| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.9 CrAccepted-AOC OPP AIR FORCE STATION VPO SORANA DISTT SAHARANPUR UP PIN 247 232 | SAHARANPUR | UTTAR PRADESH | 247232 | ₹5.9 Cr | L1 | Accepted-AOC LOWEST BIDDER |
| 2 | L2₹7.3 Cr+₹1.4 Cr (23.6%)Rejected-Finance | ₹7.3 Cr+₹1.4 Cr (23.6%) | L2 | Rejected-Finance NOT LOWEST |
| 3 | L3₹8.1 Cr+₹2.1 Cr (35.8%)Rejected-Finance 121 MODEL TOWN AMBALA CITY HARYANA 134003 | AMBALA CITY | AMBALA | HARYANA | 134003 | ₹8.1 Cr+₹2.1 Cr (35.8%) | L3 | Rejected-Finance NOT LOWEST |
| 4 | L4₹11.0 Cr+₹5.0 Cr (84.9%)Rejected-Finance | ₹11.0 Cr+₹5.0 Cr (84.9%) | L4 | Rejected-Finance NOT LOWEST |
Tender Value
₹6.4 Cr
EMD Value
₹6.4 Cr
Closing Date
4 May 2022, 6:00 pmClosed
CE (AF) WAC PALAM
HQ CE (AF) WAC PALAM DELHI CANTT
PROVN OF CHILDREN SCHOOL AT AF STN SARSAWA
2022_MES_507866_1
CEWAC/SAR/T-31/2021-22
Open Tender
Civil Works
Lump-sum
547 days
GE (AF) SARSAWA
AS PER NOTICE OF TENDER
8 documents required · 8 mandatory
₹3,000
GE (AF) SARSAWA
₹6.4 Cr
Yes
10 Jun 2022
22 Feb 2022
11 May 2022
22 Feb 2022
4 May 2022
18 Apr 2022
22 Feb 2022 - 9 Mar 2022
Amount
SCHEDULE `A' PART - I (Building Works) is not prepriced by MES and prepriced rates indicates 0.0 under column 6 signified this fact only.
Construction of Air Force School Building (Double story) with permanent specification , complete all as specified and shown on drawings.
Construction of Parking shed for 20 scooters with permanent specification, complete all as specified and shown on drawings.
Construction of Parking shed for 84 Cycles with permanent specification, complete all as specified and shown on drawings.
Construction of Santry box with permanent, complete all as specified and shown on drawings.
Construction of septic tank, including excavation of any type of soil, foundation in PCC 1:2:4, brick work with fly ash bricks in CM 1:4, RCC slab covers including RCC precast manhole cover having 6mm plate embedded al around/fibre reinfoced cover with angle iron frame vent shaft and sludge chambers etc for 100 users, complete all as specified and shown on drawings.
Construction of Soakage well including excavation in any type of soil, foundation in PCC 1:2:4, walls in honey combed masonary with top ring of M25 concrete including intercepting chamber and screen chamber made of brick masonaryin CM 1:4, RCC cover slab in M25/SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 3M dia x 6 M effective depth, complete all as specified and shown on drawings.
NOTE: Schedule ‘A’ Part II to X below are Prepriced by MES.
Lump sum price worked out by the Contractor for “EXCAVATION AND EARTH WORK” as listed in Schedule ‘A’ Part II
Lump sum price worked out by the Contractor for “INTERNAL ELECTRIFICATION"” as listed in Schedule ‘A’ Part III
Lump sum price worked out by the Contractor for “INTERNAL WATER SUPPLY" as listed in Schedule ‘A’ Part IV
Lump sum price worked out by the Contractor for "SEWAGE DISPOSAL ” as listed in Schedule ‘A’ Part V
Lump sum price worked out by the Contractor for “AREA DRAINAGE” as listed in Schedule ‘A’ Part VI
Lump sum price worked out by the Contractor for “ROAD, PATH AND CULVERT” as listed in Schedule ‘A’ Part VII
Lump sum price worked out by the Contractor for “COMPOUND WALL AND GATE” as listed in Schedule ‘A’ Part VIII
Lump sum price worked out by the Contractor for “ EXTERNAL WATER SUPPLY ” as listed in Schedule ‘A’ Part IX
Lump sum price worked out by the Contractor for “EXTERNAL ELECTRIFICATION” as listed in Schedule ‘A’ Part-X
SCHEDULE `A' PART - XI MISC B/R & E/M ITEMS is not prepriced by MES and prepriced rates indicates 0.0 under column 6 signified this fact only.
INTERNAL ELECTRICFICATION
S&F LED light fitting 1 x 10 Watt, 220V, AC, box type with driver, holder connecting up with three core flexible copper conductor cable 0.5 sqmm from Ceiling rose complete all as specified and directed.
S&F LED light fitting 1 x 40 Watt, 220V, AC, box type with driver, holder connecting up with three core flexible copper conductor cable 0.5 sqmm from ceiling rose complete all as specified and directed.
S & F LED security 35 watt, input 110 to 220 volts as per IP 65 luminaries comprising of rectangular shape , high pressure die cast aluminium housing, with weather proof gaskets for tamp and driver compartment with Gl pipe 25 mm dia light grade bend to shape including necessary fixing arrangement complete all as specified and directed.
S&F MCB TPN 63 Amps, B curve type 10 KA ,415 Volts complete all as specified and directed.
S&F MCB SPN 40 Amps to 63 Amps, B curve type 10 KA, 240 Volts complete all as specified and directed.
S&F MCB SP 6 to 32 Amps, B Curve type 10 KA breaking capacity 240 Volts complete all as specified and directed.
S&F MCB SP 40 Amps: B Curve type 10 KA breaking capacity 240 Volts complete all as specified and directed.
EXTERNAL ELECTRIC SUPPLY
Supply and Installation commissioning & testing 11 KV Compact Sub Station with and including 1 No, 11 KV/630 Amps VCB, 1 No transformer 100 KVA, 11/0.433 KV & associated LT Distribution system & suitable , self contained power pack complete all as described & specified below- 11 kV 630Amps 21kA for 3 sec. Vacuum Circuit Breakers with series trip, self powered microprocessor based numerical over current and Earth Fault (IDMT+lnst) relay protection. Interconnection between HT Switchgear and transformer shall be using 1CX3X95 sqmm Aluminium armorured XLPE Cable. IDMT relay with communication port-l No Protection CT 5/1 Amps, 2.5VA, 5P10 - 3 nos Manometer - 01 No Operating Handle - 01 Nos
The Enclosure shall have IP-56 degree of protection for HT & LT switchgear compartment & IP23 degree of protection for Transformer compartment. The enclosure exterior shall be Polyuratne painted (Colour Light Gray & D.A. Gray ). Each compartment will be provided with the door and pad locking arrangement. The Compartment illumination lamp with door operated switch shall be provided for MV and LV compartment. Separate switch operated bulket lamp. INTERCONNECTION AND EARTHING Interconnection Between HT switchgear & Transformer using suitable size 4P Al bus bar trucking & Interconnection between Transformer & LT switchgear using Aluminium Busbars. Internal earthing connections by using 50 x 6 Gl strips including Transformer Neutral earthing.- 01 job Note:- (a) Package Sub-Station is outdoor plinth mounted type. Erection, Commissioning and Civil work for package substation shall be as per OEM specifications and rate is inclusive for the same. (b) Package Substation complete with the internal interconnections shall deemed to be included in the rate quoted. Note :1. Compact Substation shall be installed at a height of 1000mm above the ground level. 2. Compact substation shall be having IP-56 3. Chain link fencing shall be provided all around the CSS. It shall be provided minimum 750mm from each side of Compact substation of height of 1.8 mts. Chain link fencing to be measured and paid for separately.
Supply and fixing of 20W LED Street light with system Lumen Effcacy > 100 Lm/W operating Voltage between 140-270 VAC, Driver will have cut off at >300 VAC, IP66 protection, power factor more than 0.95%, Over all electrical efficiency more than 90%, connecting with PVC copper cable of size 1.5x3Sqmm as IS 10322 lat all as specified and directed.
S&F Non metallic Junction box made out of thermoplastic size not less than 28 cm x l7cmx l0cm hinged with lockable arrangement including aluminium bus bar 2-pole capacity 6 Amp with provision of tapping incoming and outgoing cable connection with gland box of suitable size and fixing on pole/grouting in PCC muff complete all as specified and directed.
Supply & fix Decorative LED Post Top Lantern light fitting with max, system wattage 40 watt and system lumen output not less than 80 lumen per watt, total system lumens not less than 3200 lumens, PF not less than 0.90, circular canopy and dear acrylic cover for 360 degree indirect, uniform, glare free light distribution complete all as specified and directed by Engr-in-charge.
Supply & fix cable route marker of size 100 x 25 x 3 mm size incl round shape plate which engraved LT/HT cable complete with PCC and earthwork all specified and directed.
S&F multi stranded copper cable PVC insulated unsheathed 1100 volts grade of size 2.5 sqmm 3 core, drawing through tubular pole upto light fitting and making connections and testing for functioning of light fittings complete all as specified and as directed.
S&F busbar chamber four pole toally enclosed metal clad with porcelain insulater and colour coated tinned copper busbar of capacity 200 Amps fixed/grouted in brick wall complete all as specified and as directed.
M&L for provision of single arm pole top mounted bracket of suitable size for mounting street light fitting 1.5 mtr long complete all as specified and as directed.
M&L for Construction of Chain link on fencing post of size 40 x 40 x 6 mm of height 1.80 mtr at 2 mtr c/c around platform including excavation and earth work 30 cm embedded portion of angle iron in PCC 1:2:4 type B2 of size 60 x 60 x 60 cm. Chain link fencing of height 1.8 mtr made out of Gl wire not less than 3mm and pitch not more than 75mm. Angle iron gate using 40 x 40 x 6 m angle iron of size 2 x 1.5 m with vertical flat 25 x 6 mm @ 10 com c/c including hanging & locking arrangement. 15 mm thick plaster in CM 1:6 on brick masonary platform. All exposed surfaces of steel, work shall be given two coats of synthetic enamel paint over a coat of red oxide primer. Stair case of brick masonary for easy access to the plate form.
EXTERNAL WATER SUPPLY
M&L for construction of fly ash brick masonery valve pit of size 90x90x90 cm (internal dimension) with MS top coer of 3mm thick sheet, fixed on frame made out of angle iron 40x40x6mm thick with locking arrangement including two coats of synthetic enamel paint over a coat of red oxide primer to MS sheet internally and externally & iron surface, brick work in cement mortar 1:4,15mm thick plastering in cement mortar 1:4 (internally & externally) 150 thick plain cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate for base, 100mm thick PCC 1:2:4 type B-l using 20mm graded mechanically crushed stone aggregate for coping two coats of white wash internally after preparation the surface complete all as specified and as directed.
SUMMER APPLIEANCE
S&F desert cooler, electric driven copper wounded motor (single phase), having nominal air flow capacity minimum 4500 Cum per hour, 1400Rmp, 230Volts, 50Hz, three speed regulator with metallic blade and mild steel body, duly painted with synthetic anti corrosive oven cured paint, submersible pum (IS 11951:1987) 40 watts incl wood wool pad (set of 3) of proper thickness and 2.50 sqmm three core copper wire with connecting top plug compelte as per IS (3315:1994) all as specified and as directed.
Supply and fix desert cooler electric driven 230 Volt (Single phase), having nominal air flow capacity of 5000 Cum per hour (or nearest size) Steel body complete all as specified and as directed..
Supplying & fixing of Angle iron 40x40x5mm size suitable for desert cooler including holes in wall & PCC including welding work all as specified and as directed.
ROAD, PATH AND HARDSTANDING
M&L for GSBC (sub base) 200 mm thick consolidated thickness in two layers 100 as per table 400-1 morth specification, spread, rolled with 8-10 ton capacity vibratory roller and consolidated to required gradient and camber in two layers complete all as specified and as directed.
M&L for 150 mm thick (compacted thickness) Wet mix macadum (WMM) using stone crushed aggregate of grading required as per table 400-11 of yellow book of mors laid in two layers 75 mm each with mechanical means and rolling with 8-10 tonne power roller over compacted sub base complete all as specified and directed. (Note-mix will be prepared in mixing plant of suitable capacity)
M&L for road line painting 100 mm wide with golden yellow, white thermostatic compound with reflectorised glass beads on bitumen road providing and laying of hot applied thermostatic compound 2.5 mm thick including reflectorised glass beads @ 250 gm per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRS 35 the finished surface to be levelled, uniform and free streaks and holes in addition where arrow of letters to be provided thermostatic compound may be machine sprayed the colour of compound with traffic diversion arrangement if required as per MORT&H clause 803.4 complete all as specified and directed.
VEE SONS BUILDERS PVT LTD
J.D.Builders
A K BANSAL AND CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .