Tan Delta and Partial Discharge testing of various CT/ Bushings at various 220/132 KV Substations under Electy. Trans. Circle-I, Prayagraj
2024_UPTCL_962310_1
22-ETC-I(A)/ 2024-2025
Open Tender
Miscellaneous Works
Item Rate
60 days
Prayagraj
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
SE,ETC,PRAYAGRAJ
₹10,000
3 Jun 2025
3 Oct 2024
11 Oct 2024
3 Oct 2024
10 Oct 2024
3 Oct 2024
Amount
Tan Delta and Partial Discharge testing of various CT/ Bushings at various 220/132 KV Substations under Electy. Trans. Circle-I, Prayagraj.
Following testing works are to be conducted for health monitring of various current Transformers in 132 KV bays as per technical specifications at various 220/132 KV Substations under ETD-I, Prayagraj
Partial Discharge Test of various 132 KV Current Transformers Partial Discharge test by both EHF (Extra High Frequency) and HF (High Frequency) methods with the help of reputed make, high accuracy & duly calibrated Test Kits. The work also includes the cost of carriage and operation of Test kit including preparation and submission of test results in specified formats ater the completion of tests. The test results should clearly mention the Health of ETs and suggestion for Action Taken regarding the same.
132 KV Current Transformers of various 132 KV Feeder/Transformer Bay 1. 132 KV Soraon - 12 2. 132 KV Jhusi - 21 3. 220 KV Phulpur - 18 4. 132 KV Handia - 11 5. 132 KV Saidabad - 09 6. 132 KV Kaudihar - 15 7. 132 KV Gyanpur - 06
Capacitance and Tan Delta Measurement & IR value Tan dalta test of 132 KV CTs/bushing of 220/132 KV T/Fs with the help of reputed make high accuracy & duly calibrated Test Kits to be arranged by the contractor including the cost of carriage and operation of Test kit including preparation and submission of test results in specified formats after the completion of tests. The tests shall include capacitance, Tan Delta value measurements (Recent calibration cerficate to be submitted by the contractor before the test). The works shall include the cost of carriage of Test Kit. Manpower involved in testing and submission of test reports in specified formats.
132 KV CTs/220/132 KV Bushings of Power Transformer.
Following testing works are to be conducted for health monitring of various current Transformers in 132 KV bays as per technical specifications at various 220/132 KV Substations under ETD-Fatehpur
Partial Discharge Test of various 132 KV Current Transformers Partial Discharge test by both EHF (Extra High Frequency) and HF (High Frequency) methods with the help of reputed make, high accuracy & duly calibrated Test Kits. The work also includes the cost of carriage and operation of Test kit including preparation and submission of test results in specified formats ater the completion of tests. The test results should clearly mention the Health of ETs and suggestion for Action Taken regarding the same.
132 KV Current Transformers of various 132 KV Feeder/Transformer Bay 1. 132 KV Malwan - 08 2. 132 KV Bindki - 12 3. 220 KV Fatehpur - 06 4. 132 KV Khaga - 07 5. 132 KV Jahanabad - 08
Capacitance and Tan Delta Measurement Tan dalta test of 132 KV CTs/bushing of 220/132 KV T/Fs with the help of reputed make high accuracy & duly calibrated Test Kits to be arranged by the contractor including the cost of carriage and operation of Test kit including preparation and submission of test results in specified formats after the completion of tests. The tests shall include capacitance, Tan Delta value measurements (Recent calibration cerficate to be submitted by the contractor before the test). The works shall include the cost of carriage of Test Kit. Manpower involved in testing and submission of test reports in specified formats.
132 KV CTs/220/132 KV Bushings of Power Transformer.
Following testing works are to be conducted for health monitring of various current Transformers in 132 KV bays as per technical specifications at various 220/132 KV Substations under ETD-Pratapgarh
Partial Discharge Test of various 132 KV Current Transformers Partial Discharge test by both EHF (Extra High Frequency) and HF (High Frequency) methods with the help of reputed make, high accuracy & duly calibrated Test Kits. The work also includes the cost of carriage and operation of Test kit including preparation and submission of test results in specified formats ater the completion of tests. The test results should clearly mention the Health of ETs and suggestion for Action Taken regarding the same.
132 KV Current Transformers of various 132 KV Feeder/Transformer Bay 1. 132 KV Pratapgarh - 06 2. 132 KV Kunda - 13 3. 220 KV Lalganj- 15 4. 132 KV Patti - 07=6 5. 132 KV Gadwara - 09 6. 220 KV Pratapgarh - 15
Capacitance and Tan Delta Measurement Tan dalta test of 132 KV CTs/bushing of 220/132 KV T/Fs with the help of reputed make high accuracy & duly calibrated Test Kits to be arranged by the contractor including the cost of carriage and operation of Test kit including preparation and submission of test results in specified formats after the completion of tests. The tests shall include capacitance, Tan Delta value measurements (Recent calibration cerficate to be submitted by the contractor before the test). The works shall include the cost of carriage of Test Kit. Manpower involved in testing and submission of test reports in specified formats.
132 KV CTs/220/132 KV Bushings of Power Transformer.
MAYANK ELECTRICAL WORK
M/S KARAN SUPER ELECTRICAL WORKS
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .