Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.0 LAccepted-AOC H NO 18 BY LANE NO 09 SATGAON PRAGATI NAGAR GUWAHATI ASSAM 781171 | KAMRUP METRO | ASSAM | 781171 | L1 | Accepted-AOC lowest bidder | |
| 2 | L2₹30.8 L+₹2.2 L (7.65%)Rejected-Finance PRAGARI NAGAR BYE LANE 3 HOUSE NO 05 SATGAON UDAYAN VIHAR GUWAHATI 781171 | KAMRUP METRO | ASSAM | 781171 | L2 | Rejected-Finance Not Validated (Other than lowest bidder) |
Tender Value
Refer Docs
EMD Value
₹60,000
Closing Date
21 Jan 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE GUWAHATI
GE GUWAHATI, PO SATGAON, DISTT KAMRUP - 781027
REPAIR/MAINT TO EXTERNAL WATER SUPPLY SYSTEM INCLUDING CERTAIN ALLIED WORKS AT BASISTHA UNDER GE GUWAHATI
2022_MES_567862_1
GE/GUW/71/8255 OF 2022-23
Open Tender
Civil Works
Item Rate
160 days
GUWAHATI
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE GUWAHATI
₹60,000
Yes
11 Feb 2023
7 Dec 2022
23 Jan 2023
7 Dec 2022
21 Jan 2023
2 Jan 2023
7 Dec 2022 - 14 Dec 2022
Amount
Excavation in trenches not exceeding 1.5m in depth for for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc laying of GI pipes etc and getting out in soft/loose soil complete all as specified and as directed.
Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25cm complete all as specified and as directed.
Removing excavated material n.exc 50m and depositing were directed at a level not exceeding 1.5m above the starting level complete all as specified and as directed.
Supply, Laying, jointing & testing of Ductile iron (DI), pressure pipes with spigot and socket ends, centrifugally cast, class K-7, with cement mortar lining in inner side as per IS:8329 and other relevant standards and metalic zinc coating followed by a finishing layer of epoxy paint in outer side, suitable for push on joint (rubber gasket joint) in any length with inside cement mortar lining, 250 mm bore laid in trenches, including taking out the old CI pipe complete all as specified and directed.
Supply, Laying, jointing & testing of Ductile iron (DI), pressure pipes with spigot and socket ends, centrifugally cast, class K-7, with cement mortar lining in inner side as per IS:8329 and other relevant standards and metalic zinc coating followed by a finishing layer of epoxy paint in outer side, suitable for push on joint (rubber gasket joint) in any length with inside cement mortar lining, 200 mm bore laid in trenches, including taking out the old CI pipe complete all as specified and directed.
Supply, Laying, jointing & testing of Ductile iron (DI), pressure pipes with spigot and socket ends, centrifugally cast, class K-7, with cement mortar lining in inner side as per IS:8329 and other relevant standards and metalic zinc coating followed by a finishing layer of epoxy paint in outer side, suitable for push on joint (rubber gasket joint) in any length with inside cement mortar lining, 150 mm bore laid in trenches, including taking out the old CI pipe complete all as specified and directed.
Material and labour for ductile iron fittings for spigot & socket ductile iron pipes such as bends (any type, radius and angle), taper any type (straight, bend, increasing decreasing or double socket etc) Tee pieces single branch, "Y" junction, double branch, cross (all sockets or socket and spigot), collars, cap and plug suitable for push on joints size up to 250 mm bore, including taking out the old CI fittings complete all as specified and directed.
Taking down 20mm bore steel tubing and connections, complete all as directed
Taking down 25/32mm bore steel tubing and connections, complete all as directed
Taking down 40/50mm bore steel tubing and connections, complete all as directed
Taking down 80mm bore steel tubing and connections, complete all as specified and directed
Taking down 100mm bore steel tubing and connections, complete all as specified and directed
M&L 110mm outer diameter, 3- layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches complete all as specified and as directed.
M&L 90mm outer diameter, 3- layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches complete all as specified and as directed.
M&L 63mm outer diameter, 3- layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches complete all as specified and as directed.
M&L 32mm outer diameter, 3- layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches complete all as specified and as directed.
M&L 25mm outer diameter, 3- layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches complete all as specified and as directed.
Supply, installation, Testing and commissioning of SS Probe unit of suitable tank for overhead tanks of maximum depth of 5 meters of water level(Depth of water tank shall be upto 7 mtrs), the probe shall have continuous magnetic read sensor with resolution of 1omm with 0-5000 ohms resistance to act as potentiometer, the sensor to be actuated by a single actuating float to give analog output on level at any stage including wiring complete all as per manufacturers instruction and as directed.
S&F of Digital Indicator unit with Jumbo 5 Digit Red LED 7 Segment display of 100mm each, the unit shall have High and Low alarm to be set according to the requirement based on level indicated , and should be possible to calibrate the indicator to display in percentage or litres, centimeter as required including complete wiring all as per complete manufacturers instruction and as directed.
M&L 63mm outer diameter, PP-R Gate valves (brass insert) complete all as specified and as directed.
M&L 32mm outer diameter, PP-R Gate valves (brass insert) complete all as specified and as directed.
M&L 25mm outer diameter, PP-R Gate valves (brass insert) complete all as specified and as directed.
S&F in repair CI sluice valve of size 250 mm bore with brass spindle and cast iron hand wheel head & brass spindlecomplying with IS:14846-2000, class PN 1.6 both ends flanged complete with rubber/fibre board insertion gasket joints, nuts, bolts & washers of required size & Nos complete all as specified and as directed.
S&F in repair CI sluice valve of size 200 mm bore with brass spindle and cast iron hand wheel head & brass spindle complying with IS:14846-2000, class PN 1.6 both ends flanged complete with rubber/fibre board insertion gasket joints, nuts, bolts & washers of required size & Nos complete all as specified and as directed.
S&F in repair CI sluice valve of size 150 mm bore with brass spindle and cast iron hand wheel head & brass spindle complying with IS:14846-2000, class PN 1.6 both ends flanged complete with rubber/fibre board insertion gasket joints, nuts, bolts & washers of required size & Nos complete all as specified and as directed.
S&F in repair CI sluice valve of size 100 mm bore with brass spindle and cast iron hand wheel head & brass spindle complying with IS:14846-2000, class PN 1.6 both ends flanged complete with rubber/fibre board insertion gasket joints, nuts, bolts & washers of required size & Nos complete all as specified and as directed.
S&F in repair CI sluice valve of size 80 mm bore with brass spindle and cast iron hand wheel head & brass spindle complying with IS:14846-2000, class PN 1.6 both ends flanged complete with rubber/fibre board insertion gasket joints, nuts, bolts & washers of required size & Nos complete all as specified and as directed.
S&F in repair 15mm dia Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 15mm - 142 gms) complete all as specified and as directed.
S&F in repair 20mm dia Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 20mm - 210 gms) complete all as specified and as directed.
S&F in repair 25mm dia Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 25mm - 455 gms) complete all as specified and as directed.
M&L Run lead joint for 80mm dia CI SPIGOT AND SOCKET PIPES AND FITTINGS complete all as specified and as directed.
M&L Run lead joint for 100mm dia CI SPIGOT AND SOCKET PIPES AND FITTINGS complete all as specified and as directed.
M&L Run lead joint for 150mm dia CI SPIGOT AND SOCKET PIPES AND FITTINGS complete all as specified and as directed.
M&L Run lead joint for 200mm dia CI SPIGOT AND SOCKET PIPES AND FITTINGS complete all as specified and as directed.
Burning out lead joint in position for 80mm bore, CI SPIGOT AND SOCKET PIPES AND FITTINGS including removing old lead complete all as directed.
Burning out lead joint in position for 100mm bore, CI SPIGOT AND SOCKET PIPES AND FITTINGS including removing old lead complete all as directed.
Burning out lead joint in position for 150mm bore, CI SPIGOT AND SOCKET PIPES AND FITTINGS including removing old lead complete all as directed.
Burning out lead joint in position for 200mm bore, CI SPIGOT AND SOCKET PIPES AND FITTINGS including removing old lead complete all as directed.
Labour only Run lead joint for 80mm dia CI SPIGOT AND SOCKET PIPES AND FITTINGS complete all as directed. Note: Old lead reteravied from Stl item No. 35 to be reused
Labour only Run lead joint for 100mm dia CI SPIGOT AND SOCKET PIPES AND FITTINGS complete all as directed. Note: Old lead reteravied from Stl item No. 36 to be reused
Labour only Run lead joint for 150mm dia CI SPIGOT AND SOCKET PIPES AND FITTINGS complete all as directed. Note: Old lead reteravied from Stl item No. 37 to be reused
Labour only Run lead joint for 200mm dia CI SPIGOT AND SOCKET PIPES AND FITTINGS complete all as directed. Note: Old lead reteravied from Stl item No. 38 to be reused
M&L in repair, rubber or fibre board gasket joint suitable for ductile iron pipe of 100mm dia including nut, bolts and washers complete all as specified and as directed.
M&L in repair, rubber or fibre board gasket joint suitable for ductile iron pipe of 150mm dia including nut, bolts and washers complete all as specified and as directed.
S&F in repair, mechanical joint made out of MS Sheet fabricated as per existing site requirement suitable for 80mm bore CI/DI/GI pipe including nut, bolts and washers complete all as specified and as directed. Note:- Necsssary Earth work, i.e. excavation, Return filling in, Removing if required etc is deemed to inclusive in the Unit Quoted rate
S&F in repair, mechanical joint made out of MS Sheet fabricated as per existing site requirement suitable for 100mm bore CI/DI/GI pipe including nut, bolts and washers complete all as specified and as directed. Note:- Necsssary Earth work, i.e. excavation, Return filling in, Removing if required etc is deemed to inclusive in the Unit Quoted rate
S&F in repair, mechanical joint made out of MS Sheet fabricated as per existing site requirement suitable for 150mm bore CI/DI/GI pipe including nut, bolts and washers complete all as specified and as directed. Note:- Necsssary Earth work, i.e. excavation, Return filling in, Removing if required etc is deemed to inclusive in the Unit Quoted rate
S&F in repair, mechanical joint made out of MS Sheet fabricated as per existing site requirement suitable for 200mm bore CI/DI/GI pipe including nut, bolts and washers complete all as specified and as directed. Note:- Necsssary Earth work, i.e. excavation, Return filling in, Removing if required etc is deemed to inclusive in the Unit Quoted rate
S&F in repair, mechanical joint made out of MS Sheet fabricated as per existing site requirement suitable for 300mm bore CI/DI/GI pipe including nut, bolts and washers complete all as specified and as directed. Note:- Necsssary Earth work, i.e. excavation, Return filling in, Removing if required etc is deemed to inclusive in the Unit Quoted rate
Chemical and bacteriological testing of water sample collected from over head tank, UG Sump and consumer end of Narangi and Basistha area (one water sample to be collected from each place) once in month to ensure potability of water from any Government approved laboratory complete all as directed. Note:- Cost collecting the sample, transporting the sample to the lab and submitting the Test report is demmed to be inclusive of the UNIT RATE QUOTED.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) , 650/1100 Volts grade conforming to IS 7098(Part I) 1988 with upto date ammendtments with stranded COPPER conductor of size 16 sqmm single core, drawn through pipe or laid in ducts through pip complete all as specified and as directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) , 650/1100 Volts grade conforming to IS 7098(Part I) 1988 with upto date ammendtments with stranded COPPER conductor of size 25 sqmm single core, drawn through pipe or laid in ducts through pip complete all as specified and as directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) , 650/1100 Volts grade conforming to IS 7098(Part I) 1988 with upto date ammendtments with stranded COPPER conductor of size 35 sqmm single core, drawn through pipe or laid in ducts through pip complete all as specified and as directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) , 650/1100 Volts grade conforming to IS 7098(Part I) 1988 with upto date ammendtments with stranded COPPER conductor of size 50 sqmm single core, drawn through pipe or laid in ducts through pip complete all as specified and as directed.
Cutting of existing cast iron pipes of 80mm bore in position for insertion of new tees, branches, etc. complete all as specified and as directed. Note: (i) CI specials as required will be measured and paid separately under appropiate item (ii) Necsssary Earth work, i.e. excavation, Return filling in, Removing if required etc is deemed to inclusive in the Unit Quoted rate
Cutting of existing cast iron pipes of 100mm bore in position for insertion of new tees, branches, etc. complete all as specified and as directed. Note: (i) CI specials as required will be measured and paid separately under appropiate item (ii) Necsssary Earth work, i.e. excavation, Return filling in, Removing if required etc is deemed to inclusive in the Unit Quoted rate
Cutting of existing cast iron pipes of 150mm bore in position for insertion of new tees, branches, etc. complete all as specified and as directed. Note: (i) CI specials as required will be measured and paid separately under appropiate item (ii) Necsssary Earth work, i.e. excavation, Return filling in, Removing if required etc is deemed to inclusive in the Unit Quoted rate
Cutting of existing GI pipes of 40mm to 80mm bore in position for insertion of new tees, branches, etc. complete all as specified and as directed. Note: (i) GI specials as required is deemed to inclusive in the Unit Quoted rate (ii) Necsssary Earth work, i.e. excavation, Return filling in, Removing if required etc is deemed to inclusive in the Unit Quoted rate
Cutting of existing GI pipes of 20mm to 25mm bore in position for insertion of new tees, branches, etc. complete all as specified and as directed. Note: (i) GI specials as required is deemed to inclusive in the Unit Quoted rate (ii) Necsssary Earth work, i.e. excavation, Return filling in, Removing if required etc is deemed to inclusive in the Unit Quoted rate
Cleaning of MES water supply installation/campus by surface dressing, trimming of natural ground to removing all vegetations/shurbs/bushes etc , cleaning of drains and removing of rubishes/debries of the permises complete all directed. Note:- Cleaning of MES water supply installation/campus as described may be carried out at an interval of 30 days as directed by Engg-In-Charge
Disconnecting cable of size 95Sqmm 3.5 Core from the existing panel and Cleaning/dressing of cables ends including cutting/removing rusted/burnt ends of cables and providing new aluminum lugs, gland with proper clamping, with necessary nuts bolts as required and reconnecting the same in the existing position complete all directed.
Disconnecting cable of size 70Sqmm 3.5 Core from the existing panel and Cleaning/dressing of cables ends including cutting/removing rusted/burnt ends of cables and providing new aluminum lugs, gland with proper clamping, with necessary nuts bolts as required and reconnecting the same in the existing position complete all directed.
Disconnecting cable of size 50Sqmm 3.5 Core from the existing panel and Cleaning/dressing of cables ends including cutting/removing rusted/burnt ends of cables and providing new aluminum lugs, gland with proper clamping, with necessary nuts bolts as required and reconnecting the same in the existing position complete all directed.
Disconnecting cable of size 16Sqmm 4 Core from the existing panel and Cleaning/dressing of cables ends including cutting/removing rusted/burnt ends of cables and providing new aluminum lugs, gland with proper clamping, with necessary nuts bolts as required and reconnecting the same in the existing position complete all directed.
M&L painting of CI/DI/GI pipe line of any size in various MES pump houses located in Basistha and Narangi area with one coat of syntheic enamel paint and writing of inlet/outlet direction, area of feeding etc, as directed including necessary preperation of surfaces complete all directed.
S&F in repairs,water pressure guage of capacity 7.5Kg/Sqmm, guage dial type complete all as directed
S&F in repair RYB indicator lamp LED type(Set of three lamp) for incomming and outgoining supply as per existing sizes complete all as directed.
S&F in repairs, Ammeter three phase digital type 50 Hz, AC as per existing size/Range complete.all as directed.
S&F in repair Voltmeter three phase digital type 0-500 Volts 50 Hz, AC, as per existing size complete.all as directed.
S&F in repair Valve pit chamber cover made out of 3mm thick MS sheet with handle, locking arrangement as per existing and painting with two coats of syntheic enamel paint over a coat of red oxide primer over including necessary preperation of surfaces complete all as directed.
M&L Construction Brick Masonry Valve Pit of size 1200x12000x1200 mm (Internal Dimension) one Brick thick Wall in Cement Mortar 1:4 on 100mm thick PCC 1:4:8 (40mm graded aggregate) in Foundation, Rendering 15mm thick internally and externally upto 150mm below GL, providing 3.0mm thick MS Sheet Valve Pit Cover, welded with 40x5mm Flat Iron Frame alround including provision of Hinges, Handle with Locking Arrangement and 40x40 x6mm Angle Iron Frame fixed on top of Valve Pit by means of holdfast 150mm long, embedd -ed in PCC 1:2:4 (20mm graded aggregate) Block of size 230x200x100 mm, applying two coats of Anti-corrosive Paint to all exposed Steel Surfaces over a coat of red oxide zinc chrome Primer after preparation of Surfaces and necessary Earth Work in Soft/ Loose Soil including demolition of unserviceable Valve Pit, complete all as specified and as directed.
M&L preparation old treated surfaces of CI/DI/GI pipe and applying one coats of synthetic enamel paint, including embosing direction of inlet/outlet direction, writing area of feeding etc in pipe surfaces complete all as specified and directed.
Repair to CI water meter of size 300mm enclosed type both end flanged complete all as directed. Note:- Repair of water meter shall be carried out at authorized service/testing center and certificate of repair and caliberation shall also be submitted and cost is deemed to be inclusive in the unit quoted rate
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .