Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.4 LAccepted-AOC | L1 | Accepted-AOC Lowest tenderer | |
| 2 | L2₹18.7 L+₹3.3 L (21.3%)Rejected-Finance C O SECTOR 02 HOUSING COLONY CHANNI HIMMAT JAMMU J K PIN 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | L2 | Rejected-Finance Other than lowest tenderer | |
| 3 | L3₹21.3 L+₹5.9 L (38.6%)Rejected-Finance | L3 | Rejected-Finance Other than lowest tenderer |
Tender Value
Refer Docs
EMD Value
₹60,000
Closing Date
28 Aug 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE NAGROTA
GE NAGROTA PIN 901208 C/O 56 APO
DAY TO DAY COMPLAINTS OF EXTERNAL ELECTRIC AT VARIOUS LOCATION UNDER GE NAGROTA
2021_MES_462498_2
GEN-34/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
NAGROTA
Class D and above and category b (I)
8 documents required · 8 mandatory
₹500
GE NAGROTA
₹60,000
Yes
13 Oct 2021
28 Jul 2021
30 Aug 2021
28 Jul 2021
28 Aug 2021
12 Aug 2021
60 days
Amount
Repair/Rectification of all electric fault , LT underground cable by using cable fault locator on site , rectifying the fault by using the cable , cable joint , lugs including excavation, returning filling, removal of excavated material, testing after the rectification of fault, complete all as specified and directed by Eng in Charge. Note : (a) All T&P /Cable fault Locator /Stationaries and labour team required comprising of Nos of Trained Electrician & Helpers will be provided by the contractor daily, as Required. (b) Rep of contractor will present in complaint cell & responsible for receiving & attending the complaint for round the clock . in absence of Rep of contractor penal recovery as decided by the GE shall be imposed on cotractor (c) Cost of minor stores such as screw, clamps, insulation tapes, nuts, bolts , nail of required size etc shall be deemed to included in the above quoted rate. However major items such as MCCBs , cables, Joints, Changeover etc shall be measured and paid seperately in respective items. (d) complaints where complete replacement of items required shall be measured and paid under relevent items. (e) If contractor fails to rectify the complaint within 24 hrs after which recovery of Rs 1000.00 per complaint will be panalised.
S & F XLPE cable, insulated,armoured, heavy duty electric cable with aluminium conductor,1100 volts grade, cross-sectional area 240 Sqmm 3.5 core including taking down old cable, complete all as specified and directed.
All as per ser item No. 02.00 here in above but cross sectional area 185 sqmm 3.5 core
All as per ser item No. 02.00 here in above but cross sectional area 120 sqmm 3.5 core
All as per ser item No. 02.00 here in above but cross sectional area 95 sqmm 3.5 core
All as per ser item No. 02.00 here in above but cross sectional area 70 sqmm 3.5 core
All as per ser item No. 02.00 here in above but cross sectional area 35 sqmm 3.5 core
All as per ser item No. 02.00 here in above but cross sectional area 25 sqmm 4 core
All as per ser item No. 02.00 here in above but cross sectional area 16 sqmm 4 core
S&F heat shrinkable straight through cable jointing kit 1.1 KV LT 4core XLPE cable cross sectional area 10 to 16 sqmm, complete all as specified and directed
All as per ser item No. 10.00 here in above but cross sectional area 25 to 50 sqmm
All as per ser item No. 10.00 here in above but cross sectional area 70 to 150 sqmm
All as per ser item No. 10.00 here in above but cross sectional area 185 to 240 sqmm
Repair/Rectification of all electric fault occured in LT Panel , Cable, MCCBs, rectifying the fault by Replacing the cable , cable joint , lugs , MCCBs including dressing of Cable ,Change Over Switch ,Bressing and Jointing of DOORs , hooks, reconnecting to LT Panel and testing after the rectification of fault, complete all as specified and directed by Eng in Charge. Note : (a) All T&P /Stationries and labour team required comprising of Nos of Trained Electrician & Helpers will be provided by the contractor daily, as Required. (b) Rep of contractor will present in complaint cell & responsible for receiving & attending the complaint for round the clock . in absence of Rep of contractor penal recovery as decided by the GE shall be imposed on cotractor (c) Cost of minor stores such as screw, clamps, insulation tapes, nuts, bolts , nail of required size etc shall be deemed including in the above quoted rate. However major items such as MCCBs , cables, Joints, Changeover etc shall be measured and paid seperately in respective itmes. (d) complaints where complete replacement of items required shall be measured and paid under relevent items. (e) If contractor fails to rectify the complaint within 24 hrs after which recovery of Rs 1000.00 per complaint will be panalised.
Supply and fixing in replacement MCCB 630 amps capacity, four pole, 415 volt with breaking cap 36 KA, complete all as specified and directed.
Supply and fixing in replacement MCCB 400 amps capacity, four pole 415 volt with breaking cap 36 KA, complete all as specified and directed.
Supply and fixing in replacement MCCB 250 Amps, four pole, 415 volt with breaking cap 36 KA, complete all as specified and directed.
Supply and fixing in replacement MCCB 200 Amps, four pole, 415 volt with breaking cap 25 KA, complete all as specified and directed.
Supply and fixing in replacement MCCB 100 Amps, four pole, 415 volt with breaking cap 25 KA, complete all as specified and directed.
Supply and fixing in replacement MCCB 63 amps capacity, four pole, 415 volt with breaking cap 16 KA, complete all as specified and directed.
Supply and fixing in replacement MCCB 400 amps capacity, three pole, 415 volt with breaking cap 36 KA, complete all as specified and directed.
Supply and fixing in replacement MCCB 250 amps capacity, three pole, 415 volt with breaking cap 36 KA, complete all as specified and directed.
Supply and fixing in replacement MCCB 200 amps capacity, three pole, 415 volt with breaking cap 25 KA, complete all as specified and directed.
Supply and fixing in replacement MCCB 100 amps capacity, three pole, 415 volt with breaking cap 25 KA, complete all as specified and directed.
Supply and fixing in replacement MCCB 63 amps capacity, three pole, 415 volt with breaking cap 16 KA, complete all as specified and directed.
S&F in repair MCB TPN 32 Amp 415 volts 50 Hz AC 10 KA with necessary lugs includng taking down existing MCB complete all as specified and directed
S&F in repair MCB TPN 63 Amp 415 volts 50 Hz AC 10 KA with necessary lugs includng taking down existing MCB complete all as specified and directed
S&F in repair MCB SPN 32 Amp 415 volts 50 Hz AC 10 KA with necessary lugs includng taking down existing MCB complete all as specified and directed
S&F in repair MCB SPN 40 to 63 Amp 415 volts 50 Hz AC 10 KA with necessary lugs includng taking down existing MCB complete all as specified and directed
S & F Change over switch off load type with enclosure, conforming IS 13947 part I & III 415V, 4 pole of rating 63 amps, including taking out old unserviceable one, complete all as specified and directed by Engineer-in-charge.
All as per ser item No. 30.00 here in above but capacity 100/125 amps
All as per ser item No. 30.00 here in above but capacity 200 amps
All as per ser item No. 30.00 here in above but capacity 400 amps
Supply and fixing in replacement voltmeter of size 96 x 96 mm, complete all as specified and directed.
Supply and fixing in replacement amp meter of size 96 x 96 mm, complete all as specified and directed.
Tape wound LT CTs of ration 100/5 Amp at 5 VA CT for class 1.0 seconday current upto capacity of 500 Amp of Primary current, complete all as specified and directed by Eng in Charge.
M&L for cleaning, preparing of Lt panel of any size and painting with two coats of synthetic enamel paint , complete all as specified and directed.
S & F 400 sqmm aluminium lugs of any type/shape
S & F 300 sqmm aluminium lugs of any type/shape
S & F 240 sqmm aluminium lugs of any type/shape
S & F 150 sqmm aluminium lugs of any type/shape
S & F 120 sqmm aluminium lugs of any type/shape
S & F 95 sqmm aluminium lugs of any type/shape
S & F 70 sqmm aluminium lugs of any type/shape
S & F 50 sqmm aluminium lugs of any type/shape
S & F 35 sqmm aluminium lugs of any type/shape
S & F 25 sqmm aluminium lugs of any type/shape
S & F 16 sqmm aluminium lugs of any type/shape
S&F GI nuts, bolts, screws, washers of required size complete all as specified and directed
S&F 20 mm stainless steel double compression cable glands complete all as specified and directed
All as per ser item No. 50 here in above but 25-40 mm
All as per ser item No. 50 here in above but 50-80 mm
Labour only for repair/rectification/re-stringing restraching of all electric fault occured in OH ACSR conductor laid over, over head LT line on steel / PCC poles after removing binding from insulator and rewinding the conductor with insulator including providing spacer and new binding wire jumpering provide with after restraining and removing unavoidable sags in the line and trimming of tree and branches on LT line for minimum clearance, complete all as specified and directed.
Supply only PVC line spacer of superior quality suitable for four line of ACSR over head lines, complete all as specified and directed.
Supply only PVC line spacer of superior quality suitable for three line of ACSR over head lines, complete all as specified and directed.
Cross arm, bracings, supports, clamps and chequered steel back plates, angle iron equal size or any size fabricated from steel section including nuts, bolts, washers, welding bending cold or hot drilling holes for bolts in any shape or size for cover for cable duct any size and holding of two pole strucures, GOD, street light GI bracket, junction boxes and fabrication of anti climbing devices, other works etc as indicated or directed and duly painted with synthetic enamel aluminium/smooke grey paint over a coat of primer fixed "as in repairs", complete all as specified and directed .
M&L for Aluminium conductor, steel reinforced of any size on LT Poles including straining,binding with insulators with Al/copper binding wire with insulators as in over head conductors, providing PVC Sleeves for jumper fixed as in repairs, complete all as specified and directed.
S & F in repairs Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100 mm height, 65 mm dia for 1100 volts grade, complete all as specified and directed.
S & F in repairs Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150 mm height, 150 mm dia for 11000 volts grade, complete all as specified and directed.
S & F in repairs Shackle type porcelain, vitreous, white, brown or green insulator 1100 volts working pressure, 100mm high and 115mm dia with and including galvanised mild steel staps washers insulator bolts 12mm dia, washers and nuts, complete all as specified and directed.
Cleaning, preparing and painting with two coats of silver synthetic enamel paint on 9/11m poles, cross arms, MS channels, angle iron, frame work bracing including numbering of pole and writing of feeder name with black enemelled paint from stencil, complete all as specified and directed.
S&F in repairs switch air break gang operated (Swing out expulsion ruse insulators), tripple pole mechnical operated from ground level mounted on insulator and steel frame (15 insulators type) out door type suitable for vertical installation single break provided with locking arrangement consisting of MS channel HT post top insulator with drop out fuses operating rod 20mm dia GI medium grade pipe worked from ground level confirming of IS 1818 of 1972 and continuous current rating upto 200 amp and volt 11 KV, complete all as specified and directed.
Supply and fixing of male contact/moving contact blade 200 amp of Air Break switches complet with nuts and Bolts of capacity 11 KV, complete all as specified and directed by Eng In Charge.
Supply and fixing of female contact/Fix contact Jaw 200 amp of Air Break switches complet with nuts and Bolts of capacity 11 KV, complete all as specified and directed by Eng In Charge.
Supply and fixing of tinned copper flexible jumper 200/400 amp with MS jumper carrier for Air Break switches complete with nuts and Bolts of capacity 11 KV, complete all as specified and directed.
Cleaning of MES electric supply insatllation/Campus/Four pole structure by surface dressing or trimming of natural ground to remove small un equilities not exc 15 cm deep (incuding removing vegetation including shrubs /brushwood /undergrowth etc) carrying away the rubbish to a distance of not exc 50 m away, complete all as specified and directed.
S&F in repairs12 mm dia and 300 mm long air termination, single pointed aluminium rod , complete all as specified and directed.
S&F in repairs 12 mm dia and 300 mm long air termination, single pointed copper rod , complete all as specified and directed.
Supply and fixing in repair of aluminium strip 25 x 3.15 mm with saddles and fixing screws etc. for roof conductors and down conductors above ground, complete all as specified and directed.
Supply and fixing in repair of copper strip 20 x 3.15 mm with saddles and fixing screws etc. for roof conductors and down conductors above ground, complete all as specified and directed.
Supply and fixing in repairs earth continuity conductor or main earthing lead fixed to walls on batten or recess or chesses or buried in ground or fixed to poles or any other indicated situation for loop earthing with using 32 x 6 mm dia GI strip, complete all as specified and directed.
Supply & Fixing 20 mm bore dia steel water tubing galvanised iron (light grade) with all fittings such as bends, elbows, tees, unions, nipples, short pieces etc and fixed complete to walls and ceilings or laid in floors, complete all as specified and directed.
M & L for PCC 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) as foundation filling and mass concreate in foundation of pole/stays, complete all as specified and directed.
M&L for PCC 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) as in foundation, filling and mass concrete in foundatin of pole/stay, complete all as specified and as directed.
M&L for PCC 1:2:4 type B-1, (using 20 mm graded crushed stone aggregate) as in copying above ground level around the plole, complete all as specified and directed.
Supply and erection in truely vertical position steel tubular swaged poles, type 410 SP-55 (11.00 meters) with 300 mm x 300 mm x 6 mm mild steel base plate continuously welded to poles, finial taper plug, bolts, nuts and screws all as specified including factory painted with two coats of black bituminous paint internally through out and externally for embedded portion and making 30 cms wide strips with yellow and black paint at alternatively upto 1.50 metre height and applying two coats of aluminium paint over a coat of red oxide primer on remaining exposed surface after erection including taking down of old unserviceable existing pole any size any type ,complete all as specified and directed.
M&L for stay assembly galvanised iron complete with accessories stay rod 20 mm dia, 180cm long with two nuts, stay bow 14mm dia and 38cm long with stay plate 300x300x6mm thick mild steel stay thimble and required length including binding to insulator stay bow and stay clamp galvanised iron stay strand wire 7/4mm dia, complete all as specified and shown in EP plate No 1 of SSR part-I, complete all as specified and directed.
Earthing complete with galvanised mild steel earth plate electrode 60cmx60cmx6mm thick, burried directly in ground preferably in vertical position (Earth pit not less than 2.25 mtr below ground level) with top edge of the earth plate not less than 1.5 mtr below normal ground level, connected to galvanised iron strip 25×4 mm by means of bolts, nuts, check nuts and washers of galvanised iron including pit of PCC (1:2:4) type B-1, pre cast RCC cover slab of size 550x550x75mm, XPM reinforced not less than 1.60Kg/Sqm with suitable built in handle made from 12mm dia MS round bar, excavation and earth work in any type of soil, 20mm dia bore medium grade galvanised iron water tubing fixed with cast iron funnel and wire mesh at one end, 15mm bore light grade galvanised iron protection pipe for earth lead wire upto 5m length, charcol, common salt complete all as shown in electric plate No 5 of SSR 2009 Part I connected to equipment, testing on completion, complete all as specified and directed.
Deduction to be made from BOQ for schedule of credit (Sch 'A' Part - II) Amount of Rs. 1,05,485.00 during AOC Note:- Tenderers shall not quote for this Schedule
MAMTA ENTERPRISES
M/S MANJIT SINGH AND SONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .