| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.6 LAccepted-AOC 218 D 1A JYANTIPUR NEAR SHYAM PIPE FACTORY SULEM SARAI PRAYAGRAJ UP | PRAYAGRAJ | PRAYAGRAJ | UP | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹7.5 L+₹63,145.50 (9.21%)Rejected-Finance | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹8.0 L+₹1.1 L (16.5%)Rejected-Finance | L3 | Rejected-Finance Not being L1 | |
| 4 | L4₹8.0 L+₹1.1 L (16.5%)Rejected-Finance 2 2 BLOCK B MAYUR RESIDENCY MISRAPUR KURSI ROAD LUCKNOW 226026 UP | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226026 | L4 | Rejected-Finance Not being L1 | |
| 5 | L5₹8.2 L+₹1.4 L (19.7%)Rejected-Finance | L5 | Rejected-Finance Not being L1 |
| Sl No | Description | Qty | Unit | Khan Brothers L3 | M/s RAM LAKHAN GUPTA L1 | His And Her Enterprises L2 | M/s R.S. Enterprises L5 | Ajanta Motor Store L6 | FUTURE Inc. L4 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches, not exceeding 1.5 meter wide and not exceeding 1.5 meter in depth for foundation of poles, stays or for taking out/laying of cables and getting out in soft/loose soil complete all as specified and directed by Engr-in-Charge. | 54 | Cum | 90 ₹4,860 | 90 ₹4,860 | 80 ₹4,320 Lowest | 110 ₹5,940 | 100 ₹5,400 | 85 ₹4,590 |
| 2.00 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25cm in soft/loose soilcomplete all as specified and directed by Engr-in-Charge. | 28.95 | Cum | 50 ₹1,447.5 | 30 ₹868.5 Lowest | 40 ₹1,158 | 90 ₹2,605.5 | 45 ₹1,302.75 | 45 ₹1,302.75 |
| 3.00 | Removing excavated materials (soil) n. exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed by Engr-in-Charge. | 25.05 | Cum | 30 ₹751.5 Lowest | 30 ₹751.5 Lowest | 50 ₹1,252.5 | 110 ₹2,755.5 | 85 ₹2,129.25 | 45 ₹1,127.25 |
| 4.00 | M & L for sand cushioning to underground cable with clean dry river sand complete all as specified and directed by Engr-in-Charge. Note:- Punned thickness only shall be measured & Paid. | 16.2 | Cum | 400 ₹6,480 | 400 ₹6,480 | 350 ₹5,670 Lowest | 980 ₹15,876 | 350 ₹5,670 Lowest | 550 ₹8,910 |
| 5.00 | Supply & Laying of sub class 'B'bricks locally available best quality laid flat (length of bricks laid across the length of cable) in tranches for protection of U/G cable complete all as specified and directed by Engr-in-Charge. | 1.73 | Per 1000 nos | 3,000 ₹5,190 Lowest | 5,000 ₹8,650 | 3,500 ₹6,055 | 3,400 ₹5,882 | 4,000 ₹6,920 | 4,250 ₹7,352.5 |
| 6.00Supplying, laying, commissioning & testing LT underground cable 1100 volts grade, XLPE insulated, PVC sheathed heavy duty, armoured with multi stranded aluminium conductor all as per IS 7098(Part-I) 1998, laid in trenches, ducts, pipes or on poles etc including cable gland, cable lugs, jointing, supporting clamp complete etc of the under mentioned type and sizes complete all as specified and directed by Engr-in-Charge. | |||||||||
| 6.01 | (a) 50 Sqmm 4 core. | 200 | Rm | 280 ₹56,000 Lowest | 300 ₹60,000 | 300 ₹60,000 | 290 ₹58,000 | 370 ₹74,000 | 442 ₹88,400 |
| 6.02 | (b) 70 Sqmm 3. 5 Core. | 180 | Rm | 350 ₹63,000 Lowest | 400 ₹72,000 | 375 ₹67,500 | 390 ₹70,200 | 450 ₹81,000 | 512 ₹92,160 |
| 6.03 | (c) 95 Sqmm 3. 5 Core. | 170 | Rm | 450 ₹76,500 | 480 ₹81,600 | 425 ₹72,250 Lowest | 428 ₹72,760 | 650 ₹1,10,500 | 625 ₹1,06,250 |
| 7.00 | Material and labour for control relay MXO 4OE (4 NO) (Auxilary Contactor) for automatic power factor correction panel including taking out of old one all as specified and as directed. | 5 | Each | 800 ₹4,000 Lowest | 1,000 ₹5,000 | 850 ₹4,250 | 980 ₹4,900 | 1,000 ₹5,000 | 1,250 ₹6,250 |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
21 Aug 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE(I) Ayodhya
Asst Garrison Engineer (I), Military Engineer Services, Ayodhya Cantt PIN-224001
REPAIR/ REPLACEMENT/ MAINTENANCE OF APFC CAPACITOR BANK, APFC RELAY, CAPACITOR CYLINDER, CONNECTED CABLE AND ALLIED WORK AT AGE (I) AYODHYA
2025_MES_722389_1
8400/106/E8
Open Tender
Civil Works
Item Rate
180 days
Ayodhya Cantt
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
AGE(I) Ayodhya Cantt
₹20,000
Yes
11 Dec 2025
24 Jul 2025
25 Aug 2025
24 Jul 2025
21 Aug 2025
7 Aug 2025
Amount
Excavation in trenches, not exceeding 1.5 meter wide and not exceeding 1.5 meter in depth for foundation of poles, stays or for taking out/laying of cables and getting out in soft/loose soil complete all as specified and directed by Engr-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25cm in soft/loose soilcomplete all as specified and directed by Engr-in-Charge.
Removing excavated materials (soil) n. exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed by Engr-in-Charge.
M & L for sand cushioning to underground cable with clean dry river sand complete all as specified and directed by Engr-in-Charge. Note:- Punned thickness only shall be measured & Paid.
Supply & Laying of sub class 'B'bricks locally available best quality laid flat (length of bricks laid across the length of cable) in tranches for protection of U/G cable complete all as specified and directed by Engr-in-Charge.
Supplying, laying, commissioning & testing LT underground cable 1100 volts grade, XLPE insulated, PVC sheathed heavy duty, armoured with multi stranded aluminium conductor all as per IS 7098(Part-I) 1998, laid in trenches, ducts, pipes or on poles etc including cable gland, cable lugs, jointing, supporting clamp complete etc of the under mentioned type and sizes complete all as specified and directed by Engr-in-Charge.
(a) 50 Sqmm 4 core.
(b) 70 Sqmm 3. 5 Core.
(c) 95 Sqmm 3. 5 Core.
Material and labour for control relay MXO 4OE (4 NO) (Auxilary Contactor) for automatic power factor correction panel including taking out of old one all as specified and as directed.
Material and labour for ultra heavy duty Capacitors Cylindrical Series of capacity 5 kVAR three phase suitable for 440 volt AC 50 Hz supply including taking out of old one all as specified and as directed.
Material and labour for ultra heavy duty Capacitors Cylindrical Series of capacity 10 kVAR three phase suitable for 440 volt AC 50 Hz supply including taking out of old one all as specified and as directed.
Material and labour for ultra heavy duty Capacitors Cylindrical Series of capacity 15 kVAR three phase suitable for 440 volt AC 50 Hz supply including taking out of old one all as specified and as directed.
Material and labour for ultra heavy duty Capacitors Cylindrical Series of capacity 20 kVAR three phase suitable for 440 volt AC 50 Hz supply including taking out of old one all as specified and as directed.
Material and labour for ultra heavy duty Capacitors Cylindrical Series of capacity 25 kVAR three phase suitable for 440 volt AC 50 Hz supply including taking out of old one all as specified and as directed.
Material and labour for LED phase Indicator lamp Red/Yellow/blue 16 mm panel mounting type including taking out of old one all as specified and as directed.
Material and labour for Push Button Red/ Green panel mounting type including taking out of old one all as specified and as directed.
S & F MCB 415 V, triple pole, 25 to 63 Amps, 'C' curve, 10 kA including taking out of old one all as specified and as directed.
Supply & fix in replacement of MCCB, 4 pole, 100 Amp, 415V 50Hz with thermal magnetic trip unit rating breaking capacity 25 KA, lcs=100% of Icu, confirming to IS : 13947 (Part I & II) including connection and testing complete all as specified and as directed by Engr-in-Charge.
Supply & fix in replacement of MCCB, 4 pole, 125 Amp, 415V 50Hz with thermal magnetic trip unit rating breaking capacity 25 KA, lcs=100% of Icu, confirming to IS : 13947 (Part I & II) including connection and testing complete all as specified and as directed by Engr-in-Charge.
Supply & fix in replacement of MCCB, 4 pole, 160 Amp, 415V 50Hz with thermal magnetic trip unit rating breaking capacity 25 KA lcs=100% of Icu, confirming to IS : 13947 (Part I & II) including connection and testing complete all as specified and as directed by Engr-in-Charge.
Supply & fix in replacement of MCCB, 4 pole, 200 Amp, 415V 50Hz with thermal magnetic trip unit rating breaking capacity 36 KA lcs=100% of Icu, confirming to IS : 13947 (Part I & II) including connection and testing complete all as specified and as directed by Engr-in-Charge.
Supply & fix in replacement of MCCB, 4 pole, 250 Amp, 415V 50Hz with thermal magnetic trip unit rating breaking capacity 36 KA lcs=100% of Icu, confirming to IS : 13947 (Part I & II) including connection and testing complete all as specified and as directed by Engr-in-Charge.
Supply & fix in replacement of MCCB, 4 pole, 500 Amp, 415V 50Hz with thermal magnetic trip unit rating breaking capacity 36 KA, lcs=100% of Icu, confirming to IS : 13947 (Part I & II) including connection and testing complete all as specified and as directed by Engr-in-Charge.
S & F Capacitor duty contactors 415 volt, three phase with one built-in auxiliary contact (NO) of kVAR rating 30 kVAR including taking out of old one all as specified and as directed.
S & F Capacitor duty contactors 415 volt, three phase with one built-in auxiliary contact (NO) of kVAR rating 12.5 kVAR including taking out of old one all as specified and as directed.
S & F Capacitor duty contactors 415 volt, three phase with one built-in auxiliary contact (NO) of kVAR rating 8.5 kVAR including taking out of old one all as specified and as directed.
S & F three phase digital Voltmeter with LED display, accuracy class 1.0, voltage measurement range between phase to phase 50-550 volt AC flush mounting type of size 96 x 96 mm including taking out of old one all as specified and as directed.
S & F three phase digital Ammeter with LED display, accuracy class 1.0, AC flush mounting type of size 96 x 96 mm including taking out of old one all as specified and as directed.
S & F Current Transformer tape wound ring of capacity 200/5 Amp, burden 15 VA, precision class 1% including taking out of old one all as specified and as directed.
S & F Current Transformer tape wound ring of capacity 400/5 Amp, burden 15 VA, precision class 1% including taking out of old one all as specified and as directed.
S & F Current Transformer tape wound ring of capacity 500/5 Amp, burden 15 VA, precision class 1% including taking out of old one all as specified and as directed.
S & F APFC replay of step (5 +1*) of size 96 x 96 (3 Step APFC controller + 3 step plug-in-module) all as specified and as directed.
S & F APFC replay of step (7 +1*) of size 96 x 96 (5 Step APFC controller + 3 step plug-in-module) all as specified and as directed.
S & F APFC replay of step (15 +1*) of size 144 x144 (8 Step APFC controller + 3 step plug-in-module + 3 step plug-in-module) all as specified and as directed.
M & L for Painting 40 to 200 KVAR APFC Panel, remove by scraping the existing painting, cleaning, filling the cavities and applying single coat of spray painting with synthetic enamel paint (colour approved by AGE (I) including writing the size of capacitor. all as specified & directed.
Material Labour tools and transport for shiftifng of existing APFC panel from one location and refixing testing and commissioning to another location complete all as specified and directed
Supply, install, testing and commissioning on floor mounting Automatic Power Factor Correction (APFC) Panel out door type for 3 Phase, 415 V & 50 Hz system of capacity 80 KVAR without incoming MCCBs weather/vermin proof, made out of 3.15 mm thick CRCA sheet factory made with hinged door, colour code insulated 300 Amp rated copper bus bar 4 strip, painted with powder coated paint over a coat of red oxide zinc chrome primer complete with the following accessories all pre wired using PVC insulated copper conductor cable ( FR-LSH) of suitable size and mounting the panel on gorund/wall including taking out of old unserviceable panel.: -
M/L for Cement concrete for filling in foundations or making good of Road, PCC Floor, supports etc. Type B1, 1:2:4, using 20 mm graded stone aggregate including necessary form work and fair finishing of exposed surface of concrete / facia finish with cement mortar complete all as directed.
Earthing complete with galvanised steel earth plate electrode 600 X 600 X 6mm thick buried directly in ground vertically to a depth not less than 2.25 meters deep below ground level with top edge of the earth plate not less than 1.5 meters deep below normal ground level, connected with and including galvanised iron 4.00 mm dia connected to main test point as directed as earthing lead by means of nuts, bolts and washers of galvanised iron protected by 40mm dia (medium grade) GI tubing, funnel, wire mesh, 20mm bore GI tubing (light grade) watering pipe, including concrete pit in PCC (1:3:6) type C-1, precast RCC (1:2:4) type B-1 cover slab of size 350 x 350 x 50mm reinforced with 8mm dia TMT bars @ 15cm c/c in both ways and 10mm dia MS handle (01 No) of suitable size for lifting of cover slab, charcoal and salt in alternate layers including necessary excavation and earth work in soft/loose soil all as shown in Electric plate No 3 of SSR Part-I and testing on completion complete all as specified and directed by Engr-in-Charge.
His And Her Enterprises (BID ID -3393621)
Khan Brothers (BID ID -3392678)
FUTURE Inc. (BID ID -3387497)
M/s R.S. Enterprises (BID ID -3401332)
Ajanta Motor Store (BID ID -3401396)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .