Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.6 LAccepted-AOC | L1 | Accepted-AOC LOWEST AMOUNT QUOTED | |
| 2 | L2₹11.1 L+₹52,075.21 (4.90%)Rejected-Finance | L2 | Rejected-Finance SECOND LOWEST AMONT QUOTED | |
| 3 | L3₹11.3 L+₹65,799.40 (6.20%)Rejected-Finance | L3 | Rejected-Finance THIRD LOWEST AMOUNT QUOTED | |
| 4 | Rejected-Technical | - | Rejected-Technical not qualified in all parameters | |
| 5 | Rejected-Technical S2 SGS SILVER OAK APARTMENT 1ST A CROSS SNEHA COLONEY CHIKKALASANDRA BANGALORE 560061 BANGALORE KARNATAKA 560061 | BENGALURU URBAN | KARNATAKA | 560061 | - | Rejected-Technical not qualified in all parameters |
Tender Value
₹14.3 L
EMD Value
₹29,000
Closing Date
18 Feb 2020, 9:30 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
DIGP GC AVADI
THE DIGP GROUP CENTRE CRPF AVADI CHENNAI 600065
WATER PROOFING USING ELASTOMERIC MEMBRANE PU FOR RECREATION ROOM OF SIZE 14.7 X 14.80M AT RTC AVADI AND RECTT MESS 1,2 AND HQR MESS OF EACH SIZE 14.70 X 14.80M AT ATC AVADI CRPF CHENNAI-65
2020_CRPF_543390_1
B.V.1/2019-20-GCA-BLDG
Open Tender
Civil Works
Works
25 days
RTC AVADI, ATC AVADI CRPF CHENNAI
AS PER TENDER DOCUMENTS
2 documents required · 2 mandatory
₹200
DIGP GC CRPF AVADI
₹29,000
4 Feb 2021
11 Feb 2020
19 Feb 2020
11 Feb 2020
18 Feb 2020
11 Feb 2020
11 Feb 2020 - 18 Feb 2020
180 days
Amount
Water proofing treatment using Elastomeric membrane (pu)
Demolishing Brick tile covering in terracing including stacking of serveceable material and disposal of unserveceable material within 50metres lead.
Dismantling old plaster, wall tile,dado or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
Providing and laying water proofing treatment on roof slabs by applying 3 coat including Priming coat of Elastomeric Poly urethane (PU)liquid membrane complies with the requirement as laid out in ASTM D 6083-97 a. which consisting of following operations : a) after surface preparation apply first layer of Bonding coat ( SDR )with cement 1:1 ratio and before drying applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 followed with a screed concrete Max. 40mm thick as levelling coarse using 12mm coarse aggregate in 1:2:4 mix , mixed with water proofing compound and levelled . This will be allowed to cure for 12 hrs. Apply Final coating followed by PU primer coat 50% dilution with water apply through brush only and allow to dry 4-6hrs. Apply undiluted PU coating over the primer coat using brush and allow to dry for 4 -6 hrs. Apply Undiluted PU coating as top coat using brush/roller . The works shall be carried out all complete as per specification and the direction of the Engineer -in-charge.
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in -charge. Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix)
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand)
Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge
12 mm cement plaster finished with a floating coat of neat cement of mix : 1:4 (1 cement: 4 fine sand)
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Shoe (Plain) 110 mm Shoe
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete 110 mm
12 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand)
S RAMESH
B MURUGESAN
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .