rate, materials also be arranged by the contractor and also shall be taken back safely by the workers employed by the contractor at his own risk. (ii) Unservicable fan deposited to MES store.
Supply and fixed in repairs exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers complete all as specified and as directed. Note : (i) The rate of materials used for scafolding works shall be deemed to be included in the quoted rate, materials also be arranged by the contractor and also shall be taken back safely by the workers employed by the contractor at his own risk. (ii) Unservicable fan deposited to MES store.
Material and labour in repairs for MCB FP 'B' series 4-100 Amps complete all as specified and as directed.
Material and labour in repairs for MCB FP 'B' series 16-32 Amps complete all as specified and as directed.
Material and labour in repairs for MCB FP 'C' series 16-32 Amps complete all as specified and as directed.
Material and labour in repairs for MCB DP 'C' series 6-32 Amps complete all as specified and as directed.
Material and labour in repairs for MCB SP 'C' series 5-32 Amps complete all as specified and as directed.
Material and labour in repairs for sheet metal DB 12 way double door with 200 Amps rated bus bar triple pole with neutral complete all as specified and as directed.
Material and labour in repairs for sheet metal DB 8 way double door with 200 Amps rated bus bar Single pole with neutral complete all as specified and as directed.
Material and labour in repairs for sheet metal DB 4 way double door with 200 Amps rated bus bar Single pole with neutral complete all as specified and as directed.
Material and labour in repairs for blank plate of suitable in lieu of MCB to be fixed in DB complete all as specified and as directed.
Material and labour in repairs for MCCB 4 pole of 200 Amp capacity, 25 KA with sheet metal enclosure all as specified and as directed.
Material and labour in repairs for PVC Pole/ Junction box of existing size with suitable size of cable connector and provision of fitting for MCB all complete all as specified and as directed.
Material and labour in repairs for heating element 1000-2000 Watt ISI marked for gyser as per existing size with all connecting accessories complete all as specified and as directed.
Material and labour in repairs for thermostat switch of geyser 230V, 30 degree to 90 degree centigrade temp range to be set at 70 degree to 50 degree centigrade suitable for water heater complete all as specified and as directed
Material and labour in repairs for connecting pipe set for geyser of best quality of suitable size and length complete all as specified and directed.
Material and labour in repairs for air release valve 15 mm dia for geyser including all as specified and directed.
Taking down water heater (geyser) 25 ltrs capacity for servicing and scraping, cleaning including brazing of inner vessel of the geyser at leakage point to made it leak proof including testing pressure and assembling of all component refixing complete including supply and fixing of minor spare parts all as specified and as directed.
Material and labour in repairs for electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc all as specified and as directed.
Material and labour in repairs for for PVC insulated unsheathed three core flexible copper cable of size 2.5 sq mm complete all as specified and as directed
Supply and fixed in repairs 15 Amp plug top for geyser/AC all as specified and as directed.
Supply and fixed in repairs copper inner shell of electric geyser of cap 25 ltr 2 mm thick sheet all as specified and as directed.
Material and labour for servicing of Split /window type AC unit of capacity 1.5/2.0 TR that includes cleaning of air filters, indoor un it grilss & filters through air blower, cleaning of indoor unit body by wiping out dust etc. with wet cloth, cleaning of blower and condensor fan, cleaning of evaporator & condenser coils, graseing/oiling of motors and all moving marts and checking various parts of AC for proper functioning. Note: (i) All major parts or spares as mentioned below will be measured separately. (ii) Charging of gas to be measured separately. (iii) Rate of all minor spares deemed included in the rate.
Supply only R-134A / R-410A refrigerant gas complete all as specified and as directed.
Supply and fixed in repairs hermeatically sealed unit of compressor for AC of 1.5/2.0 TR capacity including charging gas R-134A/ R-410A complete all as specified and as directed.
Supply and fixed in repairs electronic circuit board as existing type for 1.5 TR/2.0 TR capacity split type AC complete all as specified and as directed.
Supply and fixed in repairs display board as existing type for 1.5 TR / 2.0 TR capacity Split / window type AC complete all as specified and as directed.
Supply and fixed in repairs capacitor combined type 50 MFD capacity for 1.5 TR / 2.0 TR split/window type AC complete including taking down all as specified and as directed.
Supply and fixed in repairs running capacitor for 1.5 TR/2.0 TR window/ split type AC as per existing type complete all as specified and as directed.
Supply and fixed in repairs starting capacitor for 1.5 TR/2.0 TR window/ split type AC as per existing type complete all as specified and as directed.
Supply and fixed in repairs capilary tube copper 1.5 TR/2.0 TR window/ split type AC as per existing type complete all as specified and as directed.
Supply and fixed in repairs electrical terminal for outer unit PVC/polycarbonate all as specified and as directed.
Supply and fixed in repairs blower fan motor for indoor unit 1.5 TR/2.0 TR window/ split type AC as per existing type complete all as specified and as directed.
Supply and fixed in repairs outer fan motor for outdoor unit 1.5 TR/2.0 TR window/ split type AC as per existing type complete all as specified and as directed.
Supply and fixed in repairs swing motor for indoor unit 1.5 TR/2.0 TR window/ split type AC as per existing type complete all as specified and as directed.
Supply and fixed in repairs 3 core copper cable 4.0 sqmm for connection outer to inner unit of split type AC complete all as specified and as directed
Supply and fixed in repairs copper tube 3/8" size thickness 0.7mm for connection to outer to inner unit for 1.5 TR / 2.0 TR capacity split type AC complete all as specified and as directed.
S & F copper tube 5/8" size thickness 0.7mm for connection to outer to inner unit for 1.5 TR / 2.0 TR capacity split type AC including taking down complete all as specified and as directed.
Supply and fixed in repairs insulation cover for thermally insulated copper tube for 1.5 TR / 2.0 TR capacity complete all as specified and directed
Supply and fixed in repairs medium grade PVC Conduit for drain water of size 15 mm dia complete all as specified and as directed.
Supply and fixed in repairs fan blade existing type for window / split type AC including all as specified and as directed.
Supply only remote for spilit/window type AC as per site/ordered model complete all as specified and as directed by Engr-in-Charge.
Material and labour for servicing of deep freezer of 500 LPD capacity any make/model including repair/replacement of spares with proper cleaning of water storage space, cooling coil, charging of refrigerent etc for proper functioning complete all as specified and as directed.
Material and labour for aepair/maint electronic meters class 1 base mounted, single/three phase 5-40 A rating including repair/replacement of all unserviceable parts and reinstalled the same complete all as specified and as directed.
Supply and fixed in repairs single phase KWh meter with LCD display, 5-40A with box, including connection wire and grouting of nut, bolts, complete all as specified and directed.
Material and laabour for servicing of solar water heater 500 LPD as per exisiting capacity including repair/replacement of connecting pipe and valve as per existing, solar collector etc with proper cleaning of storage tank, connecting accessories and fitted properly complete all as specified and as directed. Note: Cost of spares for repair if any deemed inclusive of the quoted rate.
Material and labour for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 4.0 mm dia galvanised mild steel wire by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 20 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed by the Engineer-in-charge.
Material and labour in repairs for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/ pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 25x4 mm galvanised iron strip complete incl saddles if required complete all as specified and as directed.
Material and labour in repairs test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw all as specified and as directed.
Material and labour in repairs for Air termination, single pointed aluminium rod 12mm dia and 300mm long all as specified and as directed.
Material and labour refixing of hanging/ loosen earth strip/ roof conductors of Cu/ GI/ Al with replacement of broken/ missing porcelain conductor space as per direction of Engr-in-charge with help of proper clamping, saddling and connected accessories at the original location complete all as directed.
Material and labour refixing of hanging/loosen earth strip/down conductors of Cu/GI/Al with replacement of broken/missing porcelain conductor space as per direction of Engr-in-charge with help of proper clamping, saddling and connected accessories at the original location complete all as directed.
K.P Construction Co
TAMALIKA ENTERPRISE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .