| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.2 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹17.2 L+₹3.1 L (21.6%)Rejected-Finance 1ST FLOOR HAQUE MARKET H B ROAD FANCY BAZAR KAMRUP METROPOLITAN ASSAM 781001 | KAMRUP METRO | ASSAM | 781001 | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹17.5 L+₹3.3 L (23.1%)Rejected-Finance G 4 106 107 1ST FLOOR SECTOR 11 ROHINI NEW DELHI 110085 | NORTH WEST | DELHI | 110085 | L3 | Rejected-Finance Not being L1 | |
| 4 | L4₹18.0 L+₹3.8 L (26.7%)Rejected-Finance | L4 | Rejected-Finance Not being L1 | |
| 5 | L5₹18.3 L+₹4.1 L (29.3%)Rejected-Finance A 86 MANISH MARG NEMI NAGAR VAISHALI NAGAR JAIPUR JAIPUR JAIPUR RAJASTHAN 302021 | JAIPUR | RAJASTHAN | 302021 | L5 | Rejected-Finance Not being L1 |
Tender Value
₹19.6 L
EMD Value
₹39,170
Closing Date
19 Feb 2022, 6:00 pmClosed
AGM(E-E), Dibrugarh Airport.
O/o AGM(E-E), Dibrugarh Airport.
Replacement of Hi-wall Split AC Units/ Tower AC Units/ Passenger Boarding Bridge AC Units at various locations in Dibrugarh Airport
2022_AAI_104938_1
AAI/DIB/ENGG-E/AC Units/2021-22
Open Tender
Electrical Works
Item Rate
120 days
Dibrugarh Airport
Please refer Tender documents.
11 documents required · 11 mandatory
₹1,180
₹39,170
5 May 2022
9 Feb 2022
21 Feb 2022
9 Feb 2022
19 Feb 2022
9 Feb 2022
9 Feb 2022 - 15 Feb 2022
Amount
Supply of following capacities Hi Wall split AC unit (5-star rating - Inverter type), Copper Condensing unit (Outdoor Unit) with fan and High Energy Efficiency Ratio compressor, with cordless remote controller and operating on Single phase AC supply, and all its accessories etc., as per manufacturer standard and as per specifications, complete as required. The supply of unit shall include initial charge of R32 gas etc. complete as required.
Supply of 3.0TR Tower AC unit (with latest BEE star rating available if any) Copper Condensing unit (Outdoor Unit) with fan and High Energy Efficiency Ratio compressor, with cordless remote controller and operating on Single/Three phase AC supply, and all its accessories etc., as per manufacturer standard and as per specifications, complete as required. The supply of unit shall include initial charge of R32 gas etc. complete as required.
Supply of Round Flow, Ceiling mounted Cassette AC unit, Inverter type, Copper Condensing Outdoor Unit (Toshiba model, Indoor: RAV SM1104UT-E, Oudoor: RAV SM1104AT-E or equivalent model of capacity ≥ 2.8TR) as per manufacturer standard, operating on Single phase AC supply, and all its accessories etc. and as per specifications, complete as required, to install in the tunnel area of Passenger Boarding Bridge. The supply of unit shall include initial charge of gas etc.
Supply of One way, Ceiling mounted Cassette AC unit, Inverter type, Copper Condensing Outdoor Unit (Toshiba model, Indoor: RAV SM802XT-E, Oudoor: RAV SM803AT-E or equivalent model of capacity ≥ 1.9TR) as per manufacturer standard, operating on Single phase AC supply, and all its accessories etc. and as per specifications, complete as required, to install at rotunda area of Passenger Boarding Bridge. The supply of unit shall include initial charge of gas etc.
ITC of following capacities Hi Wall split AC unit/Tower AC unit by making required support structure as per site requirement i/c balancing of Liquid & Gas, Gas charging the system with refrigerent, if any extra gas required due to increase in length of Copper piping, including covering the Copper piping with nitrile rubber insulation with suitable size PVC pipe Lifting / Shifting of Outdoor & Indoor units upto site location etc., as per specifications, complete as required.
Up to 2.0 TR
Above 2.0 TR and upto 4.0 TR
ITC of following capacities Passenger Boarding Bridges AC units by making required support structure as per site requirement i/c balancing of Liquid & Gas, Gas charging the system with refrigerent, if any extra gas required due to increase in length of Copper piping, including covering the Copper piping with nitrile rubber insulation with suitable size PVC pipe, Lifting / Shifting of Outdoor & Indoor units upto site location etc., as per specifications, complete as required. (Note: Rate to be quoted including necessary support/space modifications required based on the model supplied at S.No. 3 & 4)
Up to 2.0 TR
Above 2.0 TR and upto 4.0 TR
Supply, Laying and connecting of OEM recommended size copper refrigerent Piping(Liquid and Gas) with Nitrile Rubber insulation of thickness not less than 13mm, Power & control cable and with all other accessories suitable for Hi Wall split AC units/Tower AC units including covering the Copper piping with suitable size casing capping/PVC pipe etc. as per specifications, complete as required. (Length of Liquid and gas line will be measured as single measurement).
Supply and laying of 6mm thick, PVC pipe of suitable size for condensate water drain for additional requirement for AC units i/c necessary clamps, screws, supports etc. as per specifications, complete as required.
Dismantling of existing Split AC units/Tower AC units/Window AC units (Indoor and Outdoor) units and shifting to Electrical Store as required.
SHARMA TRADE AGENCY
AQUATICS ENIGINEERS
Sagar Traders
LIFE STYLE INTERIORS
STAR REFRIGERATION SALES AND SERVICE
RS COOLING APPLIANCES
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .