| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹7.3 LAccepted-Finance GIJJROLI AGRA ROAD HATHRAS UTTAR PRADESH 204101 INDIA | HATHRAS | HATHRAS | UTTAR PRADESH | 204101 | ₹7.3 L | 1 | Accepted-Finance Lowest Rate. |
| 2 | 2₹8.6 LRejected-Finance NAGLA SADAK HATHRAS | HATHRAS | HATHRAS | UTTAR PRADESH | ₹8.6 L | 2 | Rejected-Finance Higher Rate. |
| 3 | Rejected-Technical | - | - | Rejected-Technical Technical Bid Found Not ok. |
| 4 | Rejected-Technical | - | - | Rejected-Technical Technical Bid Found Not ok. |
| 5 | Rejected-Technical 428 SURAJ PALACE C A ROAD GANDHIBAG NAGPUR MAHARASHTRA 440002 | NAGPUR | MAHARASHTRA | 440002 | - | - | Rejected-Technical Technical Bid Found Not ok. |
| Sl No | Description | Qty | Unit | SUMIT ENGINEERING L1 | R.N. ELECTRICAL WORKS L2 |
|---|---|---|---|---|---|
| 1.00Supply of 11 KV Line Material as per relevant ISS | |||||
| 2.00 | Stone Pad 300x300x75 | 72 | No | 120 ₹8,640 | 100 ₹7,200 |
| 3.00 | MS Top Channel 100x50x2240 | 4 | No | 650 ₹2,600 | 1,800 ₹7,200 |
| 4.00 | MS Top Channel 125x65x2240 | 8 | No | 650 ₹5,200 | 2,200 ₹17,600 |
| 5.00 | Cross Bracing Angle | 4 | Set | 3,500 ₹14,000 | 900 ₹3,600 |
| 6.00 | Clamp with Nut & Bolts | 54 | No | 350 ₹18,900 | 350 ₹18,900 |
| 7.00 | Barbed Wire | 248 | Kg | 150 ₹37,200 | 250 ₹62,000 |
| 8.00 | Danger Board with Clamp | 64 | No | 150 ₹9,600 | 100 ₹6,400 |
| 9.00 | F Bracket | 68 | No | 15 ₹1,020 | 280 ₹19,040 |
| 10.00 | PG Clamp | 24 | No | 250 ₹6,000 | 100 ₹2,400 |
Tender Value
₹9.5 L
EMD Value
₹9,500
Closing Date
22 Dec 2025, 12:00 pmClosed
SE EDC Etah
Vidhyut Colony, Aruna Nagar, Railway Road, Etah.
Work for Shifting of 11 KV and LT lines and other electrical equipments in Pahra-Rudain Marg Chaudikaran under EDD-Pilua, Etah on semi turnkey basis (Deposit Scheme)
2025_DVVNL_1088679_5
18/2025-26/EDC ETAH
Open Tender
Electrical Works
District-Etah
As per Tender Documents
2 documents required · 2 mandatory
₹1,180
DVVNL
₹9,500
31 Dec 2025
15 Dec 2025
22 Dec 2025
15 Dec 2025
22 Dec 2025
15 Dec 2025
Amount
Supply of 11 KV Line Material as per relevant ISS
Stone Pad 300x300x75
MS Top Channel 100x50x2240
MS Top Channel 125x65x2240
Cross Bracing Angle
Clamp with Nut & Bolts
Barbed Wire
Danger Board with Clamp
F Bracket
PG Clamp
Number Plate
MS T off Channel with Clamp
Nut Boalts
Guarding Angle with Clamp
Red Oxide Paints
Alluminium Paints
Dropper Channel 100x50x2028 mm
Double Pole Clamp
Clamp for LT T off Channel with N&B
Alluminium Tape
Supply of LT Line Material as per relevant ISS
Stone Pad
3 Ph Distribution Clamp
Pricing Connector
I Hook with Suspension Complete
Dead End Clamp
Erection work of 11 KV Line
Safe carriage of line material from store center Etah to direct pit site in distance range 0 to 60 Km. including loading and unloading at both side.
Safe carriage of 8.5 Mtr Long PCC pole from store center Etah to direct pit site in distance range 0 to 60 Km. including loading and unloading at both side.
Safe carriage of 11 Mtr Long ST pole from store center Etah to direct pit site in distance range 0 to 60 Km. including loading and unloading at both side.
Erection of 8.5 mtr PCC Pole as single support including fixing of all HT/LT accessories etc. complet, pole should be grouted properly as per DVVNL/RESPO norms.
Erection of 11 mtr ST Pole as single support including fixing of all HT/LT accessories etc. complet, pole should be grouted properly as per DVVNL/RESPO norms.
Erection of 8.5 mtr PCC Pole as Double/Section Pole including fixing of all HT/LT accessories etc. complete with TPMO, pole should be grouted properly as per DVVNL/RESPO norms.
Erection of 11 mtr ST Pole as Double/Section Pole including fixing of all HT/LT accessories etc. complete with TPMO, pole should be grouted properly as per DVVNL/RESPO norms.
Laying, sagging stringing, binding, jumpering & fixing of all accessories etc of following conductor on the newly/old erected pole as per RESPO manual and as per direction of supervising engineer. It includes the cost of labour, T & P, carrier etc required for proper completion of work.
(i) ACSR Weseal Conductor
Stone Pad 300x300x75
Barbed Wire
Danger Board with Clamp
PG Clamp
Stay Set Complete
Number Plate
Guarding Angle with Clamp
Red Oxide Paints
Alluminium Paints
Alluminium Tape
Earthing Complete
GI Wire 6 SWG
GI Wire 8 SWG
AL LT XLPE Cable 3.5x70 sq mm
Erection Work of LT Line
Safe carriage of line material from store center Etah to direct pit site in distance range 0 to 60 Km. including loading and unloading at both side.
Safe carriage of 8.5 Mtr Long PCC pole from store center Etah to direct pit site in distance range 0 to 60 Km. including loading and unloading at both side.
Safe carriage of following AB Cable from store center Etah to direct pit site in distance range 0 to 60 Km. including loading and unloading at both side.
(i) LT AB Cable 1x120 sq mm
(ii) LT AB Cable 1x95 sq mm
Erection of 8.5 mtr PCC Pole as single support including fixing of all HT/LT accessories etc. complet, pole should be grouted properly as per DVVNL/RESPO norms.
Laying, sagging stringing, binding, jumpering & fixing of all accessories etc of following cable on the newly/old erected pole as per RESPO manual and as per direction of supervising engineer. It includes the cost of labour, T & P, carrier etc required for proper completion of work.
(i) LT AB Cable 3x120 sq mm
(ii) LT AB Cable 3x95 sq mm
Stone Pad
Pricing Connector
I Hook with Suspension Complete
Dead End Clamp
3 Phase Distribution Box with Clamp
Earthing Complete
Stay Set Complete
Dismentalling of following LT AB Cable stacking of proper place.
(i) LT AB cable (3x120) sq. mm
(ii) LT AB cable (3x95) sq. mm
Safe carriage of dismantilled material (LT AB Cable) from the pit side to the store distance 0 to 60 Km. with loading & unloading at both ends and proper stacking in store.
Dismentalling of ST Pole stacking of proper place.
Dismentalling of old ACSR Weseal Conductor stacking of proper place.
Safe carriage of dismantilled material from the pit side to the store distance 0 to 60 Km. with loading & unloading at both ends and proper stacking in store.
Safe Carriage of Dismantiled ST Pole from the pit side to store in distance 0 to 60 km with loading and unloading at both ends proper stacking in store.
R.N. ELECTRICAL WORKS (BID ID -5762453)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.51 MB
Upload18.rar
Tender Documents • 2.97 MB
BOQ_2025035.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid