Garrison Engineer M AF Jalahalli
Garrison Engineer M AF Jalahalli Bangalore 560013
UPKEEP MAINT OF WATER SUPPLY INSTALLATION REPAIR MAINT OF EXTERNAL ELECTRICAL DISTRIBUTION SYSTEM VARIOUS EARTHING INFRASTRUCTURE AND OTHER E M WORKS AT AFS JALAHALLI
2024_MES_638559_1
8872/E8
Open Tender
Civil Works
Item Rate
181 days
Garrison Engineer M AF Jalahalli
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE AF MAINT JALAHALLI PUBLIC FUND ACCOUNT
₹1 L
27 Jun 2024
23 Jan 2024
28 Feb 2024
23 Jan 2024
26 Feb 2024
6 Feb 2024
24 Jan 2024 - 30 Jan 2024
Amount
Taking down chowkhat or frame(wooden/steel) exceeding 1.50 Sqm not exceeding 4.0 Sqm each with shutter (with out taking off shutters from the frame) all as specified and as directed.
Taking down chowkhat or frame(wooden/steel/Alumnium) not exceeding 1.5 Sqm each with shutter (with out taking off shutters from the frame) all as specified and as directed.
Taking down shutters of any description n.exc 2.0 Sq.m each complete all as specified and directed.
Cutting holes in stone wall exc half brick and n.exc one brick in cement mortar for inserting hold fasts/lugs and making good dismantled portion in cement mortar 1:3 or 1:2:4 type B-1 concrete as required complete all as specified and as directed.
Supply and fixing MS work (flat iron) 25mm x 3mm thick) in small articles such as hold fast and similar smaal articles conforming to Fe 290 Gde E-165 including dismantling existing MS work etc complete all as specified and directed.
Material and labour for Second class hard wood plain, solid, straight Chowkats and frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and directed.
Supply and fixing 2nd class hard wood 35mm thick Factory made plain framed panelled shutter any number of panels of with lock rail and panel of 9mm BWP commercial ply or 12mm veneered partical board with commercial veneering on both faces. The size of rail and stile as per IS 1003 (Part-I), kiln seasoned and chemically pressure treated etc complete all as specified and directed.
Supply and fixing Factory made 35mm thick Glazed and skeleton door shutters, open rebated and prepared to receive glass, gauze, etc. divided into squares, with plain, chamfered or rounded, mitred and rebated sash bars, any numbers, edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); etc complete all as specified and directed.
Supply and fixing Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS Square tube etc complete all as specified and directed.
Supply and fixing Factory made Solid PVC Door Shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail. Panelling of plain colour PVC sheet to be fitted in the MS frame welded / sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement etc complete all as specified and directed.
Preparation of new wood or wooden based surfaces of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed
Material and labour for Preparation of old painted wooden surface of any description and applying one coats of synthetic enamel paint using mechanical means, not otherwise described over 10 cm width or girth, complete all as specified and directed.
Supply and fixing Butt hinges 75 mm long medium weight cold rolled stainless steel complete all as specified and as directed.
Supply and fixing in repair 00mm long Butt hinges medium weight cold rolled stainless steel, fixed in repair to wooden frame/welded to metal frame complete all as specified and as directed.
Supply and fixing 100mm long Butt hinges medium weight cold rolled stainless steel, and fixed complete all as specified and as directed.
Supply and fixing 150 mm long aluminum anodized barrel tower bolt extruded section complete all as specified and as directed.
Supply and fixing 200 mm long aluminum anodized barrel tower bolt extruded section complete all as specified and as directed.
Supply and fixing aluminum handles cast type anodized 150 mm long complete all as specified and as directed.
Supply and fixing Aluminum handles cast type anodised 200 mm long complete all as specified and as directed.
Supply and fixing 250mm Aluminium alloy, anodised, sliding door bolts with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extrudud sections or cast- aluminum alloy and fixed complete all as specified and as directed.
Supply and fixing Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.4mm complete all as specified and directed.
Supply and fixing 5mm thick rubber beading strips of entrance doors having width exc 3 cm but not exc 5cm to arrest entry of insects including taking down existing beading complete all as specified and as directed
Supply and fixing in repair Floor door stopper of aluminium alloy body and tongue anodized with hard drawn steel spring fixed in floor overall 140mm etc complete all as specified and as directed.
Supply and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) frame work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ panelling, C.P. brass/ stainless steel screws,included rubber beading all complete as per architectural drawings etc complete all as specified and as directed.
Supply and fixing in powder coated aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodisedaluminium fittings such as peg stays150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ panelling, C.P. brass/ stainless steel screws, star lock, included rubber beading all complete as per architectural drawings etc complete all as specified and as directed.
Supply and fixing in repair aluminium anodised grill (anodised transparent or dyed to required shade according to IS:1868 with minimum anodic coating of grade AC15) of approved design/pattern(DG 104), with approved standard section and fixed to existing window frame with CP brass/stainles steel screwnot less than 50mm and @ 200mm c/c, incl cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised alu standard section ( 28mm x 19mm x 2mm thick)around the opening, all complete as per requirement etc complete all as specified and as directed.
Supply and fixing in repairs12mm thick Pre-laminated particle board, exterior grade, prelaminated on one side with decorative choice lamination and other side balancing white lamination including fixing of teak wood beading on open edges in any position such as cup boards, kitchen cupboards, Rack, drawers shutters and all other fittings, knob, hinges,beading, magnetic catch etc. fixed with screws to timber frame work etc complete all as specified and directed.
Supply and fixing in repair 2nd class hardwood Plain fillets, square, rectangular or triangular in section, clean sawn, secured with nails or brads in section area not exc 13 sq cm complete all as specified and as directed.
Material and labour for Petty repairs to MS window shutters n. exe 2 sqm each through cutting of existing any type of hinges, handle and tower bolt and fixing new box type hinges, MS handle and MS tower bolt to the same window by welding and with minor repair and easling and adjustment/aligment to openable assessories if requred any ( like butt hinges, handle, tower bolt, handle, peg stay etc complete ) and replacement of window glass hacking out old putty or removing beads etc, and reputtying all glass and painting/oiling puttied surface to match existing work and included taking down and refixing complete all as directed. Note:-(i) The unit quoted rate shall be inclusive of material,any helght of any size and all labours, tools and plants including scaffolding, safety helmet, rope required for working upto approx 15 mtr height from natural ground level and nothing extra shall be admissible on this account.
Material and labour for PCC (1:4:8) type D2 using 40mm graded aggregate 75mm thick as in sub base of floor finished even and rough to receive top layer including demolition of cement Concrete (un reinforced) of any description and in any position not otherwise specifically provided etc all as specified and directed.
Material and labour for Non-skid Ceramic tiles 7-8 mm thick, area of each tiles exc 0.09 sqm not exceeding 0.16 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over 15 mm thick Cement Mortar 1:4 screed bed or bedding layer including dismantling of existing tile and removing rubbish off the premises complete all as specified and as directed.
Material and labour for Ceramic wall tiles 7-8 mm thick designed , of size 300 x 450 mm in walls etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over 10 mm thick backing coat in Cement Mortar 1:3 including dismantling of existing tile and removing rubbish off the premises complete all as specified and as directed.
Material and labour for Plain cement concrete (1:3:6) type C1 (20 mm graded stone aggregate), 75mm thick, as in plinth protection, top surface of concrete finished even and smooth with out using extra cement, including expansion joint 10mm thick filled with mastic filling comprising of 01 part of heated blown bitumen and 3 parts of sand including demolition of existing cement concrete and disposal of demolished material out side MD land complete all as specified and directed.
Material and labour for rendering 10mm thick in CM 1:6 on fair faces of brickwork or concrete surface as on wall finished even and smooth with thin layer and Taking down old cement plaster on brick or stone walls, or concrete walls etc., hacking for key, scrubbing down with water, etc., including removal of rubbish off the premises complete all as per specified and directed.
Material and labour for rendering 15mm thick on fair faces of brick/concrete surfaces with two coats i.e. (10mm thick backing coat in CM 1:6 and 5mm thick finishing coat in CM 1:4) and mixed with WPC, finished even and smooth without using extra cement (WPC to be measured and paid separately) and Taking down old cement plaster on brick or stone walls, or concrete walls etc., hacking for key, scrubbing down with water, etc., including removal of rubbish off the premises complete all as per specified and directed.
Supply only liquid water proofing Liquid
Material and labour for applying two coat of cement based paint over a coat of primer, including preparation of newly plastered wall surfaces of any description, complete all as specified and as directed.
Material and labour for Preparation of old decorated plastered or unplastered surface of wall, chajja,ceiling, balcony, facia etc., brooming down or steel wire brushing down smoke soot, moulds mass, efflorescent, trading, oil, greasy spots and applying one coat of cement base paint complete all as specified and directed.
Material and labour for preparation of new plastered surfaces of walls applying plaster of paris putty of 1 mm thickness over plastered surface to prepare the surface even and smooth and applying two finishing coat of oil bound distemper over a coat of primer complete all as specified and as directed.
Material and labour for Preparation of old decorated plastered or unplastered surface of wall, brooming down or steel wire brushing down smoke soot, moulds mass, efflorescent , trading, oil, greasy spots and applying one coat oil bound distemper complete all as specified and as directed.
Dismantling structural steel work incl doors, gates but excluding framed trusses etc complete all as specified and as directed.
Supply and fixing framed work as in doors or gates of angle,tubes or other section with gusset plates, rails, Plain sheet braces,guard bar etc., complete, to be prepared for hanging or sliding with and including hinges or steel hanging door fittings (exclusive of steel sheeting or other covering) and hanging; also fastening and fixing Fe 410 -W (Gde- E- 250) quality-A complete complete all as specified and as directed.
Supply and fixing MS Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S. 1161 -1979 grade St.-240 complete all as specified and as directed.
Material and labour for Preparation of old painted surfaces of steel and applying one coat of synthetic enamel paint using mechanical means over 10 cm width or girth, not other wise described complete all as specified and as directed.
Material and labour for Providing two coats of synthetic enamel paint over a coat of red oxide primer on steel surfaces over 10 cm width or girth including preparation of new steel surfaces and all as specified and directed.
Supply and fixing Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws & included dismantling of any type of sheets in roof coverings complete all as specified & directed
Supply and fixing Anodized alunimun size 605 x 605 mm snap grid frame work for false ceiling as per manufacturer instructions, with Hangers 6 mm dia. G.I. (up to 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long and 6mm thick Non asbestos fibre cement building boards, fixed to sheet suitably placed in false ceiling grid made of Aluminium/G.I./ M.S.as per pecification and drawing and including dismantling old unservicable wall celing board & frame with of any type and description, complete all as specified and directed.
Material and labour for 300x300x25mm thick prepolished cement concrete chequered tiles jointed in neat cement slurry and pointed in white or coloured cement to match the floor and including 20mm thick screed bed in CM 1.4 and incl removal of old unserviceable tiles and neccessary demolition and all as specified and directed.
Material and labour for kerb stone pre cast in PCC (1:2:4) type B1 using 20mm graded aggregate finished even and fair without using extra cement and all as specified and directed and Demolition of old kerb stone (un reinforced) of any description and in any position not otherwise specifically provided complete all as specified and as directed.
M & L Providing cement concrete in PCC coping 1:2:4 type B1 (20mm aggregate) and Demolition of Concrete (un reinforced) of any description and in any position not otherwise specifically provided of any description as specified and directed.
Supplying and laying of 20mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors including taking out steel/plastic/cpvc water tubing and connections for cleaning or refixing 15 mm/20mm dia complete all as specified and as directed.
Supplying and fixing in repairs of 20mm outer dia Female Brass Threaded Adaptor (FTA/ FBTA) CPVC complete all as specified and as directed.
Supplying and fixing in repairs 20mm outer dia CPVC brass elbow complete all as specified and as directed.
Supply and fixing 15mm bore galvanized steel water tubing, medium grade with all fittings and fixed complete to walls and ceiling or laid in floors including taking down up or down 15mm bore steel tubing galvanized and connection complete all as specified and as directed.
Material and labour for Water tubes of size of 20 mm bore medium grade ISI marked galvanized with all fittings such as bend, elbow, socket, tee etc and fixed complete to wall and ceilings or laid in floors including taking down old unserviceable GI tubing,etc complete all as specified and as directed.
Material and labour for Petty repair to internal/external water inlet water GI/CPVC pipe line of any size coming from over head tank to the quarter including socket,elbow,nipple ,with repair to water blockage , pipe line leakage, cleaning internally , removingof air/dust blockage including concealed water tubing etc n exc 3m length of any height using scaffolding and making the water supply good complete all as specified and directed.
Supply and fixing in repair PVC (SWR) pipes single socket in any length with rubber ring joints of 75 mm bore fixed to wall etc, complete all as specified and as directed.
Supply and fixing in repair PVC bends 75mm bore complete all as specified and as directed.
Supply and fixing in repairs PVC (SWR) floor trap 75mm dia of outlet pipe, plain with grating including jointing with solvent cement complete all as specified and as directed.
Supply and fixing in repairs Stack clamps made out of 50 mm x 5 mm flat iron and 75 mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof for 75 mm bore complete all as specified and directed.
Supply and fixing in repair PVC Dual flush ceramic, colour, cistern , low level, 10 litres capacity, star white with inlet float ball valve, PVC flush pipe and handle, making proper fixing and hanging arrangements complete all as specified and as directed. Make: /Parryware/Hindware/ Cera.
Supply and fixing in repairs of Bib tap standard of PTMT any colour high pressure screwed for iron pipe and fixed.(Minimum weight15mm-90gms) complete all as specified and as directed.
Supply and fixing in repairs of Push tap any colourhigh pressure of PTMTscrewed for iron pipe and fixed, (Minimum weight 15mm-47gms) complete all as specified and as directed.
Supply and fixing in repairs of pillar Tap standard of PTMT any colour high pressure screwed for iron pipe and fixed.(Minimum weight15mm-110gms) complete all as specified and as directed.
Supply and fixing in repairs of Stop Valve standard of PTMT any colour high pressure screwed for iron pipe and fixed.(Minimum weight15mm-90gms)complete all as specified and as directed.
Taking down & re fixing high or low level flushing cistren 10 ltrs capacity & connections to pipe Supply and fixing of chain & pull or lever after cleaning inside all dirt, scale formation, replacement of rubber washers, syphon set, float valve, reqd stopping of leakage etc complete all as specified and as directed
Supply and fixing 150 mm dia round/square grating of CP with or without hole including Jointed to PVC pipe complete all as specified and as directed.
Supply and fixing Vitreous china squatting pan 'Orissa' Pattern size 580x440mm white with integral foot rests (excluding flushing cistern and flush pipe ) including provision of lime concrete bedding fixed in repairs complete all as specified and as directed.
Supply and fixing in repair Wash basin vitrous china (flat back and angle back Type) size 580x400mm including taps waste chain and plug and porceline stopper but brackets including cutting for and pinning in ends of brackets or erecting stand with waste pipe,complete all as specified and as directed.
Material and labour for machine pressed pre polished precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, M-40 Grade over sand cushion with grey cement and no pigment and included side kerb concrete, incl demolition and removal of rubbish off the premises etc complete all as specified and as directed. Note :- Sand will be measured and paid seperately as supply only under relevent item here in after.
Supply only Sand filling under floors or in foundations including watering and consolidation and all as specified and directed.
Material and labour for Machine cut kota stone slab 20-25 mm thick as in flooring, laid over 20 mm thick screed bed in CM 1:6 as bedding layer set and jointed in neat cement slurry and pointed with cement and pigment to match the shade of the slab rubbing and polishing incl demolition and removal of existing floor finish etc complete all as specified and as directed.
Material and labour for Preparation of old decorated plastered or unplastered surface of wall, chajja,ceiling, balcony, facia etc., brooming down or steel wire brushing down smoke soot, moulds mass, efflorescent, trading, oil, greasy spots and applying one coat of white wash complete all as specified and directed. Note:- (i) The unit quoted rate shall be inclusive of material,any helght of Over Head Tank of any size and all labours, tools and plants including scaffolding required for working upto approx 15 mtr height from natural ground level and nothing extra shall be admissible on this account. (ii) Adoption of necessary safety arrangement like safety belts, ropes, helmets, netting etc. which are required for safety of working labour at height exceeding 3 to 25 mtr height shall be mandatary and deemed to be included in the unit rate quoted.
Material and labour for Preparation of old plastered surfaces of wall by using pressure washer, removal of all dirt and dust and applying one coat of exterior emulsion weater proof paint complete all as specified and as directed. Note:- Cost of scaffolding required deemed to be included in the quoted rate of item and nothing extra shall be admissible on this account.
Supply and fixing 4 mm thick sheet glass ordinary quality and glazing complete in square n exc 0.50sqm each complete all as specified and directed.
Supply and fixing frosted glass 4.0mm thick, pin head type n exc 0.5 sq.m in each pane and fixed. complete all as specified and directed.
Supply and fixing in repair Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.4mm complete all as specified and directed.
M & L for 100 mm thick PCC 1:2:4 type B-2 (using 40 mm graded crushed stone agg) as in PCC in Hard standing etc. with , spike rolling ,or making impression of expanded metal, while the concrete is green including demolition of cement Concrete (un reinforced) of any description and in any position not otherwise specifically provided complete all as specified and as directed.
M & L Forming Construction joints 30 mm deep x 10 mm wide filled with epoxy sealing compound complete all as specified and as directed.
Material and labour for broken stone boulders hard core of guage n.exc 63mm deposited spread and level laid in layers n.exc 15cm thick, watered and rammed to a true surface in repairs complete all as specified and directed.
Material and labour for Cement concrete 1:3:6 type C2 (using 40 mm graded stone agg) as in foundation filling and for mass concrete incl demolition of Concrete (un reinforced) of any description and in any position not otherwise specifically provided complete all as specified and as directed.
Material and labour for Pre-Cast PCC 1:3:6 type C1 (20 mm graded agg) cement concrete block masonry with solid blocks exc. 10cm in width and set in cement mortar 1:6 including demolition of brick work /PCC block built in cement mortar of any description complete all as specified and as directed.
Material and labour for rendering 15 mm thick in cm 1:4 on brick surfaces finished even and smooth with out using extra cement complete all as specified and as directed.
Supply and fixing in repair PVC connections 15mm size with PTMT nuts of length 600 mm complete all as manufactures and all as specified and directed.
Supply and fixing in repairs 40mm bore unplasticised PVC pipe of pressure rating 10 kgf/Sqcm fixed complete to walls, ceiling or laid in floors complete all as specified and directed.
Supply and fixing in repair PVC waste pipe 32 to 40 mm dia and length no less then 90 cms for WHB/Sink/Urinal up to floor trap and fixed complete all as specified
Site clearance by cutting grass/wild growth/trees n.exc 0.30m girth etc incl surface dressing in soft/loose soil manually/mechanically including removing of rubbish from the site to a distance exc, 250m but n. exc 500m and deposited where directed at a level not exc. 1.5m above the starting point, complete all as specified and as directed
Taking down of hood cover of rolling shutter of gear operated type area about n exc 6.00 sqm clear of each and greasing to all parts of rolling shutter after replacement of following unserviceable parts as required for smooth function of rolling shutter and refixing the same position properly of any height including bracket :-
(a) Shaft 50mm mild steel pipe.
(b) Gear box sets
(c) Helical spring 600mm long.
(d) Lath patty (strips) of 75mm wide & 1.25mm thick MS.
(e) Ball bearing for 50mm dia pipe.
(f) Crancked wheel
Supply and fixing in repairs Steel rolling shutters, with ball bearing, as specified including top cover, anchoring rod, lath patty, cranck wheel, helical spring, hasp and staple and one shop coat of primer; erected in position as indicated, complete: push pull, manual or gear type Thickness of laths 1.25 mm and all as specified and directed.
Taking downn unsv funnel of any type and size Supply and fixing in repair GI funnels for earthing complete all as specified and as directed.
Material and labour forPowder Earthing Backfill Compound, Grade Standard for improvement of earthing resistivity and to increase the absorption of moisture around the earthing electrode complete all as specified and directed.
Material and labour for magnesium sulphate (MgSO4) for improvement earthing resistivity complete all as specified and directed.
Material and labour for Brazing of copper/Aluminium/GI strip for continuity complete all as specified and as directed.
Supply only common salt commercial in trenches to improve the ER value of existing earth pits complete all as specified and as directed.
Supply only charcoal dust/Breeze in trenches to improve the ER value of existing earth pits complete all as specified and as directed.
Taking down existing GI earthstrip 25x3mm thick as earthling lead with its accessories and re fixing to wall/roofs etc. drawn in conduit/GI pipe etc all as specified and directed. Note:- Unite rate is deemed to be included for old broken insulators/ clamps replace with new insulators of existing size from site and making good disturbed surfaces of floors/walls/ceiling etc complete all as directed.
Material and labour in repairs for Galvanised Earth strip of size 25 x 6 mm fixed on proper post insulator at the instrument end complete all as per specified and as directed.
Material and labour for Copper strip 20 x 3mm thick as earthing lead fixed to wall/roofs etc including taking down existing one all as directed. NOTE : All Joints should be joined by Exothermic Welding or Brazing.
Supply and fixing in replacement of aluminium strip 25x3mm fixed with epoxy based insulator for down conductor air terminal network including drilling two Nos holes at each joint, one set of lead washers between strips, two sets GI nut and bolt, gutties, screws etc all as specified and as directed .
Material and labour for fixing earth indicators made out of 3 mm thick MS sheet of size 200mm x 300mm duly fixed in MS angle iron 25mmx25mm of 450 mm long to be fixed to ground by means with neceaary cement concrete and painting with two coats of synthetic enamel paint over a coat of red oxide primer complete, writing earth reading and connected items like palnting of panel etc, and necessary excavation and earth work including taking down old complete all as specified and as directed.
Repairing and maintenance of old existing earth pit by taking out carefully earth plate, watering pipe, earth lead protection pipe and re-buried the same after removing sludge from the plate & pipes including re-connection/brazing the plate and strip, whichever is required at site (Earth pit not less than 2.25 mtr deep below normal ground level ) with top edge of earth plate not less than 1.5 metres below normal ground level,complete all as specified and directed including PCC 1:3:6 type C1 pit with cover of RCC 1:2:4 type B1,reinforced with welded steel wire fabric not less than 4 kg per sqmtrwith handle andangle iron frame,watering arrangment with 20 mm bore GI medium grade pipe ISI marked, GI funnel with GI mesh,filling with mixture of commen salt and charcoal,necessary excavation, refilling, removing away soil and earth work in any type of soil including test point, testing and commissioning complete all as specifed and as directed. Note : GI Funnel, brazing, mixture of salt/char coal/MgSO4 shall be measured and paid separately under releavant items.
Material and labour for earthing complete with copper earth plate electrode 60x60cmx3.15mm buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top dege of the plate not less than 1.5 meters below normal ground level, connected to 20X3mm copper strip as earthing lead by means of bolts, nuts, check nuts and washers of copper all as shown in elctrical plate No 3 connected to earthing test point including excavation/ earth work in any type of strata, removal of surplus excavated material, GI pipe for watering and funnel, PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 in cover slab with GI protection pipe but all as specified and directed by Engineer-in-Charge. all as specified including testing on completion and taking down old earthing material.
Supply and fixing in repair test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm longhex. head screw all as specified and directed.
Material and labour for Surface excavation n.exc 30 cm deep and averaging 15 cm deep in hard /dense soil and getting out all as specified and as directed.
Excavation in trenches in soft/loose soil not exceeding 1.5 mtr in width and not exceeding 1.5 mtr in depth for laying of cables up to proper level complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed.
Removing surplus excavated material from excavation not exc 50 meter and depositing where directed at a level not exc 1.5 meter above the starting point complete all as specified and directed.
Material and labour for Spreading ribbed soil in trenches as in cable cushioning all as per IS 1255-1983 and as directed. Note :- Excavated approved soil obtained from excavation under item No 112 shall be ribbed by using sieve to separate composite particles etc as per IS and refilling in trenches before laying of cable 8 CM and 15 CM after laying of cable. This is than gently punned down to a depth of 10 cm above the top of upper most cable (ii) For the purpose of measurement only punned thickness will be considered for payment.
Material and labour for well burnt class ‘B’ bricks as mechanical protection to under ground cables laying with length of the bricks equal to the width of the trench complete all as specified and directed.
Material and labour for Cutting existing road/PCC/Drain for laying of GI or any type of pipe including necessary earth work, excavation exc 600mm depth but not exc 1mtr depth, wide 800mm including making good existing surface with 150 mm thick PCC 1:2:4 type B1 using 20mm graded stone aggregate complete all as specified and directed. Note :- The tenderer shall take into consideration for following points while quoting rate for this item and the unit rate is deemed to be inclusive for (i) Earth work excavation in any type of soil (ii) Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick complete all as specified and as directed. (iii) Removing excavated material to out side MD land (iv) Laying of any type/any bore of pipe in trenches including taking down any description. Supply of pipe will be measured and paid separately (v) 150 mm thick PCC 1:2:4 type B1 using 20mm graded stone aggregate as in road to make good existing disturbed surfaces.
Supply and laying of GI pipe light grade for cable protection of size 80mm bore complete with fitting complete including taking down unserviceable pipe all as specified and directed.
Material and labour in repair for 3 ½ core 240 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheather laying in trenches/cable ducts, fixed to wall/pole complete all as specified and directed.
Material and labour in repair for 3 ½ core 120 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheather laying in trenches/cable ducts, fixed to wall/pole complete all as specified and directed.
Material and labour in repair for 3 ½ core 95 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheather laying in trenches/cable ducts, fixed to wall/pole complete all as specified and directed.
Material and labour in repair for 3 ½ core 70 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheather laying in trenches/cable ducts, fixed to wall/pole complete all as specified and directed.
Boring of holes under road, pavement hard standings by trenches technology using ultra sound technique and necessary machine including HDPE pipes of 100 mm dia suitable for 0.4 Mpa working pressure complete all as specified and directed.
Supply, Fabricate install test and commissioning of Bus bar box out door type totally enclosed dust and vermin proof floor mounting with hinged doors and locking arrangement front and back fabricated out of 3.15 mm thick CRCA sheet including powder coated paint finish including all accessories, provision independent removevable MS plates for fixing cable glands for all sutable for 300sqmm X3.5 core UG cable incomming and out going cables and complete control wiring with 2.5 sqmm copper conductor incuding 1:3:6 necessary excavation and earthwork PCC foundation complete all specified and directed. Note :- (1) Rates deemed to be included for suitable lugs and glands for incoming and out going of LT UG cable. (2) The Contractor Shall submit the drawing with sample of accessories for approval before executing the work. INCOMING (a) Aluminium busbar of capacity 400 Amps with eppoxy insulated supports 3 phase and neutral -1 set (b) MCCB 200 Amps 4 pole 36 KA with adjustable type - 01 No
Fabrication, supply, install, test and commissioning of Bus bar box out door type totally enclosed dust and vermin proof floor mounting with hinged doors and locking arrangement front and back fabricated out of 3.15 mm thick CRCA sheet including powder coated paint finish including all accessories, provision independent removevable MS plates for fixing cable glands for all sutable for 300sqmm X3.5 core UG cable incomming and out going cables and complete control wiring with 2.5 sqmm copper conductor incuding necessary excavation & earthwork 1:3:6 PCC foundation complete all specified and directed. Note :- (1) Rates deemed to be included for suitable lugs and glands for incoming and out going of LT UG cable. (2) The Contractor Shall submit the drawing with sample of accessories for approval before execution of work. INCOMING (a) MCCB 200 Amps 4 pole 36 KA with adjustable type - 01 No (b) Aluminium busbar of capacity 400 Amps with eppoxy insulated supports 3 phase and neutral -1 set
Material and labour in repair for Fabricate supply install test and commissioning of Bus bar box out door type totally enclosed dust and vermin proof floor mounting with hinged doors and locking arrangement front and back fabricated out of 3.15 mm thick CRCA sheet including powder coated paint finish including all accessories, provision independent removevable MS plates for fixing cable glands for all sutable for 300sqmm X3.5 core UG cable incomming and out going cables and complete control wiring with 2.5 sqmm copper conductor incuding necessary excavation & earth work PCC 1:3:6 foundation complete all specified and directed. Note :- (1) Rates deemed to be included for suitable lugs and glands for incoming and out going of LT UG cable. (2) The Contractor Shall submit the drawing with sample of accessories for approval before execution of work. INCOMING (a) MCCB 100 Amps 4 pole 16 KA with adjustable type - 01 No (b) Aluminium busbar of capacity 200 Amps with eppoxy insulated supports 3 phase and neutral -1 set
Material and labour for Earthing complete with galvanised steel earth plate electrode of size 600 x 600 x 6 mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of plate not less than 1.5 m below ground level connected to and including galvanised earth strip of size 25x6 mm (up to 7.5 mtr length) and GI pipe 40 mm light grade for protection of GI earth strip by means of bolts, nuts, check nuts and washers made out of galvanised iron and connected to earth test point as shown in electrical plate No. 3 of SSR Part-1-2009 and as specified or indicated and testing on completion including excavation and earth work any in type of strata available at site, PCC (1:3:6) type C-1 for earth chamber, precast RCC slab 50mm thick in cement concrete (1:2:4) type B-1 reinforced with welded steel wire fabric (xpm) weight not less the (4kg/sqm) funnel with GI watering pipe of 20mm bore medium grade, wire nuts and lugs complete all as specified and directed. Note :- (a) All Joints should be joined by Exothermic Welding or Brazing. (b) After completion of work earthing shall be tested by the contractor in presence of Engineer-in-Charge, User and proper record shall be maintained duly signed by all concerned. (c) Earth resistance tester shall be provided by the contractor. It should be caliberated from authorised company/ lab. (d) After testing if desired earth resistance of less than 5 Ohm is not achieved, the earthing will be redone at no extra cost to Govt till desired result is obtained.
Taking down old out lived / fully oxidised ACSR conductor 4 wire / 2wire from existing LT poles after disconnecting necessary jumpers insulators complete all as per specified and as directed.
Material and labour for ACSR conductor of any size for LT over head lines and jumpers complete all as per specified and as directed.
Material and labour for GI wire 4mm dia fixed to LT pole all as directed for earth continuity including taking down the old Unsv rusted GI wire from the pole complete all as per specified and as directed.
Material and labour in repair for Pin type porcelain vitreous white brown or green insulator including one galvanised mild steel spindle two galvanised iron washers and one galvanised iron nut 100 mm height 65mm dia for 1100 volts grade complete all as per specified and as directed.
Material and labour in repair for shackle type insulators porcelain vitreous white brown of green including GI mild straps 31x3mm 75mm height, 90mm dia at working pressure 1100 volts complete all as per specified and as directed.
Material and labour in repair for stay assembly comple with accessories as shown in electrical plate No. 1 with 16 mm dia rod and loop type insulator stay clamps etc complete all as per specified and as directed. (Excavation and concrete will be measured and paid separately.)
Material and labour in repair for loop type porcelain vitreous white brown or green insulator with overall dimensions 65mmx 90 mm clearance of hole 16 mm etc complete all as per specified and as directed. .
Material and labour in repair for fixing GI stay strand of size 7/3.15 mm complete all as per specified and as directed.
Material and labour in repair for Servicing to LT panels/Feeder pillar boxes/APFC Panels comprising MCCBs/switch disconnector fuses/change over switches metering eqpt etc. as incoming/outgoing controls including cleaning, checking the serviceability of individual items, identification of the defective parts replacing the worn-out fasteners, insulators, rubber door beadings, gaskets etc. complete all as specified and directed. Note :- Unserviceable parts replaced shall be measured & paid separately under relevant item
Material and labour for Painting of LT panel board/feeder pillar boxes with two coats of synthetic enamel spray paints over a coat of red oxide primer matching existing colour after scrapping the old paint by means of emery paper and cleaning with thinner including necessary markings/sign writing etc. complete all as specified and directed.
Supply and fix in repair the MCCB of capacity 250 A 415 Volts 4 pole with breacking capacity 36 KA in LT panel boards / feeder pillar boxes including disconnecting and removing existing from electric connection including necessary connected fastners, burnt cables, accessories like spreader ,cages etc all as per site requirement/existing make/model,all as specifed and as directed.
Material and labour for Testing of earth resistance value from earthing pit test terminal point and write in/ on existing identification board complete all as specified and as directed. The following items are deemed to be inclusive of quoted rate :- (i) The above job shall be carried out by a trained technician having ITI in electrical and well known regarding earthing test. Documantary proof of the education of tradesman shall be produced, before commencement of work. (ii) The aforsesaid test will be carried out in presence of user and MES represnetative. (iii) Two Party (consisting 2 x 1 No. Technician with 2 x 1 No. Helper) will report every Morning at 9 AM to JE E/M for Daily earth testing. (v) Earth Resistance Tester will be provided by the Contractor. (Tester should be caliberated from Authorised Company/ Lab). (vi) Contractor will be responsible for pouring of water in the Earth Pits Weekly at their own arrangement with Water Tanker, etc. (water will be provided by the contractor at his own arrangement and nothing extra will be admissible). (viii) Contractor will be responsible for marking of Earth check date and due date on existing Plate with paint as specified by Engineer-in-Charge. (ix) Contractor will be responsible for cleaning of bushes and grass all around upto 1.50 Metre Area of existing Earth Pit with tightening of Strip.
Supply and fix in repair 25 watts, 230 V LED light fitting with suitable bracket with connected items complete for Building security LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having top opening seperate driver compartment with IP66 protection and impact resistance of IK07 etc complete all as specified & directed. Make:Philips/Bajaj/CG
Supply, installation, testing and commissioning of smart street light control system using GSM/Lux based technology having 12 KW 3 phase 32 amp load capacity per phase and can be operated by IVRS/SMS/lux based infrared sensor etc complete with following:- (i) Nature switch operation should be based on natural light lux level. Require illuminnance level for switching on is ≤ 60 lux and for switching off ≥ 10 lux. The smart unit should have 4 timers that can be set via SMS. (ii) Surge protection device (SPD) should provide protection agaist indirect lightning & switching surges. It should conform to IEC61643-11 and should have 40 KA capacity. (iii) The sensor & SPD along with suitable power contactors and incoming-outgoing MCCB/MCBs should be enclosed in a enclosure made of rust proof, electric shock proof , metal whether proof conforming to IP65 with angle iron frame of suitable size 04 Nos legs 600 mm long , PCC 1:2:4 type B1 for grouting of base including taking down unserviceable panel. The scope of work also comprising the following :- The GPRS shall have seven segment display to show voltage, current, network and street light status , it should also have indicator for showing supply status , timer , overload or high low voltage. It should also able to measure voltage, current and automatic set street light overload current. Unit have facility to call back to registered number for power on/off and if any fault occurs at site.in SMS it should also monitor power/on/off time light on off time, ampere, voltage, unit mode, network percentage date and mobile number who called device number. The device should also have battery backup with minimum 24 hours backup capacity. The panel should have three operation mode :- 1. GSM mode -in this mode light should be switched as per GSM controller's preset time by user by sms , 4 clock base timer facility should be availble 2. Nature switch based-in this mode light will be switches as per nature light lux level 3. Bypass mode -in this mode light will switched on directly for testing purpose and emeregncy switching .In GSM controller there should be facility to register 4 user by sms/call and alerts will be sent on all registered number and also call back on power on/off and faults on first registered number.The Gsm controller should also compatible for cloud based data transmission for interfacing with web for future use, Password protection for Accessing the control of device via SMS/IVRS complete all as specified and directed including the following subcomponentSupply and fixing eatures :-
(a) MCCB 100 Amps capacity, 10 KA, 415 Volts -01 No (Incoming) with separate SPD of 40 KA capacity. (Make of MCCB- L & T, BCH, Havells) (b) Supply Resign cast CT'S - set of 3 (c) Gsm based smart street light controller. (d) Lux based sensor to operate external as per light intensity. (e) Line Contactor, AC 3 duty, 3 phase, 415 volts. 50 Hz , 25 Amps -03 Nos (make - L & T, BCH, Havells) (f) MCB SP 32 Amps- 03 Nos (make -L & T, BCH, Havells) (g) Terminal block suitable for 100 A rating with brass contacts for INPUT/ and 63 A for OUTPUT termination. (h) GSM/Timer/Bypass Mode switch. (j) Panel wiring for control circuit with copper flexible 1.5 sqmm & power wiring 10 sqmm flexible. Make- Tricolite/ Kewintech/HPL
Supply and fix in repair the MCCB of capacity 100 A to 125 A, 415 Volts 3 pole with breacking capacity 25-36KA in Exisitng LT panel boards / feeder pillar boxes including disconnecting and removing existing from electric connection including necessary connected fastners, burnt cables, accessories like spreader ,cages etc all as per site requirement/existing make/model,all as specifed and as directed.
Supply and laying in repair GI pipe light grade for cable protection of size 40mm bore complete with fitting complete all as specified and directed.
Material and labour for making straight through joint with suitable jointing kit consisting water proof adhesives for UG cable of size 3 1/2 core 120 sqmm to 150 sqmm complete all as specified and directed.
Material and labour in repair for making straight through joint with suitable jointing kit consisting water proof adhesives for UG cable of size 3 1/2 core 185 sqmm to 300 sqmm complete all as specified and directed..
Material and labour in repair for making straight through joint with suitable jointing kit consisting water proof adhesives for UG cable of size3 1/2 core 50 sqmm to 95 sqmm complete all as specified and directed.
Material and labour in repair for making straight through joint with suitable jointing kit consisting water proof adhesives for UG cable of size 3 1/2 / 4 core 25 to 35 sqmmn complete all as specified and directed.
Material and labour in repair for cable route indicator made out of CI plate 100 dia,6mm thick and fixed over angle iron of size 30X60X6 mm,120cm in length duly painted with alumiuium paint with aluminium paint suitable for LT cable all as specifed including embeding in PCC (1:3:6) type C1 of size 30X30X20cm in ground complete all as specified and directed. Note :- An amount of Rs 85479.00 on account of credit schedule for schedule 'A' part II shall be deducted from the total amount of BOQ to arrive at the contract sum.
Forge Engineering & Electricals
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .