| 3 | Not Admitted-Fee/PreQual/Technical FIRST FOOR SCF 1 SECTOR 17 FARIDABAD FARIDABAD FARIDABAD HARYANA 121002 | FARIDABAD | HARYANA | 121002 | Not Admitted-Fee/PreQual/Technical EMD/Fee not received |
Tender Value
₹55.3 L
EMD Value
₹1.1 L
Closing Date
4 Dec 2020, 3:00 pmClosed
Executive Engineer (Elect)
T.E. Building KBN, Room No -19, Kidwai Bhawan MTNL, New Delhi-110001
AC Maintenance work
2020_MTNL_599094_1
EE(E)KBN/2020-21/25-11-2020/68
Open Tender
Electrical Works
Item Rate
730 days
Kidwai Bhawan
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,180
MTNL Delhi
₹1.1 L
11 Dec 2020
25 Nov 2020
5 Dec 2020
25 Nov 2020
4 Dec 2020
25 Nov 2020
Amount
All-inclusive Comprehensive Maintenance of window /split/ multi-split/ ductable/ package type air-conditioning units as per details given in relevant sections, monitoring and maintaining environmental conditions of conditioned area by deploying the required manpower including specialized manpower & by arranging required tools & plants etc. to maintain the environmental conditions of the conditioned-area up-to required standards. Note: Rates should be quoted for 24 months period. a) 7.5TR to 11TR PACKAGE TYPE AIR COOLED A.C. UNITS
b) 11TR DUCTABLE TYPE AIR COOLED A.C UNITS
c) 7.5TR to 9.0TR DUCTABLE TYPE AIR COOLED A.C UNITS
d) 5.0TR to 5.5TR DUCTABLE TYPE AIR COOLED A.C UNITS
Synthetic fibre media washable filters with frame (Efficiency 90% down to 20 microns) for 5TR to 5.5TR ductable a.c. unit.
Synthetic fibre media washable filters with frame (Efficiency 90% down to 20 microns) for 7.5TR to 11.0TR ductable a.c. unit.
Synthetic fibre media washable filters with frame (Efficiency 90% down to 20 microns) for 7.5TR to 11TR package a.c. unit
Supply, installation, testing and commissioning of 5TR/5.5TR condensor coil for ductable a.c.units including flushing of whole system and pressure testing with nitrogen gas, vaccumzing & charging with proper refrigerant complete as required. (Note: Additional quantity of refrigerant, if any, supplied by the agency shall be measured separately)
Supply, installation, testing and commissioning of 7.5TR condensor coil for ductable a.c.units including flushing of whole system and pressure testing with nitrogen gas, vaccumzing & charging with proper refrigerant complete as required. (Note: Additional quantity of refrigerant, if any, supplied by the agency shall be measured separately)
Supply, installation, testing and commissioning of evaporator coil of 5TR/5.5TR ductable AC unit (single/twin circuit) including flushing of whole system and pressure testing with nitrogen gas, vaccumzing & & charging with proper refrigerant complete as required. (Note: Additional quantity of refrigerant, if any, supplied by the agency shall be measured separately)
Supply, installation, testing and commissioning of evaporator coil of 7.5TR to 9TR ductable AC unit (single/twin circuit) including flushing of whole system and pressure testing with nitrogen gas, vaccumzing & & charging with proper refrigerant complete as required. (Note: Additional quantity of refrigerant, if any, supplied by the agency shall be measured separately)
Supply, installation, testing and commissioning of evaporator coil of 11TR ductable AC unit (single/twin circuit) including flushing of whole system and pressure testing with nitrogen gas, vaccumzing & & charging with proper refrigerant complete as required. (Note: Additional quantity of refrigerant, if any, supplied by the agency shall be measured separately)
Supply, installation, testing and commissioning of 5TR/5.5TR condenser coil for package a.c.units including flushing of whole system and pressure testing with nitrogen gas, vaccumzing & charging with proper refrigerant complete as required. (Note: Additional quantity of refrigerant, if any, supplied by the agency shall be measured separately)
Supply, installation, testing and commissioning evaporator coil for 11.0TR Package AC unit (twin circuit) with the help of brazing set including flushing of whole system and pressure testing with nitrogen gas, vaccumizing & commissioning of AC unit complete as required. (Note: Additional quantity of refrigerant, if any, supplied by the agency shall be measured separately)
Supply and charging of R-22/R-410a/R-407c gas for top up of refrigerant in the AC units complete as required. (Note: This item shall be measured and paid only in case of replacement of coils wherever executed)
V.K Enterprises
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .