Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
Tender Value
₹7.3 L
EMD Value
₹7,500
Closing Date
25 Sept 2021, 4:50 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE EUDC-I, LESA
Office of the SE EUDC-I, LESA
30/EUDC(I)/2021-22
2021_MVVNL_620821_2
30/EUDC(I)/2021-22
Open Tender
Electrical Works
Fixed-rate
90 days
in the area under EUDD Rajbhawan
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
Central bank of India
₹7,500
28 Sept 2021
20 Sept 2021
25 Sept 2021
20 Sept 2021
25 Sept 2021
20 Sept 2021
180 days
Amount
Safe carriage, loading-unloading with proper stacking of following material from ESC-Daliganj to Work Site/JE -Dump Store –
(a) 11KV 3X120 SQ MM XLPE CABLE
(b) 11KV END TERMINATION O/DOOR & I/DOOR 3X120 SQ MM
(c) 3.5X240 SQ MM LT PVC CABLE
Double circuit cable laying in normal soil by digging of trench 1050 mm deep, 750 mm wide including supply of required material as fine sand, 1st class bricks, stone slab. Inter axial spacing between the two cable should be in between 0.25 m to 0.40m. the two cables should be seprated by a partition of single bricks (All the material required for laying will be supplied by the contractor except 11 KV XLPE cable)
Double circuit cable laying through GI pipe 6’’ dia with supply of GI pipe in 1 Mtr. deep (All the material required for laying will be supplied by the contractor except 11 KV XLPE cable)
High Pressure testing of 11 KV XLPE cable. Testing equipment will be arranged by the contractor.
Placement of 11/0.4 KV T/Fs installation, commissioning of 400/100 KVA T/F jumpering with the system (All the required matrial for above job shall be provided by contractor except T/Fs)
Chemical Earthing system with outer pipe diameter 50mm, inner Strip 40x6, length 3000 mm. galvanization up to 200 micro, earthing pipe with crystalline conductive mixture filled inside the pipe with anti-corrosion & high conductive along with 50 Kg(As per required) of BFC which should be capable to reducing the soil resistively with good moisture retaining capacity.(Specification of chemical earthing and drawing is hereby enclosed). All material shall by supply by the contractor.
Laying of Double circuit LT PVC Cable 3.5x240 sq mm single circuit in 900 mm deep, 500 mm wide including supply of required material as fine sand, 1st class bricks, stone slab (Except LT PVC cable)
Construction of T/F plinth of size 2x2x1.5 m on a padding 0.25M deep in ground 1:5:10 cemend sand and brick ballast on the top of padding brick work Ist class brick of 0.95 mtr hight & 0.35 mtr wall will be constructed.Rest wall should be 0.23 mtr thick.brick work in ratio 1:4 cement & cores Sand in the hollow portion the sand should be fiilled from the ground level up to 15 centimeter below from the top of wall,Cement,sand & brick Ballasts should be filled up to 15 centimeter.Two no. of channel 100x50 in length 1500mm will be grouded.0.35 CM.RCC will be done with cores sand,cement and stone ballast in the ratio of 1:2:4.The t/fs plinth should be plastered on all sides 12mm thick in ratio 1:6 by cement and cores sand. (All the material will be arranged by the contractor .)
Construction of retaining wall, fabrication & erection of Wire mesh fencing around Transformer and Distribution Pillar Box with retaining wall & 1 no. gate with locking arrangement made of MS Angle iron of size 50x50x6 mm jointed with nuts and bolts. The panel must be supported with MS Flat of size 50x6 mm. Wiremesh of size 10 SWG rectangle type, its painting as per norms of RESSPO. (All the material will be arranged by the contractor at his own cost).
Construction of massonary type Distribution Pillar box with first class brick ballast cement, coarse sand, local sand, brick ballast and MS Round bar of 10 mm dia including Straight MS Angle 50X50X6X750 mm- (All the material will be arranged by the contractor).
Suppy & fixing of henless fuse unit 500 amp 650 volts
Hoisting, winding and jumpering of of LT cable size 3.5x240 sq mm between LT distribution box/fuse unit & constructed overhead line with proper lugging and clamping
Providing earthing strip size 50x6mm and connecting from MS earting rod to fuse unit/tronsformer body/neutral earthing(Earthing rod & earthing strip arranged by contractor).
Making of circuits
Taping of line
Supply & Fixing of CU L-Piece
Supply of copper stripe of size 50x50x6 mm
Carriage of T/F from old side to new site of 11/0.4 KV 400 KVA T/F & 100 KVA T/F
Hoisting of 11 KV Line
All taxess aplicale shall be paid time to time extra.
M/S R P ENTERPRISES
P.S. ENTERPRISES
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .