Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.5 LAccepted-AOC 86 CHAK16 QAZIPURA TANDA RAMPUR UTTAR PRADESH 244925 | RAMPUR | UTTAR PRADESH | 244925 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹30.9 L+₹48,017 (1.58%)Rejected-Finance 5 6 MINTO ROAD ALLAHABAD 211001 | PRAYAGRAJ | UTTAR PRADESH | 211001 | L2 | Rejected-Finance Being not lowest | |
| 3 | L3₹36.3 L+₹5.8 L (19.0%)Rejected-Finance | L3 | Rejected-Finance Being not lowest | |
| 4 | L4₹36.8 L+₹6.3 L (20.8%)Rejected-Finance | L4 | Rejected-Finance Being not lowest | |
| 5 | L5₹38.4 L+₹7.9 L (26.1%)Rejected-Finance 46 HUSENI LAKDA BAZAAR 242 BELLASIS ROAD MUMBAI 400008 | MUMBAI | MAHARASHTRA | 400008 | L5 | Rejected-Finance Being not lowest |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
27 Feb 2025, 6:00 pmClosed
Kameshwar Prasad, IDSE, EE
GE (W) Colaba, Mumbai
Special Repairs to RCC Staircase, Structural Members, Roof, Chajja and Joinery of Bldg No. P-30 (Offrs Md Accn) under GE (W) Colaba, Mumbai
2025_MES_695518_1
8955/E8
Open Tender
Civil Works
Item Rate
180 days
GE (W) Colaba
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE (W) Colaba, Mumbai
₹96,000
Yes
17 Mar 2025
30 Jan 2025
1 Mar 2025
30 Jan 2025
27 Feb 2025
13 Feb 2025
Amount
Identifying and marking carefully the damaged reinforced concrete by tapping with light hammer and chipping of unsound weak concrete and plaster material from slab/beams/columns with power/hand driven chisel as directed by the engineer-in-charge upto 25 mm average depth including saw-cutting of all edges making square shoulders of the cavities all as specified and as directed. (All loose unsound and cracked concrete shall be removed out side MD land) Note: Thickness shall be measured excluding plaster.
Identifying and marking carefully the damaged reinforced concrete by tapping with light hammer and chipping of unsound weak concrete and plaster material from slab/beams/columns with power/hand driven chisel as directed by the engineer-in-charge upto 40 mm average depth including saw-cutting of all edges making square shoulders of the cavities all as specified and as directed. (All loose unsound and cracked concrete shall be removed out side MD land) Note: Thickness shall be measured excluding plaster.
Identifying and marking carefully the damaged reinforced concrete by tapping with light hammer and chipping of unsound weak concrete and plaster material from slab/beams/columns with power/hand driven chisel as directed by the engineer-in-charge upto 60 mm average depth including saw-cutting of all edges making square shoulders of the cavities all as specified and as directed. (All loose unsound and cracked concrete shall be removed out side MD land) Note: Thickness shall be measured excluding plaster.
Cleaning loose concrete if any all around reinforcement including from behind the reinforcing bars to give an average 10 mm thick (but not less than 10 mm clear air gap) and cleaning reinforcement of total rust using alkaline rust remover with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washed with water and allowing it to dry and applying two coats of epoxy based passivating, protecting & bonding coat of zinc rich system (Nitozinc (R) primer of Fosroc and equivalent of SIKA/Dr Fixit Pidilite/ Krishna Conchem) as approved by the Engineer-in-Charge for old and new reinforcement any dia all as specified and directed. Note : - Length of reinforcement bars cleaned of rust all around shall be measured for payment.
M&L mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips including welding has to be done with minimum 20 cm over lap for new and old of any height all as specified and directed.
M&L mild steel TMT bars any dia in stirrups, spaces and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips all as specified and directed
M&L plastering 15--25 mm thick (Avg) polymer modified cement mortar in two coats, 15 mm base coat and subsequent finishing coat with and including curing as per manufacturer's instruction all as specified and as directedby Engr-in-Charge. Note : - Ready to use bags will be used for the above item and no extra cost wiil be claimed by the contractor
Providing and placing in position micro-concrete, grade M-40, which shall be cement based prepacked single component, chloride free, non-shrink, free flow, self compacting, ready to use after mixing water in specified proportion, obtained from Fosroc / SIKA / BASF/ Dr Fixit, thickness of section upto 75 mm all as specified and as directed by the Engineer in charge (Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/tapping with a blunt metal instrument)
M&L for RCC work as in columns, beams, slabs, chajja, railing in M-25 (Nominal Mix) using 20 mm nominal size crushed stone aggregate all as specified and directed.
Use & waste special water tight centering and shuttering including bolting, strutting, propping so as to withstand a pressure of 0.1 Mpa including removal of form work all locations including beams, columns, slabs, walls, foundations, footings, landings, stairs, balconies all as specified and as directed.
M&L for repairs to sunken portion of slab treatment of sunken floor slab compraises of the following specifications :- (i) M&L for cleaning the sunken/lowered portion of RCC slab surface (including vertical total depth plus skirting height) of floors by wire brush, chisel out any mortar sticking to the surface and brooming completely. 40mm thick average PCC 1:2:4 type B-0 using 12.5mm graded crushed stone aggregate as in padding concrete to achieve proper slope including cutting holes in bricks or RCC wall for spout. (ii) Rendering of uneven surfaces with 6mm thick in CM 1:4 mixed with integral water proofing compound @ 3% by wt of cement consumed. Fill it with water and check dampness and seepage. Where dampness/seepage is noticed, nozzles shall be fixed and grouting carried out. (WPC shall be measured & paid separately). (iii) All junctions points of side wall where CI/GI pipes are passing through shall be sealed with epoxy puty. (iv) After drying putty, wash the slab and sides of sunken portion with water and make it clear and clean. (v) M&L for applying two coats of polymer modified cementious water proof coating with DR. Fixit Pidicrete URP with cement Ratio 1:1.5 as per manufacturs instruction to bottom and vertical sides up to finished floor level+100mm height. The thickness of two layer shall be 1mm. When the second layer is still sticky, coarse sand spray shall be carried for the vertical and bottom surface of the sunken portion all as specified and directed. (vi) Plaster the bottom and sides up to full height of sunken with minimum 20mm thick CM 1:4 mixed with integral water proofing compound ( DR.Fixit Pidifin 2K) 3% by wt of cement consumed as per manufacturer's specification including rounding of corners and junctions sloping towards spout.( WPC shall be measured & paid separately) (vii) All pipes laid in sunken portion shall be covered with 50mm thick PCC 1:3:6 all round after painting with anticorrosive paint. Note 1 :- Test the water proofed area (ponding test) by filling water for at least 72 hours and tested for leakage seepage and to the entire satisfaction of GE. Test shall be done in presence of reps of MES and record for each sunken slab shall be maintained. Cost of testing is inclued in the rates quoted above. For the purpose of payment area of bottom and sides of sunken shall be measured in sqm
Taking down cement plaster of any description on brick or stone walls, etc including raking out joints, hacking for key, scrubbing down with water and removing debris outside MD land (from ground floor to fourth storeys bldgs) including use of scaffoldings all as specified and directed.
M&L for removing loose, disturbed or disintegrated old concrete / brick surfaces of walls, RCC beam, column, lintel, pardi, railing etc, cleaning thoroughly exposed reinforcement, by sand blasting using suitable pump as directed by the GE, preparing exposed concrete surfaces to receive guniting, applying one coat of anti corrosive paint to the exposed reinforcement, applying pressure guniting in cement mortar 1:3, average thickness 30mm to 50mm and thereafter rendering 10 mm thick plaster in cement mortar 1:3, mixed with water proofing compound in the ratio as per the manufacturer's instructions and finishing the surfaces even and smooth without using extra cement to match with the existing surfaces, removing the debris outside MD land including material and labour and safety arrangement for guniting work all as specified and directed. Note :- (i) The finished level of the surfaces shall be matched with the existing surface. WPC shall be measured & paid separately as supply only. (ii) Provision of additional reinforcement steel in case required and ordered shall be measured and paid separately.
M&L 15mm thick Ready Mix Plaster in single layer mixed with liquid water proofing compound on other than fair faces of brick wall or concrete surfaces, (upto 05 storeys of bldgs) including use of scaffolding all as specified and directed.
Supply only liquid water proofing compound.
M&L for preparation of new plastered surfaces of wall and applying two coats of oil bound distemper over a coat of alkali resistant priming paint over 2mm thick (average) wall putty all as specified and directed.
M&L for preparation of old surfaces of wall and applying two coats of oil bound distemper over a coat of alkali resistant priming paint over 2mm thick (average) wall putty all as specified and directed.
M&L for preparation of new plastered surfaces of ceiling and applying two coats of oil bound distemper over a coat of alkali resistant priming paint over 2 mm thick (average) wall putty all as specified and directed.
M&L for preparation of old surfaces of ceiling and applying two coats of oil bound distemper over a coat of alkali resistant priming paint over 2 mm thick (average) wall putty all as specified and directed.
M&L for removing plants including roots by dismantling of brick work/PCC including necessary scaffolding of any type and in any position or location i.e roof, parapet walls near pipes etc and applying acid after removing roots for preventing the re-growth & making good of disturbed portion using PCC 1:2:4 type B0 & 10mm thick cement plaster in CM(1:3), size of disturbed portion not exec 150mm X150mm X 200mm all as specified and directed.
M&L for filling cracks by cutting 'V' groove cracks of internal or external plaster of walls, ceilings/Chajjas all along the crack upto 10 mm and remove the loose plaster/concrete by suitable tools, filling cracks with crack paste compound and apply the second coat after 10-12 hrs of application of first coat and for external application must be coated with paint including necessary scafolding of any height all as specifed and direcetd.
M&L for cleaning all loose laitance on the wall and concrete substrate and applying one coat of epoxy bonding agent of SBR latex on exposed concrete surface to ensure bond between old concrete & new concrete by brush application including scafolding at any height as specified and directed.
Dismantling of floor hearth or wall tiling including cement mortar bedding but not backing and removing rubbish off the primises out side of MD land all as specified and directed.
M&L Screed bed or bedding layer of mortar 15 mm thick in CM (1:6) for laying floor finishes like tiles all as specified and directed.
M&L rendering 10 mm thick plaster on fair faces of brick work in CM (1:4) all as specified and directed.
M&L Hi-Gloss digital ceramic tiles in vertical surface of size 600mm x 1200mm x 8 to 10 mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match the shades of the tiles all as specified and directed. Note : The above item will be executed by applying tile adhesive of approved make and as per manufactures instructions.
M&L non skid ceramic cololured tiles 7 to 8 mm thick (square/rectangular) area of each tile exc 0.18 Sqm but n.exc 0.36 Sqm in floors laid over 15 mm thick screed bed or bedding layer of mortar in CM 1:4 for laying floor finishes all as specified and directed.
Demolition of stone slabs and tiles of any description or thickness in floors, aprons, dados, etc laid, bedded and pointed in any mortar and removal of rubbish off the site out side of MD land all as specified & directed.
M&L for granite (of any colour) 18- 20 mm thick machine cut, pre polished, bedded and jointed with grey cement slurry and pointed with white cement with admixure of pigment to match the shade of granite stone as in kitchen platform, flooring , window cill, wall cladding including 15 mm thick screed bedding in cement mortar 1: 6 and all other similar works all as specified and directed.
Taking up or down steel tubing and connection including cleaning for refixing or removed to store,15 mm dia bore all as specified and directed
Taking up or down steel tubing and connection including cleaning for refixing or removed to store, 20 mm dia bore all as specified and directed
Taking up or down steel tubing and connection including cleaning for refixing or removed to store, 40 mm dia bore all as specified and directed
S&F GI tubing 15mm bore medium grade with all fittings and fixed complete to wall and ceiling or laid in floors all as specified and directed.
S&F GI tubing 20 mm bore medium grade with all fittings and fixed complete to wall and ceiling or laid in floors all as specified and directed.
S&F GI tubing 40mm bore medium grade with all fittings and fixed complete to wall and ceiling or laid in floors all as specified and directed.
Cutting chases, pinning in and making good to facing on brick walls where required and pointing in cement mortar (1:3) to ends for concealed water tubing and making good, cutting n, exc. 10cm girth all as specified and directed.
S&F in repairs wash hand basin table top of size 415x345x170 mm vitrous China including, waste coupling & PVC waste pipe of 32 mm dia all as specified and directed.
S&F in repairs 15 mm dia bore fancy type chromium plated long body bib taps with wall flange cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe, or for brass ferrule all as specified and as directed.
S&F in repairs 15 mm bore fancy type two way bib taps long body cast copper alloy 15mm bore with fancy chromium plated screwed down, screwed for iron pipe or for brass ferrule all as specified & directed.
S&F in repairs brass chromium plated shower rose 300 mm of size with arm and with or without swivel joints to steel pipe or union all as specified and as directed
M&L in repairs single piece WC with PP thin rim seat cover white, fixing accessories, accessories set and cistern fitting size 665x355x770 mm and necessary fittings all as specified and directed.
S&F in repairs brass chromium plated towel rack with 3 hooks 18" (Oval Range) all as specified and directed.
S&F in repairs chromium plated towel rings fixed with screws all as specified and directed.
S&F in repairs 15 mm bore chromium plated Angular stop valve with wall flange of cast copper alloy screwed down high pressure with crutch or butter fly handle screwed both ends for iron pipe or for unions and fixed all as specified and directed.
S&F in repairs corner glass shelf 200 mm (brass brackets) of Kerovit Cat Part No - KA920009 /Kohler all as specified and directed.
S&F in repairs Brass CP pillar cock with extension body including all necessary fittings screwed down for iron pipe for Wash Hand Basin all as specified and directed.
S&F in repairs mirror cabinet PTMT of size 400mm x 500 mm with magnetic looking arrangements fixed with and inclduling chromium plated brass screws and PVC rawl plugs all as specified and directed.
S&F in repairs stainless steel peg set of suitable size of length all as specified and directed.
S&F in repairs toilet paper holder of stainless steel fixed to wall with CP brass screw all as specified and directed.
S&F in repairs chromime plated, cast copper alloy jet spray with 1-1.5 mtr SS chrome plated hose and hook (for European seat) all as specified and directed.
S&F in repairs PVC connection 15mm size PTMT nuts of length 450 mm all as specified and directed.
M&L in repairs CP soap dish all as specified and as directed
M&L in repairs tumbler holder all as specified and as directed
S&F in repair KOHLER ESSENTIAL RECTANGULAR MIRROR IN MATTE BLACK FINISH of size 560mm X 864mm and fixed to walls using hidden studs all as specified and directed.
S&F in repairs 15 mm bore concealed stop cock (regular body) cast copper alloy screwed down, high pressure, with crutch or butter fly handle, screwed both ends for iron pipe or for unions all as specified and directed.
S&F in repairs Stainless steel sink, 1.00mm thick for kitchen or laboratory, with plug, waste pipe, washers, including cantilever cast iron brackets, connecting union etc., overall size 495mm x 420mm with bowl size 410mm x 330mm x 160mm all as specified and directed.
Demolition of Cement concrete (reinforced) of any description and in any position not otherwise specifically provided all as specified and directed.
S&F anodised aluminium sections for doors, windows, ventilator door partition including fabrication of frame shutters and fixed with necessary lugs, cleat rollers, handles, locking arrangement, etc. including all necessary accessories such as glazing clips, provn of AC opening and rubber beading for fixing glass beading for fixing glass panels in frame all as specified and directed. Note- (i) Glass panes will be measured and paid separetly. (ii) The quoted rate shall be inclusive of cost of rubber beading and glazing clip hinges, handle however it will not be weighted and not paid separately. (iii) All other minor details including cost of locking arrangement shall be included in the quoted rate.
M&L 5.5 mm thick sheet glass, ordinary quality and glazing with aluminium beads and rubber gaskit in square exc 0.5 sqm in each pane frosted on one side all as specified and directed.
S&F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples all as specified and directed.
S&F 15 micron coloured aluminium anodised grill design No DG-117, 10 mm thick including F Sections all as specified and directed.
M&L for preparation of new wooden surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint (ordinary paint tint) (each coat) over a coat of pink primer including scafoldings of any height all as specified and directed.
Taking down chowkhats or frames with shutters (without taking off shutters from frames) area not exc 1.5 sqm each all as specified and directed.
Taking down shutter of any description area exc 1.50 sqm and n exc 4.00 sqm each all as specified and directed.
S&F factory made single extruded WPC (Wood Polymer Composite) solid door Frames/Chowkhat comprising of 62 mm x 32 mm size applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold unserviceable fast/lugs/SS dash fasteners of required dia and length all as specified and as directed.
S&F factory made 28-30 mm thick single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size, modulus of elasticity 850 N/mm” and resistance to spread of flame of Class A category with property of being termite/ borer proof, water/ moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws all as specified and directed by Engr-in-Charge
S&F Aluminium anodised 100 mm long butt hinges type B-21 with galvanised mild steel screws all as specified and directed.
S&F Aluminium anodised barrel tower bolts, 150 mm long of extruded section all as specified and directed.
S&F Aluminium anodised handles, cast type anodised 150 mm long all as specified and directed.
M&L for cement concrete type B1, 1:2:4 (using 20mm graded crushed stone aggregate) as in hold fast, bed plates and all other similar works all as specified and directed.
S&F mild steel work in hold fasts, wall ties, pintle hinges and all other similar small articles conforming to Fe-290 Gde-E-165 all as specified and directed.
M&L for preparation of old painted steel surfaces of any description over 10 cm width or girth, not otherwise described and applying one coat of synthetic enamel paint all as specified and directed.
S&F in repairs 20 mm dia decorative fancy type SS curtain rods and all other connected works all as specified and directed.
S&F in repairs 20 mm dia decorative fancy type SS curtain rod brackets all as specified and directed.
S&F hot rolled medium and high tensile structural steel of grade E 250 quality A conforming to IS 2062: 2011 as in joist, channel, angle, flat iron or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20 mm of the length indicated) all as specified and directed.
S&F in repairs 75 mm dia PVC(SWR) pipes single socketed in any length with rubber ring joints, sealed with adhesive suitable for PVC pipes and fixed to walls all as specified and directed. Note : The aboe item inculde upto any height of builidng and including necessary scafolding
S&F in repairs 110 mm dia PVC(SWR) pipes single socketed in any length with rubber ring joints, sealed with adhesive suitable for PVC pipes and fixed to walls all as specified and directed. Note : The aboe item inculde upto any height of builidng and including necessary scafolding
S&F 75mm dia PVC (SWR) bends without access doors of any radius all as specified and directed.
All as per item No 78 above but with access door
S&F 110 mm dia PVC (SWR) bends without access doors any radius all as specified and directed.
All as per item No 80 above but with access door
Demolition of cement concrete in ground floor n.exc 15cm thickness (below or above ground level) and removing the demolished material and debris out side MD land all as specified and directed.
M&L for minor cleaning work, removal of loose concrete and filling cracks with polymer modified mortar using SmartCare RP or Epoxy Mortar and supplying and applying High performance hybrid polyurea elastomeric waterproofing coating cold applied of spray / brush applied, SmartCare Ultron liquid membrane with an elongation of 600% and tensile strength of 12.6 N/mm2 as per ASTM D 2370, crack bridging ability of 3mm as per ASTM C1305, shore A Hardness of min. 75 as per ASTM D 2240. The system includes final base preparation, epoxy primer application and applying SmartCare Ultron or approved equivalent in two coats at 1.5 kg per Sqm etc, complete as per Manufacturer specifications over and including padding of PCC Type B1, 1:2:4 (using 20 mm graded crushed stone aggregate) 75mm average thick on RCC roof surfaces and all other similar works all as specified and directed.
Demolition of brick work including all quoins, arches, pillars, etc. but excluding ashlar facings built in cement mortar all as specified and directed.
M&L for brick work with sub class 'B' bricks straight or curved on plan exc 6 mtr mean radius built in CM 1:6 all as specified & directed.
S&F 75mm thick PVC (SWR) branch piece, single (single Y) equal or unequal all as specified and directed.
S&F 110 mm PVC (SWR) branch piece, single (single Y) equal or unequal all as specified and directed.
M&L for disconnecting existing tanks exc 1000 & n.exc 2000 ltr, setting aside( or lowering if reqd) for repair cleaning etc and hoisting if reqd reconnecting and refixing in position all as specified and directed.
Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) of capacity 2000 ltrs hoisted and fixed in position including float valve and tank cover of suitable capacity all as specified and directed.
Dismantling plain or corrugated sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings/chajja all as specified and directed by Engineer-in-Charge.
S&F Aluminum tubular hallow section 25 x 25 mm not exc 900 mm c/c on exceeding columns/beam/ slab to hold cladding and fixing Aluminium composite panel cladding plain metallic of approved colour/ shade to beam/ column/ slab in circular/ rectangular shape including cutting, notching, bending to shape as required jointing with silicon gel of approved colour all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for all as specified and directed.
S&F of structural steel work in tubular/square tube trusses including special shaped washer, gusset/bearing plate using ERW or induction butt welded tubes conforming to I.S.1161-1979 grade St.-240 all as specified and directed.
Taking down carefully copper/aluminum point wiring light/fan/sockets out let/power point complete (fittings such as switches, sockets, ceiling rose, pendent holders, light fittings etc. are to be measured separately) and/or drawing out from existing conduit/batten and making good disturbed surface of walls/floors/ceiling all as specified and directed.
M&L for Point wiring with 1.50 Sqmm single core PVC insulated, unsheathed cable FRLSH, 1100 volts grade with multi stranded copper conductor drawn through and including medium grade, ISI marked, with accessories and incuding provision of 1.50 Sqmm single core PVC insulated, unsheathed cable FRLSH, 1100 volts grade with multi stranded copper conductor green colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including cover plate mild steel sunken box/metal flush box with suitable modular or pressed steel terminal boxes made out of 1.6 mm thick mild steel sheet metal conforming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly and coated with two coats of anti corrosive paint over a coat of red oxide primer both internally and externally including provision of new 3 mm thick plastic laminated sheet top cover for housing the switches, socket outlets, fan regulators etc. with brass screws and brass washers and making good the disturbed surfaces as per existing for one light point controlled by one switch. Note :- Switch, socket and fan regulators to be measured and paid for separately.
All as per Srl item No. 97 here in before but for bell point controlled by one bell push .
All as per Srl item No. 97 here in before but for Exhaust fan point controlled by one bell push .
All as per Srl item No. 97 here in before but for Ceiling fan point controlled by one switch .
All as per Srl item No. 97 here in before but for socket outlet point 5 Amp on same board.
All as per Srl item No. 97 here in before but for socket outlet point 5 Amp on Independent board.
All as per Srl item No. 97 here in before but for one socket point 15 Amp with 2.5 sq mm PVC unseathed FRLSH wire along with 2.5 sq mm green colour wire as earth contuinity conductor connected to common earth dolly all as specified and directed. Note: Earthing wire should also be of 2.5 Sqmm.
All as per Srl item No. 97 here in before but with 4 sqmm cable for 3 pin 15 Amps switch socket outlet (Power point) all as specified and directed. Note: Earthing wire should also be of 4 Sqmm.
S&F modular switch 1 way 10 A module 230/250 volt, AC supply, ISI Marked, with white cover plate with frame and sunken metallic box all as specified and directed.
S&F modular switch 1 way 16 A module 230/250 volt, AC supply, ISI Marked, with white cover plate with frame and sunken metallic box all as specified and directed.
S&F modular sockets 6A, 2/3 pin combined 2 module 230/250 Volts, 50 Hz, AC supply, ISI Marked, with cover plate all as specified and directed.
S&F modular sockets 6A/16A, 2/3 pin combined 2 module 230/250 Volts, 50 Hz , AC supply, ISI Marked, with white cover plate with frame all as specified and directed.
S&F Moduler stepped type electronic fan regulator 120 watt flush type, two module all as specified and directed.
S&F modular bell push 1 way 6 A module 230/250 volt, AC supply, ISI Marked, with cover plate all as specified and directed.
S&F in repairs Modular type AC Box, 4 Module with Socket and 25 Amp SP mini MCB in plastic box enclosure along with cover plate and top all as specified and directed.
S&F call bell ding dong, AC, 230 V, Single pole ISI marked all as specified and directed.
S&F ceiling rose surface bakelite 65x50mm, 3 terminal all as specified and directed.
S&F in repairs 20 watt LED, 6500 K, 4 feet long fixed on pvc square for mounting the fittings and electrically connecting with three single core 23/0.0076. PVC insulated multi strandard copper flexible cable from ceiling rose to light fitting (connector block of lamp fitting) and one for earthing all as specified and directed
S&F LED lights fitting 1x 10W, 220 V, LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete, AC decorative box type, bright white / white type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose pre wired fixed to wall with 2 nos PVC block of suitable size all as specified and directed.
S&F ceiling fans complete with blades, down rods of required size, electronic regulator and accessories, 230 V, 1400 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with scquireel cage induction motor all as specified and directed. Note: Connection should be made neatly using two core flexible cable.
S&F Exhaust fan 230 volt, 300 mm metal body with wooden frame including making all electric connection including cutting of hole on wall and makng good to disturbed surface of wall and outer wooden box for fan fix on wall all as specified and as directed
S&F Exhaust fan 230 volt, 250 mm sweep, plastic body with wooden frame including making all electric connection including cutting of hole on wall and makng good to disturbed surface of wall and outer wooden box for fan fix on wall all as specified and as directed
S&F in repairs MCB Distribution board, 240 volts single pole and neutral, single door, sheet steel, enclosure powder coated with 100 Amps rated busbar with neutral link, 16 ways, fixed on wall duly grouted in solid block wall or on wooden board with electrical connection all as specified and directed.
S&F in repairs MCB DP, 240 Volts, 40 to 63 Amps, 10 kA rupturing capacity 'C' series all as specified and directed.
S&F in repairs MCB, single pole 240 volts 6 to 32 Amps capacity fixed in DB's all as specified and as directed
S&F in repairs MCCB DB 8 way vertical sheet metal enclosure TPN 415 volts, 50 Hz, with IP-43 protection, double door with 200 Amps standard bus bar of suitable size and common neutral link all enclosed in standard sheet flush mounting all as specified and as directed. Note : MCB SP/TPN shall be measured and paid seperately under appropriate items of this schedule . Note : Copper thimble shall be used for connection of cable.
S&F in repairs MCCB TPN, 415 Volts, 63 to 100 Amps, 16 kA rupturing capacity 415 Volts all as specified and directed.
Taking down carefully copper/aluminum submain wiring & cables including all fixtures such as switches, pendant, lamp holder, regulators, switch socket outlet, bulk head fittings, tube light fittings and removing unserviceable materials from site of work and making good disturbed surfaces of walls, floors with cement mortar and white/colour wash to match with existing surfaces all as specified and directed.
M&L Sub main wiring with two run of 10 sq mm stranded copper conductor PVC unsheathed FRLSH wire along with 10 sq mm green colour wire as earth contuinity conductor connected to common earth dolly concealed including PVC FR heavy duty conduit of adequate size (not less than 32 mm dia) for housing the wires for from Pannel / Main DB to house SPN DB all as specified & as directed by engr-in-charge. Note: Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB. Note: Mode of measurement two runs of 10 sqmm cable and one run of 10 sqmm cable with PVC conduite shall be measured as one length.
M&L Sub main wiring with two run single core 4 Sqmm FRLSH copper conductor cable PVC insulated, unsheathed, 1100 V including 20 mm dia concealed ISI marked with all accessories such as Tees, elbows, junction boxes etc, as required fixed on wall alongwith one run of 4 Sqmm single core PVC FRLSH insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board / distribution board and testing on completion. Note: (i) Two runs of 4 sqmm and one run of 10 sqmm cable and one run of PVC conduit shall be measured as one RM.
S&F in repairs/laid in trenches, floors, fix on wall/pole, passing through pipes etc., LT UG cable, 1100 volts grade, PVC/ XLPE insulated, with multistranded aluminium conductors, armoured with galvanised steel wire or tape, gland, lugs of size 50 Sq.mm 3.5core, confirming to IS specifications all as specified and as directed.
S&F in repairs 10 in 1 meter cover Box ( shock proof & weather proof) for housing 10 Nos of single phase energy meters with transparent cover complete including dismantling, connection of existing meter, removal of meter and refixing the same in box and testing on load all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode 60 Cm X 60 Cm X 6 mm buried directly in ground vertically to a depth not less than 2.25 mtr deep below normal ground level with top edge of earth plate at a depth not less than 1.5 m below normal ground level connected to galvanised earth lead wire 4.0 mm dia by means of bolts, check nuts and washers, galvanised steel and protected by GI pipe 15 mm bore light grade & connected to main switch board or main control board as directed including concrete pit in PCC (1:3:6) type C1, precast RCC (1:2:4) type B1 cover slab 30 cm X 30 cmX 5 cm with 10mm dia TMT bars 8 cm C/c both ways and one handle for lifting made out of 8 mm dia TMT bar, funnel, wire mesh, 20mm bore galvanised iron pipe (medium grade) for watering, charcoal or coke and salt in alternative layers, necessary excavation and earth work in any type of soil and including necessary testing on completion all as shown in Electrical Plate No 3 of SSR part -I.
Frends Enterprises (BID ID -3244624)
Panther Facilities (BID ID -3251349)
SRI SAIRAM COUNSTRUCTION (BID ID -3244865)
Unitech Enterprises (BID ID -3241040)
SAHU AND SAHU CO. (BID ID -3244900)
SAHI SAGAR ENTERPRISES (BID ID -3241746)
Shivam Enterprises (BID ID -3244497)
Bright Construction Co (BID ID -3244810)
GANGAJAL (BID ID -3242585)
Bidder Name
Unitech Enterprises
Frends Enterprises
SRI SAIRAM COUNSTRUCTION
SAHU AND SAHU CO.
Panther Facilities
Bright Construction Co
GANGAJAL
Shivam Enterprises
SAHI SAGAR ENTERPRISES
N F ENTERPRISES
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .