Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.8 LAccepted-AOC SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹16.4 L+₹1.2 L (7.96%)Rejected-Finance B 101 SURAJ TOWER MIRA BHAYANDER ROAD OPP SAI PETROL PUMP MIRA ROAD EAST THANE 401107 | MIRA ROAD EAST | THANE | MAHARASHTRA | 401107 | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹16.7 L+₹1.5 L (9.60%)Rejected-Finance | L3 | Rejected-Finance NOT LOWEST |
Tender Value
Refer Docs
EMD Value
₹42,000
Closing Date
25 Mar 2021, 6:00 pmClosed
MAJ VIKAS KUMAR SRIVASTAVA, GE
GARRISON ENGINEER DAMAN TAT RAKSHAK VIHAR DALWADA NANI DAMAN POST DAMAN (UT) PIN 396210
REPAIRS AND MAINTENANCE OF DG SETS AMF PANELS CHANGOVER SWITCHES LT PANEL BOARDS FEEDER PILLAR BOXES APFC PANELS UG CABLES AND CONNECTED WORKS AT ICGAS DAMAN
2021_MES_425683_1
8531/E8
Open Tender
Civil Works
Item Rate
180 days
GARRISON ENGINEER DAMAN
PLEASE REFER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
Yes
GARRISON ENGINEER DAMAN
₹42,000
Yes
30 Apr 2021
25 Feb 2021
27 Mar 2021
25 Feb 2021
25 Mar 2021
11 Mar 2021
Amount
Servicing of diesel engine generator set 15 KVA to 20 KVA of make Kirloskar Engine by carrying out inspection/checking of cylinder head assembly, piston system, piping system,cylinder liners, radiator function and cleaning thoroughly with cleaning agents and drain out the engine oil and filling up new engine oil including replacement of air filter, diesel filter, oil filter, bypass filter, CR element, CR plates, 'O' rings etc and tappet calibration including replacing tapet cover gasket, tightening of all electrical & mechanical parts, greasing to all parts, testing for its working to achieve the requisite satisfactory performance, complete all as specified and directed. Note:- Engine oil will be measured and paid separately under relevant item of schedule as supply only.
Servicing of diesel engine generator set 62.5 KVA of make Kirloskar Engine by carrying out inspection/ checking of cylinder head assembly, piston system, piping system, cylinder liners, radiator function and cleaning thoroughly with cleaning agents and drain out the engine oil and filling up new engine oil including replacement of air filter, diesel filter, oil filter, fan belts, dynamo belts, water pump belts, bypass filter, CR element, CR plates, 'O' rings etc and tappet calibration including replacing tapet cover gasket,tightening of all electrical & mechanical parts, greasing to all parts, testing for its working to achive the requisite satisfactory performance complete all as specified and directed. Note:- Engine oil will be measured and paid separately under relevant item of schedule as supply only.
Servicing of diesel engine generator set 100 KVA of make Kirloskar Engine by carrying out inspection/ checking of cylinder head assembly, piston system, piping system, cylinder liners, radiator function and cleaning thoroughly with cleaning agents and drain out the engine oil and filling up new engine oil including replacement of air filter, diesel filter, oil filter, fan belts, dynamo belts, water pump belts, bypass filter, CR element, CR plates, 'O' rings etc and tappet calibration including replacing tapet cover gasket,tightening of all electrical & mechanical parts, greasing to all parts, testing for its working to achive the requisite satisfactory performance complete all as specified and directed. Note:- Engine oil will be measured and paid separately under relevant item of schedule as supply only.
Servicing of diesel engine generator set 125 KVA of make Cummins Engine by carrying out inspection/ checking of cylinder head assembly, piston system, piping system, cylinder liners, radiator function and cleaning thoroughly with cleaning agents and drain out the engine oil and filling up new engine oil including replacement of air filter, diesel filter, oil filter, fan belts, dynamo belts, water pump belts, bypass filter, CR element, CR plates, 'O' rings etc and tappet calibration including replacing tapet cover gasket, tightening of all electrical & mechanical parts, greasing to all parts, testing for its working to achive the requisite satisfactory performance complete all as specified and directed. Note:- Engine oil will be measured and paid separately under relevant item of schedule as supply only.(AED ALD )/ (Admin Block)
Servicing of diesel engine generator set 160 KVA of make Kirloskar Engine by carrying out inspection/ checking of cylinder head assembly, piston system, piping system,cylinder liners, radiator function and cleaning thoroughly with cleaning agents and drain out the engine oil and filling up new engine oil including replacement of air filter, diesel filter, oil filter, fan belts, dynamo belts, water pump belts, bypass filter, CR element, CR plates, 'O' rings etc and tappet calibration including replacing tapet cover gasket, tightening of all electrical & mechanical parts, greasing to all parts, testing for its working to achive the requisite satisfactory performance complete all as specified and directed. Note:- Engine oil will be measured and paid separately under relevant item of schedule as supply only.
Servicing of diesel engine generator set 250 KVA of make Kirloskar Engine by carrying out inspection/ checking of cylinder head assembly, piston system, piping system,cylinder liners, radiator function and cleaning thoroughly with cleaning agents and drain out the engine oil and filling up new engine oil including replacement of air filter, diesel filter, oil filter, fan belts, dynamo belts, water pump belts, bypass filter, CR element, CR plates, 'O' rings etc and tappet calibration including replacing tapet cover gasket, tightening of all electrical & mechanical parts, greasing to all parts, testing for its working to achive the requisite satisfactory performance complete all as specified and directed. Note:- Engine oil will be measured and paid separately under relevant item of schedule as supply only.
Disconnecting of all rubber hoses and draining out the water from choked radiator assembly from the existing DG set of capacity 15 KVA to 20 KVA and taking down the radiator assembly by unscrewing all mechanical connections from the existing position, opening the top and bottom covers of the radiator assembly, cleaning thoroughly the choked pipe of the radiator by using cleaning agents/caustic soda,cleaning of all the deposited sediments in the pipes/tubes including arresting of leakage by means of soldering/brazing and replacement of clamps, rubber hoses and AVM pads with suitable nuts, bolts and washers etc and fixing back in its original position and testing complete all as specified and directed
Disconnecting of all rubber hoses and draining out the water from choked radiator assembly from the existing DG set of capacity 62.5 KVA to 125 KVA and taking down the radiator assembly by unscrewing all mechanical connections from the existing position, opening the top and bottom covers of the radiator assembly, cleaning thoroughly the choked pipe of the radiator by using cleaning agents/caustic soda,cleaning of all the deposited sediments in the pipes/tubes including arresting of leakage by means of soldering/brazing and replacement of clamps, rubber hoses and AVM pads with suitable nuts, bolts and washers etc and fixing back in its original position and testing complete all as specified and directed
Disconnecting of all rubber hoses and draining out the water from choked radiator assembly from the existing DG set of capacity 160 KVA to 250 KVA and taking down the radiator assembly by unscrewing all mechanical connections from the existing position, opening the top and bottom covers of the radiator assembly, cleaning thoroughly the choked pipe of the radiator by using cleaning agents/caustic soda,cleaning of all the deposited sediments in the pipes/tubes including arresting of leakage by means of soldering/brazing and replacement of clamps, rubber hoses and AVM pads with suitable nuts, bolts and washers etc and fixing back in its original position and testing complete all as specified and directed
Supply and filling inhibitor corrosion (coolant additive concentrate) required for topping up, complete all as specified and directed. Make : Castrol/TVS/Servo.
Supply and toping up of acid mixture suitable for lead acid batteries of 12 volts, complete all as specified and directed.
Supply and toping up of distilled water suitable for lead acid batteries of 12 volts complete all as specified and directed.
Supply and fix in repairs 02 Nos battery cable leads of multistranded copper conductor cable, heavy duty,PVC insulated & sheathed, each of 3 metres long, each of the cable fixed with 1 No terminal socket at one end and at the other end with brass lugs for self starter connection of the DG set, complete all as specified and directed.
Taking down unserviceable battery charger and supply and fix new automatic electronic battery charger, 16 Amps, 24 Volts including making electric connections and to be housed in AMF panel, complete all as specified and directed. Make:- Maha mai / Span /Vinitech/NHP
Taking down unserviceable battery charger and supply and fix new automatic electronic battery charger 10 Amps, 12 Volts, including making electric connections and to be housed in AMF panel complete all as specified and directed. Make : Maha mai / Span /Vinitech/NHP.
Supply and fix 12 Volts, 150 AH, maintenance free battery and connecting to DG set and testing after removing the old unserviceable items complete all as directed. Make:- Amaron/Exide express/AMCO
Supply and fix 12 Volts, 90 AH, maintenance free battery and connecting to DG set and testing after removing the old unserviceable items complete all as directed. Make:- Amaron/Exide express/AMCO
Supply and fix 12 Volts, 180 AH, maintenance free battery and connecting to DG set and testing after removing the old unserviceable items complete all as directed. Make:- Amaron/Exide express/AMCO
Disconnecting of electrical connections from the unserviceable self starter of 15 KVA to 20 KVA DG Set of any make/type and taking down self starter, carrying out repairs,overhauling,servicing of self starter including replacing the unserviceable parts such as bearing,carbon assembly, clutch assembly etc and other parts to make the self starter in serviceable condition, fixing back the self starter in its original position and connecting up all connections and testing complete all as specified and directed.
Disconnecting of electrical connections from the unserviceable self starter of 62.5 KVA to 125 KVA DG Set of any make/type and taking down self starter, carrying out repairs,overhauling,servicing of self starter including replacing the unserviceable parts such as bearing,carbon assembly, clutch assembly etc and other parts to make the self starter in serviceable condition, fixing back the self starter in its original position and connecting up all connections and testing complete all as specified and directed.
Disconnecting of electrical connections from the unserviceable self starter of 160 KVA to 250 KVA DG Set of any make/type and taking down self starter, carrying out repairs,overhauling,servicing of self starter including replacing the unserviceable parts such as bearing,carbon assembly, clutch assembly etc and other parts to make the self starter in serviceable condition, fixing back the self starter in its original position and connecting up all connections and testing complete all as specified and directed. NOTE FOR ITEM NOS. 19 TO 21: Cost of all the materials, repairs and works to make the self starters functional except those considered under item Nos 22 to 24 shall be deemed to be included in the quoted rates of above items.
Supply only armature coil for self starter of DG set 15 KVA to 20 KVA capacity complete all as specified and directed.
Supply only armature coil for self starter of DG set 62.5 KVA to 125 KVA capacity complete all as specified and directed.
Supply only armature coil for self starter of DG set 160 KVA to 250 KVA capacity complete all as specified and directed.
Taking down the unserviceable charging dynamo from DG set of capacity 15 KVA to 20 KVA of any make/model/type and thoroughly checking for carrying out repairs and cleaning with necessary cleaning agent and overhauling, lubricating of the same and replacement of parts such as bearings,bushes, field coil and other minor spares for making the charging dynamo serviceable, reconnecting and fixing back in original position and testing complete all as specified and directed.
Taking down the unserviceable charging dynamo from DG set of capacity 62.5 KVA to 160 KVA of any make/model/type and thoroughly checking for carrying out repairs and cleaning with necessary cleaning agent and overhauling, lubricating of the same and replacement of parts such as bearings,bushes, field coil and other minor spares for making the charging dynamo serviceable, reconnecting and fixing back in original position and testing complete all as specified and directed.
Taking down the unserviceable turbo charger assembly after disconnecting the mechanical connections from DG set of capacity 15 KVA to 20 KVA of any make / type, opening and thoroughly checking for carrying out repairs of the turbo charger assembly and replacing the turbo charger repair kit and minor spares as required including calibrating, servicing for making the turbo charger functional and assembling and fixing back the turbo charger assembly to its original position and testing.
Taking down the unserviceable turbo charger assembly after disconnecting the mechanical connections from DG set of capacity 62.5 KVA to 125 KVA of any make / type, opening and thoroughly checking for carrying out repairs of the turbo charger assembly and replacing the turbo charger repair kit and minor spares as required including calibrating, servicing for making the turbo charger functional and assembling and fixing back the turbo charger assembly to its original position and testing.
Taking down the unserviceable turbo charger assembly after disconnecting the mechanical connections from DG set of capacity 160 KVA to 250KVA of any make / type, opening and thoroughly checking for carrying out repairs of the turbo charger assembly and replacing the turbo charger repair kit and minor spares as required including calibrating, servicing for making the turbo charger functional and assembling and fixing back the turbo charger assembly to its original position and testing.
Taking down the unserviceable water pump of DG set 15 KVA capacity, to 62.5 KVA, servicing and overhauling the water pump including replacing certain spares such as bearing, bushes, gaskets, nuts, bolts and washers etc for making the water pump functional, assembling and fixing back in its original position and testing complete all as specified and directed.
Taking down the unserviceable water pump of DG set 100 KVA capacity, to 250 KVA, servicing and overhauling the water pump including replacing certain spares such as bearing, bushes, gaskets, nuts, bolts and washers etc for making the water pump functional, assembling and fixing back in its original position and testing complete all as specified and directed.
Supply only engine oil of grade 15 W 40 for DG sets of any capacity complete all as specified and directed. Make:- Servo super/Castrol/Volvoline.
Drain out the fuel from the fuel tank of DG set 15 KVA to 62.5 KVA capacity and keeping it in separate container, disconnecting all the fuel lines and other mechanical connections and taking out the fuel tank and cleaning the fuel tank both internally and externally by removing all the accumulated dust/sediments, carry out leakage testing of the tank and welding/brazing, and refixing the tank in its original position,replacing the drain plug and PVC pipe protected with flexible pipe,refilling back the drained out fuel into the diesel tank and providing locking arrangement with 01 No Godrej pad lock, complete all as specified and directed
Drain out the fuel from the fuel tank of DG set 100KVA to 250 KVA capacity and keeping it in separate container, disconnecting all the fuel lines and other mechanical connections and taking out the fuel tank and cleaning the fuel tank both internally and externally by removing all the accumulated dust/sediments, carry out leakage testing of the tank and welding/brazing, and refixing the tank in its original position,replacing the drain plug and PVC pipe protected with flexible pipe,refilling back the drained out fuel into the diesel tank and providing locking arrangement with 01 No Godrej pad lock, complete all as specified and directed
Supply and fix automatic voltage regulator (AVR),415 volts including all spares suitable for existing 125 KVA to 160 KVA DG set and connecting up all electrical connections and testing including removing old unserviceable items, complete all as specified and directed. Make :-Silicon/Stamford/Kirloskar
Supply and fix solenoid switch suitable for existing 100 KVA to 160 KVA DG set, connecting up all electrical/mechanical connections and testing including removing old unserviceable items, complete all as specified and directed. Make:Kirloskar/Cummins
Supply and fix in repair power contactor ML 12, 400 Amps,415 Volts,50 Hz, complete all as specified and directed. Make for I No- 37 to 42 :-L&T/Siemens/GE/CG
Supply and fix in repair power contactor MN 45, 45 Amps,415 Volts,50 Hz, complete all as specified and directed.
Supply and fix in repair power contactor MCX 43, 400 Amps,415 Volts,50 Hz, complete all as specified and directed.
Supply and fix in repair DC Contactor MNO 40,complete all as specified and directed.
Supply and fix in repair power contactor MNX 300, 400 Amps,415 Volts,50 Hz, complete all as specified and directed.
Supply only Digital type electronic auto mains failure controller (AMF)with inbuilt programmer and necessary control wiring, complete all as specified and directed. Make :-L&T/Siemens/Procom
Supply and fix in repair digital type Frequency meter, complete all as specified and directed. Make :-L&T/ AE/IMP
Supply and fix in repair digital type volt meter, complete all as specified and directed. Make :-L&T/ AE/IMP
Supply and fix in repair digital Ampere meter with CTs, complete all as specified and directed. Make :-L&T/ AE/IMP
Disconnecting and dismantling the fuel injunction pump of DG set of capacity upto160 KVA of any make/type, duly isolating the fuel lines,opening and checking the pump, examining the delivery of fuel lines including renewing PT pump, repair kit,servicing of FIP, also including calibration and testing, complete all as specified and directed.
Removing the old unserviceable coupling set with rubber and supply and fix new coupling set with rubber of 20 KVA to 62.5 KVA DG set of any make/type, complete all as specified and directed.
Removing the old unserviceable coupling set with rubber and supply and fix new coupling set with rubber of 100 KVA to 160 KVA DG set of any make/type, complete all as specified and directed.
Removing old unserviceable diesel pipes /oil pipes and supply and fix complete set of new diesel pipes and oil pipes suitable for existing 125 KVA to 160 KVA DG set, complete all as specified and directed.
Supply and fix self starter 24 volts, DC complete with all accessories suitable for existing 160 KVA DG set and including necessary wiring, connections and testing and removing the unserviceable self starter, complete as as specified and directed. Make: LUCAS(TVS)/Autolake/Dewoo
Supply and fix self starter 12 volts, DC complete with all accessories suitable for existing 62.5 KVA to 125 KVA DG set and including necessary wiring, connections and testing and removing the unserviceable self starter, complete as as specified and directed. Make: LUCAS(TVS)/Autolake/Dewoo
Material and labour in repairs for earthing complete with galvanised steel earth plate electrode 600mmX 600mmX 6mm thick buried directly in ground vertically ( earth pit not less than 2.25 metres deep below ground level) with top edge of plate not less than 1.5 metres below ground level, connected to and including galvanised iron strip of size 32 X 6 mm from earth electrode to test point or up to 7.5mtr whichever is less by means of GI bolts, nuts, check nuts and washers all as per electrical plate no 3 of SSR Part-I provision of G I Pipe 40mm bore eight grade for protection of GI strip and GI watering pipe of 20 mm bore medium grade,GI funnel with wire mesh,including char-coal, salt packed all around the earth electrode plate in layers,PCC earth pit chamber 1:3:6 type C1,RCC cover 1:2:4 type B1,excavation,earth work in any strata and returning filling, removal of surplus soil and testing for required value, complete all as specified and directed.
M & L spray painting of silencer of 15 to 250 KVA DG Set capacity with two coat of black/silver synthetic enamel paint over a coat of red oxide primer after cleaning ,scrubbing and filling cavities complete all as specified and directed
Taking out existing underground defective cable of any type and size from the trenches and from any other locations (including taking out of cable covers, pipes etc) complete all as directed.
Supply, laying in trenches/ducts/along wall/through pipes etc, testing and commissioning LT cable, XLPE insulated, galvanized steel strip armoured, 1100Volts grade with multistranded aluminium conductor of cross sectional area 120 sqmm,3.5 core including making cable connections by providing necessary aluminium lugs duly crimped properly and stainless steel glands,nuts,bolts and washers etc complete in all respects, as specified and directed. Note for item No 60 to 65 :- (i) Excavation & Earth work,sand cushioning, cable cover and protection pipe shall be measured and paid separately. (ii) The cable shall be in one length unless otherwise directed by the GE. (iii) Make for item No 60 to 65 :- Havells/polycab/KEI/Finolex/Fort Gloster/Asian cables (RPG)
Supply, laying in trenches/ducts/along wall/through pipes etc, testing and commissioning LT cable, XLPE insulated, galvanized steel strip armoured, 1100Volts grade with multistranded aluminium conductor of cross sectional area 70 sqmm,3.5 core including making cable connections by providing necessary aluminium lugs duly crimped properly and stainless steel glands,nuts,bolts and washers etc complete in all respects, as specified and directed.
Supply, laying in trenches/ducts/along wall/through pipes etc, testing and commissioning LT cable, XLPE insulated, galvanized steel strip armoured, 1100Volts grade with multistranded aluminium conductor of cross sectional area 50 sqmm,3.5 core including making cable connections by providing necessary aluminium lugs duly crimped properly and stainless steel glands,nuts,bolts and washers etc complete in all respects, as specified and directed.
Supply, laying in trenches/ducts/along wall/through pipes etc, testing and commissioning LT cable, XLPE insulated, galvanized steel strip armoured, 1100Volts grade with multistranded aluminium conductor of cross sectional area 35 sqmm,3.5 core including making cable connections by providing necessary aluminium lugs duly crimped properly and stainless steel glands,nuts,bolts and washers etc complete in all respects, as specified and directed.
Supply, laying in trenches/ducts/along wall/through pipes etc, testing and commissioning LT cable, XLPE insulated, galvanized steel strip armoured, 1100Volts grade with multistranded aluminium conductor of cross sectional area 25 sqmm,3.5 core including making cable connections by providing necessary aluminium lugs duly crimped properly and stainless steel glands,nuts,bolts and washers etc complete in all respects, as specified and directed.
Supply, laying in trenches/ducts/along wall/through pipes etc, testing and commissioning LT cable, XLPE insulated, galvanized steel strip armoured, 1100Volts grade with multistranded aluminium conductor of cross sectional area 25 sqmm,02 core including making cable connections by providing necessary aluminium lugs duly crimped properly and stainless steel glands,nuts,bolts and washers etc complete in all respects, as specified and directed.
Material and labour for GI pip 40 mm dia"light grade " complete with all fittings laid in trenches,road/culvert crossing,on wall, floors,on roof,on pole, for cable protection and including removing old unserviceable item complete all as specified and directed. Make :- Jindal/Tata/BST
Material and labour for GI pip 50 mm dia"light grade " complete with all fittings laid in trenches,road/culvert crossing,on wall, floors,on roof,on pole, for cable protection and including removing old unserviceable itemcomplete all as specified and directed. Make :- Jindal/Tata/BST
Material and labour for GI pip 80 mm dia"light grade " complete with all fittings laid in trenches,road/culvert crossing,on wall, floors,on roof,on pole, for cable protection complete all as specified and directed . Make :- Jindal/Tata/BST
Cutting of existing road, concrete/bituminous surface by using of mechanical method of any type complete all as specified and directed Note:-PCC for making good road surfaces shall be measured and paid separately)
Material and labour for PCC (1:3:6) type C2 using(40 mm graded stone aggregate ) for making good distrubed road surfaces including necessary use and waste of form work complete all as specified and directed
Supply and filling in and spreading unwashed river sand for cushioning and covering the under ground cables in trenches and punning to provide required cover complete all as specified in SSR Part-I and as directed. Note: Punned thickess i.e 18 cm shall be measured for paymeny purpose.
Supply and laying unreinforced precast factory made concrete cable cover, class LV, Type -I, flat, size 250mm x 150mm x 40mm, complete all as specified and directed.
Excavation in trenches , not exceeding 1.5 mtr wide and not exc 1.5 mtr depth for laying of cables, pipe lines, protection pipes and foundations etc and getting out in soft loose soil complete all as specified and directed.
Returning filling in soil including spreading leveling watering and well rammimg in layer n exc 25 cm th each layer ,complete all as specified and directed
Removing excavated soil not exc 50 mtr ant depositing where directed at a level not exc 1.5 mtr above the starting point all as specified and directed
supply, installation, testing and commissinoning LT panel board suitable for working on 3 phase ,4 wire ,415 volts, AC ,50Hz indoor type, cubicle, floor mounted, free standing, dust and vermin proof, air ventilation , CPRI approved factory fabricated made out of 2 mm thick CRCA sheet duly powder coated and shall be and as approved by GE. The Panel shall have front and rear opening,locking arrangement, cable alleys, bus bar chamber and switch gear compartment ,hinged door with rubber gasket, bottom cable entry holes for incoming and out going cables, earthing terminals, affix danger notice plate,aluminium bus bar duly covered with heat shrink sleeves colour coaded duly fixed on DMC/SMC insulators, housed in a separate bus bar chamber and control wiring with copper conductor cables of adequate size and length,incoming and outgoing MCCBs shall have extended bus bar links and mounted on 50x50x5mm size MS angle iron frame duly painted including PCC 1:2:4 Type B1 (using 20 mm graded stone aggregate ) in foundation design subject to approved of GE to sent the site requirement complete all as specified and directed including comprising of following :- (a) On-load change over switch 250 Amps,4Pole,415 V,50Hz front handle operated,open execution type -01 No (b) MCCB 100 Amps,FP, 16 KA,415 volts,50Hz-1 No (c) MCCB 63 Amps,FP,10 KA,415 volts,50Hz-4 Nos (d) MCB 63 Amps,FP,10 KA,415 volts,50Hz-3 Nos (e) MCB 40 Amps,FP,10 KA,415 volts,50Hz-5 Nos (f) Digital voltmeter,with VSS , Digital, Ammeter,with CTs & ASS-01 set (g) LED phase indication lamps RYB-01 set (h) Aluminium bus bar TPN 400 Amps rating -01 set
supply, installation, testing and commissinoning LT panel board suitable for working on 3 phase ,4 wire ,415 volts, AC ,50Hz ,outdoor type, cubicle, floor mounted, free standing, dust and vermin proof, air ventilation made out of 3.15 mm thick CRCA sheet and suitable sized angle iron and flat duly powder coated and shall be CPRI approved and as approved by GE.Panel shall have front and rear opening,locking arrangement, cable alleys, bus bar chamber and switch gear compartment ,hinged door with rubber gasket, bottom cable entry holes for incoming and out going cables, earthing terminals, affix danger notice plate,aluminium bus bar duly covered with heat shrink sleeves colour coaded duly fixed on DMC/SMC insulators, housed in a separate bus bar chamber and control wiring with copper conductor cables of adequate size and length,incoming and outgoing MCCBs shall have extended bus bar links and civil work/PCC foundation as per site requirement and removing of old unserviceable LT panel from existing location after disconnecting of existing cables complete all as specified and directed including comprising of following :- (a) MCCB 160 Amps,FP, 25 KA,415 volts,50Hz-01 No (b) MCCB 100Amps,FP,16 KA,415 volts,50Hz-2 Nos (c) MCCB 32 Amps,FP,10KA,415 volts,50Hz-2 Nos (d) MCB 40 Amps,DP,10 KA,415 volts,50Hz-8 Nos (e) Digital voltmeter,with VSS -01 set,Digital, Ammeter,with CTs & ASS-01 set (f) LED phase indication lamps RYB-01 set (g) Aluminium bus bar TPN 300 Amps rating -01 set
Supply and fix tamper proof static energy meter in polycarbonate body with LCD display of accuracy class 1.0as per IS13779, single phase ISI marked 240 V, AC ,50 Hz of rating 10 to60 Amps including making connection and testing complete all as specified and directed .Make :- HPL cat No 13200100000C1 or equivalent in L&T/secure
Supply and fix tamper proof static energy meter in polycarbonate body with LCD display of accuracy class 1.0as per IS13779, Three phase ISI marked 415 V, AC ,50 Hz of rating 10 to60 Amps including making connection and testing complete all as specified and directed .Make :- HPL/ L&T/secure
Supply and fix analogue time switch(Daily time switch) suitable for outdoor ,power contactor 63 Amps ML-2 type,3Phase,415 volts and MCB TPN 63 Amps,10 KA 'C' series , including bus bar of suitable capacity with arrangement of auto/mannual control switch duly prewired and all accessories same shall be enclosed in and including sheet metal enclosure of 3.2 mm thick CRCA sheet of adequate size with powder coated, fixing arrangements on floor including powder coated painting and mounted on 50x50x6mm MS angle iron frame duly painting and shall be any CPRI approved manufacturer subject to approval of GE and including removing old unserviceable item complete all as specified and directed. Make of timer :- Legrand/L&T/GE Make of Contactor:- Siemens/L&T/ABB/Schneider/GE Make of MCB:- Legrand/L&T/Siemens/Havells
Supply and fixing in repairs of capacitor bank 15KVAR, MPP type, 415Volts, 50Hz in existing panel boards and connecting of existing cables with proper lugs and testing including removing old unserviceable items, complete all as specified and directed.
Supply and fixing in repairs of capacitor bank 10KVAR, MPP type, 415volts, 50Hz in existing panel boards and connecting of existing cables with proper lugs and testing including removing old unserviceable items, complete all as specified and directed.
Supply and fixing in repairs of capacitor bank 5KVAR, MPP type, 415volts, 50Hz in existing panel boards and connecting of existing cables with proper lugs and testing including removing old unserviceable items, complete all as specified and directed. Make for item No 81 to 83 - Epcos/L&T/Schnieder
Supply and fix rigid non-metallic PVC conduit 25 mm dia medium grade including conduit accessories for encasing the cable from looping box to street light fittings on PCC poles/on wall surfaces as per site requirement with neccessary base saddles all as specified and directed. Make:- Finolex/Prince/Supreme/Precision/Dutron/Tirupati
Supply and fixing cable tray 200mm wide x 25mm deep, hot dip galvanised with standard slot pattern manufactured from CRCA sheet 2.00 mm thick duly pre-treated with hot dip galvanising in seven tank process, perforated type including provision of fixing arrangement, nuts & bolts etc for proper securing to walls/beams or suspended from ceiling, complete all as specified and directed Schedule of credit :-46105
Saviour Security Systems
Radha Engineering Services
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .