Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.2 LAccepted-Finance | L1 | Accepted-Finance L1 | |
| 2 | L2₹9.3 L+₹2,952 (0.32%)Rejected-Finance | L2 | Rejected-Finance L2 |
Tender Value
₹9.4 L
EMD Value
₹19,700
Closing Date
23 Aug 2022, 11:00 amClosed
Ex. Engineer(Elect.)/CNZ
C-Block, Defence Colony, New Delhi 110024
Improvement of E.I and Fans and Rewiring, Sumersible Pump and Street light Pole in sarai kale khan Cremation Ground in ward no. 56-S under CNZ.
2022_SDMC_125794_1
EE(Elect.)/CNZ/2022-23/25-02
Open Tender
Electrical Works
Item Rate
90 days
C-Block, Defence Colony, New Delhi
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
₹19,700
3 Feb 2024
16 Aug 2022
23 Aug 2022
16 Aug 2022
23 Aug 2022
16 Aug 2022
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. Group C
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
Supplying and fixing PVC batten/ angle holder including connections etc. as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.(a)2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required(b) 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. a) 3x2.5
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.(a) 3 x 4 sq. mm
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. A). 8 Module (125mmX125mm)
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. B). 12 Module (200 mmX150 mm)
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. A) 20 mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required b) 25 mm
Supplying and fixing following modular switch/ socket on theexisting modular plate & switch box including connections but excluding modular plate etc. as required (a) 5/6 A switch
Supplying and fixing suitable size GI box with modular plateand cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 modular switch, connections etc. as required.
Supplying and fixing suitable size GI box with modular plateand cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 5/6 &15/16A modular switch, connections etc. as required.
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc.as required.(a) Up to 450 mm sweep
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) a)6 way, Double door
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) B)12 way, Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.(a) Single pole
Supplying and fixing following rating ,double pole,24o volt,isolator in the existing MCB DB complete with connections,testing and commissioning etc. as required.(a) a) 63 amps
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 125 A, 36kA, FPMCCB
Supply of 9 watt LED retrifit lamp suitable for B22 holder
SITC of single phase monoblock pumpset complete with all accessories workable of 240 volts 50 Hz AC supply 1.0 HP (0.75 KW) single phase pumpset head from 6-34 meter suction and delivery 25x25mm.
Supply of 250 mm ( 10 inch) sweep 1250 rpm exhaust fan Fresh Air type complete with shutter,blade etc as required
Supply of 15" ( 380 mm )sweep 1400 rpm exhaust fan heavy duty complete with shutter,blade etc as required
S.I.T.C. of 1200 mm sweep, BEE 5 star rated Ceiling fan with Brush less direct current (BLDC) motor, class of insulation: B, 3 Nos.blades, 30 cm long downrod, 2 Nos canopies, shackle kit, safety rope, copper winding, Power factor not less then 0.9, service value (CMM/W) minimum 6.85, Air delivery minimum 215 6.85,350 rpm (tolerance as per IS :374-2019, THD less than 10% remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, earthing etc, complete as reqd.
S/I/T/C of LED Tube Type luminiare 20 Watt rating complete with polycarbonate housing Batten integrated electronic driver prewired with high efficient LEDs with the following: (a) Total System Wattage 20 Watt +/- 5%. (b) Luminous Efficieny lumens/watt >= 95 (c ) Power Factor>= 0.95
Supply, installation, testing and commissioning of cubical type control panel board for single phase & three phase submersible pumping set of following rating complete with contactor, relay, MCB,Condenser, voltmeter, ammeter, and indication lamp etc including connections etc. as reqd. 1.5 HP ( Single Phase)
Supply, installation, testing and commissioning of cubical type control panel board for single phase & three phase submersible pumping set of following rating complete with contactor, relay, MCB,Condenser, voltmeter, ammeter, and indication lamp etc including connections etc. as reqd.( 3 HP ( Single Phase)
Supply,lowering , testing and commissioning of following capacity vertical type, multistage, totally enclosed, water filled, deep well submersible pumping set complete i/c connections etc as reqd.(a) Single Phase 3.0 HP Having discharge of 100 LPM (Approx.) at 52 M Head
Providing and Fixing following sizes of PVC insulated & PVC sheathed copper conductor 3 core submersible cable conforming to IS .647/1990 etc. as reqd.(a) 3x2.5 sq.mm
Supply,lowering and fixing following size of GI pipe (M-class) i/c cutting threading on both sides etc ISI marked etc as requried.(a) 40 mm (Nominal Bore)
S & L following sizes of steel flexible rope suitable for holding submersible p/set including clips etc as reqd. (a)6mm dia steel rope.
SITC of pillar box box size 900 mm x 450 mm x250 mm suitable for mounting incomer of 250 amp MCCB/main switch 4 pole and energy meter 3 phase complete with eleethoypic grade aluminium bus bar of size 25mmx 19mm mounted on galvanized M.S. body powder coated pilferage proof SMC door duly welded with S.S with rain com size 40mmx 40mmx 5mm x600mm height in cutting 300mm height below ground and covered with shade proof SMC sheet of 3mm as required.
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required
P/F 6 SWG dia GI wire on surface or in recess for loop earthing along with existing surface / recess conduit/submain wiring cable as reqd.
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Up to 35 sqmm
Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size in the existingRCC/HUME/METAL pipe as required. Up to 35 sqmm
Supply of XLPE insulated and PVC sheathed Al. conductor armoured cable 1.1 KV grade confirming to IS 7098 as required. (a) 2 x6 sqmm
S/L of following size DWC HDPE Pipe ISI marked along with all accessories like socket ,bend ,couplers etc.conforming to IS 14930 ,part II complete with fitting and cutting ,jointing etc .direct in ground (75 cm below ground level )including excavation and refilling the trench but excluding sand cushioning and protective covering etc, complete as required (a)63mm dia (OD-63mm ID -51mm nominal ).
Fabrication,supply & errection of following size flange mounted hot dip galvanized octagonal pole made from HT steel plate, window with flash cover with full vertical window cover at appropriate hight from the base plate on existing cement concrete pedestal as required. i/c supplying and fixing of 6 mm thick laminated mounted sheet inside the window mounted on and i/c providing and welding 3 nos. G.I strips 4 mm thick of suitable length and having suitable size tapped holes as reqd., terminal block suitable for 25 sqmm conductor-4 nos & shorting links on DIN channel i/c pdg and fixing DIN channel of suitable lenth,6 amps SP MCB "c" characteristics,earth stud,cable support clamp suitable for upto 4x25 sqmm cable. Logo/Name of manufacturer shall be embossed on the pole. Galvanization as per relevant IS.( a) 5.o mtr. hight,3 mm thick,bottom dia of 130 mm & top dia of 70 mm, base plate of size 225 mm x 225 mm x 12 mm thick.
Providing and laying in position M25 grade reinforced cement concrete foundation of size 450 mm (L)x450 mm wide and 1000 deep i/c excavation of earth, providing cutting, bending and placing in position, reinforcement of cold twisted bars of 12 mm dia- 960 mm long (approx)-8 nos . and reinforcement of cold twisted bars of 8 mm dia 1400 mm (approx) - 6 nos. (with 150 mm spacing) as required with supplying and positioning of 4 no. foundation bolts of size 16 mm dia ,600 mm long, J type i/c 2 nos. template anchor plates of size 225 mm X 225 mm X 3 mm and providing 63mm dia DCW, HDPE for cable entry and exit as required for 5 mtr pole.
Fabrication, supplying and fixing class B galvanised single overhang arm bracket made out of 250 mm long galvanized top tube with cap and 1000 mm long 32 mm dia galvanised pipe with tightening bolts complete as required.
Fabrication,Supplying,Installation,testing,Commissioning of 12 mts.high mast System with its accessories ,Mast shaft shall be in one section , hot dip galvanized 4mm thick (Single dip ) inside and out sides and suitable for wind velocity as per IS 875 part3 .There shall be in longitudinal seam weld per section and No circufrential weld. It should also included accessories for High Mast head frame ,2 point suspension system with steel wire rope 5mm dia. (7/19construction) single drum winch ,galvanized lantern carriage arrangement suitable for 4/6 Nos. flood light luminaries luminaries symmitrically and its control gears boxes and lighting finial ,the mast shall have integral type manual tool mounted at the base compartment of its raising and lowering operation with foundation bolts and Anchor plate and control panel housing suitable RCC (1:2:4) shallow foundation of size 1m(L)X1m (W)X2m deep i/c excavation of earth i/c excavation of earth, providing cutting, bending and placing in position, rewinforcement of cold twisted bars of 12 mm dia -2100 mm long (approx.) - 16 nos.and reinforcement of cold twisted bar of 8 mm dia - 3700 mm (approx.) - 13 nos. (with 150 mm spacing) as required with positioning of 4 nos foundation bolts and providing DWC HDPE pipe for cable entry & exit as required for high mast considering. The safe soil bearing capacity at site as 10T/sqm at 2mts. Depth with all material i/c, 4Nos S.P MCB, 63Amp.DPIsolator etc as reqd. Logo/Name of manufacturer shall be embossed on the pole. galvanized as per relevant IS.
Amit Elevator
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .